Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC D S ELECTRICALS D S MANDIRAM SREEVARAHAM VALLAKADAVU P O TRIVANDRUM | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 ACCEPTED | |
| 2 | L2₹37.9 L+₹7,274 (0.19%)Rejected-AOC | L2 | Rejected-AOC L2 REJECTED |
| Sl No | Description | Qty | Unit | D SURESH L1 | Best Power Controls L2 |
|---|---|---|---|---|---|
| 1.00SITC of UPS | |||||
| 1.00 | OD97059/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 5 KVA, Single phase in and single phase out UPS with zero transfer time, DSP based control , IGBT rectifier and IGBT inverter, provision for enhancing UPS capacity by operating UPS in N+X parallel (Up to 4 systems), RS232 port, input PF> 0.99@ full load, unity output PF (5KVA=5KW), input voltage range 160V- 280V with auto cut off, THD </= 10%, overall efficiency (AC to AC) >/= 94% , Display panel (in-built LCD and LED) with all measurements and fault indication and LED indications, Audible alarms for: "replace battery, overload warning and shutdown, Low battery, High temperature warning and shutdown". Suitable for operation in 0-40 degree Celsius ambient Temperature with a noise level<50 dbA at 1m distance and noise level should reduce with load., Generator compatibility, pure sine wave , Battery overcharge and undercharge cut off , Cold start, Automatic restart, self diagnosis, Automatic Bypass arrangement. The UPS system shall include necessary parallel kit and all battery accessories including MS open racks complete with interconnections. The system shall comply with IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS and relevant IS standards. All relevant type test certificates shall be provided and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. UPS Make : Delta, Legrand- Numeric, Hykon or equivalent make) , Battery Make : Exide EL / Amaron Quanta, c10 Battery suitable for a minimum VAH of 15840 | 8 | each | 2,49,000 ₹19,92,000 | 2,43,600 ₹19,48,800 Lowest |
| 1.00 | OD97504/2025-2026:Supply, installation, testing, and commissioning of a continuous duty, true online configuration with double conversion 3-phase online UPS System of 30 kVA with an input isolation transformer. The model shall have the capability to enhance UPS capacity/redundancy by operating the UPS in N+X Parallel Redundant Configuration (PRS configuration) and shall have the capability of independent or common battery bank operation of the UPS when operated in PRS. The UPS system shall be of indoor type (IP20) with input isolation transformer surge protection system, input PF > 0.99, input THDi 93% and unity output power factor (30 kVA = 30 kW), and including all accessories, etc., as required.
The UPS shall have zero ms transfer time from mains mode to battery mode and battery mode to mains mode, and automatic bypass built-in with transfer time < 1ms, and shall have manual maintenance bypass provisions, cold start capability, and serial communication interface RS232 port. The system shall have IGBT rectifier and inverter, suitable for operation in 0-40°C ambient temperature with a noise level < 56 dBA at 1m distance. The UPS control panel shall be a color graphic LCD display for indication of UPS status, metering, battery status, alarm/event log, and advanced operational features, including audible alarms. The unit shall have battery backup with a minimum VAH of 72,000 using tubular C10 batteries, including battery rack and interconnecting cables.
The system shall comply with IEC/EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS, and relevant IS standards. All relevant type test certificates shall be provided, and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. Make of UPS: Legrand-Numeric/ Riello/ Delta/ Vertiv or equivalent make. Make of Battery: Amaron Quanta/ Exide EL. | 1 | each | 11,95,950 ₹11,95,950 | 11,78,000 ₹11,78,000 Lowest |
| 1.00 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | 8 | each | 2,546 ₹20,368 Lowest | 2,724 ₹21,792 |
| 1.00 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) | 1 | each | 2,715 ₹2,715 Lowest | 3,200 ₹3,200 |
| 1.00 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 76 | each | 272 ₹20,672 | 270 ₹20,520 Lowest |
| 1.01 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 8 | each | 477 ₹3,816 | 459 ₹3,672 Lowest |
| 1.01 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 3,500 ₹3,500 | 3,037 ₹3,037 Lowest |
| 1.01 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | 8 | each | 2,230 ₹17,840 Lowest | 2,386 ₹19,088 |
| 1.01 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 16 | each | 1,290 ₹20,640 | 1,236 ₹19,776 Lowest |
Tender Value
₹39.4 L
EMD Value
₹50,000
Closing Date
17 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of Executive Engineer, PWD Electrical Division, Thiruvananthapuram 695033
DEPOSIT Neyyattinkara Thaluk and Village offices UPS Installation Providing UPS in Neyyattinkara Taluk office and 8 nos Village offices jurisdiction under Neyyanttinkara Thaluk as part of the E Office implementation General Electrical Work
2025_PWD_775520_1
EDT_ET_17_2025_26
Open Tender
Electrical Works
Item Rate
120 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
24 Sept 2025
8 Jul 2025
21 Jul 2025
8 Jul 2025
17 Jul 2025
8 Jul 2025
Amount
SITC of UPS
OD97059/2025-2026:Supply, installation, testing and commissioning of True online, Double Conversion 5 KVA, Single phase in and single phase out UPS with zero transfer time, DSP based control , IGBT rectifier and IGBT inverter, provision for enhancing UPS capacity by operating UPS in N+X parallel (Up to 4 systems), RS232 port, input PF> 0.99@ full load, unity output PF (5KVA=5KW), input voltage range 160V- 280V with auto cut off, THD </= 10%, overall efficiency (AC to AC) >/= 94% , Display panel (in-built LCD and LED) with all measurements and fault indication and LED indications, Audible alarms for: "replace battery, overload warning and shutdown, Low battery, High temperature warning and shutdown". Suitable for operation in 0-40 degree Celsius ambient Temperature with a noise level<50 dbA at 1m distance and noise level should reduce with load., Generator compatibility, pure sine wave , Battery overcharge and undercharge cut off , Cold start, Automatic restart, self diagnosis, Automatic Bypass arrangement. The UPS system shall include necessary parallel kit and all battery accessories including MS open racks complete with interconnections. The system shall comply with IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS and relevant IS standards. All relevant type test certificates shall be provided and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. UPS Make : Delta, Legrand- Numeric, Hykon or equivalent make) , Battery Make : Exide EL / Amaron Quanta, c10 Battery suitable for a minimum VAH of 15840
OD97504/2025-2026:Supply, installation, testing, and commissioning of a continuous duty, true online configuration with double conversion 3-phase online UPS System of 30 kVA with an input isolation transformer. The model shall have the capability to enhance UPS capacity/redundancy by operating the UPS in N+X Parallel Redundant Configuration (PRS configuration) and shall have the capability of independent or common battery bank operation of the UPS when operated in PRS. The UPS system shall be of indoor type (IP20) with input isolation transformer surge protection system, input PF > 0.99, input THDi 93% and unity output power factor (30 kVA = 30 kW), and including all accessories, etc., as required. The UPS shall have zero ms transfer time from mains mode to battery mode and battery mode to mains mode, and automatic bypass built-in with transfer time < 1ms, and shall have manual maintenance bypass provisions, cold start capability, and serial communication interface RS232 port. The system shall have IGBT rectifier and inverter, suitable for operation in 0-40°C ambient temperature with a noise level < 56 dBA at 1m distance. The UPS control panel shall be a color graphic LCD display for indication of UPS status, metering, battery status, alarm/event log, and advanced operational features, including audible alarms. The unit shall have battery backup with a minimum VAH of 72,000 using tubular C10 batteries, including battery rack and interconnecting cables. The system shall comply with IEC/EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS, and relevant IS standards. All relevant type test certificates shall be provided, and the UPS system shall include a minimum warranty of 3 years for UPS and 4 years for battery. Make of UPS: Legrand-Numeric/ Riello/ Delta/ Vertiv or equivalent make. Make of Battery: Amaron Quanta/ Exide EL.
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
OD267930/2023-2024:Supplying and fixing four pole sheet steel enclosure on surface/ recess and giving connections as required
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD267931/2023-2024:Supplying and clamping 20 mm sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required
5.11:Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Best Power Controls (BID ID -2253172)
Bidder Name
D SURESH
Best Power Controls
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1267584.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .