Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC | ₹42.3 L Quoted ₹42.4 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹45.2 L+₹2.8 L (6.55%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹45.2 L+₹2.8 L (6.55%) | L2 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹85,700
Closing Date
13 May 2021, 6:00 pmClosed
GE (AF) CHILODA
AF STN VAYUSHAKTI NAGAR, CHILODA, GANDHINAGAR
PROVISION OF FALSE CEILING, ROOF CEILING WITH LED LIGHTS, PATH, LADDERS, DRAINAGE COVER, CHEMICAL EARTHING AND SPLIT AC AT VARIOUS LOCATIONS AT AF STN GANDHINAGAR AND VSN CHILODA
2021_MES_436193_1
8905/21-22
Open Tender
Civil Works
Item Wise
180 days
VAYUSHAKTINAGAR
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (AF) CHILODA
₹85,700
Yes
2 Jun 2021
13 Apr 2021
15 May 2021
13 Apr 2021
13 May 2021
1 May 2021
Amount
M&L for chemical earthing of copper plate electrode of size 900x600x5mm thick and using copper strip 32x5mm as per IS : 3043 complete al as specified sand directed by Engineer-in-Charge. Note:- (a) Earth to Neutral voltage not more than 2 Volts. (b) Earth resistance value shall be less than 01 Ω (Ohm) (c) Painting and lebeling on the earth pit cover shall be deemed to be inclusive in the qouted rate by the contractor. (d) Earthing strip protection pipe dia 40 mm of length 7.5 RM shall be inclusive in the qouted rate by the contractor. (e) 02 Nos. of earthing for DCN Node and 09 Nos of earthing.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of copper strip size 32x6mm complete all as specified and directed by Engineer-in-Charge.
M&L GI pipe Light grade 40mm dia for protection of copper earth strip buried in ground or fixed to wall/ roof/ ceiling inclusive of suitable size clamps/ shaddels complete all as specified and as directed.
S&F for false ceiling work with approved ceiling board of size 600x600x9mm thick Armstrong make armgyp tiles. Complete all as specified and directed by Engr-in-charge.
S&F grid frame work of powder coated aluminum sections for 600x600 mm false ceiling board . wall angle of size 25x25x0.35mm , Main and cross T- section (Bottom pre coated) of size 24x38x0.70mm, holding clips and GI 6mm dia hangers (upto 1200 length) for grid size600x600x9mm thick Armstrong make armgyp tiles false ceiling adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for concealed point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through metallic rigid/ PVC heavy duty concealed conduit/ casing capping/ open coduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories, box made from not less than 1.6mm GI sheet factory made complete all as specified and as directed by Eng-In-Charge for One light point controlled by one switch complete. Note:- Cutting of wall and matching with existing surface for concealed wiring including in this item.
All as per Item No.07 above but point wiring for one fan point controlled by one switch complete.
All as per Item No.07 above but point wiring for one 3 pin socket outlet 5 Amps on the independent board.
All as per Item No.07 above but point wiring for one 3 Pin socket outlet 5 Amps on the same board.
All as per Item No. 7 above but with cable of size 4.0 Sqmm PVC insulated on independent board for power plug 15 Amps. complete all as specified and as directed by Eng-In-Charge.
S&F modular switch one way, 6A, 1 Module, complete all as specified and as directed by Eng-in-Charge.
S&F modular switch one way, 16A, 1 Module, complete all as specified and as directed by Eng-in-Charge.
S&F modular socket 6/10A, 2/3 pin, combined 2 Module complete all as specified and as directed by Eng-in-Charge.
S&F modular socket 16/15A, 2/3 pin, combined 2 Module complete all as specified and as directed by Eng-in-Charge.
S&F in repair/ replacement ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and as directed by Eng-in-Charge.
M&L for submain wiring in repair/ replacement complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through and including non metallic, rigid, PVC heavy duty surface conduit/ casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and incl sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly complete all as specified and directed by Eng-in-Charge. Note:- Two runs of 6 Sqmm cable including one run of earth wire and PVC conduit and its accessories shall be measured and paid as one length.
S&F in repair/ replacement sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links (without MCB's) 8 ways SPN complete all as directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, SPN 240 volts, 32 Amps capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, SP 240 volts,16 Amps capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in repair/ replacement MCB, single pole, 240 volts capacity, 5 Amps current rating, 10 KA breaking capacity complete all as specified and as directed by Engineer-in-Charge.
S&F white power coated fully diffuser recessed mounted 2' x 2' LED luminaire with UGR<19, offering comfortable exprience to occupants of indoor spaces conected with ceiling rose with accessoried complete all as specified and as directed. Make:- Cat No. RC38oBLED30S-6500 G4 L60 W60 PSU OD OC of make Philips or its equivalent in Bajaj/ Havells as approved by GE.
S&F green LED ultima round ultra sleelk 10 watt downlight for low height false ceiling in round profile including copper conductor connected to exiting ceiling rose complete all as specified and as directed. Make:- Cat No. DN092B LED10S - 6500 PSU WH of make Philips or its equivalent in Bajaj/ Havells as approved by GE.
Surface excavation in any type of soil n.exc 30cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
M&L for hardcore of broken stone or boulders of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick cement concrete (1:4:8) type D2 (using 40mm graded stone aggregates) as in sub bases, floor finishes and pavings complete all as specified and as directed.
M&L for 20mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for chequred cement concrete tiles design coloured 20cm x20cm x 25mm or 30cm x30cm x 25mm thick with grey cement and pigment, set jointed in neat cement slurry complete all as specified as directed.
M&L for precast cement concrete block masonry in (1:2:4) type B1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in CM 1:4 complete all as specified as directed.
M&L for preparation of new concrete surfaces of kerb stone of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Demolition cement concrete of any description and any position not otherwise specifically provided for complete all as specified and as directed.
Removing building materials etc. to a distance of 1.00 Km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregates) complete all as specified and as directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165 complete all as specified as directed.
M&L for preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm in girth or width not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide zinc primer complete all as specified as directed.
Excavating in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan and getting out in soft/ loose soil complete all as specified as directed.
Returning, filling in, includings preading, levelling, watering and well ramming in layers not exc. 25 cm thick in soft/loose soil complete all as specified as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in fondation filling and mass concrete complete all as specfied and as directed.
M&L for PCC (1:2:4) type B2 (using 40mm graded stone aggregates) as in surface channels and drains concrete complete all as specfied and as directed.
Extra for forming fair finished drain or channel 60cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. concrete complete all as specfied and as directed.
M&L for brickwork with old size fly ash bricks straight or curved on plan exc. 6m mean radius in CM (1:6) complete all as specfied and as directed.
M&L for 15mm thick cement plastering in CM (1:6) finished even and fair surfaces on walls complete all as specified and as directed.
M&L for providing precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregates) as in landings, cover slab, shelves and similar work including necessary formwork complete all as specified and as directed. Note:- (i) Minimum two holes to be provided in each precast slab and fixed with 50mm dia pvc pipe. Pipe shall be measured and paid seperatly. (ii) Reinforcement shall be measured and paid separately.
M&L for TMT bars 10 mm and over cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed.
M&L for TMT bars 6 to 8mm dia, cut to length bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F for Mild steel round bars 12mm dia and over cut to length as in guard bars conforming to Fe-410-0 complete all as specified and as directed.
S&F 50mm dia Low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ sqcm laid in trenches and precast slab complete all as specified and as directed.
M&L cement concrete (1:3:6) type C1 (using 20mm graded stone aggregates) for copings, brick work, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and as directed.
Removing excavated material exc. 1.50 km but n. exc. 5.0 km and depositing where directed for soils complete all as specified and as directed.
Surface dressing n. exc. 15 cm deep and getting out in soft loose soil complete all as speciied and as directed.
Supply, install, testing & commissioning Hi wall Split type Air Conditioner unit indoor/ outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 star rated and EER 3.2 of capacity 1.5 ton. complete all as specified and as directed.
M&L for concealed sub main wiring with two run of 4 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty conduit (ISI marked) not less than 20mm dia complete with all accessories like bends, tees, junction boxes including 4 sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire. Note:- Two runs cable incl one run of earth wire and PVC conduit and its accessories shall be measured and paid as one run length.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
ARTI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .