Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 268 237 MASTER KANHAIYA LAL ROAD AISHBAGH AISHBAGH LUCKNOW UTTAR PRADESH 226004 UDYAM UP 50 0018557 | LUCKNOW | UTTAR PRADESH | 226004 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹14.9 L
Closing Date
2 Jun 2025, 12:30 pmClosed
Managing Director
3rd Floor UPSTDC Ltd Gmoti Nagar Lucknow
Tourism development work of Tulsi Math Temple under Nath Corridor in Bareilly district.
2025_STDCL_1041887_1
4408/Pari-5/Nivida Suchna/2025-26
Open Tender
Civil Works
540 days
Bareilly
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,714
UPSTDC Ltd
₹14.9 L
3rd Floor UPSTDC Ltd Gmoti Nagar Lucknow
10 Jun 2025
23 May 2025
2 Jun 2025
23 May 2025
2 Jun 2025
23 May 2025
26 May 2025
BHANDARA/SATSANG HALL Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : All kinds of soil D.S.R. Item No. 2.2.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil D.S.R. Item No. 2.28.1
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Brick work in foundation 1st class b/work in 1:4cement and coarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.4.1
12 mm thk plaster (1:4) with cement & Coarse Sand Ground Floor D.S.R. Item No. 13.4.1
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)D.S.R. Item No. 13.5.1
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. Item No. 13.80
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate D.S.R. Item No. 11.3.1
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). D.S.R. Item No. 13.46.1
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. D.S.R. Item No. 13.45.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm(make:Asian/Berger/Dulux)D.S.R. Item No. 13.48.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & lengthSecond class teak woodD.S.R. Item No. 9.1.1
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws, Second class teak wood35 mm thick shutters shall be paid separately as item 9.1.1.) D.S.R. Item No. 9.5.1.1
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)D.S.R. Item No. 13.116
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).D.S.R. Item No. 9.147A.3
6 mm thick clear heat strengthened glass DSR item 2618
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete D.S.R. Item No. 11.23.1
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). D.S.R. 2021 Item No. 10.28
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating and chemical barrier under and around the columns pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit ete. Complete (Plinth area of the building at ground floor only shall be measured as per I.S.6313(part ii 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows. I- Treatment for masonry and foundatrion 5 litres per sqm II- Back fill in immediate contact with foundation 7.5 liters/sqm. III- Treatment of top surface of plinth filling 5 liters per sqm IV- Treatment junction of soil along extemal per meter building 7.50 litre/sqm. V- Treatment of soil under apron along extemal perimeter 5 Iiter/ sqm. DSR Item No. 2.35.3.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R 2021No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R. No.12.22.1
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels plain white marble/ udaipiur green marble / zebra balck marble area of slab upto 0.50 sqm Ground Floor DSR Item No. 8.2.2.1
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. DSR 2021 Item no. 8.5
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work DSR 2021 Item no. 8.3.2
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Flat surfaces D.S.R. 12.31.1
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : For False ceiling with POP. Analysis
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X4.0 sqmm + 1x 4.0 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. make:Schneider/RR Kabel/Northwest
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required.
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. make:Schneider/RR Kabel/Northwest/Bajaj
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep.
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required.
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as requir
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Schneider/RR Kabel/Northwest Single Pole
Double Pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. Make: As approved in U.P.P.W.D & C.P.R.I.
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 16 sqmm 3.5 core
Supply and erection of 1X10 W mirror light complete in all respects Make : Philips/Bajaj
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. Make : Philips/Bajaj
Supply and fixing of LED Sqaure Ceiling light 36 to 46Watt. Make : Philips/Bajaj
Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat. AAA
Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.- 300mm sweep.
Providing & fixing Wall Bracket Light 3w
Providing & Fixing Wall Focus Light 7 Watt
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040x200mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. a) 32mm dia
b) 40mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. Make: Jaquar
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & makinggood the walls etc. Exposed on wall 25mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 15mm dia nominal outer dia pipes
20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 , 15mm nominal bore
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore
20 mm dia nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.
Providing & Fixing PVC Pipe 100mm diameter
Providing & Fixing PVC Pipe 150mm diameter
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe
150mm diameter S.W. Pipe
Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). (i) For Sewer Line
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
FIRE FIGHTING WORKS. SUB HEAD - I (WET RISER SYSTEM - EQUIPMENTS) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 4.2
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 1.2 Meter high and 250 mm dia.
Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. MR
SUB HEAD - II - (PIPING, VALVES AND ACCESSORIES) SLTC of M.S. pipe on surface Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. Make : Tata/Jindal 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_11.5
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_14.5
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. DSR & AOR Wet Riser & Sprinkler 2019_13
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926. MR
SUB HEAD - III - (HYDRANTS SYSTEM) Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel 9.2
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) 16.2
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 18.2
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30M 17.1
SITC weather proof M.S Door and glass fire door size 2100 mm x 900 mm or as per arch. Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - a) Gunmetal single headed Hydrant valve - 1 No. b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c) Short branch - 1 No. d) First Aid hose Reel - 1 No. e) Fire Extinguisher - 2 Nos. f) Fireman's Axe - 1 No. g) Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade. MR
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
SUB HEAD - IV - (FIRE EXTINGUISHERS) Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm houter with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 21.1 Pendent Sprinkler
LIBRARY Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil D.S.R. Item No. 2.2.1
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. D.S.R. Item No. 2.8.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
C.C. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Brick work in foundation 1st class b/work in 1:4cement and couarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.4.1
Brick work in SUPER STRUCTURE in 115cm thk wall with 1:3 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.12.1
12 mm thk plaster (1:4) with cement & Coarse Sand Ground Floor D.S.R. Item No. 13.4.1
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. Item No. 13.80
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate D.S.R. Item No. 11.3.1
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). D.S.R. Item No. 13.46.1
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. D.S.R. Item No. 13.45.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (make:Asian/Berger/Dulux) D.S.R. Item No. 13.48.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length Second class teak wood D.S.R. Item No. 9.1.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws D.S.R. Item No. 9.21.1
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only D.S.R. Item No. 9.22.1
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (Zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).D.S.R. Item No. 9.147.A4.2
6 mm thick clear heat strengthened glass DSR item 2618
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete D.S.R. Item No. 11.23.1
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). D.S.R. 2021 Item No. 10.28
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating and chemical barrier under and around the columns pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit ete. Complete (Plinth area of the building at ground floor only shall be measured as per I.S.6313(part ii 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows. I- Treatment for masonry and foundatrion 5 litres per sqm II- Back fill in immediate contact with foundation 7.5 liters/sqm. III- Treatment of top surface of plinth filling 5 liters per sqm IV- Treatment junction of soil along extemal per meter building 7.50 litre/sqm. V- Treatment of soil under apron along extemal perimeter 5 Iiter/ sqm. DSR Item No. 2.35.3.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R 2021No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R. 2021 No.12.22.1
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels plain white marble/ udaipiur green marble / zebra balck marble area of slab over 0.50 sqm Ground Floor DSR Item No. 8.2.2.1
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. DSR 2021 Item no. 8.5
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work DSR 2021 Item no. 8.3.2
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Make : Kajaria/ Simpolo/Johnson) DSR 8.31
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. DSR 9.76
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. DSR 9.77
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finishof tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board Ground floor DSR 12.45.3
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Flat surfaces D.S.R. 12.31.1
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : For False ceiling with POP. Analysis
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws, Second class teak wood35 mm thick shutters shall be paid separately as item 9.1.1.) D.S.R. Item No. 9.5.1.1
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) D.S.R. Item No. 13.116
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X4.0 sqmm + 1x 4.0 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. make:Schneider/RR Kabel/Northwest
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. make:Schneider/RR Kabel/Northwest
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. make:Schneider/RR Kabel/Northwest/Bajaj
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. make:Schneider/RR Kabel/Northwest/Bajaj
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep.
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required.
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). make:Schneider/RR Kabel/Northwest 12 way, Double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Double Pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. Make: As approved in U.P.P.W.D & C.P.R.I.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia(Rate taken From Civil DSR 2021-18.12)
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 10 sqmm 2 core
Supply and erection of 1X10 W mirror light complete in all respects
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect.
Supply and fixing of LED Sqaure Ceiling light 36 to 46Watt.
Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects.
Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.- 300mm sweep.
Providing & fixing Wall Bracket Light FAÇADE --3w
Providing & Fixing Wall Focus Light 7 Watt
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040x200mm
Providing and fixing white sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. a) 32mm dia
b) 40mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110 mm diameter
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & makinggood the walls etc. exposed wall 25mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc 15mm dia nominal outer dia pipes
20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore
20 mm dia nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.
Providing, laying PVC Pipe 100mm diameter
Providing, laying PVC Pipe 150mm diameter
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe
150mm diameter S.W. Pipe
Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P typeWith Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
FIRE FIGHTING WORKS. SUB HEAD - I (WET RISER SYSTEM - EQUIPMENTS) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 4.2
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 1.2 Meter high and 250 mm dia.
Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. MR
SUB HEAD - II - (PIPING, VALVES AND ACCESSORIES) SLTC of M.S. pipe on surface Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : Make : Tata/Jindal 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.7
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. Make : Tata/Jindal 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_11.5
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_14.5
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. DSR & AOR Wet Riser & Sprinkler 2019_13
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926. MR
SUB HEAD - III - (HYDRANTS SYSTEM) Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel 9.2
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) 16.2
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 18.2
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30M 17.1
SITC weather proof M.S Door and glass fire door size 2100 mm x 900 mm or as per arch. Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - a) Gunmetal single headed Hydrant valve - 1 No. b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c) Short branch - 1 No. d) First Aid hose Reel - 1 No. e) Fire Extinguisher - 2 Nos. f) Fireman's Axe - 1 No. g) Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade. MR
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
SUB HEAD - IV - (FIRE EXTINGUISHERS) Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. DSR E&M 2018_
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. DSR E&M 2018_
Supplying, installation, testing & commissioning fire alarm houter with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. DSR E&M 2018
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required. DSR E&M 2018_17.5.1
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 21.1 Pendent Sprinkler
PRASHAD & FLORIST SHOP Excavation in foundations in ordinary soil Loame, clay or sand including lift upto 1.5 m. lead upto 30 m.inciuding filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the Engineer i/c upto a distance of 30 m from the foundation trenches. (excluding Royalty) D.S.R. Item No. 2.2.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
C.C. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Brick work in foundation 1st class b/work in 1:4cement and couarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. D.S.R. Item No. 6.4.1
Class 150 Brick work in 1:3 cement and Coarse Sand of 1.25 finentss modulusbut in Parapet including necessary cutting and moulding of brick work as required and also including honey combed brick work in thickness of wall more than 12 cms. D.S.R. Item No. 6.13.1
12 mm thk plaster (1:4) with cement & Coarse Sand D.S.R. Item No. 13.4.1
15mm cement plaster on rough side of single or half brick wall finished with 1:4 (1 cement : 4 coarse sand) D.S.R. Item No. 13.5.1
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick D.S.R. Item No. 11.26.1
Supplying and fixing rolling shutters of approved make of 80x125mm (3x3½") guage cold rolled M.S. laths inter locked throuhout their entire length and joined together at the end by end locks and nmounted on specially designed pipe shaft with brackets side guides and arrangement for inside and outside locking with push and pull operations complete but excluding the cost of top cover and spring. DSR 10.6.1
Providing and fixing ball bearing for rolling shutters SOR-523 D.S.R. 10.7
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR Item No. 13.80
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (make:Asian/Berger/Dulux) D.S.R. Item No. 13.48.1
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. D.S.R. Item No. 13.45.1
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture D.S.R. Item No. 13.62.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R.No.12.22.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X4.0 sqmm + 1x 4.0 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required.
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. make:Schneider/RR Kabel/Northwest/Bajaj
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required.
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. make: Bajaj/Havells/Crompton
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). make:Schneider/RR Kabel/Northwest
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double Pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 10 sqmm 2 core
Supply and erection of 1X10 W mirror light complete in all respects
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect.
Main Dwar Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. D.S.R. Item No. 2.8.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Brick work in foundation 1st class b/work in 1:4cement and couarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. D.S.R. Item No. 6.4.1
12 mm thk plaster (1:4) with cement & Coarse Sand Ground Floor D.S.R. Item No. 13.4.1
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) D.S.R. Item No. 5.11.1
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Whitesand stone - 30mm thick gang saw cut stone D.S.R. 8.20.2
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). D.S.R. Item No. 8.21
Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : White sand stone D.S.R. Item No. 7.12.2.2
Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : Circular or polygonal pillars D.S.R. 7.21.2
Extra for stone work ashlar sunk or moulded in cornices D.S.R. 7.22
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. dsr 8.22
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 160 mm DSR Item No. 10.27.5
Providing and fixing Decorative Stone Shikhar Large size as per drawing with all complete fitting excluding dowels and anchor bolts. M.R.
Providing and fixing Decorative Stone Shikhar small size as per drawing with all complete fitting excluding dowels and anchor bolts. M.R.
Providing and fixing Ornamentol Stone Jhallar size as per drawing with all complete fitting excluding dowels and anchor bolts. M.R.
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 7.33.2 White sand stone D.S.R. Item No. 7.33.2
Providing & Fixing of 3D Sand Stone Pink Bansi Pahadpur Cladding works with 3D carving as per specified sculpture as per required thickness on Boundary wall all complete as per direction of Engineer-in-charge. M.R.
Providing and fixing sculptures in cement concrete incl all fixtures as per design by local artisans and including golden/bronze andother painting As Per Market Rate
Providing and fixing Peacock sculptures in cement concrete incl all fixtures as per design by local artisans and including golden/bronze andother painting As Per Market Rate
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X4.0 sqmm + 1x 4.0 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required.
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep.
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required.
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. make: Bajaj/Havells/Crompton
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Double Pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. Make: As approved in U.P.P.W.D & C.P.R.I.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia(Rate taken From Civil DSR 2021-18.12)
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 10 sqmm 2 core
Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects.
Providing & fixing Wall Bracket Light FAÇADE -3w
Providing & Fixing Wall Focus Light7 Watt
DHARAMSHALA Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : All kinds of soil D.S.R. Item No. 2.8.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil D.S.R. Item No. 2.28.1
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Brick work in foundation 1st class b/work in 1:4cement and coarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.4.1
Brick work in SUPER STRUCTURE in 115 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.12.1
12 mm thk plaster (1:4) with cement & Coarse Sand Ground Floor D.S.R. Item No. 13.4.1
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) D.S.R. Item No. 13.5.1
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. Item No. 13.80
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate D.S.R. Item No. 11.3.1
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). D.S.R. Item No. 13.46.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm D.S.R. Item No. 13.48.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length Second class teak wood D.S.R. Item No. 9.1.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws D.S.R. Item No. 9.21.1
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only D.S.R. Item No. 9.22.1
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). D.S.R. Item No. 9.147A.3
6 mm thick clear heat strengthened glass DSR item 2618
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete D.S.R. Item No. 11.23.1
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating and chemical barrier under and around the columns pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit ete. Complete (Plinth area of the building at ground floor only shall be measured as per I.S.6313(part ii 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows. I- Treatment for masonry and foundatrion 5 litres per sqm II- Back fill in immediate contact with foundation 7.5 liters/sqm. III- Treatment of top surface of plinth filling 5 liters per sqm IV- Treatment junction of soil along extemal per meter building 7.50 litre/sqm. V- Treatment of soil under apron along extemal perimeter 5 Iiter/ sqm. DSR Item No. 2.35.3.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R 2021No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R. No.12.22.1
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels plain white marble/ udaipiur green marble / zebra balck marble area of slab over 0.50 sqm Ground Floor DSR Item No. 8.2.2.1
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. DSR 2021 Item no. 8.5
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work DSR 2021 Item no. 8.3.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X4.0 sqmm + 1x 4.0 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required.
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. make:Schneider/RR Kabel/Northwest/Bajaj
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep.
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required.
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. make: Bajaj/Havells/Crompton
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Double Pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Make: As approved in U.P.P.W.D & C.P.R.I.
Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. Make: As approved in U.P.P.W.D & C.P.R.I.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia(Rate taken From Civil DSR 2021-18.12)
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 16 sqmm 3.5 core
Supply and erection of 1X10 W mirror light complete in all respect
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect.
Supply and fixing of LED Sqaure Ceiling light 36 to 46Watt.
Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat. AAA
Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required. 300mm sweep.
Providing & fixing Wall Bracket Light -3w
Providing & Fixing Wall Focus Light 7 Watt
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. a) 32mm dia
b) 40mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. Make: Jaquar
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & makinggood the walls etc. (internal work) Exposed on wall 25mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes
20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore
20 mm dia nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.
Providing, laying PVC Pipe 100mm diameter
Providing, laying PVC Pipe 150mm diameter
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe
150mm diameter S.W. Pipe
Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
FIRE FIGHTING WORKS. SUB HEAD - I (WET RISER SYSTEM - EQUIPMENTS) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 4.2
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 1.2 Meter high and 250 mm dia.
Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.
SUB HEAD - II - (PIPING, VALVES AND ACCESSORIES) SLTC of M.S. pipe on surface Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.7
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. Make : Tata/Jindal 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_11.5
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_14.5
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. DSR & AOR Wet Riser & Sprinkler 2019_13
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926.
SUB HEAD - III - (HYDRANTS SYSTEM) Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel 9.2
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) 16.2
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 18.2
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30M 17.1
SITC weather proof M.S Door and glass fire door size 2100 mm x 900 mm or as per arch. Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - a) Gunmetal single headed Hydrant valve - 1 No. b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c) Short branch - 1 No. d) First Aid hose Reel - 1 No. e) Fire Extinguisher - 2 Nos. f) Fireman's Axe - 1 No. g) Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade. MR
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
SUB HEAD - IV - (FIRE EXTINGUISHERS) Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm houter with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
YATRISHED Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : All kinds of soil D.S.R. Item No. 2.2.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil D.S.R. Item No. 2.28.1
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Brick work in foundation 1st class b/work in 1:4cement and coarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.4.1
Brick work in SUPER STRUCTURE in 115 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.12.1
12 mm thk plaster (1:4) with cement & Coarse Sand Ground Floor D.S.R. Item No. 13.4.1
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) D.S.R. Item No. 13.5.1
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. Item No. 13.80
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate D.S.R. Item No. 11.3.1
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). D.S.R. Item No. 13.46.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (make:Asian/Berger/Dulux) D.S.R. Item No. 13.48.1
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete D.S.R. Item No. 11.23.1
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating and chemical barrier under and around the columns pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit ete. Complete (Plinth area of the building at ground floor only shall be measured as per I.S.6313(part ii 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows. I- Treatment for masonry and foundatrion 5 litres per sqm II- Back fill in immediate contact with foundation 7.5 liters/sqm. III- Treatment of top surface of plinth filling 5 liters per sqm IV- Treatment junction of soil along extemal per meter building 7.50 litre/sqm. V- Treatment of soil under apron along extemal perimeter 5 Iiter/ sqm. DSR Item No. 2.35.3.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R 2021No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R. No.12.22.1
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X4.0 sqmm + 1x 4.0 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.TV antenna socket outlet
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required.
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Double Pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required Upto 35 sq. mm
Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia(Rate taken From Civil DSR 2021-18.12)
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 16 sqmm 3.5 core
Supply and erection of 1X10 W mirror light complete in all respects Make : Philips/Bajaj
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. Make : Philips/Bajaj
Providing & fixing Wall Bracket Light -3w
Providing & Fixing Wall Focus Ligh 7 Watt
CLOCK ROOM Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : All kinds of soil D.S.R. Item No. 2.2.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil D.S.R. Item No. 2.28.1
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Brick work in foundation 1st class b/work in 1:4cement and coarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.4.1
Brick work in SUPER STRUCTURE in 115 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. Ground Floor D.S.R. Item No. 6.12.1
12 mm thk plaster (1:4) with cement & Coarse Sand Ground Floor D.S.R. Item No. 13.4.1
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) D.S.R. Item No. 13.5.1
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. D.S.R. Item No. 13.80
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate D.S.R. Item No. 11.3.1
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). D.S.R. Item No. 13.46.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm D.S.R. Item No. 13.48.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length Second class teak wood D.S.R. Item No. 9.1.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws D.S.R. Item No. 9.21.1
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only D.S.R. Item No. 9.22.1
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete D.S.R. Item No. 11.23.1
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating and chemical barrier under and around the columns pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit ete. Complete (Plinth area of the building at ground floor only shall be measured as per I.S.6313(part ii 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows. I- Treatment for masonry and foundatrion 5 litres per sqm II- Back fill in immediate contact with foundation 7.5 liters/sqm. III- Treatment of top surface of plinth filling 5 liters per sqm IV- Treatment junction of soil along extemal per meter building 7.50 litre/sqm. V- Treatment of soil under apron along extemal perimeter 5 Iiter/ sqm. DSR Item No. 2.35.3.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R 2021No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R. No.12.22.1
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire
2X2.5 sqmm + 1x 2.5 sqmm earth wire
2X6.0 sqmm + 1x 6.0 sqmm earth wire make:Schneider/RR Kabel/Northwest
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm
Supplying and fixing brass batten/angle holder including connectionetc. as required.
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect.
EXTERNAL DEVELOPMENT Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : All kinds of soil D.S.R. Item No. 2.2.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). D.S.R. Item No. 16.2
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
Brick work in foundation 1st class b/work in 1:4cement and couarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 D.S.R. Item No. 16.78.1
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer D.S.R. Item No. 16.43.2
Providing & Fixing Designers Sand Stone Fountain (Pampa Sarovar) with All completeFitting.M.R.
Providing and fixing sculptures in cement concrete incl all fixtures as per design by local artisans and including golden/bronze andother painting As Per Market Rate
C.C. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
SUB-HEAD-II (HT CABLES ) Supply and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 300 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required. D.S.R. 2022 Electrical Item No. 10.1.4
Supply and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 300 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required. D.S.R. 2022 Electrical Item No. 10.2.4
SUBHEAD III-EARTHING AND LOOP EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. D.S.R. 2022 Electrical Item No. 5.2
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. D.S.R. 2022 Electrical Item No. 5.4
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required. D.S.R. 2022 Electrical Item No. 5.6
Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects. D.S.R. 2022 Electrical Item No. 6.14
Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects. P.W.D.SOR Electrical 2018 ITEM No. 718
Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respects. D.S.R. 2022 Electrical Item No. 5.15
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. D.S.R. 2022 Electrical Item No. 5.12
Supply and fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect. P.W.D. SOR Electrical 2018 ITEM No. 1421
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. D.S.R. 2022 Electrical Item No. 2.10.4
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch mtring instrument & instrument box with CTs etc. in case of TPN complete in all respect. 25 Amp SPN P.W.D. SOR Electrical 2018 ITEM No. 807 (b)
Supply and fixing of Bakelite sheet 3 mm thick of suitable size & connector N.S (P.S.)
SUBHEAD V-CABLES Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the make:Schneider/RR Kabel/Northwest 120 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(o)
50 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(l)
35 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(k)
25 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(j)
10 sqmm 4 core PWD SOR Electrical 2018 ITEM No. 501(h)
10 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 501(b)
6 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 501(a)
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire make:Schneider/RR Kabel/Northwest 120 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(o)
50 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(l)
35 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(k)
25 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(j)
10 sqmm 4 core PWD SOR Electrical 2018 ITEM No. 503(h)
10 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 503(b)
6 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 503(a)
Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. make:Schneider/RR Kabel/Northwest 120 sqmm PWD SOR Electrical 2018 ITEM No. . 504(j)
70 sqmm PWD SOR Electrical 2018 ITEM No. 504(h)
50 sqmm PWD SOR Electrical 2018 ITEM No. 504(g)
35 sqmm PWD SOR Electrical 2018 ITEM No. 504(f)
25 sqmm PWD SOR Electrical 2018 ITEM No. 504(e)
16 sqmm PWD SOR Electrical 2018 ITEM No. 504(d)
10 sqmm PWD SOR Electrical 2018 ITEM No. 504(c)
6 sqmm PWD SOR Electrical 2018 ITEM No. 504(b)
SUBHEAD IV-MAIN L. T. PANELS LT PANEL & FEEDER PILLAR Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. L.T. PANELS Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main LT Panel make:Schneider/RR Kabel/Northwest Incoming : One (1) No 200 Amp. 4P MCCB of 50KA Breaking capacity mtring : 1 Set of CT's one of 200/ 5Amp ratio for Multifunction mtr 1 Set of CT's one of 200/ 5Amp ratio 50/51 1 Set of CT's one of 200/ 5Amp ratio for APFC relay. One (1) Set of Phase Indication Lamp. One (1) Set of B+C Type SPD Bus Bar : One (1) No.300 Amp.TPN aluminimum bus bar of suitable length.50KA Outgoing : Phase indication lamps on nos outgoing to be provided. 02 No.125 Amp 4P MCCB. (25 KA) 01 No.100 Amp 4P MCCB. (25 KA) 03 No.63 Amp 4P MCCB. (25 KA) 04 No.10 Amp DP MCCB. (10 KA) Panel described as above N.S
SUBHEAD IV-MISCELLANEOUS Providing, Laying and Fixing following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 100mm dia DSR -2022 E/M Item No. 14.14.1
Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortaConstructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5r including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 900 mm x 1000 mm deep DSR 18.34.1
SUBHEAD VIII- SAFETY EQUIPMENTS Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. DSR -2022 E/M Item No. 2.21
Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. DSR -2022 E/M Item No. 2.22
Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. PWD SOR ELECTRICAL 2018 ITEM NO. 1133
Supplying & Laying of 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality PWD SOR ELECTRICAL 2018 ITEM NO. 1136
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & P for proper completion of work. PWD SOR ELECTRICAL 2018 ITEM NO. 1134
Supply and fixing of fire extinguishers, ABC Type 4.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. PWD SOR ELECTRICAL 2018 ITEM NO. 1131
Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. PWD SOR ELECTRICAL 2018 ITEM NO. 1132
ELECTRICAL WORKS SCHEDULE ITEMS (AS PER PWD SCHE. 2018/DSR 2018/2019) NON - SCHEDULED ITEMS (AS PER MARKET RATES ) SUBHEAD I- WIRING POINTS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. make:Schneider/RR Kabel/Northwest DSR ELECTRICAL 2022 ITEM NO. 1.3.1 (Group A)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required. make:Schneider/RR Kabel/Northwest DSR ELECTRICAL 2022 ITEM NO. 1.4
Same as item No.(1) but for 5 amp plug point with piano type switch and socket etc. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 141©
Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. Addition for light / fan points with modular type switch in place of piono type switch. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 187(A)
Addition for plug points with modular type switch in place of piono type switch. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 187(C)
Addition for Exhaust fan points with modular type switch in place of piono type switch. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 187(D)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. required for proper completion of the work as directed by Engineer I/C. make:Schneider/RR Kabel/Northwest 2X 1.5sq. mm + 1 X 1.5 sq. mm earth wire DSR 2022 (E/M) Item No. 1.14.1
2X4 sq. mm + 1 X 4 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.3
2X 6 sq. mm + 1 X 6 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.4
2X10 sq. mm + 1 X 6 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.5
2X10 sq. mm + 1 X 6 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.6
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.21.1 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.21.2 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.21.3 32 mm
SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Bajaj Philips DSR 2022 (E/M) Item No. 1.44
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Bajaj Philipes DSR 2022 (E/M) Item No. 1.50.1
Suuply and fixing of single LED light wall bracket on matching M.D.F.E.G board base etc. complete in all respect.(CAT: AAA) Make : Bajaj /Philips PWD SOR ELECTRICAL 2018 ITEM NO. 412
Suuply and fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA) Make: Bajaj /Philips PWD SOR ELECTRICAL 2018 ITEM NO. 1417
SUBHEAD III-DISTRIBUTION BOARD Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) make:Schneider/RR Kabel/Northwest 8 way , Double door DSR 2022 (E/M) 2.3.2
12 Way Double door DSR 2022 (E/M) 2.3.2
Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) make:Schneider/RR Kabel/Northwest 1002
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp. DSR 2022 (E/M) 2.13.2
40 Amp. DSR 2022 (E/M) 2.13.2
Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. make:Schneider/RR Kabel/Northwest 1139
Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work. make:Schneider/RR Kabel/Northwest 1139(A)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) 2.11
SUBHEAD IV-EARTHING Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required. DSR 2022 (E/M) 5.6
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm DSR 2022 (E/M) 5.9
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. DSR 2022 (E/M) 5.12
SUBHEAD V-MAIN L. T. PANELS PANEL (for type-Admin Building) Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. make:Schneider/RR Kabel/Northwest The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm mtr PANEL Incoming : One (1) No 100 Amp. 4P MCCB of 25KA Breaking capacity mtring : One (1) No. Sets Multifunction mtr nos incoming One (1) No. of Phase Indication Lamp nos incoming Bus Bar : One (1) No. 150 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. 01 No.63 Amp 4P MCB. (10 KA) 19 No.63 Amp DP MCB. (10 KA) 02 No.40 Amp DP MCB. (10 KA) Panel described as above. N.S
SUBHEAD V-MAIN L. T. PANELS PANEL (for Residence Building) Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. make:Schneider/RR Kabel/Northwest The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm mtr PANEL Incoming : One (1) No 100 Amp. 4P MCCB of 25KA Breaking capacity mtring : One (1) No. Sets Multifunction mtr nos incoming One (1) No. of Phase Indication Lamp nos incoming Bus Bar : One (1) No. 150 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. Phase indication lamps on nos outgoing to be provided. 01 No.63 Amp 4P MCB. (10 KA) 07 No.63 Amp DP MCB. (10 KA) 02 No.40 Amp DP MCB. (10 KA) Panel described as above. N.S
FAN & LIGHTS Supply of 80W drop down pole mounted type LED decorartive light fixture with system efficacy of min. 110 lm/W, CCT 3000K, IP 66 & IK 08, Spun aluminum powder coated housing with casted aluminum heat sink, Optical grade injection moulded polycarbonate diffuser with in-built Surge protection of 6kV and External Surge protection of 10kV. Including with 1. Supply of 8 mtr high hot dip galvanised octagonal poles with 130mm bottom A/F & 70mm top A/F made up of 3mm thk. HR sheet alongwith base plate of size 200X200X16mm thk. (Without bracket, foundation bolt, Bakellite sheet) with PU Paint 2. Supply of 1000mm long hot dip galvanised standard type double arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70mm A/F. with PU paint 3. Supply of 4Nos of M20X600 long 'J' type EN 8 grade foundation bolts along with template 4. Supply of BAKELITE SHEET OF SIZE 275X75X4MM THK WITH STUD TERMINALS & 2 NO. 6A SP MCB. MODEL NO. EPC-SL-24-8M-DECO-OP-GAD-001 Make: Bajaj
Providing & Fixing Spike Light with all complete Fitting. (SPYKZ BGSBL 9W LED WW) LED Spike/ Bush light with die-cast aluminium housing designed for rugged outdoor usage & IP65 protection.
Providing & Fixing Wall Focus Light AMAZE (BJFL 50W LED I) A resilient floodlight with toughened glass, aluminum housing, IP66 protection. Experience superior lighting for industrial and commercial settings.
Providing & fixing Wall Bracket Light FAÇADE -6434-3w
P/F 15W Leaser Cut LED Bollard light with name/logo engraved at the Top_900MM
P/F 4M Tringa Column light with remote control TRI-Colour Light Column-4M BLSLC 50W LED TRI 4
P/F 30W AIO LED Solar street light(Hybrid) with 5M octagonal pole Model No. 30W-SOLAR BSZSL 30W LED HYB-STANDARD HYBRID
Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-38 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect.
Plantation of Trees, Ground Clearing, Excavation of upto 1 feet and refilling with soil of 1.5 feet depth (compacted),Disposal of excavated material from site, Laying irrigation pipelines, adding organic soil enhancers as per approved list including providing and planting of hedges as per approved list ensuring bamboo support for saplings, laying mulching materials, logistics and transport for daily watering of plantation, daily maintenance and watering for 3 years, ensuring maintenance of water tanks and pipelines, de-weeding on quarterly basis, preparing Monitoring Reports, submitting Monitoring Reports, Maintenance of all the trees, plants, shrubs, hedges, lawns and flower bed preparation by uprooting the old plants for sowing planting of new seedlings (seasonal and perennial both) and different types of cutting including earth work, spreading and mixing of manure and fertilizers and levelling and bund making etc. To prepare and maintain flowers and plant pots with flowers and plants both indoor and outdoor at designated places to be decided in consultation with the designated officer. This job also includes regular watering of grass, lawns, trees, shrubs, plants etc. Spraying of insecticides, pesticides, weedicides on the plants as and when required, removing the waste to the proper place. Intercultural operation and maintenance of the plants both in flower beds and pots including preparation of soil mixture (manure, soil, fertilizers), weeding, liming, manuring, filling of pots with soil mixture, cutting of hedges, grass cutting in lawn and lifting the grass to the compost pit. Any other job which is required to make the campus from Horticulture point of view beautiful with lush green Lawns. This rate includes necessary tools and equipments etc.
Supply & plantation of Trees upto 8ft to 10ft height well settled, all indigenous varieties (local) as per listed below, location and quantities shall be as per drawing Mangifera Indica (Mango), Bacopa Monnieri (Brahmi), Terminalia Tomentosa (Asna), Azadirachta Indica (Neem) & Bambusa Bambos (Baans) Terminalia Arjuna (Arjun), Tectoria Grandis (Sagaun), Shorea Robusta (Saal), Stereospermum Tetragonum (Padal), Anogeissus Latifolia (Bakli), Madhuca Longifolia (Mahua) & Diospyros Malabarica (Gaub) Saraca asoca (ashok), Ficus religiosa (peepal), Ficus benghalensis (bargad), Aegle marmelos (bel) & Phyllanthus emblica (aonla) Pterocarpus Santalinus (rakta chandan), Butea monosperma (dhaak), Artocarpus altilis (kathal) & Santalum album (chandan) Saraca Asoka (Sita Ashok), True Cinnamon (Nag Kesar), Mangolia Champaca (Champa) & Mimusops Elengi (Maulsari) Saussurea Ggossypiphora (Mratyusanjeevani), Azadirachta Indiac (Neem) & Adiantum Venustum (Hansraj)
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area. (two application) i/c cost of chemical) and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 2.33 (dsr hort. 2020)
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 2.13 (dsr hort. 2020)
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). 2.25 (dsr hort. 2020)
Providing and stacking of plant Mogra of height 25 to 30 cm., 2 to 3 branch in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. 4.88 (dsr hort. 2020)
Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge. 4.91 (dsr hort. 2020)
Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 5.13 (dsr hort. 2020)
Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge. 5.17 (dsr hort. 2020)
Providing and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy ,in 35 cm Cement Pot as per direction of the officer-in-charge. 5.28 (dsr hort. 2020)
Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.1 (dsr hort. 2020)
Providing and stacking of Asparagus marrie, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.3 (dsr hort. 2020)
Providing and stacking of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.10 (dsr hort. 2020)
Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.14 (dsr hort. 2020)
Providing and stacking of Ophiopogon jaburan (variegated) ,full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 6.21 (dsr hort. 2020)
Providing and stacking of Alstonia scholaris of height 150-165 cm. in bagof size 25 cm as per direction of the officer-in-charge. 7.4 (dsr hort. 2020)
Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.8 (dsr hort. 2020)
Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.13 (dsr hort. 2020)
Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.17 (dsr hort. 2020)
Providing and stacking of lotus flower of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. Mr
Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.2 (dsr hort. 2020)
Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 8.7 (dsr hort. 2020)
Providing and stacking of Cassia laevigata of height 45-60 cm. in earthenpots of size 20 cm as per direction of the officer-in-charge. 8.11 (dsr hort. 2020)
Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.14 (dsr hort. 2020)
Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 8.54 (dsr hort. 2020)
Providing and stacking of Allamanda violacea of height 30 cm to 45 cm. in poly bag of size 20 cm as per direction of the officer-in-charge. 9.2 (dsr hort. 2020)
Providing and stacking of Clerodendrum thomsoniae of height 30 cm.to 45 cm in 20 cm size of poly bag & as per direction of the officer-in-charge. 9.6 (dsr hort. 2020)
Providing and stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 9.14 (dsr hort. 2020)
Providing and Stacking of Anjeer of height 75-90 cm. in poly bagsof size 25 cm as perdirection of the officer-in-charge. 11.1 (dsr hort. 2020)
Providing and Stacking of Satavari, well developed in earthen pot of size 20 cm as per direction of theofficer-in-charge. 11.6 (dsr hort. 2020)
Providing and Stacking of Sarpgandha well developed in poly bag of size 20 cm as per direction of theofficer-in-charge. 11.14 (dsr hort. 2020)
Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 11.17 (dsr hort. 2020)
Providing and Stacking of Aprajita White well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 11.18 (dsr hort. 2020)
IRRIGATION SYSTEM DRIP IRRIGATION SYSTEM FOR PLANTATION - A SYSTEM HEAD UNIT SNAD FILTER + BACKWASH ASSLY 2.5"
SCREEN FILTER 2.5"
ASSLY FOR FILTER 2.5"
PRESSURE GAUGE + STOP COCK
NETWORK - FINOLEX HDPE & PVC PIPES HDPE PIPE 75 MM PN4 (TANK TO PLOT)
PVC PIPE 75 MM 4KG/CM2
PVC PIPE 63 MM 4KG/CM2
EMITTING SYSTEM FINOGOL PLAIN LATERAL 16 MM
DRIPPER 8 LPH
START TO END SET FOR DRIP LINE 16 MM
BARBED COUPLER 16 MM
TEE 16 MM
ELBOW 16 MM
ELBOW 16 MM
BALL VALVE 63 MM
FLUSH VALVE 63 MM
VALVE BOX 12"
Pump: Crompton Greaves 10.00 Hp pump with necessary accessories.(Market Rate)
Providing and fixing H.D.P. container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destinatin hoisting and fixing of accessories such as inlet,outlet over flow of all tanks capacity above 1000 to 20,000 litres
TRANSFORMER EXTERNAL ELECTRICAL WORKS SCHEDULE ITEMS (AS PER P.W.D. SOR Item No. 2022 SCHE. 2018/DSR 2018) NON - SCHEDULED ITEMS (AS PER MARKET RATES ) SUB-HEAD-I (SUBSTATION EQUIPMENTS) TRANSFORMER 100KVA 11KV/433V Dyn11 Copper Wound Oil Type Transformer with OCTC +5% to -10% in steps of 2.5% , Class of Insulation: A, Temperature rise limits of 40 deg.C over ambient of 50 degrees. Losses (As per IS tolerances) No load losses -2.7kW, Full load losses - 7.7kW and all accessories and confirming to As per IS 1180 Level 2 & Testing paramtr as per IS 2026 complete with all fittings and accessories as per specifications attached etc as required at site. N.S. (P.S.)
CCTV CAMERA SYSTEM Supply, , Installation Testing and Commissioning of 4 MP IP, 5 inch PTZ camera with 32*Zoom & 150 Meter IR with SD card supported. IP 67, Focal length 4.5 to 153mm, Frame rate max. 25/30fps, max. resolution 2560*1440 & Image Sensor 1/2.5'' progressive scan CMOS. (MR)
Supply, , Installation Testing and Commissioning of IP Bullet Camera IR type with the following specification Minimum 2.0 MP resolution, IP 67, 0.2 lux at F 1.2, 1/3" DIS, 3.6mm fixed iris lens. (MR)
PVC junctin IP rating 65 suitable for CCTV camera work.
Supply, laying and testing of unshielded twisted pair CAT 6 network cable confirming to TIA/EIA standards, in heavy class FRLS PVC pipes / conduits, rate shall include necessary accessories all complete as required. Cost to include dressing the cable with proper accessories, proper addressing of cables using ferrules. labelling and end to end signal continuity testing for all ports. The wires shall be of different colours as required. (MR)
Supply, fixing, tesing & commissioning of CAT - 6, 8 position, 8 wire, network RJ 45 Connectors including crimping, testing end to end connectivity and necessary acessories all complete as required.
Supply, fixing, tesing & commissioning of RJ 45 In line Coupler Ethernet Network Cable Extender Connector including testing end to end connectivity and necessary acessories all complete as required. (MR)
Patch Panel Supply, installation, tesing & commissioning of 24 Port loaded patch panel CAT6 (1U with rear wire manager) silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections
PUBLIC ADDRESS SYSTEM PULZ CS5FR SPEAKER SYSTEM
BRACKET OF CS5FR
PULZ AD4820 4 CHANNEL POWER AMPLIFIER
PULZ DSS88 SPEAKER MANAGEMENT SYSTEM
PULZ XO23 CROSSOVER
32 U EQUIPMENT RACK
RACK CABLES AND CONNECTORS FOR SPEAKERS
2.5sqmm armoured speaker cable
4 sqmm armoured speaker cable
Interconnects
Installation, Testing & Commissioning.
Supply, Installation Testing and Commissioning of 32 channel Network Video Recorder (NVR) with TCP IP, RS 232, RS 485 Connectivity capable of handling Up to 5 MP cameras, 4k HD, 30 FPS and shall be ONVIF compatible. The NVR shall be suitable for connecting multiple HDD (SATA / eSATA) of 8 TB capacity. The NVR shall have provision for multiple HDMI / VGA simultaneous output and also audio output. The cost to include setting up, commissioning of system all complete as required (ANNEXURE-A3)
GIGA byte switch 24 port.
Supply, and Installation of following capacity Hard disk drives for storing the recorded data - 8TB (ANNEXURE -A2)
Supply, Installation, Testing and Commissioning of LCD / LED monitor capable of displaying the output of the CCTV system in the location specified at site- 31.5 inches TV with KVM splitter & HDMI cable. (ANNEXURE-A1 ATTACHED)
Network Rack Supply, installation, tesing & commissioning of 6U rack with glass fronted door, lockable arrangement along with power bus, ventilation fans including necessary fixing accessories all complete as required
Supply, fixing and checking connectivity of Patch cords (1m) CAT6 (RJ45 with moulded boots) at switch end
Supply , fixing and checking connectivity of Patch cords (1m) CAT6 (RJ 45 with moulded boots) at user end
Poviding & Fixing Designer dust bin
Providing & Fixing of Stainless Steel Racks
M/S DREAM CONSTRUCTION (BID ID -5229146)
M/S SHAKTI CONSTRUCTION (BID ID -5229346)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid