Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.8 L+₹60,281.64 (3.32%)Rejected-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹20.0 L+₹1.8 L (10.1%)Rejected-AOC 199 79 SADAR BAZAR LANSDOWNE TAHSIL LANSDOWNE | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
17 Nov 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
PROVISION OF FRESH ISSUE SHED AT 433 I SUP PL ASC AT LANSDOWNE UNDER AGE I LANSDOWNE
2021_MES_481456_2
87071/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
AGE(I) Lansdowne
class E Cat a i
6 documents required · 6 mandatory
₹500
AGE(I) LANSDOWNE
₹46,000
Yes
7 Dec 2021
27 Oct 2021
19 Nov 2021
27 Oct 2021
17 Nov 2021
5 Nov 2021
27 Oct 2021 - 3 Nov 2021
Amount
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
M & L for morrum/red bajri filling in floors or pavings, laid in layers n.exc.15cm thick, spread,levelled and rammed including watering complete all as specified and directed.
M & L for cement concrete type D2, 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M & L for RCC M-25 using 20mm graded aggregate as in footings, fdn beams, plinth beams, bases for colmns etc complete all as specified and directed.
All as per item No 05 above but in columns complete all as specified and directed.
All as per item No 05 above but in beams and lintels over 1.5 m Span etc complete all as specified and directed.
All as per item No 05 above but concrete for chajjas complete all as specified and directed.
M&L for form work to sides of footing and plinth beams finished fair and rough complete all as specified and directed.
All as per item No. 09 above but for columns. complete all as specified and directed.
All as per item No. 09 above but for sides and soffits of beams and lintels complete all as specified and directed.
All as per item No. 09 above but for suspended slabs such as roof slabs etc complete all as specified and directed.
All as per item No. 09 above but for suspended chajjas complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No. 14 above but 5 mm dia and over upto and including 10mm dia in stirrups, spaces and binders complete all as specified and directed.
Returning filling in incl spreading leveling watering and well ramming in layers n.exc 25 cm in thickness complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for cement concrete 1:4:8 type D-2 (75mm thick) using 40mm graded aggregate as in sub base complete all as specified and directed
M&L for coloured vitrified tiles of any design and pattern, 600x600x9 to10 mm thick, as in floor etc incl 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b with average water absorption between 0.08% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max Deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) Complete all as specified and directed
Material & Labour for 450 x 350 x 7 to 8mm thick light colour glazed ceramic tiles of any design and pattern, as in dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile. Tiles shall be confirming to IS-15622:2007, Group B III with average water absorption between 10% to 15% length, width and strightness of sides + 0.20% (Max Deviation). Thickness +4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (max deviation) surface flatness +0.22% (Max deviation) Breaking strength 500N (Minimum) and minimum 95% tiles shall be free from visible defects including 10mm thick in CM (1:4) as a backing coat and including dismantling of old tiling complete all as specified and directed. Note Shade of the tiles including colour design and pattern shall be approved by AGE (I) Lansdowne.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 75 mm wide inserted in position complete all as specified and directed.
M & L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M & L for Rendering 15 mm thick in two coats i.e. 1st coat 10 mm thick in CM 1:6 and 2nd coat 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only liquid water proofing admixture ISI Marked of make-pidilite or equivalent.complete all as specifed and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
S & F structural rolled mild steel as in roof trusses (framed) purlins crane gantries, rail and fastening and heavy brckets framing (beam, tee angle, channel or flat section) including distance pieces, cleats etc or FE-290 9gde E-165) complete all as specified and directed
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ -150) as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as Specified & directed by GE/Eng-in-Charge.Make - Tata Durashine , JSW Colouron+ or equivalent in Roffit( Shiv Shakti Fibre Udyog)
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ- 150) as in ridges, hips, valleys/rain water / roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.Make - Tata Durashine , JSW Colouron+ or equivalent in Roffit( Shiv Shakti Fibre Udyog)
M & L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
Supply & Fixied in repair ,tiled false ceiling of Everest tile (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gsm, both side inclusive and black painted groove on all T webs) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32mm made of 0.30mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20x0.40 mm and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width,including making good all the disturbed portion with existing surface with necesary arrangemnets of scaffolding all complete at all heights as per direction of Engineer-in-charge.
S & F powder coated anodised aluminium frame for doors, windows, ventilators and partition with one or more rebates including joining cleat for fixing etc complete all as specified and directed
S & F powder coated anodized aluminium door shutters aluminium section weighing 0.55 Kg/M including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges anodised aluminum snap beading screws etc complete all as specified and diretced.
S & F powder coated anodized aluminium windows and ventilator shutters aluminium section weighing 0.55 Kg/M including necessary joining cleats, glazing clips rubber packing anodised aluminium snap beading screws locking arrangement etc complete all as specified
S & F for sheet glass 5.50mm thick tinted quality and glazing including fitting rubber gasket of approved quality, ISI Marked duly approved by AGE (I) complete all as specified and directed by Engr-in-Charge
M & L 12mm thick Pre-laminated particle board exterior grade ISI Marked duly approved by AGE(I), prelaminated both side with decorative choice laminations fixed in aluminium doors/Aluminium Partition etc complete all as specified and directed.
S & F brass mortice lock (4 levers), vertical type size 100mm long, ISI Marked duly approved by AGE (I) complete all as specified and directed by Engr-in-Charge
S & F Floor door stopper 150mm long of aluminium alloy body and tongue ISI marked duly approved by AGE (I) anodised with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F Aluminium extruded Door closer hydraulically regualted desigantion No 2( heavy duty) (ISI Marked) , universal type, suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 Kg Complete all as specified and directed
S&F for Stainless steel wire cloth non megentic of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples, fixed in repairs.Complete all as specified and directed
S & F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars: barred iron doors, ladders framed balusters walkways railings frame work or wter tanks and similar work conforming to Fe-290 Gde E-165
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item no. 45 mentioned here-in-before but One 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch.
All as per item no 45 mentioned here-in-before but One socket outlet 5/3 pin 5 Amps controlled by one switch on independent board.
All as per Item No 45 mentioned here-in-before but one three pin 15 Amps Switch Socket outlet on independent board with 2.5 sqmm PVC insulated FRLSh copper conductor and 2.5 Sqmm FRLSH copper conductor for contineous earthing complete
Supply and fixing switch modular, one way 6 Amps, 1 module 240 volts, AC, ISI marked complete all as specified .
Supply and fixing switch modular one way 16 Amps, 1 module, 240 vlts, AC, ISI marked complete all as specified .
Supply and fixing modular socket, 6 A, 2/3 pin combined 2 module complete, ISI marked all as specified
Supply and fixing modular socket, 6 A/16 A 2/3 pin combined 2 module compelte ISI marked all as specified
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked all as specified and directed Make : Anchor/ Cona / Havells
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and as directed. . Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.Make:- Legrand,Schneider,Siemens,L&T,
S&F LED tube light batten 20 Watt, 4ft, Polycarbonate housing, translucent diffuser, With LED Light Source, 2200 Lumens, natural White, Surge Protection range- 2KV, Voltage Protection range – 120 -280VAC, 2 years warranty , System efficacy not less than 110Lm/Watt for the fitting, power factor >0.95, total harmonic distortation<20%, Color rendering index >80, Coefficient Colour Temperature – 6500K, Fixed on site with all accessories all as specified & directed. Cat No: SZSLBMX020 of shakti Cat No,C&S LTTB4F20WLEDof C&S LM79 and LM 80 Reports to be produced. BIS Certification must.
S&F 36 Watt, 3600 lumens LED Panel 2X2 environmental friendly, fully diffused, using engineering grade polycarbonate diffuser, new generation, aesthetically designed, CRCA housing, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.98, thd<15%, CCT 6500K, 2 Yrs warranty complete with separate electronic driver ceiling light 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed, Cat No : LTLRP36WLED 2X2 of C&S/ SZSZRMX036. of Shakti/ equivalant in Havells/ Wipro. LM79 and LM80 reports to be produced.
S&F sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 4 Sqmm with 4 Sqmm FRLSH PVC insulated, unsheathed, stranded copper conductor cable as earth wire in existing surface/recessed steel/PVC conduit and earth wire connected to common earth dolly all as specified & directed. Note: Three run of 4 sqmm cable shall be measured as one unit Make:- Havells,KEI,Universal,RPG,Gloster
S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter,AC single phase 230/240 Volt ,50HZ,RPM 1200,Copper windingof 300 mm sweep complete including making hole and making good the disturbed sufaces of wall all as specified and directed by Engr-in-charge .
S& F ON load change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps Make:INDO ASIAN,HAVELLS,
S&F new LED flood light fitting 50 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on ground with 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from distribution box to light complete all as specified and as directed by Engr-in-Charge (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRSno Make:-Havells Cat No-JETACOMPECTOFL50WLED757LTG or equivalent make in Wipro/Shakti
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16 sqmm 2 core complete all as specifed and directed. Note:- The Earth work,GI pipe Shall be measured and paid Sepretely under appropriate item of Sch A
Material and Labour for sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. (Note:- Punned thickness shall be considered for payment purpose.)
Supply and laying well burnt clay brick old size class 'B' laid dry flat for protection over the cable, width equal to the length of brick complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 32 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road for cable protection etc. complete all as specified and directed .
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Panwar Electrical
M/S Balaji Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .