GEMC-511687786183304
Awarded to E FOCUS INSTRUMENTS INDIA PRIVATE LIMITED
₹1.1 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 5KV Insulation Resistance Meter - Portable | UNI-T - UT513A | - | 2 NOS | ₹53,500 | 107,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LQualified Make: UNI-T
Model: UNI-T - UT513A 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: UNI-T
Model: UNI-T - UT513A | L1 | Qualified | |
| 2 | L2₹1.5 L+₹39,000 (36.4%)Qualified Make: Sonel
Model: SONEL & MIC2510 204 CONVERGENT TECHNOLOGIES 2ND MAIN MAHALAKSHMI LAYOUT BANGALORE KARNATAKA 560086 | BENGALURU URBAN | KARNATAKA | 560086 | Make: Sonel
Model: SONEL & MIC2510 | L2 | Qualified | |
| 3 | L3₹1.5 L+₹46,398 (43.4%)Qualified Make: Metrel
Model: METREL & MI3121H CHENNAI TAMILNADU 600041 | CHENNAI | TAMIL NADU | 600041 | Make: Metrel
Model: METREL & MI3121H | L3 | Qualified | |
| 4 | Disqualified Make: MECO
Model: MECO DIT918 NARESH RADIO CO NARESH RADIO CO RAM MANDIR LANE NEAR RAILWAY GATE NO 2 LAKHTOKIA GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | Make: MECO
Model: MECO DIT918 | - | Disqualified | |
| 5 | Disqualified Make: Metrel
Model: Metrel MI 3121H FLAT NO 4 ANANDNIWAS APARTMENT I F PANCHSHIL APT SHREE SADGURU NAGAR MARG GOVIND NAGAR NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | Make: Metrel
Model: Metrel MI 3121H | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Oct 2018, 7:00 pmClosed
insulation tester Insulation Tester ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values PERFORMANCE Type Portable Hand Held
Portable Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
200 K Ohm to 1 T Ohm Measurement Accuracy 2 2
4
8 Measurement Resolution 0.01 0.01
0.1
1 Test Voltage 2500 50
100
250
500
1000
2500
5000 Test Current 1 1
2 OTHER MEASUREMENT AC/DC Voltage Measurement (Volt) 600 * AC/DC Voltage Measurement Resolution ( Volts ) 0.1 * AC/DC Voltage Measurement Accuracy (%) 2.0 * 1/4 FEATURES Pass Fail Function true * Data Logging More than 99 locations * PC interface along with suitable & driven software Available * Live Circuit Detection inhibit test terminal voltage >30 V prior to initialization of test * Auto Discharge Time (Second) Less than 0.5 * Any Other Features Measuring range up to 100 GΩ with test voltage from 100 to 2500 V. Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) calculation. Measuring results are displayed in numeric and analogue representation. Guard test terminal for elimination of potential surface leakage currents. Automatic polarity reversal on continuity test. Large green and red lights of the LEDs for PASS FAIL evaluation of test result. Suited for testing on CAT IV installations. Magnetic holder for fixing instrument on metal surfaces. Built-in battery charger. Two level memory structure for saving test results and parameters. Download of results via RS232 or USB cable directly to the PC with the help of the PC software EuroLink PRO. * GENERIC Dimensions ( mm x mm x mm ) 140 x 80 x 230 mm * Weight 850 * SAFETY Safety rating Category III 600 V of IEC 61010 Category III 600 V of IEC 61010
Category III 1000 V of IEC 61010 POWER REQUIREMENT Power Requirements Battery Operated * 2/4 Type of Battery Rechargeable * if rechargeable
then chemistry of the battery Ni-MH * if Non-rechargeable
then size of the battery cell NA * Number of non- rechargeable the battery/cell NA * Voltage of rechargeable Battery 15 * Capacity of rechargeable battery (milli ampere hour) 3500 * ACCESSORIES Standard Accessories Supplied with the Equipment Soft hand strap Test lead
2 x 1.5 m Test probe
2 pcs (black
red) Crocodile clip
red) Power supply adapter + 6 NiMH rechargeable batteries
type AA Instruction manual on CD Short instruction manual Handbook on CD Calibration certificate * WARRANTY Warranty 1 1
2
3 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Temperature 40 * Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hours each true * 3/4 at a temp of 40 degree C & 95% RH Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test MI3121H 27-02-2012 * Name and address of the Lab for the specification test Metrel DD Slovenia Europe ILAC * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Biswajit Sahu 530008
Asst. Material Manager
Wagon cum General Stores Depot
Near DLS Colony
Kancharapalem
E.Co.Railway
Visakhapatnam-530008 2 15
740524
GEM/2018/B/104317
GeM Contract
insulation tester
GeM Contract
15 days
Andhra Pradesh; Visakhapatanam
PRODUCT
Awarded to E FOCUS INSTRUMENTS INDIA PRIVATE LIMITED
₹1.1 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 5KV Insulation Resistance Meter - Portable | UNI-T - UT513A | - | 2 NOS | ₹53,500 | 107,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| insulation tester Insulation Tester ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values PERFORMANCE Type Portable Hand Held | - | - | - |
| Portable Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm | - | - | - |
| 200 K Ohm to 1 T Ohm Measurement Accuracy 2 2 | - | - | - |
| 4 | - | - | - |
| 8 Measurement Resolution 0.01 0.01 | - | - | - |
| 0.1 | - | - | - |
| 1 Test Voltage 2500 50 | - | - | - |
| 100 | - | - | - |
| 250 | - | - | - |
| 500 | - | - | - |
| 1000 | - | - | - |
| 2500 | - | - | - |
| 5000 Test Current 1 1 | - | - | - |
| 2 OTHER MEASUREMENT AC/DC Voltage Measurement (Volt) 600 * AC/DC Voltage Measurement Resolution ( Volts ) 0.1 * AC/DC Voltage Measurement Accuracy (%) 2.0 * 1/4 FEATURES Pass Fail Function true * Data Logging More than 99 locations * PC interface along with suitable & driven software Available * Live Circuit Detection inhibit test terminal voltage >30 V prior to initialization of test * Auto Discharge Time (Second) Less than 0.5 * Any Other Features Measuring range up to 100 GΩ with test voltage from 100 to 2500 V. Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) calculation. Measuring results are displayed in numeric and analogue representation. Guard test terminal for elimination of potential surface leakage currents. Automatic polarity reversal on continuity test. Large green and red lights of the LEDs for PASS FAIL evaluation of test result. Suited for testing on CAT IV installations. Magnetic holder for fixing instrument on metal surfaces. Built-in battery charger. Two level memory structure for saving test results and parameters. Download of results via RS232 or USB cable directly to the PC with the help of the PC software EuroLink PRO. * GENERIC Dimensions ( mm x mm x mm ) 140 x 80 x 230 mm * Weight 850 * SAFETY Safety rating Category III 600 V of IEC 61010 Category III 600 V of IEC 61010 | - | - | - |
| Category III 1000 V of IEC 61010 POWER REQUIREMENT Power Requirements Battery Operated * 2/4 Type of Battery Rechargeable * if rechargeable | - | - | - |
| then chemistry of the battery Ni-MH * if Non-rechargeable | - | - | - |
| then size of the battery cell NA * Number of non- rechargeable the battery/cell NA * Voltage of rechargeable Battery 15 * Capacity of rechargeable battery (milli ampere hour) 3500 * ACCESSORIES Standard Accessories Supplied with the Equipment Soft hand strap Test lead | - | - | - |
| 2 x 1.5 m Test probe | - | - | - |
| 2 pcs (black | - | - | - |
| red) Crocodile clip | - | - | - |
| red) Power supply adapter + 6 NiMH rechargeable batteries | - | - | - |
| type AA Instruction manual on CD Short instruction manual Handbook on CD Calibration certificate * WARRANTY Warranty 1 1 | - | - | - |
| 2 | - | - | - |
| 3 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Temperature 40 * Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hours each true * 3/4 at a temp of 40 degree C & 95% RH Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test MI3121H 27-02-2012 * Name and address of the Lab for the specification test Metrel DD Slovenia Europe ILAC * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Biswajit Sahu 530008 | - | - | - |
| Asst. Material Manager | - | - | - |
| Wagon cum General Stores Depot | - | - | - |
| Near DLS Colony | - | - | - |
| Kancharapalem | - | - | - |
| E.Co.Railway | - | - | - |
| Visakhapatnam-530008 2 15 | - | - | - |
Exempted
1 Nov 2018
13 Oct 2018
contract_GEMC-511687786183304.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_740524.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .