| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹210.2 CrAccepted-Finance | ₹210.2 Cr | L1 | Accepted-Finance L1 bidder |
| 2 | L2₹230.0 CrAccepted-Finance S 2 TECHNOCRAT INDUSTRIAL ESTATE BALANAGAR HYDERABAD 500 037 TELANGANA INDIA | HYDERABAD | HYDERABAD | TELANGANA | 500037 | ₹230.0 Cr | L2 | Accepted-Finance L2 bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Techno commercially non responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Techno commercially non responsive |
Tender Value
Refer Docs
EMD Value
₹2.4 Cr
Closing Date
24 Sept 2024, 3:30 pmClosed
SE CANDP 2
SE CANDP 2 PTCUL Dehradun
Construction of 400 KV GIS Switching Substation Pipalkoti
2024_PTCU4_74828_1
PTCUL/CandP-II/SS-08/2024-25
Open Tender
Electrical Works
570 days
Dehradun
Please refer Tender documents.
4 documents required · 4 mandatory
₹29,500
Yes
MD PTCUL
₹2.4 Cr
Yes
Dehradun
22 Feb 2025
20 Aug 2024
25 Sept 2024
20 Aug 2024
24 Sept 2024
10 Sept 2024
3 Sept 2024
Amount
Part-A (Supply)
LT Transformers
630KVA, 33/0.433kV, Three phase Transformer includign Bushings, accessories and first filling of oil.
400KVA, 11/0.433kV, Three phase Transformer includign Bushings, accessories and first filling of oil.
400 KV GIS Equipments
400KV, SF6 gas insulated Feeder Bay Module each comprising of SF6 gas insulated Circuit Breaker , Current Transformer , one Bus-Bar Disconnector with Grounding Switch and one Bus-Bar Disconnector without Grounding Switch, Line Disocnnector with Safety Grounding Switch, High Speed fault acting Earth Switch, SF6 Gas Monitoring System for complete bay, LCC and accessories with GIS etc. to complete Feeder Bay Module.
400KV, SF6 gas insualted Bus Coupler Bay Module comprising of SF6 gas insulated Cirucit Breaker , Current Transformer, two Disconnectors with Safety Grounding Switches, SF6 Gas Monitoring System for complete bay, LCC etc.
400KV, SF6 gas insulated, 3 single phase (isolated) units, metal enclosed Bus-Bars each enclosed in Bus Enclosures running along the length of the switchgear to interconnect each of Circuit Breaker Bay Module. Each Bus Bar set shall be complete with Voltage Transformer complete with Safety Grounding Switch.
400kV Single phase SF-6 ducts
400kV SF-6 / Air interface bushings
Online Partial Discharge Monitoring System for 400kV GIS
400 kV AIS equipments
400 KV CVT
Junction Box for CVT
390 KV Lightning Arrester with Counter and Leakage Meter
400 kV BPI
Miscellaneous Materials (Insulators Strings/Disc Insulator, Hardwares fittings, Conductor, 4" IPS Aluminium Tube, Cable Tray, Clamps, Connector including equipment connectors) and all accessories etc.
Complete Substation Automation System including Hardware and Software for the Substation & Remote Control Stations alongwith associated equipments as per Technical Specifications.
Bay Control Units
400kV System
Auxiliary System
Online Monitoring, Data Acquisition and ABT Analysis System
ABT meters 0.2s Cl with TCP/IP, Optical Communication Port
DCU & Accessories
Industrial Grade Network Switch -8 Port , unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation : Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition
MS office - Standard edition
MacAfee Virus Scan Enterprise Desktop Edition - Per Year
Local Energy Monitoring Software - Professional edition
Lan cable ( average one roll per S/S 300 Meters)
PVC conduit Pipe - 3/4"
Cable 3 core 2.5 Sq. mm 1.1kV copper unarmoured
Enclosure for Lan Switch
4G/5G Data enable SIM
400 KV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1 + Main 2)
Bus Bar Protection Panel
400kV Bus Bar Protection Panel for Main-1 and Main-2 Bus (Main and backup)
SDH/MUX EQUIPMENT
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 20 km
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
PLCC for 400kV Line Feeder
Line Traps
Coupling Device (Phase to Phase)
HF Cable
Carrier Equipment (for Speech+Protection and for Speech+Data)
Speech+Protection 1
Speech+Protection 2
Speech+Data
Protection Coupler
Time synchronisation equipment (GPS Clock)
Testing & Maintenance Equipments
Insulation Tester Meter 15 KV Multirange (Motorized)
Insulation Tester Meter 5 KV (Motorized)
Thermo Vision Camera
Automatic capacitor and Tan Delta measuring kit
Digital Multi meter
Leakage tester (Tong type)
Signal generator
Micro-ohm meter
Gapless zinc oxide LA tester
Oil BDV Kit 0-100 KV
Gas Evacuating and refilling Plant
Gas Leakge Monitor
Circuit Breaker Analyser
Portable Partial dischange monitoring system
Dew Point Meter
Battery Earth Fault Locator
Primary Injection Set 1000 Amp
Relay Test Kit
Gas Mask
D-Spanner set (Insulated)
Ring-Spanner set (Insulated)
Torque wrench set
Insulating gloves
Helmets
Hydraulic Ladder Battery Operated (Rechargable) upto 300kg capacity & 10 Mtrs height
Spliced ladders 5mtr.
Spliced ladders 10mtr.
Spliced ladders 20mtr.
Polyamide or Braided white nylon rope -12 mm
Polyamide or Braided white nylon rope -14 mm
Polyamide or Braided white nylon rope -20 mm
Rubber mat in Control room, Battery Room & LT Panel Room etc. as per Site requirements
Shock treatment chart & artificial respiratory system
First-aid box complete with first filling of required medicines, instruments and tools
Danger / Man on line / Break-Down boards of appropriate size
Rain coat, Gum boot and Safety Harness Belt with adequate straps
Air-conditioner and ventilation System
Split AC (Capacity-2T), Max Star rating
AHU / Ventillation system for 400 kV GIS Hall
Miscellaneous items
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
LT Switchboard
415V main switchboard
415V ACDB
220V DCDB
48V DCDB
Batteries
Battery charger system
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
DG set alongwith AMF control panel (250KVA, 440V )
Fire Protection system
Fire Detection and Alarm system for 400kv GIS Hall, Control Rooms and Other Rooms
CO2 type fire Extinguisher 9 Kgs
CO2 type fire Extinguisher 4.5Kgs
Mechanical Foam type fire Extinguisher 9 Ltrs
Bucket stand (including 4 bucket with sand fill) and sand filled drum (half size)
llumination sytem
LED Lights for Control Room / Store Room / Offices Ilumination with complete fittings
LED Lights for Switchyard Lighting with complete fittings, Junction Box & mounting accessories
Solar Light System for Street Light (LED Type Lights) with Pole and other mounting accessories
LED Lights for 400kV GIS Room, High Bay type with complete fittings in all respect
1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded Cable Sealing, Lugs, Glands and straight joints, etc.
AL Power cable (XLPE)
3.5C x 300Sq.mm
AL Power cable (PVC)
3.5C x 70Sq.mm
3.5C x 35Sq.mm
4C x 16 Sq.mm
4C x 6 Sq.mm
Copper Control Cable (PVC)
2C x 2.5Sq.mm
4C x 2.5Sq.mm
6C x 2.5Sq.mm
10C x 2.5Sq.mm
11kV Equipments
11kV panel with Circuit Breaker, CT, PT including cable termination box
11kV AB Switch
11kV Aromoured Power Cables (Al) alongwith multidiameter moulded Cable Sealing, Lugs, Glands and straight joints, etc.
Power cable Aluminium (XLPE) 400sq.mm
Termination kit for above cable (Outdoor type)
Termination kit for above cable (Indoor type) suitable for 11kV panel
33kV Aromoured Power Cables (Al) alongwith multidiameter moulded Cable Sealing, Lugs, Glands and straight joints, etc.
Power cable Aluminium (XLPE) 400sq.mm
Termination kit for above cable (Outdoor type)
Termination kit for above cable (Indoor type) suitable for 33kV panel
33kV Equipments
33kV panel with Circuit Breaker, CT, PT including cable termination box
33kV AB Switch
Grounding/Earthing System
40mm MS rod for earthmat
40mm MS 03 metre Electrodes
40mm 03 meter deep driven pipe electrode (treated pit)
GS Flats 75 x 12mm size
GS Flats 50 x 6mm size
Steel Structure
Lattice structure (Main structures, Auxiliary equipment structures and lighting mast)
Pipe structure (Auxiliary equipment structures)
EOT Crane
EOT Crane suitable for 400kV GIS
Movable ladder for suitable capacity for 400kV GIS Room
Mandatory spares as per the section "Mandatory Spares for Substation Equipments- GIS" of Technical Specification for the following items:-
a) LT Transformer for both 630 kVA and 400 kVA b) 400 KV GIS Equipments Spares i) 400 kV CB ii) 400 kV CT iii) 400 kV PT iv) 400 kV Isolators & ES c) 400 kV AIS Equipment Spares i) 400 kV CVT (3 nos.) ii) 390 kV LA (3 nos.) d) Other Spares i) llumination system ii) Optic fibre cable iii) Fire fighting iv) Battery v) Battery charger vi) Relay & protection panels vii) Substation Automation viii) LT Switchgear ix) Common spares, maintenance x) DG Set xi) 400KV GIS / Air interface Bushings (3 nos.)
Description of Work / Item(s)
Amount
Part-B (Erection)
LT Transformers
630KVA, 33/0.433kV, Three phase Transformer includign Bushings, accessories and first filling of oil.
400KVA, 11/0.433kV, Three phase Transformer includign Bushings, accessories and first filling of oil.
400 KV GIS Equipments
400KV, SF6 gas insulated Feeder Bay Module each comprising of SF6 gas insulated Circuit Breaker , Current Transformer , one Bus-Bar Disconnector with Grounding Switch and one Bus-Bar Disconnector without Grounding Switch, Line Disocnnector with Safety Grounding Switch, High Speed fault acting Earth Switch, SF6 Gas Monitoring System for complete bay, LCC and accessories with GIS etc. to complete Feeder Bay Module.
400KV, SF6 gas insualted Bus Coupler Bay Module comprising of SF6 gas insulated Cirucit Breaker , Current Transformer, two Disconnectors with Safety Grounding Switches, SF6 Gas Monitoring System for complete bay, LCC etc.
400KV, SF6 gas insulated, 3 single phase (isolated) units, metal enclosed Bus-Bars each enclosed in Bus Enclosures running along the length of the switchgear to interconnect each of Circuit Breaker Bay Module. Each Bus Bar set shall be complete with Voltage Transformer complete with Safety Grounding Switch.
400kV Single phase SF-6 ducts
400kV SF-6 / Air interface bushings
Online Partial Discharge Monitoring System for 400kV GIS
400 kV AIS equipments
400 KV CVT
Junction Box for CVT
390 KV Lightning Arrester with Counter and Leakage Meter
400 kV BPI
Miscellaneous Materials (Insulators Strings/Disc Insulator, Hardwares fittings, Conductor, 4" IPS Aluminium Tube, Cable Tray, Clamps, Connector including equipment connectors) and all accessories etc.
Complete Substation Automation System including Hardware and Software for the Substation & Remote Control Stations alongwith associated equipments as per Technical Specifications.
Bay Control Units
400kV System
Auxiliary System
Online Monitoring, Data Acquisition and ABT Analysis System
ABT meters 0.2s Cl with TCP/IP, Optical Communication Port
DCU & Accessories
Industrial Grade Network Switch -8 Port , unmanaged
UPS 2 KVA online with 30 Min back up on 100% load
Workstation : Application & Database server
Database - Microsoft SQL Server 2016 STANDARD Edition
MS office - Standard edition
MacAfee Virus Scan Enterprise Desktop Edition - Per Year
Local Energy Monitoring Software - Professional edition
Lan cable ( average one roll per S/S 300 Meters)
PVC conduit Pipe - 3/4"
Cable 3 core 2.5 Sq. mm 1.1kV copper unarmoured
Enclosure for Lan Switch
4G/5G Data enable SIM
Integration of Station Metering System with centrlized Data system including all Hardware and Software required.
400 KV Control and Relay panel
Circuit Breaker Control Panel
With Auto Reclose
With out Auto Reclose
Line Protection Panel (Main 1 + Main 2)
Bus Bar Protection Panel
400kV Bus Bar Protection Panel for Main-1 and Main-2 Bus (Main and backup)
SDH/MUX EQUIPMENT
Steel Cabinet with all internal wiring/terminations/MDF and arrangement for dual 48/50V Power supply input
SDH (STM-4 upgradable upto STM-16)/MUX base 19" equipment rack (incl. front cover, cable tray, common cards such as redundant CPU) with arrangement for dual input power supply.
OLTE - 4 Port STM-1 (155 Mbps) Card excluding SFPs
SFP module to support upto 20 km
SFP module to support upto 50 km
SFP module to support upto 100 km
Optical Amplifier/Booster equipment
OFC Patch Cords - (Set of 12 Nos.)
Ethernet over SDH (STM-4 upgradable upto STM-16) transport card (with eight 10/100/1000BaseT interfaces)
Minimum 8 Port E1 interface card
Minimum 8 Port 4w E&M Interface card
Minimum 12 Port FXO interface card
Minimum 10 Port FXS interface card
Minimum 4 Port programmable data interface card
Integrated Teleprotection card (4 Commands each)
Engineering Order Wire Phone
Optical Fibre Cable for above OPGW communication
PLCC for 400kV Line Feeder
Line Traps
Coupling Device (Phase to Phase)
HF Cable
Carrier Equipment (for Speech+Protection and for Speech+Data)
Speech+Protection 1
Speech+Protection 2
Speech+Data
Protection Coupler
Time synchronisation equipment (GPS Clock)
Air-conditioner and ventilation System
Split AC (Capacity-2T), Max Star rating
AHU / Ventillation system for 400 kV GIS Hall
Miscellaneous items
Air Curtain for Control Room Building
Interactive Screen for Control Room Building
LT Switchboard
415V main switchboard
415V ACDB
220V DCDB
48V DCDB
Batteries
Battery charger system
220V, 100Amps Float Cum Boost Charger
48V, 60Amps Float Cum Boost Charger
DG set alongwith AMF control panel (250KVA, 440V )
Fire Protection system
Fire Detection and Alarm system for 400kv GIS Hall, Control Rooms and Other Rooms
Bucket stand (including 4 bucket with sand fill) and sand filled drum (half size)
llumination sytem
LED Lights for Control Room / Store Room / Offices Ilumination with complete fittings
LED Lights for Switchyard Lighting with complete fittings, Junction Box & mounting accessories
Solar Light System for Street Light (LED Type Lights) with Pole and other mounting accessories
LED Lights for 400kV GIS Room, High Bay type with complete fittings in all respect
1.1kV Aromoured Power Cables (Al) and Aromoured Control Cables (Copper) alongwith multidiameter moulded Cable Sealing, Lugs, Glands and straight joints, etc.
AL Power cable (XLPE)
3.5C x 300Sq.mm
AL Power cable (PVC)
3.5C x 70Sq.mm
3.5C x 35Sq.mm
4C x 16 Sq.mm
4C x 6 Sq.mm
Copper Control Cable (PVC)
2C x 2.5Sq.mm
4C x 2.5Sq.mm
6C x 2.5Sq.mm
10C x 2.5Sq.mm
11kV Equipments
11kV panel with Circuit Breaker, CT, PT including cable termination box
11kV AB Switch
11kV Aromoured Power Cables (Al) alongwith multidiameter moulded Cable Sealing, Lugs, Glands and straight joints, etc.
Power cable Aluminium (XLPE) 400sq.mm
Termination kit for above cable (Outdoor type)
Termination kit for above cable (Indoor type) suitable for 11kV panel
33kV Aromoured Power Cables (Al) alongwith multidiameter moulded Cable Sealing, Lugs, Glands and straight joints, etc.
Power cable Aluminium (XLPE) 400sq.mm
Termination kit for above cable (Outdoor type)
Termination kit for above cable (Indoor type) suitable for 33kV panel
33kV Equipments
33kV panel with Circuit Breaker, CT, PT including cable termination box
33kV AB Switch
Grounding/Earthing System
40mm MS rod for earthmat
40mm MS 03 metre Electrodes
40mm 03 meter deep driven pipe electrode (treated pit)
GS Flats 75 x 12mm size
GS Flats 50 x 6mm size
Steel Structure
Lattice structure (Main structures, Auxiliary equipment structures and lighting mast)
Pipe structure (Auxiliary equipment structures)
EOT Crane
EOT Crane suitable for 400kV GIS
Support for Operation and Maintenance (O&M) of Substation, Trouble shooting and familarization of PTCUL staff with the installed system for a period of 06 (Six) Months by deploying adequate number (Minimum 02) of qualified persons round the clock.
Part-B ( Civil Works)
Buildings
Construction of 400 KV GIS room and Cable Vault (Plinth area to be measured)
(i) GIS Hall
(ii) Cabe Vault ( Room height 2.40 m)
Construction of 400 KV GIS Relay room
Construction of Control room cum Administartive building including provision of ACDB,SWGR, El. Lab, locker, Battery room , Panel room, SCADA, MGR, Staff room, office & pantry etc. (Plinth area to be measured)
Construction of Store shed including (Plinth area to be measured)
Construction of Annexe building (Plinth area to be measured)
Construction of foundation of following structures including excavation and back filling of earth, CC/RCC works, reinforcement , supply & Fixing of bolts etc. complete.
Main Gantry foundation 400 KV
CVT foundation 400 KV
LA foundation 400 KV
Bushing foundation (Air to SF 6 Interface) 400 KV
BPI/WT foundation 400 KV
Foundation for Duct support structure 400 KV
Foundation for Lightening Mast
Plinth for Auxilary Transformer
Construction of DG set plinth
AC junction box for Switchyard lighting
RCC Cable trenches with trench covers (all Sections) including all type of crossing and all matelic work to support cables and trench covers.
300 mm size trench with minimum depth 600 mm
600 mm size trench with minimum depth 600 mm
1000 mm size trench with minimum depth 1000 mm
Construction of one sump with suitable capacity sludge pump and pumphouse ,control panel for drainage of water from cable trenches, also including supply of one spare pump.
Cement concrete roads including all type of crossings.
5.00 metre wide
3.75 metre wide
1.20 metre wide
Secuirty Fencing 3.6 m high alongwith Gate and Guardroom
Secuirty Fencing 3.6 m high (Chain link)
Security guard room with attached toilet etc. (Minimum area 15 Sqm)
Boundary wall 2.40 m high with 0.60 m concertina coil fenced at top along the periphery of substation land including foundation of boundary wall cloumn , toe wall below plinth beam upto a height of .60 meter, construction of main gate & providing necessary sign boards at the entrance etc.
Storm water drainage including culverts.
Switch yard turfing including levelling , antiweed treatment ,dressing of area,preparation of subgrade, and supplying/laying of 100 mm thick PCC (1:4:8) and 100 mm thick layer of stone ballast 40 mm single size over PCC including the cost of all material and labour, T &P etc complete as per detailed civil specification.
Tubewell / water supply scheme having minimun discharge 150 LPM (or as decided by engineer in charge) with RCC water storage tank 100 KL capacity & connecting pipeline including Pump house etc.
Horticulture operations including 300mm earth filling, grassing, tree plantation/shrubs and potted plant etc.
Rain Water Harvesing (RWH) (4 x 12)
Land development including necessary cutting /filling and construction of all retaining walls for complete switch yard area maintaing required terraces levels
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth.,1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil DSR-2.6.1
Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.All Kinds of soil. (DSR-2.8.1)
Carriage of earth by mechanical transport, including loading unloading and stacking (DSR 1.1.2) carriage upto 1 km distance
Extra for every additional lift of 1.5 m or part thereof in. All kinds of soil. DSR 2.26.1
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (DSR-4.1.8)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 (1cement :2 coarse sand:4graded stone aggregate 20mm nominal size) (DSR-4.1.3)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: 1:1:5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size).(DSR-5.1.2)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement. 1:1:5:3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 cm nominal size).(DSR-5.2.2)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (DSR-5.3)
Centering and shuttering including strutting propping etc. and removal of form for: Foundations footings, bases of columns, etc. For mass concrete.(DSR-5.9.1)
Centering and shuttering including strutting propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (DSR-5.9.2)
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Cold Twisted bars. DSR-5.22.3
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ( DSR : 7.1.1)
P/F PVC pipe 110 mm dia 4Kg/cm2 (DSR 12.41.2)
Slope Stablization
Excavation and Slope profile preparation
Slope profile preparation as per drawing using mechanical excavator in normal soil.
Slope profile preparation as per drawing using mechanical excavator in hard rock.
Soil Nailing using 32 mm SDA
For section height 1m to 5m shotcrete the facia of the cut slope in one layer up to 50 mm thickness using (1 cement:1.5 coarse sand:3 pea size i.e. 6 mm down size coarse aggregates) including supply and installation of R32 SDA anchors and wire mesh drilling of 50 mm dia hole, and installation of SDA and grouting of anchors with neat cement grout using water cement ratio 0.5 to 0.60 along with supply and fixing of MS bearing plate tightens with nut.
For section height 1m to 10 m shotcrete the facia of the cut slope in one layer up to 50 mm thickness using (1 cement:1.5 coarse sand:3 pea size i.e. 6 mm down size coarse aggregates) including supply and installation of R32 SDA anchors and wire mesh drilling of 50 mm dia hole, and installation of SDA and grouting of anchors with neat cement grout using water cement ratio 0.50 to 0.60 along with supply and fixing of MS bearing plate tightens with nut.
For section height 1m to 15 m excavated slope facia is protected by vegetation with jute and wire mesh including supply and installation of R32 SDA anchors drilling of 50 mm dia hole, and installation of SDA and grouting of anchors with neat cement grout using water cement ratio 0.50 to 0.60 along with supply and fixing of MS bearing plate tightens with nut.
For section height 1m to 20 m excavated slope facia is protected by vegetation with jute and wire mesh including supply and installation of R32 SDA anchors drilling of 50 mm dia hole, and installation of SDA and grouting of anchors with neat cement grout using water cement ratio 0.50 to 0.60 along with supply and fixing of MS bearing plate tightens with nut.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR-2.25)
Description of Work / Item(s)
Amount
Total Part-A (Supply) from BoQ1 sheet WITHOUT GST
Total Part-B (Erection and Civil Works) from BoQ2 sheet WITHOUT GST
Add GST* Amount on (Total of Part-A + Total of Part-B above)
M/S. Megha Engineering and Infrastructures Limited
M/S. Megha Engineering and Infrastructures Limited
M/S. Megha Engineering and Infrastructures Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.