SE EDC RAMPUR
office of the SE EDC RAMPUR
38/2023-24/EDCR Increasing load capacity of overloaded Transformer, replacement of VCB, Jarjar wire construction of line under Business Plan, EDD-Bilaspur, Rampur.
2023_PVVNL_838203_2
38/2023-24 (EDCR)
Open Tender
Electrical Works
Lump-sum
45 days
office of the SE EDC RAMPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC RAMPUR
₹28,000
21 Dec 2023
28 Oct 2023
4 Nov 2023
28 Oct 2023
4 Nov 2023
28 Oct 2023
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
33 KV VCB 1250 Amp
Control Pannal I/C for 33 KV Double T/F
33 KV CTR 200/100/1-1A
STP 11 Mtr Long
PCC 8.5 Mtr Long
11/0.4 KVA T/F 250 KVA
11/0.4 KVA T/F 100 KVA
ACSR Rabbit (In Mtr)
11 KV XLPE Cable 3*185 sq mm
ACSR Weasal Conductor
LT PVC Cable 3.5*400 sq mm
LT PVC Cable 3.5*240 sq mm
CABLE AL. 3X300 SQ.MM. XLPE 11 KV
Polymeric 11 KV Pin Insulator
Polymeric 11 KV Disc Insulator
33 KV VCB 1250 amp set (Recived Back Site to Store)
11/0.4 KV 100 KVA T/F(Recived Back Site to Store)
33 kv CTR 200/100/1-1A (Recived Back Site to Store)
33 KV Bus Isolator 800 A (Recived Back Site to Store)
Dismantling of HT & LT connection & replace of follwoing capacity T/F from substation double poles/plinth by Healthy transformer(including connection) and loading and unloading with associated work at both ends within 70 kms.
overloaded 100 KVA trasnformer
Installing of Healty Transformer, connection HT & LT of follwoing capacity T/F at substation Single Pole/ double poles/plinth by Healthy transformer(including connection) and loading and unloading with associated work at both ends within 70 kms.
Increasing load capacity of overloaded by separate 100 KVA trasnformer
Increasing load capacity of overloaded by separate 250 KVA trasnformer
a) Single support Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
STP 11 Mtr long
8.5 Mtr long PCC Pole
b) Double pole structure Excavation of foundation pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole)Erection of support(pole) complete with providing and fixing of all clamps made of MS flat of size 75x8 mm. an other accessories . The work includes fabrication work and fixing of cross bracing sets 3.5 Mtr from MS Angle 65x65x6 mm/50x50x6 mm. The work includes cutting holes and providing MS Bolts of 16x40 mm size in the middle of the cross bracing with 1 No. sparing washer of proper size.
8.5 Mtr long PCC Pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Single support
STP 11 Mtr long
8.5 Mtr long PCC Pole
b) Double pole structure
8.5 Mtr long PCC Pole
Providing & Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Providing and Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs (Earting complete( Rod and wire) will be provide by the contractor)
fixing of 11 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
laying ,stringing and binding of ACSR Weasal Conductor as per RESPO Norms and as per direction of Supervising Engineer.
laying ,stringing and binding of ACSR Rabbit Conductor as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 11 kvXLPE cable 3*300 sq mm as per RESPO Norms and as per direction of Supervising Engineer.
laying 11 kvXLPE cable 3.5*185 sq mm as per RESPO Norms and as per direction of Supervising Engineer.
laying Underground 11 kvXLPE cable 3.5*185 sq mm as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding LT PVC Cable 3.5*400 sq mm per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of LT PVC Cable 3.5*240 sq mmSqmm per RESPO Norms and as per direction of Supervising Engineer.
Dismentling old 33 KV VCB 1250 Amp and Installing of 33 KV VCB 1250 Amp as per RESPO Norms and as per direction of Supervising Engineer.
Installing of Control Pannal I/C for 33 KV Double T/F as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling old and jarjar CTR 33 KV CTR 200/100/1-1A and Installing of 33 KV CTR 200/100/1-1A as per RESPO Norms and as per direction of Supervising Engineer.
Providing and Installing of 33 KV Bus Isolator 800 A per RESPO Norms and as per direction of Supervising Engineer.
Providing and Installing lightening arrstor 33 KV per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling of old damaged 33 KV Bus isolator 800 A as per RESPO Norms and as per direction of Supervising Engineer.
Construction of plinth for 250 KVA Transformer 2x2x1.5 M with fencing as per RESPO Norms and as per direction of Supervising Engineer (Material for plint and fencing will be provide by the Contractor)
Providing and laying of Control Cable 4*2.5 sq mm as per RESPO Norms and as per direction of Supervising Engineer
Providing and laying of Control Cable 2*2.5 sq mm as per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Stone pad
Providing and fixing 11 KV X Arm MS Angle 65*65*6 mm
Providing and fixing MS Channal (Dropper) 100*20*2028 mm
Providing and fixing MS Channal(Top) 125*65*2240 mm
Providing and fixing MS Angle 65*65*6*1200 mm with clamp & Bolt and Nut(T/F Base)
Providing and fixing MS Angle 65*65*6*1700 mm with clamp & Bolt and Nut(T/F Base)
Providing and fixing 11 KV cable jointing kit (3x300 sqmm)
Providing and fixing 11 KV cable jointing kit (3x185 sqmm)
Providing and fixing T-channel with Nuts and Bolts
Providing and fixing F-Bracket with Nuts and Bolts
Providing and fixing Clamp with Nut bolts
Providing and fixing Clamp with Nut bolts T/F base
Providing and fixing Clamp with nut bolts for Holding X- Arms
Providing and fixing Danger Board with Fixing Clamp
Providing and fixing GI wire 8 SWG
Providing and fixing Nut and bolt (off size)
Providing Red Oxiding and Painting
Providing Enamel paint(silver colour) and Painting
M/S MEGHA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .