| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.5 LAccepted-AOC ERNAKULAM 682025 | ERNAKULAM | ERNAKULAM | KERALA | 682025 | 1 | Accepted-AOC L1 accepted |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
The Office of the Executive Engineer PWD Electrical Division, Thiruvananthapuram - 695033
Construction of Mini Civil Station at Pothencode, Thiruvananthapuram - Lift
2021_PWD_408461_1
EDT_ET_46_2020_21
Open Tender
Electrical Works
Item Rate
122 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,800
₹50,000
22 Jul 2021
23 Jan 2021
5 Feb 2021
23 Jan 2021
1 Feb 2021
23 Jan 2021
23 Jan 2021 - 1 Feb 2021
60 days
Amount
6mm anti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 16. Landing entrance: Automatic centre/ telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and Stainless Steel framed 1/2 glass door. 17. Call and position indicators : Up/down direction & position Dot Matrix / LED indication shall be provided at all landings 18. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 19. Infra red door opening system : To be provide for entire length of the door 20. Automatic Rescue Device : Provide automatic rescue device with an electronic controller powered by 4 Nos. 12V 24 AH dry free maintenance batteries. The rescue operation should act within 10 seconds of power failure 21. Regulation : 350V- 450V (SMPS based) 22. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light
f) Non stop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with push to talk j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 23 Winding handle: Manual winding handle for use in emergency. 24.Safeties: a) Over speed governor, operated safety gear b) Buffers c) Motor over load protection. d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventor g) Final limit switch 25. Levelling : Automatic levelling at all landing as per IS 26.Guarantee : Company shall carry out free maintenance during warranty period of 36 months which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit. 27. Control panel : Control panel will be dust and vermin proof of sheet metal enclosure.
28. Announcement System : To provide lift announcement system 29. Tests : At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 30. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side of the wall by additional brick work or cutting existing brick work, core cutting in floor slabs. c) Scaffolding d) Door frames e) Supporting steel f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with push to talk h) Battery operated alarm
i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. Necessary fee shall remitted to the Inspectorate by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting l) Free servicing for 36 months after handing over
6mm anti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 16. Landing entrance: Automatic centre/ telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and Stainless Steel framed 1/2 glass door. 17. Call and position indicators : Up/down direction & position Dot Matrix / LED indication shall be provided at all landings 18. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 19. Infra red door opening system : To be provide for entire length of the door 20. Automatic Rescue Device : Provide automatic rescue device with an electronic controller powered by 4 Nos. 12V 24 AH dry free maintenance batteries. The rescue operation should act within 10 seconds of power failure 21. Regulation : 350V- 450V (SMPS based) 22. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light
f) Non stop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with push to talk j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 23 Winding handle: Manual winding handle for use in emergency. 24.Safeties: a) Over speed governor, operated safety gear b) Buffers c) Motor over load protection. d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventor g) Final limit switch 25. Levelling : Automatic levelling at all landing as per IS 26.Guarantee : Company shall carry out free maintenance during warranty period of 36 months which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit. 27. Control panel : Control panel will be dust and vermin proof of sheet metal enclosure.
28. Announcement System : To provide lift announcement system 29. Tests : At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 30. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side of the wall by additional brick work or cutting existing brick work, core cutting in floor slabs. c) Scaffolding d) Door frames e) Supporting steel f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account.
g) Intercom facilities with push to talk h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. Necessary fee shall remitted to the Inspectorate by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting l) Free servicing for 36 months after handing over
Bidder Name
INFRA ELEVATORS INDIA PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_580485.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .