Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.6 L+₹13,455.40 (0.53%)Rejected-Finance | L2 | Rejected-Finance Second Lowest |
Tender Value
Refer Docs
EMD Value
₹51,800
Closing Date
5 Aug 2023, 6:00 pmClosed
Major S N Gaikwad
Holta Cantt Palampur
PROVN OF CONNECTING PASSAGE LINKING TO OPD MED WARD ICU HOSPITAL LAB AND FAMILY WARD WITH EXISTING CONNECTING PASSAGE AND PROVN OF VEH COVERED PARKING FOR 04 X HEAVY VEH AND 04 X LT VEH AT PLP MIL STN
2023_MES_608368_1
GEP-36/2023-24
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹51,800
31 Aug 2023
8 Jul 2023
7 Aug 2023
8 Jul 2023
5 Aug 2023
22 Jul 2023
Amount
Excavation post holes (or similar holes) in any type of soil each n exc 0.50 cu.m,getting out,returning,filling on and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25cm, complete all as specified and directed.
S&F mild steel roof trusses (framed), trussed, purlins, crane gantries. rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe 410-W (Grade E-250) complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,without any attachment of Fe 410 W (Gde-E-250) complete all as specified and directed.
M&L preparing new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer surfaces of any description, not otherwise described, over 10cm width or girth complete all as specified and directed.
M&L pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, facia and fixed with self tapping screws as specified. (Colour as approved by GE)
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, compete all as specified and directed. (Colour as approved by GE)
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and paving's not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L 100mm thick PCC 1:3:6 type C-2 (40mm graded crushed stone aggregate) as in sub base of floors/ paver block/ path etc finishing the surface even & rough without using extra cement complete all as specified and directed.
M&L 75mm thick PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in floor, over sub base, finishing the surface even & rough without using extra cement complete all as specified and directed.
M&L broken stone or boulder hardcore of gauge n exc.63mm,deposited,spread and levelled in layers n exc,15 cm thick,watered and rammed to a true surface complete all as specified and directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L walling of random rubble, un-courses, well bonded bedded & solidly hearted built in cement mortar 1:6, complete all as specified and directed.
M&L raised pointing to random or polygonal rubble, uncoursed or brought upto courses built in CM 1:3 complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLSH) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed. Notes : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing 'N' capping shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
All as per the description of serial item No 18 here-in-before but one 5 pin socket outlet, 6 amps on the same board complete all as specified and directed.
All as per the description of Serial item No. 18 above but one 5 pin socket outlet, 15/16 Amp on independent board with cable 2.5 Sqmm size complete all as specified and directed.
S&F switch piano, flush type single pole one way 6 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F switch piano, flush type single pole one way 16 Amp, 240 volts ISI marked complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 6 A complete all as specified and directed.
S&F socket 3 pin, 6/16 amp flush type, 240 volts ISI marked complete all as specified and directed.
S&F ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified and directed.
Supply & fixing surface /wall mounted light fitting pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make:- Cat Part No for batten:- STREAKT8UPTO 1X22WSSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved. Cat Part No for Tubelight:- PHOTANULTRAE2.0 1213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LED tube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
M&L for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F in replacement 240V, 10 KA 'C' curve MCB of single pole and current carrying capacity 6 to 32 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F 240V, 10 KA 'C' curve MCB SPN of current carrying capacity 32/40 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 10 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
S&F 240V, 10 KA 'B' curve MCB SP of current carrying capacity 6 to 32 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement 240V, 10 KA 'B' curve MCB SPN of current carrying capacity 32/40 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supplying laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 10 Sqmm 2 core flat cable complete all as sepcified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc 1.5m in depth for foundation etc for laying, errection of poles struts/stays etc including taking out cable cover or stone slab, not exceeding 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning filling including spreading levelling water and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing excavated soil (any type) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L sand cushioning to underground cable with using fine river sand and gently punning for cushioning to cable complete all as specified and directed.
M&L old size brick class 'B' as in cable protection laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connecting to GI earth wire of size 4mm size by means of bolts, nuts, check nuts and protected by provision of GI medium grade pipe of 15mm bore including provision of 40mm tk cover of RCC (1:2:4) reinforced with XPM (wt no less than 4Kg/sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm dia pipe for watering of suitable length placed on tp edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and excavation and earthwork in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as per plate No. 3 of SSR 2009 Part-I and connecting to earth test point all as specified and directed by Engineer-in-Charge and including testing on completion.
Note:-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B1, 80mm thick reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe up to 7.50m and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and the rate includese in the unit rate of item. (iv) The earth chamber shall be constructed 5m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate for this item.
S&F 32mm bore galvanized iron, light grade (ISI marked) made to trenches/fixed on wall/pole etc. for protection of cable including taking out old tubing complete all as specified and directed.
BHARDWAJ BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .