| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.7 L+₹1.2 L (2.58%)Rejected-AOC NIL | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹47.0 L+₹1.4 L (3.15%)Rejected-AOC | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹48.3 L+₹2.8 L (6.13%)Rejected-AOC | L4 | Rejected-AOC Become L4 | |
| 5 | L5₹48.9 L+₹3.4 L (7.46%)Rejected-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L5 | Rejected-AOC Become L5 |
Tender Value
Refer Docs
EMD Value
₹99,920
Closing Date
19 Apr 2021, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur
PROVN OF HARD STANDING AT VARIOUS LOC OF LT REGT SPL REPAIRS TO BLDG NO T-58 (MT OFFR) AT 4 COSR NOW 4 CSR SPL REPAIRS TO INTERNAL WIRING AND ITS ACCESSORIES IN BLDG NO P-15 and 16 AT ZONE 4A AND SPL REPAIRS TO E and M INSTALLATION UNDER GE (S) TEZ
2021_MES_431843_1
8556
Open Tender
Civil Works
Item Rate
240 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹99,920
Yes
19 May 2021
19 Mar 2021
21 Apr 2021
19 Mar 2021
19 Apr 2021
5 Apr 2021
Amount
Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering complete all as specified and as directed by Engineer-in-charge.
Dismanting timber scantling 40 Sqcm and over in secion in any position in framed work or unframed work complete all as specified and as directed by Engineer-in-charge.
Ditto all as per Ser Itme no 2 above but In fillests, rails , posts, refters and purlins etc under 40 sqcm in section unframed work
Dismantling floor hearth wall tiling incl cement mortar bededing(but not backing),
Dismantling Structural steel work includings door, gates, etc and similar works complete all as specified and as directed by Engineer-in-charge.
Taking down chowkats or frames exc 1.5sqm and not exc 4.0 sqm each with shutters ( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts complete all as specified and as directed by Engineer-in-charge.
Taking down chowkats or frames not exc 1.5sqm each with shutters( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed by Engineer-in-charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and as directed by Engineer-in-charge.
S&F 0.5mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour ,tensile strength of 550Mpa as in roof covering ,cladding to wall ,ridge,gutter etc fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
All as per item No.10 above but plain sheet for ridge ,gutter etc fixed with self tapping screws as specified.
M&L 2nd class HardWood in scantling fixed clean swan in framed work complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in cement mortar including pillar etc below/ above ground level etc and removing to a distance not exc 50 meter. complete all as specified and as directed by Engr-in-Charge.
Material and labour for old size fly ash /concrete best quality bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:6) having compressive strenght not less than 75 kg/Sq cm all as specified and directed.
M/L PCC 1:3:6 type C1 20mm grade aggregate as in padding, hold fasts block filling, filling of steel chowkhats, coping or similar work complete all as specified and as directed by Engineer-in-charge.
Supply and fix, pressed steel frames of size 125 mm x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike, plate etc complete all as specified and directed
S&F factory made solid PVC door frame of size 50mm x 47 mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube complete all as specified and as directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC stiles and plain colour PVC sheets for top rail, lock rail bottom rail on either side & as gap insert for top rail & bottom rail panneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheet beading & jointed together with solvent cement all as specified and shown on drawing.
M&L 2nd Class Hard wood plain fillets square, rectangular or triangular in section clean sawn sectional area exe 6 sqcm & n exe 13 sqcm fixed with nails complete all as specified and as directed by Engineer-in-charge.
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.
S&F MS framed works such as grills grating etc with ends of bars shouldered and for rivetted in forged into spikes, framed guard bars, railing and similar work confiring to Fe-410-0 or Fe 310-0 complete all as specified and directed
S&F Anodised aluminium frame two three track for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-charge.
S&F Anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading,locking block screws etc.complete all as specified and as directed by Engineer-in-charge.
S&F 30 mm thick 2nd class hard wood factory made flush shutter solid core construction with block board core and plywood face panels commercial type of both side complete all as specified and as directed by Engineer-in-charge.
S&F 35 mm thick 2nd class hard wood Glazed and skelton shutter open rebated and prepared to receive glass, gauze etc (without sash bars) edges of the framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members as specified in SSR Pt I clasue 8.24 (a)
S&F 2nd class hard wood small fitting such as brackets of any type latch and hinge blocks,shaped door and window stops and the like including all necessary labours articles exe. 200cu.cm and n.exe 200 cu.cm each complete all as specified and as directed by Engineer-in-charge.
S&F Butt hinges medium weight cold rolled mild street and fixed size of hinges 50mm complete all as specified and as directed by Engineer-in-charge.
S&F 150mm long aluminium handle, cast type, anodised complete all as specified and as directed by Engineer-in-charge.
S&F Aluminium anodised barrel tower bolts of extruded section 200 mm long and fixed with screws complete all as specified and as directed by Engineer-in-charge.
S&F 100mm Butt hinges medium weight cold rolled mild steel complete all as specified and as directed by Engineer-in-charge.
S&F aluminium sliding door bolts of size 300 mm long with haps and staple (bolt type) and fixing clips of sheet cast or extuded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and as directed by Engineer-in-charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm thk cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and as directed by Engineer-in-charge.
M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado over 10mm thk cement rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
S& F 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 sq. m in each pane in squares complete all as specified and as directed by Engineer-in-charge.
S&F Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-charge.
M & L, 15mm thick rendering in C.M. (1:4) on fair faces of brick work finished even and fair without using extra cement complete all as specified and as directed by Engineer-in-charge.
M & L, 10mm thick rendering in C.M. (1:6) on brick work finished even and fair without using extra cement complete all as specified and as directed by Engineer-in-charge.
Supply and fix, as in repair,20mm dia curtain rails, mild steel, cromium plated, with fixing brackets, stops, rollers etc all as specified and directed.
M&L Applying two coats of Oil bound distember to newly plastered/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer including preparation of newly platsered wall all as specefied and directed.
M&L Applying two coats of Oil bound distember to wall over a coat of 1 mm layer wall care putty over a coat of primer including complete removal of existing treatment all as specefied and directed..
M&L 75mm thick plain cement concrete (1:3:6) type C1 using 20mm graded stone aggregate as in plinth protection and finishing surfaces of concrete even and smooth including making construction joint at interval of 1.2 mtr & filled with bituminous filler complete all as specified and as directed.
Material and labour for providing 25 mm thick cement concrete (1:2:4) type B1 using 20mm graded aggregate as in floors finished the surfaces even and rough to receive to topping layerscomplete all as specified and as directed by Engineer-in-charge.
Supply only 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white, with inlet, ball valve float and handle flush pipe of 32 mm dia including brackets complete all as specified and directed.
Supply and fix, as in repair,15 mm dia 600 mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
Supply and fix, as in repair, vitreous china wash basin, white, flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand including CP Waste coupling and waste pipe 32 mm. complete all as specified and directed.
Supply only 15 mm bore pillar tap, fancy type cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix,as in repair, 15 mm bore bib taps, cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix,as in repairs, 75 mm dia of outlet PVC(SWR) floor trap, plain with granting including jointing with solvent cement all as specified and directed
Supply and fix, as in repair,15 mm stop valve cast copper alloy fancy type chromium plated fixed for 15 mm bore etc complete all as specified and directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in Skirting/Dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
S&F Coloured Glazed ceramic tiles 450 x 300 mm x 6 to 7mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm rendering in Cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
All as per item No 54 here in before but 20 mm bore.
S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed,
All as per item No 56 here in before but 20 mm bore.
M&L preparation of old painted steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
M&L preparation of old painted wooden surfaces over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
M&L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix, as in repairs, (Health Faucet) Brass chromium plated with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified and as directed.
Supply and fix, in repairs bowel urinal flat back of size 465 x 355 x 265mm (minimum), white, with grating and union for discharge pipe, (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals against wall in cement mortar (1:2) securing urinals to plugs with and including 60 mm brass screws and pointing around urinals back in cement complete all as specified and as directed by Engineer-in-charge.
Supply and fix, as in repairs, sheet glass self/corner chelf assembly consisting of 5.00mm thick sheet glass shelf 12cm wide with cromium plated bracket guard all as specified and directed.
Supply and fix, as in repair, vitreous china wash down water closet pan (Pedestal pattern) white (excluding flushing cistern and flush pipe) including seat cover white closed type complete all as specified and directed
M&L preparation of newely plaseter sufaces and appplying two coats of weather coat(Apex) over two primer coats of damp shealth to new plastered walls as per manufacturer and apllied by approved applicator complete all as specified and directed.
Dismantling and breaking up PVC drain pipes of 110mm dia or below jointed in CM and taking out of trenches complete all as specified and as directed by Engineer-in-charge.
Supply and fix, 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls all as specified and directed.
S&F for PVC (SWR) with access door bends 110mm dia complete all as specified and as directed by Engineer-in-charge.
Supply and fix, PVC cowls 110 mm bore all as specified and directed.
M&L for chequered cement concrete tiles of size 300 x 300 x 22 to 25 mm thick with grey cement and pigment, set and jointed and pointed in neat cement slurry in floors laid over & including 15 mm thick screed bed in cement mortar 1:6 all as specified and as directed.
Dismanting wall /ceiling board (Fibre pulp insulation) or insulation boards any thickness including cover filters
S&F false ceiling with powder coated exposed G.I. grid suspension system Everest E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner (3600 mm long, 0.25 mm thick, 38mm height) Cross Tee (1200mm/600mm long, 0.25 mm thick, 27 mm height) and Wall Angle (3000 mm long, 0.4 mm thick, 22 mm height). The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 4 mm thick High Pressure Steam Cured Everest Non Asbestos Fibre Cement Designer Ceiling Board or equivalent quality having Density>1200 Kg/m3, size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7&8, should be placed in the Grid module to form a False Ceiling complete all as specified and directed
M&L preparation of new wooden surfaces n.exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer.
Excavating over areas, n. Exc. 1.5m deep and geting out for soft/lose soil.
Removing excavated material n exc.50 m and depositing where directed at a level n exc 1.5 m above the starting point.
M & L for Hardcore of guage n exe. 63 mm deposited spread and levelled in layers n exe 15 CM thick watered and rammed to a true surface complete all as specified and as directed by Engineer-in-charge.
M&L for 150 mm thick PCC 1:3:6 type C2 using (40 mm graded aggregate) as in paving even and rough to receive topping layers complete all as specifed and as directed.
M & L for Moorum/red bajri in floors or pavings ,laid in layers n.exc 15 cm thick spread ,levelled and rammd including watering complete all as specified and directed
M&L cement concrete 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type C2 using (40 mm graded aggregate) as in floors and pavings including finishing surfaces of concrete topping even and fair (without using extra cement) complete all as specifed and as directed.
M & L forming 12 mm thick expansion joints filled with pre fromed bituminous filler and top 30 mm primed and sealed with compound Grade 'A' all as specifed and directed.
M & L forming contraction(dummy) joints 65 mm deep x 10 mm wide filled with sealing compound Grade 'A' all as specifed and directed.
M&L three coat of white wash incl preperation of new wall surface complete.
M&L for overhauling/ servicing of ceiling fan of any make any model complete after dismantling it and cleaning all parts of fan internally and externally and applying greasing, oiling of bushes and bearings including replacement of bush, bearing, split pin, rubber reel, nuts and bolts, mild steel ‘U’ clamp, fan condenser, Painting of canopy (both Upper & Lower) with one coat of synthetic enamel paint (White colour for ceiling fan) with and including and replacement of copper flexible cord twin core of suitable length not exceeding 0.5 meter length from ceiling rose to ceiling fan including assembling all repair parts of fan and testing it for smooth functioning with and including taking down of ceiling fan and refixing the same in new/ same position complete all as specified and as directed.
M&L for overhauling/ servicing of Exhaust fan of any make any model complete after dismantling it and cleaning all parts of fan internally and externally and applying greasing, oiling of bushes and bearings including replacement of bush, bearing, split pin, rubber reel, nuts and bolts, mild steel ‘U’ clamp, fan condenser, Painting with one coat of synthetic enamel paint (Grey colour for Exhaust fan) with and including and replacement of copper flexible cord twin core of suitable length not exceeding 0.5 meter length from ceiling rose to ceiling fan including assembling all repair parts of fan and testing it for smooth functioning with and including taking down of ceiling fan and refixing the same in new/ same position complete all as specified and as directed.
Supply and Fix louver shutter (with Mosquito net made out Aluminium wire cloth 0.36 mm nominal dia ) made out GI sheet (Thickness of louver shutter Body 1mm ,shutter Fins 0.5 mm fixed with 3 mm GI wire ) for Exhaust fan 300mm sweep including proper fixing with screw in wall at existing Hole including taking down old unsv louver shutter complete all as specified and directed.
S & F Down rod 15mm bore medium grade GI pipe including cut in required length and drilled as per existing size including taking down old unsv down rod complete all as specified and directed.
S & F Fan blade for Ceiling fan of 1200mm sweep of white colour including taking down old unsv fan blade complete all as specified and drected.
Taking down old Unsv DB of any type & any capacity complete all as specified and directed
S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge. make- L&T/Havells/C&S/legrand/hager.
S & F Power line vertical type TPN DB double door 4 way, IP 43 suitable for MCCB 100 amps CRCA sheet metal enclouser with detachable gland plates for flush / surface mounting with bus bar neutral link and Earth Bar in concealed and all disturbed surfaces of wall shall be made good to match the existing wall finishes complete all as specified and directed. make- L&T/Havells/C&S/legrand/hager.
S&F metering Panel, powder coated factory made for mounting Electric meter at stair case for 4 electric meters, box should be cubical indoor type modular design of not less than 900 mm x 900mm x200mm , with 2mm thick CRCA sheet steel with IP 52 tested, fabricated by welded frame construction with CRCA frame section, compartmentalised (Modular) desing. The cable entry shall be from the bottom and top of the panel provided with suitable dia brass gland plates for provisioning specific bending radius for cable. The panel shall have opening arrangements front side mounted on hinges as and fitting fixure in wall as specified and directed .
Taking down old Unsv MCB/MCCB/RCBOs of any type & any capacity complete all as specified and directed
S & F MCB SP 6 to 32 Amp, B series , 230 Volts complete all as specified and directed . Make -Havells/C&S/legrand/hager.
S & F MCB DP 6 to 32 Amps, B series, 230 Volts complete all as specified and directed . Make - Standard/Havells/C&S
S & F MCCB 4 Pole 415V Fixed type 25-100A with breaking capicity 16 KA complete all as specified and directed. Make : L&T/Standard/Havells
Taking down the existing Unserviceable point wiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with conduit/casing caping, along with all connected accessories complete all as directed.
M&L point wiring for one light point with1.5Sqmm (Nominal Area) PVC insulated unsheathed cable FR grade with copper conductors, single core, multi stranded 1100 volts,ISI marked (IS 694) (For phase, neutral) drawn through and 20mm dia PVC rigid conduit ISI marked, heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with 3mm thick masonite or approved laminated sheet top cover for fixing switches , sockets etc, including 1.5sqmm FRLS multi stranded copper conductor cable as continuous earth wire complete and connecting the earth wire to common earth complete all as specified. Note:- All the disturbed surfaces of wall / ceiling shall be made good to match the existing wall / ceiling finishes by Putty and matching the colour of wall with the existing colour of the wall (wash/paint/distemper) wherever required(as per the existing condition) as directed by the Engineer-in-Charge.
Ditto as per Item No 99 above but for one fan / Exhaust fan point
Ditto as per Item No 99 above but for One 3 pin 5 Amp socket outlet on the same board
Ditto as per Item No 99 above but for One 3 pin 5 Amps socket out let on independent board
Ditto as per Item No 99 above but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
Ditto as per Item No 99 above but for one bell point controlled by one 5 amp switch
Ditto as per Item No 99 above but for one light point controlled by two two way switches
S & F in repair electronic fan regulator,100W ,230V ,50Hz stepped socket type for ceiling fan complete all as specified . Make- Anchor/Leader/Standard
S&F in repair switch piano type, 5 Amp. SP, one way all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG
S&F in repair switch piano type, 5 Amp. SP, two way all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG
S&F in repair socket outlet, 2 in one 5 pin, 5 Amp, piano type all as directed/ specified. Make- legrand/Anchor/ Havells
S&F in repair switch socket outlet, 2 in one 5 pin, 5 Amp, piano type all as directed/ specified. Make- legrand/Anchor/ Havells
S&F in repair switch socket combination 2 in 1, 6 pin 5 and 15 Amp flush type universal all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG
S&F in repair switch bell push, flush type, 5 Amp all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG
S&F in repair bell, AC, 230 V, SP, ding dong type all as directed & specified. Make Anchor/leader/ Bajaj
S&F in repair of Ceiling rose 3 phase, PVC/ Polycarbonate body all as directed/ specified.
Taking down submain wiring of any type complete including all its accessories complete all as specified and directed.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
Taking down old unsv LED lights of any wattage , any type including all its accessories complete all as specified and directed.
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 10 W/9W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per Make Havells Philips/Havells/CG/Orient
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 20W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as perCat No LUMILINEPLUSBS20WLED865SPCSS Make: Havells
S & F 15 Watt LED fitting, B22 base, 3 star, colour temp 6500k, including taking down old unserviceable bulb all as specified and directed by . make-Havells /phillips/bajaj
S & F angle bulb holder for LED fitting, B22 base, including taking down old unserviceable type holder all as specified and directed by .
S&F 20 W LED ,IP 66 ,230V environment friendly with operating temperature -10 to 50 degree celsius, operating voltage range 140 to 270 Volts, system lumen > 2500, colour temperature >= 5700K suitable for pole dia 43mm (max) including GI bend Pipe of length 1.5 Mtr fit for mounting including all its accessories complete all as specified and directed. Make havells model no - ENDURAPEARL 20W MP
Supply and fix air cooled split unit air conditioner electric driven single phase of capacity of 2 TR, BEE 5 star rated including drilling hole to wall and making good disturbed surface of wall as per existing complete all as specified and as directed.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated including drilling hole to wall and making good disturbed surface of wall as per existing complete all as specified and as directed.
M & L for point wiring for Power Socket with 4 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn with rigid PVC concealed conduit with all accessories incl 4 sqmm multi stranded copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity connected to common earth dolly and sunken cast pressed steel terminal box fixed flush to wall of not less than 1.6 mm thick for mounting of fittings such as switch socket Combination with 3 mm thick Laminated bakelite sheet (Make' Hylum') cover all as specified and directed.
S & F single pole and neutral enclosure with a two pin, earth plug and socket complete with one single pole MCB 230 V , 32 Amp all as specified and directed
Supply and fix refrigerator, electric driven (single phase), capacity 310 Litres.BEE 5 star rated complete all as specified and as directed.
Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star ratedcomplete all as specified and as directed.
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and as directed.
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 180 litres and nominal cooling capacity of 150 Litres per hour complete all as specified and as directed.
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour complete all as specified and as directed.
Taking down fans sealing cable ends dismantling blades and removing fan and keeping in safe custody for reuse complete all as specified and as directed.
M & L for point wiring for one light /fan point with 1.5 sqmm cable PVC insulated copper conductor multi stranded as per IS-694 FRLS cable controlled by one way switch, drawn through PVC casing capping/conduit with all accessories incl 1.5 sqmm multi strand copper conductor cable (green colour) PVC insulated and unsheathed for earth continuity connected to common earth dolly and sunken cast pressed steel terminal box fixed flush to wall of not less than 1.6 mm thick for mounting of fittings such as switch, socket and speed regulator with 3 mm thick Laminated bakelite sheet (Make' Hylum') cover all as specified and directed.
All as per Ser item No.133 above but for 5 amps socket on independent board.
All as per Ser item No.133 above but with 2.5 sqmm cables for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
S & F The Venus Neo tunable white is a range of color tunable LED recessed panels, 42 Watts, Fixture size: (LxWxH) in (595x595x65) mm that support "Human Centric Lighting". The product features color tuning from 3000 K to 6500 K with precise control on tuning and dimming and is perfect for applications such as office workstations, meeting rooms and cabins, hospitals, classrooms etc. complete all as specified and directed. Item Description: VENUSNEOTW2X2PLR42WLEDTWMOD of Make: Havells
S & F MCB DB Single pole and neutral 8 way double door with 200 amps rated bus bar complete.
S&F MCB SPN 32 Amp, 'C' Series, 10KA braking capacity 230/240 volt AC as specified and directed. Make: Havells/Legrand/L&T/Merlin Gerin/Standard
Supply and fix Energy saving and environmental friendly long life LED street light 35 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including GI bracket 1.2 mtr in length bent to shape of 120 degree with MS bracket 2 Nos, washers, nuts, bolts etc. Cat Ref : ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC of Make: Havells
Supply & fix Heavy duty Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep, 900 RPM with louver complete all as specified and as directed.
M&L for rewinding of ceiling fan,1200mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings both complete all as specified and directed
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan
M/L for Earthing complete with galvanized steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts nuts, check nut and washers of GI and GI tubing 15 mm bore, light grade for earth lead protection up to main earth test point and includingconcrete pit in PCC (1:3:6) typeC 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing(L. G.) for watering ,charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed including takingdown old unserviceable earthing as per Electrical plate no 3 of SSR Part-I.
S&F House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos900 bends. M.S.hook and stay or guy
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 2 core x 16 Sq mm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Supply and fix in repairs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position size 500 ltrs all as specified in SSR Part I.complete all as specified and as directed.
Supply and fix in repairs Tank Nipple suitable for HDPE water tank. (Minimum weight 20mm- 45gms) complete all as specified and as directed.
Taking up GI water tubing 25 mm bore from trenches / floor including all fittings, segregated and stacking the pipe complete all as directed.
Supply, lay and fix 25 mm bore galvanized iron water tubing medium grade including all fittings and fixed laid in trenches complete all as specified and directed.
Supply and fix Gun-metal, globe or gate valves 25 mm dia, with iron wheel head, screwed both ends for iron pipe and fixed
Supply and fix Ball valves 20 mm dia high epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 m m - 2 1 0 g m s) Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose.
M/s. M. G. Babloo Das
Siddheswari Construction
Chinmay Traders
M/S SEWAK SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .