Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 CrAccepted-AOC | ₹17.0 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹17.4 CrRejected-AOC | ₹17.4 Cr | L2 | Rejected-AOC OTHER THAN LOWEST |
| 3 | L3₹18.4 CrRejected-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹18.4 Cr | L3 | Rejected-AOC OTHER THAN LOWEST |
| 4 | L4₹21.0 CrRejected-AOC | ₹21.0 Cr | L4 | Rejected-AOC OTHER THAN LOWEST |
| 5 | L5₹21.2 CrRejected-AOC C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹21.2 Cr | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹17.5 Cr
EMD Value
₹12 L
Closing Date
23 Aug 2021, 6:00 pmClosed
CHIEF ENGINEER CHANDIGARH ZONE
CHIEF ENGINEER HQ CE CHANDIGARH ZONE CHANDIGARH 160003
PROVISION OF KLP ACCN FOR COMPOSITE ARTY BDE AT AMBALA CANTT
2021_MES_441942_1
CA NO. CECHZ/AMB/T-02/2021-22
Open Tender
Civil Works
756 days
AMBALA
As per tender documents
10 documents required · 10 mandatory
₹3,000
GE P AMBALA
₹12 L
Yes
8 Oct 2021
13 May 2021
25 Aug 2021
13 May 2021
23 Aug 2021
16 Aug 2021
14 May 2021 - 21 May 2021
Amount
Schedule 'A'Section-I (Building Works)
Lump sum price worked out by the Contractor for "Building Work" as listed in Sch 'A' Sec I
Schedule 'A'Section-II (Site Clearance And Devolpment & Earthwork)
Lump sum price worked out by the Contractor for "Site Clearance And Devolpment & Earthwork" as listed in Sch 'A' Sec II
Schedule 'A'Section-III (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for "Internal Electrification Works" as listed in Sch 'A' Sec III
Schedule 'A'Section-IV (INTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "Internal water supply works" as listed in Sch 'A' Sec IV
Schedule 'A'Section-V ( HOT WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "Hot water supply works" as listed in Sch 'A' Sec V
Schedule 'A'Section-VI (SEWAGE DISPOSAL WORKS
Lump sum price worked out by the Contractor for "Sewage Disposal Works" as listed in Sch 'A' Sec VI
Schedule 'A'Section-VII (AREA DRAINAGE WORKS)
Lump sum price worked out by the Contractor for "Area Drainage Works" as listed in Sch 'A' Sec VII
Schedule 'A'Section-VIII (ROAD PATH & CULVERTS WORKS)
Lump sum price worked out by the Contractor for "Road Path & Culverts Works" as listed in Sch 'A' Sec VIII
Schedule 'A'Section-IX (SECURITY WALL & SECURITY FENCING WORKS)
Lump sum price worked out by the Contractor for "Security Wall and Security Fencing Works" as listed in Sch 'A' Sec IX
Schedule 'A'Section-X (EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "External water supply works" as listed in Sch 'A' Sec X
Schedule 'A'Section-XI (LIGHTENING PROTECTION WORKS)
Lump sum price worked out by the Contractor for "Lightening protection works" as listed in Sch 'A' Sec XI
Schedule 'A'Section-XII (EXTERNAL ELECTRIC SUPPLY WORKS)
Lump sum price worked out by the Contractor for "External electric supply works" as listed in Sch 'A' Sec XII
Schedule 'A'Section-XIII (CONDUIT FOR TV/TELEPHONE /INTERCOM /LAN WORKS)
Lump sum price worked out by the Contractor for "Conduit for TV/Telephone/intercom/lan works" as listed in Sch 'A' Sec XIII
Schedule 'A'Section-XIV ( PLAYGROUNDS AND HARD STANDING WORKS)
Lump sum price worked out by the Contractor for "Playgrounds and hard standing works" as listed in Sch 'A' Sec XIV
Schedule 'A'Section-XV ( ALUMINIUM PARTITION AND ALLIED WORKS)
Lump sum price worked out by the Contractor for "Aluminium partition and allied works" as listed in Sch 'A' Sec XV
Schedule 'A'Section-XVI ( DEMOLITION / DISMANTLING WORKS)
Lump sum price worked out by the Contractor for "Demolition/dismantlng works" as listed in Sch 'A' Sec XVI
Schedule 'A'Section-XVIII(Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
INTERNAL ELECTRIC SUPPLY WORKS
Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, flame retardant low smoke (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty PVC concealed conduit and its fittings, ISI marked, PVC junction boxes, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLSH) PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified, for the following: -
(a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator and one bell point controlled by one bell push
(b) One 3 pin 5 Amps socket outlet on independent board
(c ) One 3 pin 5 Amps socket outlet on same board
One socket outlet point, 16 Amp, independent, with 2.5 sqmm (nominal area) cable for phase & neutral and 2.5 sqmm (nominal area) cable as earth continuity conductor.
All as per item ser No 35 hereinbefore but one light point controlled by two 2 way switches.
Point wiring for flame proof light fitting using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, flame retardant low smoke (FRLSH), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including heavy duty steel conduit and its fittings, ISI marked, mild steel sunken boxes (Terminal boxes) with earth dolly, duly painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLSH) PVC insulated unsheathed stranded copper conductor 1.5 Sq. mm (nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified.
Sub main wiring using approved colour coding as per IS with five single core, PVC insulated, unsheathed FRLSH multistranded copper conductor cables of size 10.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and directed. Note: (i) Five runs each of one RM of 10.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLSH multistranded copper conductor cables of size 6.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: (i) Three runs each of one RM of 6.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLSH multistrand copper conductor cables of size 4 Sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: Three runs each of one RM of 4.0 Sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp ( For AC ) complete all as specified and as directed
Sheet metal enclosure MCB DB, 12 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 8 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 4 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 4 ways TPN, 415 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete suitable for with 200 Amp rated bus bar complete all as specified and as directed.
MCB SP, 230volt , 50 Hzs, 6 to 32 A, 10 KA , "B" series complete all as specified and directed.
MCB SPN, B Curve as incommer, 220 volt , 50 Hzs, 16 Amps, 10 KA ,complete all as specified and directed.
MCB SPN, B Curve as incommer, 220 volt , 50 Hzs, 20/25 Amps, 10 KA ,complete all as specified and directed.
MCB SPN, B Curve as incommer, 220 volt , 50 Hzs, 32 Amps, 10 KA ,complete all as specified and directed.
MCB SPN, B Curve as incommer, 220 volt , 50 Hzs, 40 Amps, 10 KA , complete all as specified and directed.
MCB TPN 4 pole, B Curve as incommer, 415 volt , 50 Hzs, 63 Amps, 10 KA ,complete all as specified and as directed.
MCB TPN 4 pole, B Curve as incommer, 415 volt , 50 Hzs, 40 Amps, 10 KA ,complete all as specified and as directed
MCCB TPN as incommer, 440 volt , 50 Hzs, 100 Amps, 16 KA , complete all as specified and directed.
Ceiling fan AC single phase 240 Volt 50 Hz of size 1200 mm sweep complete in white colour having service value more than or equal to 4 with canopy and hanging rod with all accessories incl nuts,bolts,clamps etc, complete all as specified and directed
Exhaust fan 300 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
Fan regulator 2 Module stepped type (electronic ) made of polycarbonate/remote control suitable for 1200/1400mm sweep AC ceiling fan complete all as specified and directed.
LED bulb 10 watt 230 volts AC 50 Hz Retrofit B22 base for lamp holder complete all as specified and directed.
LED tube light fitting ,1x18/20 watt LED 230v energy efficent Batten fitting, with Driver etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible cable copper conductor including 18/20 watt LED tube rod complete all as specified and directed.
Sheet metal enclosure MCB DB 6 way SPN, 240 volts, IP-43 protection, double door type grouting in wall in CM 1:3, flush mounted complete with 200 Amps rated bus bar complete all as specified and directed.
Sheet metal enclosure, loadline vertical DB, TPN 415 volts, 4 way, IP-43 protection suitable for incomer MCCB upto 125A with provision of insulated busbar assembly of suitable capacity, double door type, grouting in wall in CM incl all electrical connections complete all as specified and directed.
Switch flame proof rotary type with termination box in LM6, 16 Amp, single pole 250 Volts complete all as specified and directed.
Building Security Light Pressure die cast housing with epoxy power coated dark graphite grey colour finish. Prismatic polycarbonate cover with individual LED lenses. IP65, 20 Watt with GI pipe bracket of size 40mm dia light grade 1.2 mtr long bent to shape fixed on wall etc with clamps,nut,bolt,washer etc complete all as specified and directed.
Surface mounted wall Mirror LED light Compact & sturdy 9 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects,
Flame proof -weather proof Led tube fittings,2X20 Watt,4 feet long LM-6 body,with two Nos cable entries and one entry plugged with proper flame proof plug, terminal block, wire guard, porcelain lamp holder heat resistant glass IP 65 protection including 2Nos LED tube 20 watt 4 feet and necessary flame proof flexible metallic conduit tested by CMRS Dhanbad and CCOE (PESO) Nagpur conforming to IS 2069 (PartI)of 1984 complete, all as specified and directed by Engineer-in-Charge.
ROAD, PATH AND CULVERTS
Bringing approved earth from outside MoD land including cost of earth and carriage complete, all as specified and directed by Engineer-in-Charge.
Providing, Laying, compaction of granular sub-base by providing close graded Material conforming to specifications i.e Grading II, conforming to Clause 401 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of capacity 8 to 12 tonne to achieve the desired density, 150 mm thick compacted thickness, complete all as specified and directed by Engr-in-Charge.
Providing, Laying. compaction of Wet Mix Macadam conforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregates as per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge. NOTES: 1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness). 2. For payment purpose,both layers shall be considered as one unit.
Preparation of un-surfaced Wet Mix macadam (WMM) surfaces by sweeping clean by power broom or mechanical sweepers and removing completely all loose material and other foreign material and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed by Engineer-in-Charge.
Providing, laying & compaction of Bituminous Macadam (BM) 50 mm Compacted thickness conforming to Clause 504 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc. of grading II as per Table 500-7 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed by Engineer-in-Charge. Notes : (i) The contractor shall quote the rate against Item considering 3.5% VG-30 bitumen content. Mix Design for bituminous macadam shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less than 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision). (ii) If qty of binder contents is less than the qty as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumenand if qty of binder contents is more than the qty as specified in respective items of BOQ no adjustment shall be made.
Preparation of bituminous surfaces and applying evenly a Tack coat conforming to Clause 503 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed by Engineer-in-Charge.
Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete (BC) layer conforming to clause 507 of MoRT&H specifications for road and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc, cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant (Batch Type) of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engineer-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed by Engr-in-Charge.
60mm thick machine pressed precast concrete (of M-35 grade) interlocking paver block, manufactured in an automatic plant working on vibration and simultaneous hydraulic compression from top, (with grey cement and pigment) any shape and size confirming to IS 15658-2006 laid over and including 50mm thick cushion of coarse sand & filling the joints after laying complete all as specified and as directed.
Hot applied thermoplastic road marking inclusive type I reflectorising glass beads as per table 800-3, 800-4 of MORTH applied in uniform thickness of at least 1.5mm and spread uniformly with reflectorising glass beads type-II @ 250 gms per sqm with a road marking machine as per IRC:35,in white or golden yellow colour with traffic diversion arrangemets if required, complete all as specified and as directed.
Road stud / cat eye ABS material body of size 100x100x20mm with two highly reflective reflectors fitted in the body, fixed with MS pin & approved epoxy adhesive as per manufacturer instruction on road , of colour as directed complete all as specified and as directed.
Road safety convex mirror 80cm dia. for road safety and shop security with adjustable brackets fixed on MS tube of size 60mm dia medium grade duly painted powder coated , 1.2m high fixed in PCC as per manufacturer instruction on road side or as directed complete all as specified .
Solar road stud of size 128x134x20-25mm made from aluminium alloy and construction , solar powered by mono crystal solar panel with one high capacity Ni-Cd rechargeable battery to be fixed on road with approved epoxy adhesive as per manufacturer instruction of colour Red/ amber/green as desired complete all as specified and as directed.
Readymade ABS plastic speed breaker / speed bumps of size 350x250x50mm designed so dynamically and compact to bear max load , with reflectors moulded in PMMA material to be fixed on road as per manufacturer instruction complete all as specified and as directed.
COMPOUND/SECURITY WALL FENCING & GATE / GROUND AND HARD STANDING
Preparing newly plastered surface of wall / concrete surfaces of any description over 10cm width or girth and applying two coats of exterior emulsion paint over a coat of primer of approved shade / tint complete all as specified and directed
INTERNAL WATER SUPPLY WORKS
Wall mixer cast copper alloy with bend pipe for overhead shower for 'Hot or Cold' screweddown for 15mm bore iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
Central hole basin mixer cast copper alloy with 450mm braided connection pipe ( without pop up ) , fancy type chromium plated screwed down, high pressure, with or without lettered 'Hot or Cold' screwed for 15mm bore iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
Sink mixer ( wall mounted ) cast copper alloy with 150mm long swivel spout , connecting legs and wall flanges , fancy type chromium plated screwed down, high pressure, with or without lettered 'Hot or Cold' screwed for 15mm bore iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
LIGHTENING PROTECTION
Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including 4 mm galvanised earth lead wire as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanised iron, 20 mm bore (medium grade) GI pipe for protection of earthing lead, 20 mm bore (medium grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 5 of SSR Part-I (1991). Note : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. 2. The unit rate includes for protecton pipe 20mm and GI earth wire 4mm from top of earth plate upto 7.50 metre above ground level.
CONDUIT FOR TV /TELEPHONE /INTERCOMM/LAN
Socket outlet for Tele/LAN piano flush type ISI marked with valid CML No complete all as specified and directed.
Socket outlet for TV piano flush type ISI marked with valid CML No complete all as specified and directed.
SUMMER APPLIANCES
Supply installation commissioning of Refrigerators electric driven (single phase) of capacity 242 letres or nearest capacity as approved by GE frost free five star rating complete all as specified and directed .
Supply installation commissioning of hard top Deep freezer single phase 240 Volts 50 HZs of cap 120 Ltrs complete all as specified and directed.
Supply, instalation, testing and commissiong of Water cooler partially stainless steel electric driven single phase having approx storage and nominal cooling cap 80/40 ltr complete all as specified and directed.
Supply and installation of Desert cooler electric driven (single phase) with outer body made of PGI (Plain Galvanised Iron) sheet not less than 1.20 mm thickness for fixed part,thickness of PGI (Plain Galvanised Iron) sheet for shutter not less than 0.80 mm thickness,front grill made of PGI (Plain Galvanised Iron) sheet with minimum weight 2.80 kgs,overall outer size not less than 66 cm X 66 cm X 99 cm (Height) ,copper wounded fan motor having nominal air flow capacity of 4000 cum per hour and submersible pump for required flow of water complete all as specified and directed.
Supply,installation, testing and commissioning air cooled split unit Air Conditioner electric driven single phase of cap 1.5 TR having EER star rating not less then 4.5 (WW) , inverter type complete all as specified and directed. Note:- Cost of stand for outdoor unit , copper pipe, insulation material for copper pipe and drainout pipe from indoor unit to outside building is inclusive in the unit rate of item quoted by contractor.
Supply, installation, testing and commissionig air cooled split unit Air Conditioner electric driven single phase of cap 2.0 TR having EER rating not less than 4.5 (WW) inverter type complete all as specified and directed. Note:- Cost of stand for outdoor unit , copper pipe, insulation material for copper pipe and drainout pipe from indoor unit to outside building is inclusive in the unit rate of item quoted by contractor.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V copper wound with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 1 KVA.complete all as specified and directed.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V copper wound with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 4 KVA complete all as specified and directed
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V copper wound with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity 5 KVA complete all as specified and directed
EXTERNAL WATER SUPPLY
Centrifugly cast ductile iron pressure pipe with socket spigot ends ISI marked in standard length of 5.5 or 6 mtr of class K-7 for push on joint (Gasket D jointing) with cement mortar lining in pipe of size 100 mm bore including material and labour for making push on joints complete all as specified and directed..
Construction of brick masonary valve pit of 900 mm x 900mm x900mm (internal size) with 3mm thick mild steel sheet cover and angle iron frame of size 40mm x 40mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer on MS cover & frame including necessary excavation , returning , filling , removal , plastering in CM 1:4 internally and externally complete all as specified and as directed.
All as per Ser item No.108 above but of size 600 mm x 600mm x600mm (internal size)
Ductile iron fittings such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket/spigot caps and plugs suitable upto 200 mm bore ductile iron pressure pipes of K-9 classification and push on flexible rubber gasket joints complete all as specified.
Sluice valve, 100 mm bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS 14846-2000 complete all as specified and directed.
Sluice valve, 80 mm bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS 14846-2000 complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY WORKS
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) 95 sqmm 3 core ,earthed system, stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 11000 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 240 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 185 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 70 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 50 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 35 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 25 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 16 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 10 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 6 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
Supply, install, commissioning testing of transformer step down 11KV/433V outdoor type copper wound 315 KVA Cap (Energy efficiency level 1) with necessary, standard fittings of capacity 315 KVA 3 Phase, 4 wire, 50 cycles vetor group Dyn-11 having primary (HT) voltage of 11 KV and secondary (LT) voltage of 433 V off load tap changing gear to provide volts with tapping on primary side having steps of + 2.5% from (+) 5% to (-) 7.5% in equal steps of 2.5% each so as to vary voltage on secondary side including first fill of transformer oil, the transformer shall be delta connected on 11KV side & star connected on secondary side with neutral brought out including provn of HT busing on HV (delta connection) side & LT cable box on LV (star connection) side including foundation of size 3.0 x 2.5 x 1.20m of PCC 1:1.5 :3 fencing with GI barbed wire 2 strand 2.24 mm dia around the transformer including angle iron gate with locking arrangement complete all as specified and directed (Note :- GI barbed wire and angle iron, gate will be measured and paid under respective items of Schedule 'A' Section IX)
Supply ,install, testing and commissionig of power factor improvement static condensor (cap bank) of capacity 120 KVAR (1x5+2x10+1x20+3x25) including interconnection with LT panel with appropriate size of electric cable for transformer outdoor type panel factory made ,weather proof ,dust and vermin proof (IP55) suitable for 1100 volts grade 3 phase 50 HzAC supply floor mounted ,fabricated made out of 3.15mm thick MS sheet welded on 40x40x6 mm angle iron frame /base of appropriate size and having four no angle iron legs made out of 40x40x6mm ,60 cm long angle iron below frame with front door and back opening having locking arrengement pre-wire with copper conductor PVC insulated cable /extension strip and connected with suitable size thimbles ,lugs duly embeded in ground in P:C:C: 1:3:6 of suitable size including locking arrengement suitable for mounting with required sheet metal enclosure ,thimbles,all as specified and directed by Engineer-in- charge and all electric incomming and outgoing connection with PVC insulated multi stranded copper wire of suitable size and PVC flexible conduit medium quality as required comprising of the following:- (a) Insulated bus bar of copper of suitable Amps capacity for three phase , and one for neutral of suitable sizewith suitable incommer MCCB and and Capacitor bank or manufacturer strandard design as approved by GE complete all as specified and directed.
LED street light luminaire with unique peanut optics to ensure uniform distribution .higher spacing between poles and maintenance free system lumen output 4500 Lm with colour temp 5700 k LED suitable optical lens as secondary optics covered light source with glass IP-66 inbuilt electronic drivers 230 Volts 45 Watt cap including suitable size of bracket made out of 40 mm GI light grade tubing 1.20 mtr long bent to shape with 02 Nos of clamps, nuts & bolts reqd complete all as specified and directed.
LED post top lantern copper dust painted cast aluminium spigot,spun aluminium canopy with clear acrylic cover light fitting including 25 watt LED lamp or strip and suitable dia of GI pipe for mounting the fitting, prewired complete with all accessories.
Junction Box of size 300x250x150mm with locking arrangement suitable for aluminium bus bar (04 Nos.) fixed on porecelain base insulator & 01 No MCB SP, 06A. Junction box made out of 2 mm thick MS sheet, painted with 2 coats of synthetic enamel paint over a coat of redoxide primer complete with suitable size of cable glands & MS clamps nuts, bolts & washess etc complete all as specified
Cable route indicator shown "HT UG cables" painted in brown colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specified
Cable route indicator shown "LT UG cables" painted in blue colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specified and directed.
Material and labour for boring of holes,under road,pavement,hardstanding by trenchless technology using ultrasound technique or any other method suitable for laying of DI/GI tubing complete all as specified and directed.
SOLAR WATER HEATING SYSTEM WORKS
Supply, installation, testing and commissioning of solar water heater with heat exchanger type, conforming to IS 12933 & 13129 for cold region of 500 litre/ day capacity with electric heating backup of 4 KW and rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 500 Ltr capacity, triple layer as make up water tank including 20mm dia brass float valve, SS Puff insulated hot water collecting tank of suiatable capacity, hoisted and fixed in position on suitable steel staging as directed by GE complete all as specified and as directed. Note:- (i) The system shall be tested on completion to ensure that 500 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season. (ii) All other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in unit rate quoted. (iii) Normal water pipes and accessories from and including cold water make up tank upto & including hot water SS tank, all other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in quoted unit rate.
Supply, installation, testing and commissioning of solar water heater with heat exchanger type, conforming to IS 12933 & 13129 for cold region of 400 litre/ day capacity with electric heating backup of 3 KW and rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 500 Ltr capacity, triple layer as make up water tank including 20mm dia brass float valve, SS Puff insulated hot water collecting tank of suiatable capacity, hoisted and fixed in position on suitable steel staging as directed by GE complete all as specified and as directed. Note:- (i) The system shall be tested on completion to ensure that 400 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season. (ii) All other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in unit rate quoted. (iii) Normal water pipes and accessories from and including cold water make up tank upto & including hot water SS tank, all other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in quoted unit rate.
PLAY GROUNDS
Polycarbonate board of size 1800 x1100 x 25mm thick of make:- Nalco or as approved by GE, fixed in angle iron frame of 25 x 25 x 3mm thick, basket ring of 45cm dia made of 12mm dia plain mild sheet round bar and synthetic net complete and fixed to post with standard nuts and bolts complete all as specified and directed. Note: Mild steel work will be measured and paid for seperately under respective item of Schedule 'A' Section XIV
Note: For the purpose of arriving at lumpsum amount, the amount of credit sch for buildings and other services i.e Sch 'A' section XVII (i.e Rs 25,51,384.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Section-XVIII Rs.
Sood Enterprises
J.D.Builders
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
Ktech Engineer Builders Co. Pvt. Ltd
M/s Jatindra Construction Company
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
VIJAY JINDAL BUILDERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.09 MB
Download all tender documents and submit your bid