Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.6 Cr
EMD Value
₹50,000
Closing Date
22 Jan 2026, 3:00 pmClosed
Director SRI
STATE REFERRAL INSTITUTE FOR WATER QUALITY, NETTOOR, KOCHI
State Plan 2024 25 Construction of LAB for testing Pesticides and Heavy metals at Kizhakkumpattukara Quality control District lab Thrissur General Civil Work
2026_KWA_827948_1
07/2025-26/ SRI/NTR
Open Tender
Civil Works - Others
Item Rate
540 days
Kizhakumpattukkara Thrissur
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,515
Yes
₹50,000
Yes
25 May 2026
15 Jan 2026
23 Jan 2026
15 Jan 2026
22 Jan 2026
15 Jan 2026
15 Jan 2026 - 22 Jan 2026
Construction of Lab for testing Pesticides & Heavy metals
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
5.33.1.2:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work upto plinth levelConcrete of M30 grade with minimum cement content of 350 kg /cum
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.33.1.1:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum
5.33.2.1:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
10.6.3:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover
OD256435/2024-2025:Supplying and fixing 20mm thick readymade PVC door 80x210cm with frame including conveyance ,cost of fitting labour for fixing etc
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.37.1:White washing with lime to give an even shade:New work (three or more coats)
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.51.1:Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:One coat
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
OD256440/2024-2025:Providing and laying Ceramic anti skid floor tiles in different sizes 600x600 mm (thickness to be specified by the manufacturer) of first quality conforming to IS : 15622, of approved make, in colours such as white,ivory,grey,fume red brown laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
11.53:Providing and fixing Glass mossaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in-charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-charge.
OD256436/2024-2025:supplying and fixing PRESSED STEEL WINDOW AMD VENTILATORS of standard pattern with frames as per profile of section 82x62mm embosed sheet shutter 50x20mm,special channel (reverse and beading) shutter 12mm dia rod 25x5mm flat with 75mm ss hinges 50mm hook , 125mm ss stay and handle for windows with section 105x60mm using 18g(1.2mm thick CRCA) sheet and shutter made of section 75x30cm made of section 75x30cm for outer styles and horizontel members and then insert with and enclosed with stiff and sheet 26cr with zincromatr primer(glass work extra tobe measured)
OD256438/2024-2025:supplying and fixing PRESSED STEEL FLUSH DOOR-double shutter of standard pattern with frame as per profile of is:4351 of section 105*60mm using 18g(1.2mm thick CRCA) sheet and shutter made of section 75*30cm of outer style and horizondal member and then inserted with enclosed and stiffened sheet 26cr as per the specification with zinc cromate yellow primer included all charges of fittings coveyance etc,complete
OD256439/2024-2025:supplying and fixing a ready-made ferrocement waste pit(0.90m dia,60cm height with cover slab, including conveyance , fixing charges etc. complete
50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
50.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
50.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.9.6.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2
50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
50.18.9.16.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
18.57.2:Providing and fixing PTMT, push cock of approved quality and colour.15 mm nominal bore, 80 mm long weighing not less than 46 gms
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
13.71:Lettering with black Japan pint of approved brand and manufacture
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
5.16:Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 ( 1 cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.9.4:Centering and shuttering including strutting, etc. and removal of form for:Shelves (Cast in situ)
OD256437/2024-2025:supplying and fixing granite name board granite including lettering , fixing etc complete
17.11.2:Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm
17.7.1:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
11.20.1:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement
50.9.12.1:Providing and fixing Thomson Multi wood board or equivalent make, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately) as per the direction of site Engineer-in-charge.
13.18:Neat cement punning
OD71692/2025-2026:Engaging coolie for various activities for work
OD233031/2025-2026:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, for finishing the walls over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm
Supplying and fixing Wall bench ,L shape bench and Peninsular bench with wall cabinet and all accessories
OD61462/2025-2026:WALL BENCH - 5660 mm 1 No 18GRT90BS 5.7 rm 18 (±1)mm thick granite worktop 900 mm wide with backsplash CA100VLL 1 no u/b storage cabinet with 1 adjustable shelf & 2 doors 1000mm wide with lock CB100VLL 2 no u/b cabinet with 2 drawer, 1 adj. shelf and 2 doors 1000mm wide with lock CBGRT 1 no cable gromet CCH040-40 1 no ceiling mounted canopy hood 400x400 with vsb14 DATA 1 no single computer data outlet DATAPB 4 no single computer data pedestal F+B VFRAME 5.6 rm front+back frame FS75LV 3 no side frames FS90LVSP1 4 no side frames,special KS1000-H 2.4 rm knee space panel LE2SC-IN 1 no 16 Amp/220 Volt double electrical outlet LE2WP-IN 4 no 16 Amp/220 Volt double electrical pedestal box
OD61465/2025-2026:L SHAPE BENCH - 2500+1550+1150 mm 1 No 18GRT110BS 1.2 rm 18 (±1)mm thick granite worktop 1100 mm wide with backsplash 18GRT110 2.5 rm 19 (±1)mm thick granite worktop 1100 mm wide 18GRTCOR155SP 1 no 18 (±1)mm thick 1550mm wide granite corner worktop,special CA040VLL 1 no u/b storage cabinet with 1 adjustable shelf & 1 door 400mm wide with lock CA050VLL 1 no u/b storage cabinet with 1 adjustable shelf & 1 door 500mm wide with lock CB050VLL 2 no u/b cabinet with 1 drawer,1adjustable shelf & 1 door 500mm wide with lock CBGRT 1 no cable gromet DATA 4 no single computer data outlet DATAPB 1 no single computer data pedestal F+B VFRAME 4 rm front+back frame FP-H 6.2 rm Filler panel FS110LVSP 10 no side frames,special FS150LVSP 2 no side frames,special KS1000-H 1.9 rm knee space panel LE2SC-IN 4 no 16 Amp/220 Volt double electrical outlet LE2WP-IN 1 no 16 Amp/220 Volt double electrical pedestal box
OD61467/2025-2026:PENINSULAR BENCH - 2500 mm 1 No 18GRT90 2.5 rm 18 (±1)mm thick granite worktop 900 mm wide CA045VLL 1 no u/b storage cabinet with 1 adjustable shelf & 1 door 450mm wide with lock CB045VLL 1 no u/b cabinet with 1 drawer,1adjustable shelf & 1 door 450mm wide with lock CBGRT 1 no cable gromet DATA 4 no single computer data outlet F+B VFRAME 2.4 rm front+back frame FP-H 2.7 rm Filler panel FS75LV 2 no side frames FS90LVSP 3 no side frames,special KS1000-H 1.4 rm knee space panel LE2SC-IN 4 no 16 Amp/220 Volt double electrical outlet
Electrical works for building
OD56231/2025-2026: 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
OD56232/2025-2026: 90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp
OD56233/2025-2026: 90.11.1.12 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43)
OD56837/2025-2026:90.12..41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp
OD75084/2025-2026: 90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)
OD75086/2025-2026:90.11.1.14 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD75117/2025-2026: 90.11.1.19 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD75131/2025-2026: 90.12.1.43 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4 core 35 sq mm
OD75162/2025-2026: 90.15.4.1 Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD75182/2025-2026: 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG)
OD75184/2025-2026: 90.16.2.1 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required. 15.mm dia. G.I pipe ( medium class)
OD75196/2025-2026: 90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
OD75197/2025-2026: 90.16.5.2 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 2.65 mm (12 SWG)
OD75199/2025-2026: 90.17.8.3 Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40 mm
OD75204/2025-2026: 90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture
OD75211/2025-2026: 90.3.21.3 Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. 1200 mm 1X20W LED Lamp with box type fixture
OD75214/2025-2026: 90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
OD75215/2025-2026: 90.4.2 Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
OD75213/2025-2026: 90.3.18.1 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. 25 mm dia with HG company fabricated clamps
OD75216/2025-2026: 90.4.5.4 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD75217/2025-2026: 90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD75218/2025-2026: 90.4.9 Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
OD75219/2025-2026: 90.10.12 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 2 module moulded plastic box on surface
OD75220/2025-2026:90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
OD75222/2025-2026: 90.14.3.1 Supply and providing heavy duty 'A' section neoprene gasket in the panel board A' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
OD75223/2025-2026: 90.14.4 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
OD75221/2025-2026: 90.14.2.1 Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
OD75224/2025-2026: 90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD75225/2025-2026: 90.14. 6Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
OD75226/2025-2026: 90.14.7 Supply and providing copper earth bus in the panel board
OD75227/2025-2026:90.14.10.3 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
OD75311/2025-2026:90.14.11.13 MCCB Accessories Supply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
OD75313/2025-2026:90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator
OD75318/2025-2026:90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A 3pin Shuttered socket
OD76387/2025-2026: 90.15.4.5 Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD76392/2025-2026: 90.15.4.2 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD76402/2025-2026:90.4.10 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
OD56838/2025-2026:9.01.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
OD56824/2025-2026:2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD56825/2025-2026:2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD56826/2025-2026:2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD56835/2025-2026:2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD56836/2025-2026:2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
OD65764/2025-2026:2.1.2 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp TP & N
OD76327/2025-2026:2.14.3 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD75609/2025-2026:2.2.14 Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 Amp, 36 KA
OD56840/2025-2026:1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD56841/2025-2026:1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
OD56842/2025-2026:1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
OD56843/2025-2026:1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
OD56844/2025-2026:1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
OD56845/2025-2026: 1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
OD67462/2025-2026:1.21.2 supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required .25 mm.
OD67576/2025-2026:1.21.1 supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required .20 mm.
OD68013/2025-2026:1.7.7 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
OD68012/2025-2026:1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
OD68014/2025-2026:1.4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
OD68015/2025-2026:1.1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
OD75330/2025-2026:1.43 Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
OD75366/2025-2026:1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD75371/2025-2026:1.48 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
OD75385/2025-2026:1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
OD75392/2025-2026:1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
OD75425/2025-2026:1.27.3 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)
OD75426/2025-2026:1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
OD75427/2025-2026:1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
OD75446/2025-2026:1.27.5 supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)
OD75456/2025-2026:1.28.1 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
OD75477/2025-2026:1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
OD75533/2025-2026:1.14.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
OD76069/2025-2026:1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm
OD76070/2025-2026:1.17.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 2.5 sq. mm
OD76071/2025-2026:1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
OD76072/2025-2026:1.17.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 9 x 1.5 sq. mm
OD76073/2025-2026:1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm
OD76074/2025-2026:1.17.5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 X 1.5 Sq. mm
OD76075/2025-2026:1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm
OD76381/2025-2026:1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
OD76437/2025-2026:1.14.8 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
OD76439/2025-2026:1.17.24 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 4 sq. mm
OD76441/2025-2026:1.14.10 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
OD65758/2025-2026:5.3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
OD68011/2025-2026:3.7.3 Supplying, installing, testing and commissioning of following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections,
OD68010/2025-2026:4.2.4Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6mm thickness
OD66428/2025-2026:supplying and fixing following modular switch /socket on the existing modular plate &amp ;amp;switch box including connection but excluding modular plate etc.as required .32 A,one way modular switch
OD66430/2025-2026: supply and fixing following size/ modules ,PVC box along with modular base and cover plate for modular switches in recess etc. as required .modular PVC box with cover plate for 12 module
OD66431/2025-2026: supply and fixing following size/ modules ,PVC box along with modular base and cover plate for modular switches in recess etc. as required .modular PVC box with cover plate for 8 module
OD66854/2025-2026:supplying and fixing of earth bench terminal strip
OD66856/2025-2026:supplying and wiring with 1.00/1.5 sq mm PVC insulated standard single core copper wires in the existing surfaces /recess conduits as required including giving necessary connections.
OD66857/2025-2026:supplying and wiring with 6.00 sq mm PVC insulated standard single core copper wires in the existing surface /recess conduits as required including giving necessary connections.
OD66858/2025-2026:supply and fixing following size/modules ,PVC box along with modular base and cover plate for modular switches in recess etc. as required .modular PVC box with cover plate for 4 module data derived from DSR E &M2016 1.27
OD66859/2025-2026:supply and fixing following size/modules, PVC box along with modular base and cover plate for modular switches in recess etc. as required .modular PVC box with cover plate for 6 module data derived from DSR E &M 2016 1.27
OD67445/2025-2026:supply and fixing 3 pin,5 A ceiling rose on the existing junction box /wooden block including connection etc.as required.
OD67570/2025-2026:submission of application for getting power/load enhancement from KSEB as per the direction of Departmental officers including the cost of application form to be remitted to KSEB
OD67571/2025-2026:supply and fixing 1 no metal box with 1 no white front plate on 1 nos 20/25 A modular type DP switch with indicator and 25 A shuttered socket, earthing make good the damages color washing etc. as required on recess the power plug (ROHS)
OD67573/2025-2026:supplying and fixing 20 A ,415 V, TPN industrial type socket outlet,with 4 pole and earth metal enclosed plug top along with 20 A &quot ;c quot;curve in sheet steel enclosure, on surface or in recess with chained metal cover for the socket out let and complete with connection testing and commissioning etc.as required.
OD67574/2025-2026:supplying and fixing following modular switch/socket on the existing modular plate &amp ;switch box including connections but excluding modular plate etc.as required.3 pin 5/6 A socket outlet
OD67575/2025-2026:supplying and fixing following modular switch/socket on the existing modular plate &amp ;switch box including connections but excluding modular plate etc.as required 5/6 A,one way modular switch
OD67577/2025-2026:supply and fixing LED tube (20 w). including wire , holder
OD67578/2025-2026:supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc.as required .3.15 mm (10 SWG)
OD67579/2025-2026:2.15.2 supply and fixing following rating,four pole 415 volts residual current circuit breaker (RCCB), having a sensitivity current upto 300 milli amperes in the existing MCB DB complete with connections testing and commissioning etc. as required .63 amps RCCB 4 pole 30ma
OD67580/2025-2026:supplying and fixing of following ways surface /recess mounting vertical type 415 V,TPN MCB distribution board of sheet steel,dust protected duly powder painted inclusive of 200A tinned copper bus bar common neutral link,earth bar ,din bar for mounting MCBs are required.
OD67581/2025-2026:2022 -Data analysis 2.15.2 supply and fixing following rating, four pole ,(three phase and neutral ) 415 volts residual current circuit breaker (RCCB) having a sensitivity current up to 300 milli amperes in the existing MCB DB complete with connections,testing and commissioning etc.as required .40amps RCCB 2 pole 30ma
OD67582/2025-2026:supply and fixing modular blanking plate on the existing modular plate &amp ;switch box excluding modular plate as required
OD67583/2025-2026:supplying and wiring with 2.500 sq mm PVC insulated standard single core copper wire in the existing surfaces/recess conduits as required including giving necessary connections
OD67584/2025-2026:supplying and wiring with 4.00 sq mm PVC insulated standard 4 core copper cable in the existing surfaces/recess conduits as required including giving necessary connections
OD75353/2025-2026:supplying and fixing 9 W LED Bulb in the existing batten holder has required .
OD75354/2025-2026: Supply conveyance ,installation ,testing and commissioning of 1800 lumen round /square (1x1)recessed fitting made of diecast aluminium having efficacy not less than 1101/w ,pf greater than 0.95 , THD less than or equal 10 % chip make cree/ Osram /lumilled /Nichea and giving necessary connections has required .
OD76267/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 35 sq mm with factory made clamp
OD76539/2025-2026:supply and fixing 125 A ,415 V,2 way neutral link mounted on DMC /SMC base in existing meter board
OD76540/2025-2026:supply and fixing 125 A fuse base with HRC fuse link in the existing meter board and giving connections etc.
OD76541/2025-2026:supply and fixing suitable type spreader terminal adapter kit extended terminal for 4 pole MCCB of rating up to 250 A (8 pcs )
OD76542/2025-2026:supply and wiring with ISI marked ,FRLS PVC insulated following size single core copper conductor cables for interconnecting the control devices/ equipment 's including the wiring firm by suitable tie/tie mounts /PVC duct etc with socket as required .1.5 sq mm single run
OD76543/2025-2026:supply and fixing panel mounted type earth leakage relay with CBCT and giving connections as required .(make ::L&T/Techno Commercial equivalent as approved by engineer in charge )
OD76544/2025-2026:providing and fixing 2 X 25 mm X 3 mm G.I. strip earth lead from the test join to the earthing system
OD76545/2025-2026:providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test join to the earth plate
OD76584/2025-2026:supplying drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface /recessed steel /PVC conduit as required .4 x 16 sq.mm
OD76585/2025-2026:supplying drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface /recessed steel /PVC conduit as required .1 x 16 sq.mm
OD76586/2025-2026:supply and fixing following rating surge protection devices (3 P+N) ,conforms to IEC 61643-11 Type 1+2(protection against direct and indirect lightning surges ) maximum discharge current -Imax up to 100 KA in existing cubicle panel board including drilling holes in cubicle panel, making connections ,etc. as required .(make L& amp ; Techno commercial equivalent )
Fire and safety requirements
OD68281/2025-2026:PVC CONDUIT SUPPLY INSTALLATION TESTING AND COMMISSIONING OF PVC CONDUIT
OD68282/2025-2026:CABLING SUPPLY INSTALLATION TESTING AND COMMISSIONING OF PVC INSULATED 1SQMM COPPER CABLE
OD68283/2025-2026:HOOTER (MS) SUPPLY INSTALLATION TESTING AND COMMISSIONING OF ELECTRONIC SOUNDER FOR PROVIDING AN AUDIO WARNING WHICH IS SUITABLE FOR PLACE WHICH NEED AUDIO INDICATION
OD68284/2025-2026:MANUAL CALL POINT (MS) SUPPLY INSTALLATION TESTING AND COMMISSIONING OF MANUAL CALL POINT OF RED COLOURED TOUGH DURABLE HIGHLY VISIBLE WITH ALARM LD TO INDICATE ALARM CONDITION AVAILABLE FOR FLUSH OR SURFACE MOUNTING
OD68285/2025-2026:FIRE ALARM CONTROL PANEL SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 04 ZONE CONVENTIONAL FIRE ALARM PANEL WITH 2x16 CHARACTER LCD DISPLAY NO / NC CONTACT FOR FIRE AND FAULT LCD AND LED INDICATION FOR OPEN SHORT CIRCUIT FIRE IN EACH ZONE ETC
OD68286/2025-2026:ABC TYPE FIRE EXTINGUISHER 04 KG SUPPLY INSTALLATION TESTING AND COMMISSIONING OF ABC TYPE FIRE EXTINGUISHER OF 04 KG WITH CONTROLLABLE DISCHARGE MECHANISM
OD68287/2025-2026:SINGLE DOOR SUPPLY INSTALLATION TESTING AND COMMISSIONING OF SINGLE DOOR HOSE CABINET OF INTERNAL TYPE TO PLACE ONE CP HOSE ALONG WITH COUPLINGS AND ONE BRANCH PIPE
OD68288/2025-2026:BRANCH PIPE SUPPLY INSTALLATION TESTING AND COMMISSIONING OF STAINLESS STEEL BRANCH PIPE WITH 63MM HEXOGONAL BASE NOZZLE
OD68289/2025-2026:FIRE HOSE SUPPLY INSTALLATION TESTING AND COMMISSIONING OF FIRE HOSE UL LISTED AND IS 636 TYPE A IN 15 MTR LENGTH OF 63MM DIA WORKING PRESSURE OF 175 PSI TESTED AT BURSTING PRESSURE OF 640 PSI WITH STAINLESS STEEL COUPLING BINDED WITH STAINLESS STEEL WIRE
OD68290/2025-2026:HOSE REEL DRUM - IMPORTED SUPPLY INSTALLATION TESTING AND COMMISSIONING OF HYDRULIC HOSE REEL DRUM ( WALL MOUNTED TYPE) HAVING IS : 884 STANDARD WITH SWINGING DRUM POWDER COATED RED FINISHED AT AN OPERATING PRESSURE OF 150 PSI AND FLOW RATE OF 16 GPM AT 100 PSI WITH 19 MM PVC HOSE HAVING LENGTH OF 30 MTR WITH STOP CPCK AND PVC NOZZLE AND OTHER FIXING ACCESSORIES
OD68291/2025-2026:FIRE STATION ACCESSORIES: HYDRANT VALVE SUPPLY INSTALLATION TESTING AND COMMISSIONING OF STAINLESS STEEL OBLIQUE TYPE SINGLE HEADED HYDRANT VALVE S: 304 OF 63MM DIAFLANGED INLET AS PER PN 16 AND 63MM DIA FEMALE INSTANTANEOUS COUPLING ADAPTOR WITH PVC BLACK ETC
OD68292/2025-2026:FIRE BRIGADE INLET -2 WAY SUPPLY INSTALLATION TESTING AND COMMISSIONING OF FIRE BRGADE INLET CONNECTION WITH 03 NOS OF 63 MM BUILT IN NON RETURN VALVES IN 100MM PIPE MANIFOLD DIRECTLY CONNECTED TO RISER
OD68293/2025-2026:AIR RELEASE VALVE 25 MM DIA SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 25 MM DIA AIR RELEASE VALVE SCREWED END TYPE WITH CAST IRON BODY
OD68294/2025-2026:BALL VALVE 25 MM DIA SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 25 MM DIA BALL VALVE SCREWED END TYPE WITH CASR IRON BODY
OD68295/2025-2026:MS B CLASS PIPE ABOVE GROUND SUPPLY INSTALLATION TESTING AND COMMISSIONING OF MS B CLASS PIPES CONFIRMING TO IS: 1239 WITH SPECIALS CONFIRMING TO IS: 1239 PAT 2 SUCH AS ELBOWS REDUCERS FLANGES ETC INCLUDING CUTTING WELDING FIXING ON WALLS OR CEILING BY USING SUITABLY SUPPORTS WITH TWO COATS OF ZINC CHROMITE YELLOW PRIMER AND ENAMEL PAINT RED COLOUR 100 MM DIA 80 MM DIA
OD68296/2025-2026:PRESSURE GUAGE SUPPLY INSTALLATION TESTING AND COMMISSIONING OF PRESSURE GAUGE OF 0-12KG RANGE WITH 4”SIZE DIAL
OD68297/2025-2026:PRESSURE SWITCH SUPPLY INSTALLATION TESTING AND COMMISSIONING OF PRESSURE SWITCH FOR AUTOMATIC OPERATION OF PUMPS
OD68298/2025-2026:NON RETURN VALVE - SLIM SEAL, CI SUPPLY INSTALLATION TESTING AND COMMISSIONING OF SLIM SEAL TYPE CAST IRON NON RETURN VALVES FITTED WITH NECESSARY DIA FLANGES GASKETS NUTS AND BOLTS ETC
OD68299/2025-2026:BUTTERFLY VALVE - LEVER OPERATED SUPPLY INSTALLATION TESTING AND COMMISSIONING OF WAFER TYPE BUTTERFLY VALVE, CAST IRON BODY, SS 420 SHAFT, MILD STEEL HANDLE, DISC OF SS 304 PRESSURE RATING OF PN 10 LEVER OPERATED TYPE AS PER IS: 13095 FITTED WITH NECESSARY DIA FLANGES GASKETS NUTS AND BOLTS ETC 100 MM DIA
OD68300/2025-2026:MCC PANEL FOR PUMP AUTOMATIC PANEL SUPPLY INSTALLATION TESTING AND COMMISSIONING OF MOTOR CONTROL PANEL FOR AUTOMATIC OPERATION OF TERRACE PUMP WITH DOL STARTER. THE PANEL SHALL BE PAINTED WITH ANICORROSIVE LACQUER AND WITH PROTECTIVE LOCKABLE ARRANGEMENT.
OD68301/2025-2026:TERRACE PUMP 450 LPM, 5HP SUPPLY INSTALLATION TESTING AND COMMISSIONING OF HORIZONTAL MOUNTED MONO BLOCK THREE PHASE PUMP SET WITH CAST IRON CASING CAST IRON IMPELLER COUPLED TOA SQUIRELL CAGE INDUCTION MOTOR TEFC TYPE WITH SUPPLY CODITION OF 415 V 3 PH 50 HZ RATED FOR 450 LPM 5 HP AT 2900 RPM
Supplying and fixing Solar pannels
OD256449/2024-2025:Design supply installation and testing and commissioning of roof top on grid solar power plant which comprise of the following items (total trunkey basis) it also include civil work electrical work and other relevant work of projects Indicative Bill of Materials for standard package of roof top solar plant S.No Materials Standard/specification 1 10 kw Solar PV Panel modules consisting of mono crystalline pv modulesAs per MNRE specification/standards and registered in ALMM 2 Grid Connected Inverter/pcu(s) required for 10 kw solar As per MNRE/BIS Standard regulations 3 Module Mounting Structure (MMS) as per onsite requirement Galvanized as per applicable IS 4 Structure Accessories as per onsite requirement Stainless Steel 304 5 Net Meter and Solar meter As per DISCOM requirements 6 Array Junction Box required for 10 kw solar Protection as per Inverter requirement 7 AC Distribution Board required for 10 kw solarProtection as per Inverter & DISCOM/Grid requirement 8 Solar DC Cables required for 10 kw solarTotal 50 metre in length and as per MNRE specifications 9 AC Cables required for 10 kw solar 10 EarthingAs per MNRE specifications 11 Lightning Arrestor MNRE specifications 12 Earthing Cable / Strip MNRE specifications 13 Connectors, Conduit pipes etc MNRE specifications 14 Accessories As per requirement 15 Other Items required to complete project As per requirement 16 Installation Testing & Commissioning As per safety norms of SERC/ CEA 17 Civil materials As per MNRE specifications 18 Civil Work As per MNRE specifications 19 Performance Testing Minimum 75% 20 Warranty With all mandatory certifications the product warranty for solar panels should be 10 year and performance warranty should be of 25 year the date of commissioning including ADDITIONAL STRUCTURAL STEEL (SUPPORT STRUCTURE FOR SOLAR PANELS) WITH 75 x 75 x 5 MM GI COATED SQUARE HOLLOW SECTIONS:- For providing fabricating and fixing in position of structural steel (support structure for solar panels) with 75 X 75 x 5 mm GI coated square hollow sections of Jinda I/ Tata make for fixing of solar panels as show in the detailed approved drawings including cutting, welding, hosting & including cost and conveyance of all materials, all taxes, labour charges for fabrication erection at site work for all heights etc., complete as directed by the Engineer-in-charge for finished item of work Supplying and fixing solar panels including product cost,KSEB charges and structure cost (flat roof)
Lab Waste Water Treatment Plant
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
50.18.7.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
OD240697/2025-2026:Supplying and fixing 15/16 amp switch modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Derived from DSR Electrical 1.24.3
OD240696/2025-2026:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.3 Module . Derived from DSR Electrical 1.28.2
OD240695/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet. Derived from DAR Electrical 1.24.5
OD240694/2025-2026:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Deriver from DAR Electrical 1.5
OD240693/2025-2026:Supply and Installation of Water filter 1354 iron removal filter and Carbon with Dosing Pump having the following specification. such as FILTRATION VESSEL •Model 1354 x 2 Vessels •Category Structural Poly glass Vessel •System filtration capacity 1500-2000 Ltr per day Max / Vessel •Filtration technology Slow/ pressure sand filtration •Minimum burst at 600 psi •Unmatched for strength and chemical resistance •Tested to 250,000 cycles without leakage •Vessels tested and certified by the Water Quality Association (WQA) to NSF/ANSI Std. 44 for material safety and structural integrity requirements and Std. 372 for low lead compliance. FILTRATION MEDIA •Base media Silex •Separation media Course siles/ sand •Filtration media Fine sand – high silica •Iron removal media DMI-65 •Absorption media Activated Carbon IV-1050 Grade MULTI PORT VALVES •Inlet / outlet 1 inch •Mode Filter, Rinse, Backwash •Colour Black •Operation Semi-Automatic DOSING PUMP •Dosing Rate 1.5; 3.0; 6.0 & 10.0 Lph @ 4 Kg/Cm2 •Power consumption 30 Watts •SPM Up to 400 spm •Suction Tubing 4/6 mm •Voltage 230 V AC
OD240692/2025-2026:Supply and Installation of 1000L DOUBLE LAYER UNDERGROUND WATER TANK SUMPS having the following specifications such as • Brand Sintex • Diameter 1200 mm • Manhole Size 400 mm • Double Layer, Easy to Install, Lightweight • Easy to Transport. • Impermeable to Roots of Trees • Durable & Economica
OD240691/2025-2026:Supply and Installation of .5 HP MOTOR having the following specifications such as • Brand V-Guard • Model Name O.5 HP NEON WSH-100 WONDER SUCTION • Type Centrifugal • Usage Type Domestic • Color Yellow, Black • Body Material Aluminium • Applications lawn and garden, buildings, hospitals, hotels, highrise buildings • Adjustable Speed No • Battery Backup No • Flow Rate 23.3 Lpm • Total Head 30 m • Inlet Size 12.5 mm • Outlet Size 12.5 mm
OD240690/2025-2026:Supply and Installation of AUTOMATIC FLOAT SWITCH having the following specifications such as • Manufacturer Sinicon Controls • Item model number System 1A • Fully Automatic Water Level & Pump Control System • The system consists of one Switch mate & one Water switch with 2M Cable • Easy installation. Fit and forget type - No routine maintenance required. • Voltage 115-270V, Direct Load 1HP, IP40
OD240689/2025-2026:Supply and Installation of 2x1.5 sq.mm + 1x1.5 sq.mm earth wire derived from DSR Electrical 1.14.1
OD240688/2025-2026:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required. 25 mm. Derived from DAR Electrical 90.1.1.2
stage.html
html • 0.03 MB
finance_1389676.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.88 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.19 MB
NIT07.pdf
Tender Documents • 0.94 MB
drawingsandsoilreport.pdf
Other Document • 6.50 MB
BOQ_1389676.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .