Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹34.7 L+₹3.9 L (12.5%)Rejected-Finance 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L2 | Rejected-Finance Not being L1 | |
| 3 | Rejected-Technical 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | - | Rejected-Technical NO in WLR HQ CECC |
Tender Value
₹35.4 L
EMD Value
₹70,700
Closing Date
16 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BAREILLY
HQ CWE AF BAREILLY- 243002
PROVISION OF RING MAIN SYSTEM AND UPGRADITION OF POWER CAPACITY AT AF STATION BHOWALI.
2023_MES_619633_1
81388/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) AF BHOWALI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE(I) AF BHOWALI
₹70,700
Yes
26 Dec 2023
19 Sept 2023
18 Oct 2023
19 Sept 2023
16 Oct 2023
3 Oct 2023
19 Sept 2023 - 26 Sept 2023
Amount
Supply, installation and commissioning of 11kv, 400A, non extensible outdoor,fixed type (IP 54) RMU (Ring main Unit) 4-Way comprising two No VCB as Incomers & 2 No Vaccum circuit breaker as outgoing , inside robotically welded stainless steel SS441 grade and tank havin min, thickness 2 mm & IP67 Degree protection. RMU should be provided with internal bus bars as well as earthing bus bar should be of copper, one number fault passage indicator per unit padiock provision & complete with accessories. The RMU shall be type tested for internal arc test of 20 KV/1 Sec as per IEC 62271-220. The earthing of cable shields. The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP54 protection. The unit shall include the following with all necessary standard fitting as required at site - (a) 2 Nos Incoming 400 Amp motorised Vaccum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 20 KA for 3 seconds with copper bus bar and copper earth bar fitted high fixed type voltage indicator device as per IEC 61958-1 fully rated with earth switch, spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm. (b) 02 No Outgoing 400 Amp motorised Vaccum circuit breaker, triple pole single break 3 position (On, Off and earth having STC capacity 20 KA for 3 seconds with copper bus bar and copper earth bar fitted high fixed type voltage indicator device as per IEC 61958-1 fully rated with earth switch, spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 sqmm.
(C) And bus bar with bus Connected PT Unit-01 No for metering consisting of following :- (i) Type M : Air insulated metering module 12 KV, 400A 20 KA for 3 sec. (ii) Voltage transformers of the ratio 11 KV/1.732/110 V/1.732.25 VA Class 1.0 with HT fuses on primary side and MCB on secondary side. (iii) Digital MFMs with 485 port to measure Amps, Volts, Frequency, PF, KWH, KVRA (iv) CFLs for illumination. (v) Space heaters with thermostat. (vi) RYB phase indicator (vii) Cable support busbar, stand for 3 way unit, 1 monometer & 1 operating handle. (viii) Set of bushing for external bushbar connection along with bushbar cover & sleeved bushbars for coupling. (ix) 2x12 V Battery with battery charger of suitable burden for motor operation. Input 230 V AC & output 24 V DC. (d) Capacitive voltage indicator fixed type VPIS 9-15KV. (e) necessary interlocking arrangement for sefty and operation. (f) operating handles for manual operation. (g) Mono meters. (h) Safety interlock shall be provided as per relevant IEC/IS standard and manufactures directions.
(j) Safety interlocks shall be provided as relevant IEC/IS standard and manufactures directions. (k) Above switchgear shall confirm to all relevant IEC/IS standard. (l) Manual operation of vacuum circuit breaker should be possible without dismantling the motor from RMU. the motor should be fitted in such a way that it should not be outside from covers of RMU. (m) Coupling of RMU and metering module should be with the help of bolted type arrangement so that the coupling at site shall be easy. Plug in type bushing shall not be acceptable. (n) Minimum 3 module should accommodate in one tank to avoid multiple coupling at site. (o) The switchgear shall have built in programming logic using reputed make PLC (ACS500/Equip) for automatic change over between two motorized incomer VCB and shall derive voltage reference from incoming supply in respective incomer. PLC shall also be wired to all VCB's to monitor open/close 3+0.5 status. PLC should have communication facility over MODBUS protocol. (p) Three set of remote operation & control kits for motorisation & operation of PLC. (q) Three set of signal converter for PLC operation. (r) The auto changeover for incoming feeders shall be done within 10-15 second. (s) The PLC shall programmable at factory as well as site for accommodating future requirements as per manufacturers instruction for auto changeover for feeders. (t) PCC 1:2:4 type B1 using 20 mm graded aggregate for foundation of RMU as per recommendation of manufacturers & as directed by Engr-in-charge. Note :- Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the RMU system shall be included in the items and are covered against the quoted rate.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade of size 95 sq mm 3 core.complete all as specified and directed.
M&L cable jointing kit for 11 KV (E) grade cable for outdoor heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 70 to 120 Sq mm 3 Core complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc or /getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cables with 8 CM thick before laying of cables and 15 CM thick after laying and stretching of Cable complete all as specified and directed. Note : Only punned thickness i.e. 18 CM shall be measured and paid.
M & L for sub class 'B' brick for covering to under ground cable laid flat transversally width equal to the lenth of the cable complete all as specified and directed.
Material and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper earth strip 20x3mm size (upto 7.5 metre from ground electrode) by means of copper/brass bolts, nuts, check nuts and washers all as shown in electrical plate No.3 of MES Schedule Part-I, connected to earth test terminal block and testing on completion with and including 40mm bore light grade GI protection pipe for strip upto plinth protection, PCC pit in mix 1:3:6 type C1, with RCC 1:2:4 type B-1, 40 mm thick cover, reinforced with 6 mm dia MS bars 3Nos. both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete.
Vishal Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .