Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.7 LAccepted-AOC V P O BOPARAI KALAN DISTT LUDHIANA 141422 PB | LUDHIANA | LUDHIANA | PUNJAB | 141422 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹85.0 L+₹1.2 L (1.49%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹90.8 L+₹7.1 L (8.44%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹97.4 L+₹13.6 L (16.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
24 Nov 2021, 6:00 pmClosed
CWE AF Ambala
HQ CWE AF Ambala Ambala Cantt PIN 133001
SPECIAL REPAIR /RENOVATION OF CERTAIN STAFF QTRS OF KV NO 1 AT AF STN HALWARA UNDER GE (AF) HALWARA
2021_MES_475022_1
CWE/AF AMB/HAL-27/2021-22
Open Tender
Civil Works
Item Rate
270 days
Halwara
For enlisted in MES Class B and category a i and for unenlisted refer NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE AF Halwara
₹1.8 L
Yes
6 Jan 2022
14 Sept 2021
26 Nov 2021
14 Sept 2021
24 Nov 2021
10 Nov 2021
14 Sept 2021 - 9 Oct 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
M&L coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in cement mortar 1:6, complete all as specified and directed.
M&L coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in cement mortar 1:6, complete all as specified and directed.
M&L coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
Material and labour jointfee glazed desinger ceramic coloured tiles of size 300mm X450mm, 6mm to 7mm thick on vertical surface as in skirting/dado, set and jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L 50mm thick PCC 1:3:6, type C-1, using 20mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length. (ii) 30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
Material and labour machine cut Granite stone slab/tiles, 18mm to 20 mm thick, table rubbed and polished, as on shelves/ cooking platform/steps/pillars etc, like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20 mm thick screed bed or bedding layers in cement mortar 1:4, set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in sunken floors above ground level & pavings exceeding 15 cm thickness and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Material and labour PCC 1:5:10, type E-2, using 40 mm graded mechanically crushed stone aggregates as in foundation, sub base (as in sunken floor) and mass concrete complete all as specified and directed.
Material and labour for applying two coat of water proofing compound as per manufacturer's instruction by brush on the entire surface of sunken portion, 15mm thick screed bed/bedding layer in cement mortar 1:3 mixed with integral water proofing compound @ 130ml per bag of cement including one bonding coat of cement slurry mixed with WPC @ 200ml per bag of cement complete all as specified & directed.
Material and labour PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed. Note : The quoted rates include for use of formwork (straight or curved).
S&F 32mm bore medium grade GI pipe 450mm long bevelled cut at both ends by making hole in walls sunken portion approx above the RCC slab and ceiling finished the hole with cement plaster 1:2 to match with existing surface complete all as specified and directed.
Cutting holes in brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4, type B-1 as required, area not exceeding 150 sqcm complete all as specified and directed.
Taking up/down steel tubing and connections for refixing or removal from site for 15 mm bore pipe complete all as specified and directed.
Taking up/down steel tubing and connections for refixing or removal from site for 20 mm bore pipe complete all as specified and directed.
S&F GI tubes 15 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
S&F GI tubes 20 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
S&F in repair 20 mm bore ball brass valves, high pressure, with polythene float and fly nut, screwed complete all as specified and directed.
S&F in repair 20 mm bore stop valves, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
S&F in replacement rotational moulded polythene(PVC) water storage tank, HDPE, off white colour, triple layered , cylinderical type fixed and hoisted in position on roof, at any height, of capacity 750 ltr and making connections with 20 mm GI pipe inlets & outlets complete including locking arrangements and 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gram) complete all as specified and directed.
S&F in replacement EWC jet (health faucet) , chromium plated, fancy type, 15 mm bore with 1 mtr long PVC connection pipe complete all as specified and directed.
S&F in repair cast iron floor trap 75mm dia with chromium plated grating, including jointing to waste pipe with run lead joint and embedded in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F in replacement vitreous china wash hand basin, flat back or angle back type, white, size 550x400mm including 32mm bore PVC waste pipe and CP waste fitting and a pair of mild steel angle iron brackets of suitable size fixed as in counter slab complete all as specified and directed.
S&F in replacement vitreous china wash down water closet (Pedestal pattern), white, including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom, aluminium hinging devices including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed.
S&F in replacement PVC low level flushing cistern, white, valveless syphonic action type 10 litre capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified and directed.
S&F in repair PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
S&F in replacement PVC bath cabinet mirror, white, size 350mm x 450mm with 4 mm thick framed mirror complete all as specified and directed.
S&F in replacement chromium plated grating doom 100mm dia fixed complete all as specified and directed.
S&F in replacement brass, chromium plated, shower rose 125mm size,15 mm dia, with or without swivel joints including fixed to steel pipe or union, complete all as specified and directed.
S&F in replacement brass chromium plated 15mm bore, hot and cold wall/basin mixture screwed down for water pipe complete as specified and directed.
S&F in repair bib taps, 15 mm bore, cast copper alloy, brass chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed.
Supply and fixing in repair 15 mm bore stop valves/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15 mm bore pillar tap, cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair 15 mm bore stop valves, concealed type, cast copper alloy, fancy type, chromium plated with long shank and cup, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe including cutting chases required for concealing complete all as specified and directed.
S&F in repair chromium plated, brass, tubular towel rail, fancy type, with fancy type brass CP brackets on both sides, 20mm dia, D type 600mm long between flanges , fixed with screws complete all as specified and directed.
S&F in replacement sink with drainage board made of stainless steel 1.00 mm thick steel sheet, kitchen or laboratory with plug & chain, waste coupling, washers and 32 mm bore PVC waste pipe including bedding in cement mortar to dwarf wall or including fixing cantiliver MS brackets and connecting union to pipe, over all size 915 mm x 460mm & bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Supply and fixing sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
Supply and fixing figured glass, pin head type, 4.0 mm thick and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.50sqm but not exceeding 4.0sqm each with shutters (without taking off shutter from frames) removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and directed
Taking down chowkhats or frames not exceeding 1.5 sqm each with shutters (without taking off shutter from frames) removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and directed
Taking down shutters exceeding 1.0 sqm but not exceeding 2.0 sqm each, any description, complete all as specified and directed
Resecuring or easing & adjustment of shutter of any description without taking down shutter, shutter exceeding 1.0 sqm but not exceeding 2.0 sqm each complete all as specified and directed
Supply and fixing pressed steel door frames of size 125 mm x 60 mm with one or more rebates including fixing necessary lugs, 3 Nos 100 mm long hinges per shutter , lock strike plate etc. including making good the disturbed portion to match with existing complete all as specified and directed.
Supply and fixing pressed steel door frames of size 105 mm x 60 mm with one or more rebates including fixing necessary lugs, 3 Nos 100 mm long hinges per shutter, lock strike plate etc. including making good the disturbed portion to match with existing complete all as specified and directed.
Material and labour plain cement concrete, 1:3:6, type C-0, using 12.5 mm graded mechanically crushed stone aggregate as in hold fasts, filling of pressed steel frame etc. complete all as specified and directed.
Supply and fixing 30mm thick flush shutter, factory made, solid core construction with particle board core and plywood face panels commercial type on both side complete all as specified and directed.
S&F factory made, solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelaminted sheet reinforced with mild steel square tube, edges will be painted to match with prelaminated sheet, suppling & fixing in opening as per specification & drawing as per SSR Part –II complete all as specified and directed.
Supply and fixing factory made, solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails. Mild steel frame shall be covered with heat moulded both side prelaminated PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelaminted PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side prelaminated PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing as per SSR Part –II complete all as sepcified and directed.
Supply and fixing factory made, second class, hard wood(hollock), plain framed, panelled shutter (two panel), 35 mm thick with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Supply and fixing second class, hard wood(hollock), glazed and skeleton shutter, 35mm thick, factory made, open rebated and prepared to receive glass/guage etc, without sash bars, mitred and rebated, with edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/guage etc, sizes of stiles, rails etc as specified in Section 8, clause 8.24(a) of SSR part-I(2009) complete all as specified and directed.
S&F decorative laminates 0.9 mm thick, type 1 of any tint/design/pattern as approved & fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S&F in repair 18/19 mm thick block board, grade 1 quality, exterior grade, commercial type, fixed with screws to timber frame work complete all as specified and directed.
S&F factory made Box type steel window, double shutter, glazed and wire gauzed with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets, including provision and welding of grills complete all as specified and directed. Notes: - (i) Windows shall be fabricated as per drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 and these drgs may be referred from GE office or from the office of CWE (AF) Ambala. (ii) Glazing, Wire cloth & MS grills shall be measured and paid separately . (iii) Painting to window shall be measured and paid separately. (iv) Double shutter meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. Both the shutters shall be measured as one unit. (v)Steel window shall comply with IS 1038-1983 &. Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F steel ventilator fixed type with glazing bar complete all as specified & directed Note:- Glazing & painting shall be measured and paid separately .Steel ventilators shall comply with IS 1038-1983 & Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed
Supply and fixing Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
S&F 100 mm size, MS butt hinges, medium weight, cold rolled, fixed complete all as specified and directed
S&F 200 mm long, aluminium, anodized, barrel tower bolt of extruded section complete all as specified & directed
S&F 150 mm size, aluminium alloy, handle, cast type, anodized fixed complete all as specified and directed
Supply & fixing MS Helical door spring 300 mm ordinary rat tail rod pattern including roller and roller plate complete all as specified and directed
M&L preparation of new wood and wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over & including one coat of pink primer complete all as specified and directed.
M&L preparation of new steel and iron based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified and directed.
S&F 150 mm length of cover plate, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with vulcanised rubber piece complete all as specified and directed.
Taking down curtain rod/curtain rail alongwith wooden pelmets fixed on wall complete all as specified & directed
S&F mild steel curtain rod made out of 25mm dia (inner dia) pipe having thickness 0.63mm, PVC coated and colour/pattern, overall dia 28mm to 29mm complete all as specified & directed
S&F plastic finial of 28mm to 29mm bore, decorated type, any colour /pattern, best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified & directed
S&F mild steel prepainted brackets to hold the curtain rod and fixed to wall (concrete/brick) with the help of 2 Nos. 50mm long steel screws and rawl plug complete all as specified & directed
Demolition of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles complete all as specified and directed.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exceeding 6 mtr mean radius, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance not exceeding 500 mtr complete all as specified and directed.
Material and labour rendering 15 mm thick in cement mortar 1:6, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces as in wall complete all as specified and directed.
Material and labour rendering 5 mm thick in cement mortar 1:3, finished even and smooth without using extra cement on fair faces of concrete surfaces as in ceiling complete all as specified and directed.
Material and labour rendering 15 mm thick in cement mortar 1:4, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces as in wall complete all as specified and directed.
Material and labour preparation of newly plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
Material and labour preparation of newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
Material and labour preparation of newly plastered surfaces of wall and applying two coat of cement base paint over & including one coat of alkali resistant primer complete all as specified and directed.
Material and labour preparation of newly plastered surfaces of wall, applying one coat of wall care putty(3mm thick) to make the surface even & smooth and applying two coats of distemper oil emulsion of approved shade/tint, complete all as specified and directed.
Complete removal of existing treatment and applying two coats of distemper oil emulsion of approved shade/tint over & including one coat white wall care putty(3mm thick) as specified to achieve smooth finish surfaces of walls complete all as specified and directed.
Complete removal of existing treatment and applying two coats of cement base paint over & including one coat white wall care putty (3mm thick) as specified to achieve smooth finish surfaces of walls complete all as specified and directed.
Material and labour preparation of old treated plastered/unplastered surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling holes & cracks with cement base putty and applying two coat of white wash on ceiling complete all as specified and directed.
M&L preparation of old painted wood and wood based surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed stoneware, AC or PVC), internal dia 150mm, set in cement mortar complete all as specified and directed.
Supply and fixing PVC (SWR) pipe 110 mm bore, single socketed in any length with rubber ring joints, fixed to wall/floor complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius provided without access door complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and any position not otherwise specifically provided including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Material and labour Precast cement concrete, 1:2:4, type B-1 using 20 mm graded mechanically crushed stone aggregates set in cement mortar 1:4 as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed. Note : The quoted rates include for use of formwork (straight or curved).
M&L mild steel TMT bars, 10 mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layers on roof and rubbish off the premises including stacking of servicable brick tiles complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including rubish off the premises to a distance not exceeding 500 mtr complete all as specified and directed
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and directed
Material and labour 50 mm average thickness, PCC 1:2:4, type B1, using 20 mm graded mechanically crushed stone aggregates over roof slab as in padding in slope to make good the depressions/undulations complete all as specified and directed.
Material and labour 10 mm thick plastering in cement mortar 1:4 on cleaned RCC roof slab surfaces, sides of parapet etc mixed with water proofing compound (WPC) as per manufacturer's instructions, finished even and fair complete all as specified and directed. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound (WPC) complete all as specified and directed.
Material and labour Atactic Polypropylene (APP) polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.0 kg per sqm, black finish reinforced with non-woven polyster (Weight not less than 150 gms per Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per Sqm below APP including applying two coat of Aluminium paint over top of APP surface complete all as specified and directed . Notes:- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. 5% amount of the total amount of water proofing treatment (BOQ item No 91.00 to 97.00) shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
Material and labour post constructional anti termite treatment of the soil along external perimetre of building below ground level or masonry apron at the rate of 2.25 litre of emulsion per metre of surface area including drilling and plugging holes etc. in apron complete all as specified and directed.
Material and labour post constructional anti termite treatment of the soil under existing floor using emulsion at the rate of one litre of emulsion per hole, 300 mm apart including drilling and plugging 12 mm dia hole with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor complete all as specified and directed.
Material and labour post constructional anti termite treating at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed. Note for item No. 98.00 to 100.00:- For Guarantee & Security deposit refer Particulars specification.
Surface excavation not exceeding 30cm deep & averaging 15cm deep and getting out in soft/losse soil complete all as specified and directed.
Material and labour 100mm thick PCC 1:4:8, type D2, using 40mm graded mechanically crushed stone aggregate as in sub bases of floor complete all as specified and directed.
Material and labour 60mm thick, M-35 grade, machine pressed precast concrete with grey cement & pigment interlocking paver block any shape and size(as approved by GE) confirming to IS 15658-2006 complete all as specified and directed.
M&L sand filling under floors/pavements or in foundations including watering and consolidation complete all as specified and directed. Note: Consolidated thickness shall be measured.
Material and labour Precast cement concrete, 1:2:4, type B-1 (using 20 mm graded mechanically crushed stone aggregates) block masonry with solid blocks exceeding 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed. Note : The quoted rates include for use of formwork (straight or curved).
M&L PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. Note : The quoted rates include for use of formwork (straight or curved).
S&F in repair vitreous china squatting pan (Orissa pattern) 580mmx440mm, white with PVC ‘P’ or ‘S’ trap front or back inlet with integral foot rests excluding flushing cistern and flush pipe including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed.
Material and labour machine cut Kota stone slab 18 to 20mm thick as in flooring/stair case landing, laid over and including 15 mm thick screed bed in cement mortar 1:6, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Material and labour machine cut Kota stone slab 16 to 20 mm thick as in skirting / dado, steps, laid over and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
S&F in replacement stainless steel plate rack of size approx 750mm x 900mm x 250mm, made out of 1.0 mm thick steel sheet with fixing arrangement and as per sample kept in GE's office suitable for officers quarters complete all as specified and as directed.
Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from floors or walls complete all as specified and directed.
S&F bend (any radius) with ducks foot or heel rest of 100mm bore complete all as specified and directed.
S&F 100mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
M&L 100mm dia outlet, cast iron floor trap with grating, including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Dismantling of 75mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from floors or walls complete all as specified and directed.
S&F 75mm bore spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius provided without access door complete all as specified and directed.
S&F 75mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 75mm bore branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 100 mm cast iron sanitary connection socket to fit WC outlet complete all as specified and directed.
S&F 100mm cast iron sanitary connections, short connections pipe of length upto 300 mm complete all as specified and directed.
M&L 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
M&L 32mm bore dia of discharge pipe, waste coupling of PTMT (half or full threaded) (Minimum weight 45 gram) complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls/floors/ceilings complete all as specified and directed .
Material and labour for concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one light point, ceiling fan/exhaust fan point & call bell point controlled by one way switch 5/6 amp complete all as specified and directed.
Material and labour for concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one light point, ceiling fan/exhaust fan point & call bell point controlled by two way switch 5/6 amp complete all as specified and directed.
Material and labour for concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 5/6 amp controlled by one switch on the same board complete all as specified and directed.
Material and labour for concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 5/6 amp controlled by one switch on the independent board complete all as specified and directed.
Material and labour for concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 2.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one switch on the independent board complete all as specified and directed. Note for srl No 126.00 to 130.00 :- (i) Switch, socket outlet, switch socket combination, bell push and fan regulator shall be measured and paid for separately. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match with the existing surfaces.
Taking down carefully aluminium submain wiring of any type and size from surface /concealed with taking down conduit and fittings complete all as specified and directed.
M&L concealed sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through in and including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified and directed. Note :- Two runs of 4 sqmm cable alongwith one run of 2.5 sqmm cable as earth wire alongwith conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
M&L concealed sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through in and including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified and directed. Note :- Two runs of 6 sqmm cable alongwith one run of 4 sqmm cable as earth wire alongwith conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
S&F switch piano, flush type, 5/6 amp, single pole, one way, 240 volt complete all as specified and directed.
S&F switch piano, flush type, 5/6 amp, single pole, two way, 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 5 pin, 5/6 amp, 240 volt, complete all as specified and directed.
S&F switch piano, flush type, 15/16 amp, single pole, one way, 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 5 pin, 15/16 amp, 240 volt, complete all as specified and directed.
S&F bell push, flush type, 5/6 amp, 240 volt complete all as specified and directed.
Supply and fixing call bell, ding dong type, 230 Volts, single phase complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosures powder coated deep drawn DB with clad socket & plug top duly installed neutral link adjustable din rail and connecting link with and including one single pole MCB 20 Amp, 'B' curve 240 volts, 10 kA complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite, 65X50 mm two/three terminals ,230 volts,ISI mark complete all as specified and directed.
S&F stepped type electronic fan regulator flush type, single pole 240 volts, 50 Hz, 100 watts, 4 step type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
Supply & fixing lamp holder PVC/Polycarbonate insulated body with back plate suitable for angle/batten fitting complete all as specified and directed.
Supply and fixing retrofit LED bulb 9 watts, pin type, colour white light complete all as specified and directed.
Supply and fixing in replacement LED tube light fitting 1x20 watt four feet length including LED electronic driver, 230 volts in commmercial channel with powder coated CRCA sheet housing with opal acrylic diffuser for LED with & including LED tubelight with high efficient LED 20 watts in aluminium housing with clear & milky diffuser including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed.
Supply and fixing Bulk head LED light fitting 10 watts including LED electronic driver fixed to wall/ceiling with FI clamps, nuts, bolts, washers etc with and including LED lamp 10 watts and connecting with twin core twisted flexible copper conductor cable of suitable size not more than One mtr and making necessary connection to make it functional complete all as specified and directed.
Supply and fixing in replacement LED tube light fitting 1x10 watt two feet length including LED electronic driver, 230 volts in commmercial channel with powder coated CRCA sheet housing with opal acrylic diffuser for LED with & including LED tubelight with high efficient LED 20 watts in aluminium housing with clear & milky diffuser including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed.
Supply & fixing heavy duty exhaust fan, single phase, 230/240 volt, 300mm sweep, steel body, turbo force, 1400 RPM, totally enclosed heavy duty motor with copper winding including mounting brackets for on wall, grouting of nuts and bolt etc required for fixing fan alongwith MS sheet 1mm thick louver shutter of suitable size, making connetions with twisted copper flexible wire 23/0.0076mm complete all as specified and directed.
Supply and fixing LED street/ building security light fitting 35 watt new generation energy saving & environment friendly long life versatile pressure die cast aluminium housing with heat resistance toughned glass,IP 66 protection, electronic driver , fixed with wall/surface by providing suitable size of nuts, bolts,washers etc, making necessary connections with suitable size copper wire from junction box to make it functional complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs, 415 volt, triple pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs ,230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link,12 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs ,230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 8 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs, 230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement MCB, TPN, 63 Amp, B curve, 10 kA capacity, 415 volts complete all as specified and directed.
Supply and fixing in replacement MCB, SPN, 40 Amp, B curve, 10 kA capacity, 240 volts complete all as specified and directed.
Supply and fixing in replacement MCB, SP, 5 to 32 Amp, B curve, 10 kA capacity, 240 volts complete all as specified and directed.
S&F ceiling fan, copper winded complete with accessories, 1200 sweep, minimum 5 star rated and including hanging, connecting with existing point including taking down and deposit to MES yard of existing unserviceable ceiling fan complete all as specified & directed.
BLANK
S&F flexible hot water connection made of stainless steel thread braided on heavy duty PVC connection pipe, size 15 mm bore, 450mm long, for hot water connection for storage type water heater complete all as specified and directed.
Material and labour earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth wire 4.0 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 15 mm bore, light grade including protection pipe GI light grade 20mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion on site complete all as specified and as directed. Notes:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 95 sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 35 sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 25 sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 16 sqmm 2 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed. Note for Srl item No 162.00 to 165.00:- Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 Sqm on plan or for laying pipes/cables etc and getting out, in soft/losse soil complete all as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) as specified in clause 19.75 of SSR Part-I complete all as specified and directed. Note: Sand shall be fine sand as specified in clause 14.5 of SSR Part-I
Supply and laying old size, sub class 'B' bricks, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L GI pipe 40 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed .
Supplying, installation, testing & commissioning in replacement floor mounted, cubical type, LT feeder pillar enclosure, outdoor, canopy type, factory made, CPRI approved, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust, weather & vermin proof, powder coated including 200 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system including bus bar chamber, danger notice plate, wiring with suitable size of copper cable, suitable power factor capacitors, mounted on PCC 1:3:6 type C-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level & 60cm below ground level with angle iron frame complete with the following accessories all as specified and directed:- (a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 200 Amp fixed on PVC heat shrinkable insulator heavy duty. (b) Incoming MCCB 160Amp, 415 Volts, 25 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting - 01 No. (c) Outgoing MCCB-100 amps,415 Volts, 16 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting - 02 Nos. (d) Digital Voltmeter, Ammeter, Slector switches, ON & OFF push button, Indication lamp RYB-01 Set Note :-The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item. The layout diagram of LT feeder pillar shall be approved by Accepting officer.
Supplying, installation, testing & commissioning in replacement floor mounted, cubical type, LT panel, intdoor type, factory made, CPRI approved, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust and vermin proof, powder coated including 315 Amp rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system including bus bar chamber, danger notice plate, wiring with suitable size of copper cable, suitable power factor capacitors, mounted on PCC 1:3:6 type C-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level & 60cm below ground level with angle iron frame and PCC platform complete with the following accessories complete all as specified and directed:- (a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 315 Amp fixed on PVC heat shrinkable insulator heavy duty. (b) Incoming MCCB 200 Amp, 415 Volts, 50 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting - 01 No. (c) Outgoing MCCB-100 Amps, 415 Volts, 25 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting - 03 No.. (d) Outgoing MCCB-63 Amps, 415 Volts, 10 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting - 01 Nos. (e) Auto timer switch, 1 phase, 8 kilowatt, Nature switch-02 + contactor -40 Amp per pole (two pole bridged) + MCB 63 Amp in build feeder pillar enclosure -01 Set (f) Digital Voltmeter, Ammeter, Slector switches, ON & OFF push button, Indication lamp RYB-01 Set Note :- The cost of the PCC block & PCC platform of size 1000mm x 750 mm x 150 mm shall be deemed to be included in the unit rate quoted for the item. (ii) The layout diagram of LT panel shall be approved by Accepting officer. (iii) The LT panel shall be confirming to IS-8623.
Material and labour in replacement earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth lead strip 32x6 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI light grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion on site complete all as specified and as directed. Notes :- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the earth resistance is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Supply and fixing in replacement 1100 volts grade heavy duty cable insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed as in service connection suspended by insulated hangers not more than 1 mtr apart including 4 mm suspension wire one twin core 6 sqmm stranded conductor complete all as specified and directed
Supply and fixing Junction box on existing pole of minimum size 300mm x 200mm x 150mm made out of 1.6mm thick MS sheet duly painted with two coat of synthetic enamel paint over & including one coat of red oxide primer, outdoor type, lockable complete with fixing arrangement with 100 amps capacity aluminium bus bar 4 Nos. and one No. 10 Amp MCB SPN including clamp made out of flat iron 25mm x 3mm and nuts, bolts washer and thimbles etc complete all as specified and directed
M&L GI pipe 15 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed .
“ Supply and fixing LED light fittings 120watts, input 110 volts to 240 volts volts, life > 50000 Hrs, operating temp 1 degree to 50 degree, as per IP 66 , luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of min 5000 lumens with 120 degree view angle , the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 with and including GI bracket 40 mm dia light grade of length 1.2 meter bend to shape and suitable size of clamps nuts bolts , washer , fashner duly painted with corrosion resistant paint complete all as specified and directed
M&L true vertical steel tubular, swaged welded pole conforming to IS-2713 part II , type 410 SP 37, 9.5 metre long complete with mild steel base plate of 6 mm thick of size 300 X 300 mm, finial taper plug, cap, bolts, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & nubmering of pole including following complete all as specified and directed. (i) Excavation 600mm x 600mm & upto 2 mtr deep below GL and returning filling & removal of soil in soft / losse soil. (ii) PCC 1:4:8, D-2 as foundation filling upto 1.8 mtr deep below GL. (iii) PCC 1:3:6, C-2 as in coping & plinth upto 300mm high above GL.
Taking up/down steel tubing and connections for refixing or removal from site for 25 mm bore pipe complete all as specified and directed.
Taking up/down steel tubing and connections for refixing or removal from site for 40 mm bore pipe complete all as specified and directed.
S&F galvanized iron water tubes 20 mm bore, medium grade, with all fittings laid in trenches complete all as specified and directed.
S&F galvanized iron water tubes 25 mm bore, medium grade, with all fittings laid in trenches complete all as specified and directed.
S&F galvanized iron water tubes 40 mm bore, medium grade, with all fittings laid in trenches complete all as specified and directed. Note for item No. 182.00 to 184.00 : Excavation for taking down of pipe & laying new pipe shall be paid once and shall be measured & paid separately.
S&F GI tubes 25 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
S&F in replacement 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in replacement 25 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in replacement 40 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 15 mm bore ball brass valves, high pressure, with polythene float and fly nut, screwed complete all as specified and directed.
S&F in repair bib taps, 15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal 15mm dia complete all as specified & directed. Note: The rates include for turning water off and on and draining and refilling the system as required.
M&L boring of road crossing of size 80mm dia at suitable depth not less than 1mtr by using machinery / equipments complete without damaging the surface for passing pipes including removing excavated soil to a distance not exceeding 50mtr complete all as specified & directed. Note:- Location of boring holes shall be decided by the Engineer-in-charge as per requirement , nothing extra shall be payable on account of variation in length of crossing of road etc. During boring, soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes thorugh different strata/soil.
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.
M/S SANGA SINGH AND CO
S M BUILDERS
BEHL AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .