Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC accept | |
| 2 | L2₹43.8 L+₹2.6 L (6.37%)Rejected-AOC NOT AVAILABLE | NA | NA | 121004 | L2 | Rejected-AOC accept | |
| 3 | L3₹49.2 L+₹8.0 L (19.5%)Rejected-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L3 | Rejected-AOC accept | |
| 4 | L4₹65.2 L+₹24.0 L (58.3%)Rejected-AOC | L4 | Rejected-AOC accept |
Tender Value
₹21.0 L
EMD Value
₹38,930
Closing Date
25 Feb 2020, 5:00 pmClosed
Executive Engineer IPH Division Thural
O/O The Executive Engineer IPH Division Thural
C,O LIS Roura Dhatti , adjoining villages in Tehsil Palampur Distt.Kangra HP
2020_HPIPH_34784_1
THL-KNG05-729 ( 14387-14450 dated 10.02.2020)
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
180 days
C, O LIS Roura Dhatti, adjoining villages in Tehsi
Please refer Tender documents.
8 documents required · 8 mandatory
₹250
₹38,930
Yes
6 Apr 2021
10 Feb 2020
26 Feb 2020
10 Feb 2020
25 Feb 2020
10 Feb 2020
Amount
Excavation in foundation and trenches etc. (in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiselling/wedging out of rock/where blasting prohibited)saturated soil stacking the excavated earth within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposting of all surplus excavated earth as directed within all leads and lifts including uprooting of trees dressing of beds, and sides and preparation of sub-grade, restoration of unmetalled/metalled/paved surfaces to its original condition including soring, strutting, timbering and dewatering where ever houses, fixing caution boards, crossing over trenches and to the entire satisfaction of the Engineer-in-charge.
Providing ,laying ,Jointing & testing of bevel edged MSERW pipe with circumfrential butt welded joints by elecrtrical arc welding with in (welding thickness shall be equal to pipe wall thickness )and welding M.Sflanges at every 100mtr pipes & testing of MSERW pipe of following dia mtr conforming to BIS 3183-2007 ,steel grade L-415 & L-210 (latest with upto date amendments )having wall thickness as specifid below and capable of with standing required test pressure in a rendom length of 5.5 to 6.5 mtr , including manufactruing reducers /tapers ,all short pices etc as per site requirement made from parent tubes .The laying of pipe shall also include flanges joints duly welded in three layers (two inner and one outer )where ever reuired as per the direction of Engineer-in-charge (earh work and trenches and the cost of proving flanges i/c nuts and bolts and gasket will be measured and paid for separatly)and all operation ssuch as cuting ,welding,jointing ,fabrication of Tee i/e lowering and laying in excavated trenches o insure requirded level i/c flshing,cleaning & hydrolic testing complete in all respect to the satisfaction of the Engineer in charge .The pipe shall be factory galvanized (zinc coating both inside and outside )as per relevent IS standerds and the damaged portion of the pipes and special (if damaged during L/J oparation of pipe)made from the parant tube ,shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coats as per AWWA specification C-203-1978 . the welding elctrodes shall be as per IS 814 of Advani oerLikon / L& T or IS marked make. The rate also include entire carraige of material ,flushing.cleaning & Hydrolic testing ,DP test butt welded joints complete in all respect and to the best satifation and direction of Engineer-in-charge with in all leads & lifts.Note Negitive Tolerance of wall thickness should not be more than 3%..
1st STAGE MSERW pipe 200 mm dia with wall thickness of 4.80 mm Flange Table-5
2nd stage MSERW pipe 200 mm dia with wall thickness of 4.80 mm Flange Table-17.
Booster stage P/well:- Supply of submersible pumping set of KSB/Kalama/SU/Johnston/Cromption/BS make conforming to BIS:8034-1976 (latest suitable for lifting clear water (latest with upto date ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrel cage/slippering electric induction motor of same make as(manufactruer standerd)conforming to BIS: 9283-1979 (latest with upto date ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical, loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard, errection clamps, cable clips & depth gauge etc. The pump shall be suitable for operation on data on data given below :- 2 Nos. sets 2 x 7.50 =15.00 HP
i)Total Head:- 15.85 Mtrs ,ii) Discharge :- = 17.08 LPS each pump. iii)No of Pump required 2.00 Nos.iv) Location of site:- The site is located at a distance of 20 Km. from Maranda Railway station on Palampur Sujanpur Road. Site is located at 150 Kms from Pathankot & 400 mtrs by head load.v)The altitude of installation The Altitude of place is 450 mtr above MSL.vI) Type of current AC three phase supply.vii)Rate Voltage415 +10 %.viii)Type of water and it source Clear water from P/Well.iX)Charactristics of water.a)Ambiaent Temprature dig. C 20 Dig.C.b)Turberity NTU 10 NTU.c) Hardness 260 Mg/Ltrs(as CaCo3).d) PH 7.50.e)Total solid Mg/Ltrs.f)Others x)Depth of Percolation well 10.00 Mtrs.xi)LWL in Tube well = mtr.xii) Dia of Bore well:- 6 mtrs. xiii)Maz draw down - mtr .xiv) Static water level - 683mtr. xv)Center line level of pump 683.00 mtr. xvi)Dishcharge level of highest point 686 mtr.xvii)Staic head in Mtr 72 mtr.xviii)Length of R/Main- ) 150 mtr.xix)Dia of Rising Main -200 mm dia.xx)No of working hours per day 20.00 Hours.xxi)Limit of pump operation (-)15 %(+)10% of total .xxii)R.P.M pointing set 2900 RPM (or to be specified by the Tenderer ).xxiii)Test Run 3 Hours continueously per seven days.
Supply installation commissioning and testing pf PLC based waster controller Monitoring & operating panel for 1 nos Ultra Sonic non contract sensors for 1 nos UGSR 6 Nos poump set with 6 nos .Automatract controlling of notorize valve to operate the water Supply system with Visual annunctian panel/screen with modlus eorded Transmter/receiver until modern for GSM/GPRS/Internet/Satelite baed Network for furture IGT externsions Monitorring of complete water supply system with wired command from controller for switching on & off of pump set as per the water level in RGSR along with wired control feed back from ultra Sonic sensor from UGSR and shuld be capable to over ride the system manually in case of Auto failure.The sysrem should be backed up with inverter supplly for delivery line motorize valve in case of power supply failure.The system will also have an HMI/Digital disply for water level monotoring in ratio from 0% to 100% in linear motion for OHT long with Visual information for the motorize valve and pump set status plosition it should becapable to send SMS for any fault ingrmation as per pre definede text or code for particular trupping which can be future interlinked with OT System.
The panel shall be wall/Floor mounting and shall be of suitable size made of 2mm/1.6mm CRCA sheet properly powerder coated.The make of PLC & automation panel L7T/ABB/Schendler (a) Coloured touch screen display of 7th size of high intencity to design the graphics for plant lay out of overhead/sumptanks water level indication with flusing mimic delivery valve open /close condition and pump set On/Off runing Graphical Mimi,(b) GPRS /RF/option for remote monotering of complete water supply. (c)Sinfgle/Reverse phasing over/Under voltage(OV/UV),Unbalanced voltage(UBV)short circut(SC).Over load(OL)&Pump set dry running protection and alarming foult through SMS to 5 mdobile Nors(d) Provision of automatic chlomine pump operation.9e)Opening nd closing of Delivery line motorize valves.(f) Phase indicator R 1 set 9g) Pump On/Off indicator .3 set (h) Delivery Line Open /Close indication 1 set.(i) Over head tank full/Empty.
Supply instalation testing and commissioning of fully automatic LT panel for submersible pump made out of 16 Gouge sheet poweder coated dust and veremin profwalll mounted and front opering do on type switch board with copper insulated wiring suiatble to operate 2 No,pump automatically as per site requirment along with acctutor sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirment through PCL panel(CPRI) approved ,with 50 KA Short circut and IP-55 protection dult insulated with heat shrinkable sleeve as per colour,supported on eproxy insulater 01 set common earth bus 25mmx4mm at bottom inside panel board with two earth terminal out side pannel board ,cable alley cable gland with independent plate at bottom and complete pannel board painted with powder coating in grey colour all as specified & directed make of pannel board :devlop aspl/tricolite.
ICTP switch bill HRC fuses L & T /Standerd/Haveells make & having capacity 30 % extra of the operational rating of motor as per BIS-4064-1978 with up to date ammendments immidiatly after the power meter of HPSEB.
MCB/MCCB sutable capacity of L & T/Standered make on the coming feeder for pumping set conforming to BIS-2516-1985 (Latest edition )with natural linked under voltage relese
Y-D starter 15 HP for submerible pump Make-L&T/Abb/Schneider
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS-3452 (part I & II) latest with upto date ammendments.
Star delta timer.
Single phase preventer of reputed make Minillic/L & T /Standerd & suitable capacity.
Automatic phase Sequance Corrector with prevention against,phase reversal protection ,under/over load protection make Abb/L&T/Siemens.
Control MCB 6A-SP.
On/Off indicator and push botton.
Control and power wiring.
Power Capactor.
Control terminal ,Buss Bar i.e Bolt insulator etc.
LED 5 Watt
Coling fan 230 VAC
Hour Meter
Supply ,Installation commissioning and testing of Presuure transmiter on thedelivery side of pump having Analog output of 0 to 20 mm make denfoss/sasa
Supply ,Installation commissioning and testing of Ultra Sonic not contact for level monitoring Make Schnelder/Siemns/ABB.
Supply of Kirloskar/Kilburn/Fources/Gled/BHEL/Leader make cast steel (class ASA-150 ) double flanged actuated sluice valve having size one dia. Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 21 kg/cm2 as per IS :780-1984 (Part I) .Note:- The C.I sluice valve shall conform to BIS 780-1984 for 50 to300 mm dia & BIS 2906-1984 for 350 to 1200 mm dia(latest adition)however If seat pressure exceeds the limits prescibed in above mentioned BIS.Than it shall be of Cast steel conforming to class ASA-150 for seat pressure upto10 kg/cm2 or class ASA-300 for seatpressure 52 kg/cm2 as BS 1414(API600)
Supply of Kirloskar/Kilburn/Fources/Gled/BHEL/Leader make cast iron double flanged (swing check type) reflux valve class PN-1.0 having bye pass arrangement ( to be provided on delivery side ) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 10 Kg/Cm 2 as per BIS 5312-1984 (Part-I )
Supply of Kirloskar/Kilburn/Fources/Gled/BHEL/Leaderr make cast iron class PN. 1.0 double flanged (swing check type) reflux valve having bye pass arrangement and size to Rising main i.e 200 mm shall be suitable for withstanding nominal seat pressure of 10 Kg/Cm 2 as per BIS 5312-1984 (Part-I )
Providing and laying PVC insulated jointless flat water prof copper cable of Siemens/Finolex/Grandly/Gloster make conforming to BIS :1554(part-i)-1988 or latest with upto date ammendments of suitable size for the pump sets offered(one cable carryig all three phases) including all others electrical equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts cable glands etc.Laid in pipes or trenches under floor.The type size & make will be subject to approval of HPSEB authorities in case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3 1/2 core copper cable 4.0mm ^2(From HPSEB meter to switch and starter .
On Motor side 3 core flat jointless copper cable of size 2.50mm ^2 (From switch & starter to motor)pump installed in the well .
Supply & errection of floor power shunt capacitor conforming to BIS:2834-1986 latest with upto date ammendments of GEC/Siemen/Havells L&T make to rise the prevelliging power factor at site to 0.95 for direct connection to induction motor indivisually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including stadered /L&T/Kilburn/Indo Asian Make ICTP swithes conforming to BIS 4064-1978 or latest with HRC fuses.2x3=6
Supply of standered make 200 mm dia cicular /Square dial pressure guage of suitable rnge Fiebeg/Bourden/Precisio make with all accessories such aas stop cock-copper tubeling etc.Conforming to BIS:3624-1987 latest with upto date ammendments.
P/Laying coloum assembly of G.I /MSERW pipe considering site requirments and having appropriate size in accordence with the delivery size of pumping set. The pipe shall conform to relevent BIS codes & capable of with standing the field test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends,papers/resucers,flanges, rubber gasket 3 mm thick,nuts and bolts and any other fitting required at site and work shall be provided under the entire satisfaction of Engineer in chahrge.Coulmn assembly=200 mm dia G.I Flanged pipe(medium grade).
NOTE:- Actual laying to be done as per fnal drawings to be approved by the Engineer in charrge.Errection of all equipments i/c cost of tees,bends tapers & any other fitting required as per site conditions & as per slection of Engneer in charge.
2nd stage Centrifugal pumping machinery .Providing horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar/Lubi/crompton.Hindostan as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF/Joyti and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% 25% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- 2 sets complete i/c allied accessories i.e. 2 x 40.00 =80.00 HP
Discahrge (Q) : -17.08 LPS each pump,or 106.56 Cum/Hour.Total dynamic head : 89.71Mtr.(a) LWL in sump well (h) :680.5Mtr.(b) Shaft level :681Mtr.(c ) Level at discahrge point :753Mtr.(d) Suction lift :.+veMtr.(e) Residual head :3Mtr.(f) Static head :72Mtr.(i) Rising Main :(a) Length600 mtr.(b) Dia. :200mm.(iv) Pumping Hours :20Hours.(v) Altitude of installation above MSL :(vi) Characteristics of water :(a) Temperature :20.00, 0 C.(b) Ambient temperature:42,oC.(c ) Turbidity < than:- 50.00 NTU.(d) Alkalinity Mg/Ca Co3.(e) RPM:2900
Supply instalation testing and commissioning of fully automatic LT panel for centerifugal pump made out of 16 Gouge sheet poweder coated dust and veremin profwalll mounted and front opering do on type switch board with copper insulated wiring suiatble to operate 2 No,pump automatically as per site requirment along with acctutor sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirment through PCL panel(CPRI) approved ,with 50 KA Short circut and IP-55 protection dult insulated with heat shrinkable sleeve as per colour,supported on eproxy insulater 01 set common earth bus 25mmx4mm at bottom inside panel board with two earth terminal out side pannel board ,cable alley cable gland with independent plate at bottom and complete pannel board painted with powder coating in grey colour all as specified & directed make of pannel board :devlop aspl/tricolite.
ICTP switch bill HRC fuses L & T /Standerd/Haveells make & having capacity 30 % extra of the operational rating of motor as per BIS-4064-1978 with up to date ammendments immidiatly after the power meter of HPSEB.
MCB/MCCB sutable capacity of L & T/Standered make on the coming feeder for pumping set conforming to BIS-2516-1985 (Latest edition )with natural linked under voltage relese
Y-D starter 15 HP for submerible pump Make-L&T/Abb/Schneider
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS-3452 (part I & II) latest with upto date ammendments.
Star delta timer.
Single phase preventer of reput ed make Minillic/L & T /Standerd & suitable capacity.
Automatic phase Sequance Corrector with prevention against,phase reversal protection ,under/over load protection make Abb/L&T/Siemens.
Control MCB 6A-SP.
On/Off indicator and push botton.
Control and power wiring.
Power Capactor.
Control terminal ,Buss Bar i.e Bolt insulator etc.
LED 5 Watt
Coling fan 230 VAC
Hour Meter
Supply of Kirloskar/Kilburn/Fources/Gled/BHEL/Leader make cast steel class ASA-150 double flanged actuated sluice valve having size one dia. Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 21 kg/cm2 as per IS :780-1984 (Part I) .Note:- The C.I sluice valve shall conform to BIS 780-1984 for 50 to300 mm dia & BIS 2906-1984 for 350 to 1200 mm dia(latest adition)however If seat pressure exceeds the limits prescibed in above mentioned BIS.Than it shall be of Cast steel conforming to class ASA-150 for seat pressure upto10 kg/cm2 or class ASA-300 for seatpressure 52 kg/cm2 as BS 1414(API600)
Supply of Kirloskar/Kilburn/Fources/Gled/BHEL/Leader make Cast iron double flanged (swing check type) reflux valve class PN-1.0 having bye pass arrangement ( to be provided on delivery side ) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 10 Kg/Cm 2 as per BIS 5312-1984 (Part-I )
Supply of Kirloskar/Kilburn/IVC/Gled/BHEL/Leader make cast iron class PN. 1.0 double flanged (swing check type) reflux valve class having bye pass arrangement and size to Rising main i.e 200 mm shall be suitable for withstanding nominal seat pressure of 10 Kg/Cm 2 as per BIS 5312-1984 (Part-I )
Providing and laying copper PVC insulated jointless ,flat water proof copper cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National /Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
Supply side 3 1/2 core (from HPSEB meter to switch & starter): 16mm2 cable Min length = 5 mtrs.
Motor side 3 core (From switch & starter to motor): 10 mm2 cable Min. length = 20 mtrs.
Providing and fixing double loop earthing and G.I. plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-52 Kg/cm2
Providing 100mm dia. circular dial Vaccum gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-52 Kg/cm2
Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVAR rating according to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments .2 X 9=18
Providing and fixing double flanged MSERW/GI pipes of suitable size for sunction ,delivery and common header considering site requirement & NPSH required/available. the pipe pipes size for suction and delivery shall as per the requirement of offered pump (to be given by the tenderer) and common header shall have area to equal to two times the area of delivery pipe of pump or equal to dia of R/main including tapers,flanges,bends,rubber gasket,3 mm thick nut & bolt and special upto 5 mtrs away from the outer wall of pump house as per layout drawing approved by the Engineer-in-Charge .( The pipes shall be as per relevant IS Code and to withstand 1.5 times the operating pressure and arrangement shall comprise of :- Note:- Actual laying to be done as per final drawing to be approved by the Engineer-in- charge,
(i) Suction pipe 100 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 800 mm dia -do- = 4 mtr.
(iii) Common Header 200 mm dia -do- = 5 mtr.
Erection of all equipment from sr no including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .