Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹16.1 L+₹1.7 L (11.8%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹16.8 L+₹2.4 L (16.6%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Jan 2023, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
MAINTENANCE AND REPAIRS TO COOLING APPLIANCES LIKE REFRIGERATORS / WATER COOLERS / DESERT COOLERS / DEEP FREEZERS AND AIR CONDITIONERS AT AIR FORCE STATION BIDAR
2022_MES_571335_1
85584/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF BIDAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AF BIDAR
₹40,000
Yes
2 Feb 2023
26 Dec 2022
1 Feb 2023
26 Dec 2022
30 Jan 2023
16 Jan 2023
26 Dec 2022 - 11 Jan 2023
Amount
REFRIGERATORS :- Disconnection and removing the unserviceable Refrigerator of Capacity 190 / 210 ltrs from the existing position for finding out the defects and to replace the unserviceable Compressor and leak detection by charging the Dry Nitrogen Gas & arresting the leakage by Gas welding method, charging of refrigerant Gas and refixing the refrigerator to its original position complete all as specified and as directed. Make of existing Refrigerators :- Godrej / Electrolox Kelvinator / Samsung Note :- Cost of compressor, refrigerant and leak testing with nitrogen will be measured and paid under the respective item as '' Supply '' only
Disconnection and removing the unserviceable Refrigerator of Capacity 280 / 300 / 308 / 310 / 320 ltrs from the existing position for finding out the defects and to replace the unserviceable Compressor and leak detection by charging the Dry Nitrogen Gas & arresting the leakage by Gas welding method, charging of refrigerant Gas and refixing the refrigerator to its original position complete all as specified and as directed. Make of existing Refrigerators :- Godrej / Electrolox / Kelvinator / Samsung Note :- Cost of compressor, refrigerant and leak testing with nitrogen will be measured and paid under the respective item as '' Supply '' only
Supply only hermatically sealed Compressor Unit of Capacity 190 / 210 ltrs Single Phase suitable for Refrigerator complete all as specified and as directed. Make :- LG / Hitachi / Voltas Note : - Labour element included in Item No 1 above.
Supply only hermatically sealed Compressor Unit of Capacity 280 / 300 / 308 / 310 / 320 ltrs Single Phase suitable for Refrigerator complete all as specified and as directed. Make :- LG / Hitachi / Voltas Note :- Labour element included in Item No 2 above.
Disconnection and removing the unserviceable thermostatic switch and S & F new thermostatic switch suitable for existing 190 to 320 ltrs refrigerator complete all as specified and as directed.
Disconnection and removing the unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable for existing 190 to 320 ltrs refrigerator complete all as specified and as directed.
Disconnection and removing the unserviceable Timer switch, and S&F Timer switch of same size and capacity suitable for existing 190 to 320 ltrs refrigerator of existing make complete all as specified and as directed.
Disconnection and removing the unserviceable broken freezer door plastic, and S&F New Door unit of same size and capacity suitable for existing 190 to 320 ltrs refrigerator of existing make complete all as specified and as directed.
Disconnection and removing the unserviceable fused electric bulb, and S&F Bulb Unit of same size and capacity suitable for 190 to 320 ltrs refrigerator complete all as specified and as directed.
Disconnection and removing the unserviceable Fan with motor, and S&F Fan Motor of same size and capacity suitable for 280/300/308/310/320 ltrs refrigerator of makes as existing at site complete all as specified and as directed.
Disconnection and removing the unserviceable Over Load Protector Unit, and S&F Over Load Protector Unit of same size and capacity suitable for 190 to 320 ltrs refrigerator of makes as existing at site complete all as specified and as directed.
WATER COOLERS :- Disconnection and removing the electric and water supply connections connected to the water cooler of capacity 40/80 Ltrs capacity for replacement of Compressor , Fan Motor, Condensor coil or for leak testing by dry Nitrogen gas and charging the Refrigerant as required and fixing back in its original position connecting the electric and water connections testing and commissioning complete to the satisfaction of Engineer-in-Charge. Make :- Usha / Shriram Refrigeration /AC Cooler / Blue Star
Note :- (i) Cost of spares such as Compressor, refrigerant and nitrogen gas test shall be measured and paid separately under the respective Item as " Supply Only" (ii) Makes & Specifications of the spare parts for replacement should be identical equivalent to the spares suitable for existing Water Coolers.
Supply only hermatically sealed Compressor Unit of Capacity suitable for 40 / 80 ltrs Single Phase for water coolers of existing make . Make : - Usha / Blue star Note :- Labour element included in Item No 12 above
Supply only New Fan Motor unit , Single phase, 230 volts 50 Hz of same size and capacity suitable for 40/80 Ltrs Water Cooler of existing make complete all as specified and as directed. Note :- Cost of Labour element is considered in item No 12 above
Supply only condenser Coil suitable for 40 /80Ltrs Single Phase for water coolers of existing make complete all as specified and as directed. Note : - Cost of Labour element is considered in item No 12 above
Disconnection and removing the unserviceable burnt thermostatic switch and S & F New thermostatic switch suitable for40/ 80 Ltrs Water Cooler of existing make complete all as specified and as directed.
Disconnection and removing the unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable suitable for 40/ 80 Ltrs Water Cooler as per samplecomplete all as specified and as directed.
Disconnection and removing the unserviceable Timer switch, and S&F Timer switch of same size and capacity suitable for 40/ 80 Ltrs Water Cooler as per sample complete all as specified and as directed.
Disconnection and removing the unserviceable Over load protector unit, and S&F Over load protector unit of same size and capacity suitable for 40 / 80 Ltrs Water Cooler as per sample complete all as specified and as directed.
Disconnection and removing the unserviceable Chromium plated push cock / lifting cock and S&F Chromium plated push cock / lifting cock of 15 mm dia of same size and capacity suitable for 40 / 80 Ltrs Water Cooler as per sample complete all as specified and as directed.
Disconnection and removing the unserviceable Ball valve of PVC high pressure with polythene float & flynut and S&F Ball valve of PVC high pressure with polythene float & flynut of 15 mm dia and capacity suitable for 40 / 80 Ltrs Water Cooler as per sample complete all as specified and as directed.
Disconnection and removing the unserviceable PVC connections connected to the water cooler and S&F PVC Connection suitable for water cooler of capicity 40/80 Ltrs water cooler as per sample complete all as specified and as directed.
DESERT COOLERS :- Disconnection and removing the unserviceable Desert Cooler fan motor and S & F fan motor working on 230 Volts, 50 HZ, 1/7 HP 1300 RPM AUE or Khaitan Make for desert coolers complete all as specified and as directed.
Disconnection and removing the unserviceable Desert Cooler vertical pump and S & F New vertical pump 1/66 HP, 230 Volts, 50 HZ. AUE or Khaitan Make for desert coolers complete all as specified and as directed.
Disconnection and removing the unserviceable Khas - Khas / wood wool pads and S & F new Khas - Khas / wood wool pads of same size and good thickness for desert cooler to the satisfaction of Engineer-in-Charge.
Taking out the old damaged front grill unit and replace the same with new front grill as per sample suitable for desert cooler complete all as specified and as directed.
Disconnection and removing the Desert cooler body and S & F New desert cooler body made of iron of existing size,gauge and weight complete all as specified and as directed.ed
Taking out faulty distributer system consisting of PVC elbow and PVC pipe and Supply and fix new water distributer 3 way consisting 3 Nos of PVC elbow and 1/2 " heavy duty PVC Pipe of length upto 2 mtrs suitable for existing desert coolers complete all as specified and as directed.
DEEP FREEZERS :- Disconnection and removing the unserviceable burnt compressor unit from the deep frezer, replacing the same with new hermatically sealed compressor unit alongwith its connected items, including carried out leak testing by dry nitrogen gas, charging of refrigerant after ensuring leak proof conditioned, Testing and commissioning of deep freezer of capacity 200/210 ltrs ltrs. Make :- Blue Star
Disconnection and removing the unserviceable burnt compressor unit from the deep frezer, replacing the same with new hermatically sealed compressor unit alongwith its connected items, including carried out leak testing by dry nitrogen gas, charging of refrigerant after ensuring leak proof conditioned, Testing and commissioning of deep freezer of capacity 300 ltrs ltrs. Make :- Blue Star
Disconnection and removing the unserviceable thermostatic switch and S & F thermostatic switch suitable for 200 to 300 ltrs deep frezer complete all as specified and as directed.
Disconnection and removing the unserviceable burnt Fan motor unit from the deep freezer and S&F New Fan Motor unit , Single phase, 230 volts 50 Hz of same size and capacity suitable for 200/210 ltrs deep freezer as per sample complete all as specified and as directed.
Disconnection and removing the unserviceable burnt Fan motor unit from the deep freezer and S&F New Fan Motor unit , Single phase, 230 volts 50 Hz of same size and capacity suitable for 300 ltrs deep freezer as per sample complete all as specified and as directed.
Disconnection and removing the unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable for 200 t0 300 ltrs deep frezer complete all as specified and as directed.
Disconnection and removing the unserviceable Timer switch, and S&F Timer switch of same size and capacity suitable for 200 t0 300 ltrs deep frezer complete all as specified and as directed.
Disconnection and removing the unserviceable broken freezer door plastic, and S&F New Door unit of same size and capacity suitable for 200 t0 300 ltrs ltrs deep frezer complete all as specified and as directed.
Disconnection and removing the unserviceable fused electric bulb, and S&F Bulb Unit of same size and capacity suitable for 200 to 300 ltrs deep frezer complete all as specified and as directed.
Disconnection and removing the unserviceable Over Load Protector Unit, and S&F Over Load Protector Unit of same size and capacity suitable for 200 to 300 ltrs deep frezer complete all as specified and as directed.
SPLIT TYPE AIR CONDITIONERS :- Disconnection and removing the unserviceable Condensor Fan Motor and S & F New Condenser Fan Motor suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed.
Description all as per Ser item No 40 above but of capacity 2.0 Ton Capacity complete all as specified and as directed.
Description all as per Ser item No 40 above but of capacity 3.0 Ton Capacity complete all as specified and as directed.
Disconnection and removing the unserviceable Condensor Coil Unit and S&F new Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as specified and as directed.
Description all as per Ser item No 43 above but of capacity 2.0 Ton Capacity complete all as specified and as directed.
Description all as per Ser item No 43 above but of capacity 3.0 Ton Capacity complete all as specified and as directed.
Disconnection and removing the unserviceable Suction Valve and S & F new Suction Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as specified and as directed.
Description all as per Ser item No 46 above but of capacity 2.0 Ton Capacity complete all as specified and as directed.
Description all as per Ser item No 46 above but of capacity 3.0 Ton Capacity complete all as specified and as directed.
Disconnection and removing the unserviceable Discharge Valve and S & F new Discharge Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as specified and as directed.
Description all as per Ser item No 49 in above but of capacity 2.0 Ton Capacity complete all as specified and as directed.
Description all as per Ser item No 49 above but of capacity 3.0 Ton Capacity complete all as specified and as directed.
Disconnection and removing the unserviceable PCB/ Mother Board Unit and S & F new PCB Mother Board alongwith Remote Control Unit suitable for 1.5 Ton Split Type Air Conditioner of Make LG / BLUE STAR / VOLTAS / HITACHI complete all as specified and as directed.
Disconnection and removing the unserviceable PCB/ Mother Board Unit and S & F new PCB Mother Board alongwith Remote Control Unit suitable for 2 ton Split Type Air Conditioner of Make LG / BLUE STAR / VOLTAS / HITACHI complete all as specified and as directed.
Supply and Charge Refrigerant (R-22) / F-22 / R-410A/R-134/R-32 suitable for existing 1.5/2/3 Ton Capacity Split / Window type air conditioning unit complete all as specified and as directed.
Disconnection and Removing the unserviceable Running / Starting Capacitors from the Outdoor units of Split Type AC Unit 1.5/2/3 Ton Capacity and S&F New Capacitors of capacity 50 MFD 230 Volts, ISI Marked complete all as specified and as directed.
Disconnection and Removing the unserviceable Running / Starting Capacitors from the Outdoor units of Split Type AC Unit 1.5/2/3 Ton Capacity and S&F New Capacitors of capacity 55 MFD, 230 Volts, ISI Marked complete all as specified and as directed.
Disconnection and Removing the unserviceable /broken Fan Blade from the Outdoor units of Split AC Unit 1.5 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit complete all as specified and as directed.
Disconnection and Removing the unserviceable / broken Fan Blade from the Outdoor units of Split AC Unit 2 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit complete all as specified and as directed.
Disconnection and Removing the unserviceable Electrical Connectors and S&F New Electrical Connectors 3 Pole suitable to connect Single Phase Power Supply between Indoor and Outdoor Unit of Capacity 1.5 / 2/3 Ton complete all as directed.
Disconnection and removing the old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia and connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as specified and as directed.
Description all as per Ser Item No 60 above but of capacity 1/4" dia complete all as specified and as directed.
Description all as per Ser Item No 60 above but of capacity 3/8" dia complete all as specified and as directed.
Description all as per Ser Item No 60 above but of capacity 5/8" dia complete all as specified and as directed.
Disconnection and removing the unserviceable compressor from Split AC Outdoor of capacity 1.5 Ton Capacity and Supply and fix New hermatically sealed compressor suitable for LG/Hitachi/Voltas/Blue star Split AC's including Vacuumising,Leak testing & Gas charging and testing complete all as specified and as directed.
Description all as per Ser item No 64 above but of capacity 2.0 Ton Capacity complete all as specified and as directed.
Description all as per Ser item No 64 above but of capacity 3.0 Ton Capacity complete all as specified and as directed.
Disconnection and removing the old unserviceable Outdoor Stand and S&F New Outdoor Stand made of Iron bracket to accomodate the air conditioner along with fixing materials complete all as specified and as directed.
Disconnection and removing the unserviceable / burnt out Copper Cable between Indoor & Outdoor Unit and S&F PVC Insulated, PVC Sheathed, Multistranded Copper Cable 3 Core 2.5 Sqmm, ISI Marked, 1100 volts Grade and connecting to the unit along with necessary fixing materials complete.
Description all as per Ser Item No 68 above but of 3 Core, 4 Sqmm capacity complete all as specified and as directed.
Description all as per Item No 68 above but of 3 Core, 6 Sqmm capacity complete all as specified and as directed.
Disconnection and removing the unserviceable Blower Unit of Indoor unit Split type AC Conditioner and S&F Blower Unit of same make, size and capacity suitable for 1.5 Ton for Air Circulation complete all as specified and as directed.
Description all as per Item No 71 above but of capacity 2.0 Ton Capacity complete all as specified and as directed.
Description all as per Ser Item No 71 above but of Capacity 3 Ton Air conditioning unit complete all as specified and as directed.
Disconnection and Removing the damaged Flexible PVC Drain Pipe of dia 25 mm and S&F New Standard Flexible PVC Drain Pipe of dia 25 mm for capacity 1.5 ton, 2.0 ton & 3 Ton capacity complete all as specified and as directed.
Supply and fixing in replacement condensed water tray of existing size and make for split AC Indoor unit complete all as specified and as directed.
Disconnection and Removing the defective / damaged Industrial Plug & Socket Board and supply & fix Industrial Plug & Socket controlled by 01 No 20 Amp MCB Single Pole ISI Marked in and including sheet metal enclosure suitable for 1.5/2 Ton capacity complete all as specified and as directed.
Disconnection and Removing the Cable connections by Pumpdown the refriegerant and removing the Copper Pipe alongwith all connected items carefully from the existing indoor and out door units and from Outdoor Unit of tonnage 1.5/2/3 Ton including stabilizer from the existing positions and shifting the AC unit at new place and refixing the outdoor and indoor units with necessary copper tubing including topping up of gas and connecting stabilzer etc for its proper functioning complete all as specified and as directed.
Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete all as specified and as directed. Note :- The cost of refrigerant will be measured and paid separately under the respective item of Schedule A.
VOLTAGE STABILISER :- Disconnection and removing defective / burnt control center tapped transformer (12 V - 0 12 V ) connected to PCB and Supply and fix new core coil for voltage stabiliser of capacity 5 KVA capacity complete all as specified and as directed.
Description all as per Ser item No 79 above but for capacity upto 4 KVA complete all as specified and as directed.
Description all as per Ser item No 79 above but for capacity upto 3 KVA complete all as specified and as directed.
Disconnection and removing PCB (Printed Circuit Board) complete with components and Supply & Fix new PCB complete with components of 5 KVA Voltage stabiliser complete all as specified and as directed.
Description all as per Ser item No 82 above but for capacity upto 4 KVA complete all as specified and as directed.
Description all as per item No 82 above but for capacity upto 3 KVA complete all as specified and as directed.
Disconnection and removing the faulty relay and Supply and fix new relay for voltage stabiliser 3.0 KVA / 4.0 KVA / 5.0 KVA capacity complete all as specified and as directed.
Description all as per Ser item No 85 above but for capacity 2.5 / 2.0 / 1.0 / 0.5 KVA complete all as specified and as directed.
Disconnection and removing the unserviceable volt meter 0 to 300 Volts, Round / Square type. Supply and fix the same type volt meter. 0 to 300 Volts in Voltage stabiliser complete all as specified and as directed.
Disconnection and removing the burnt connector and Supply and fix electric connector 20 Amps in Voltage stabiliser complete all as specified and as directed.
Disconnection and removing the unserviceable single pole contactor 30 Amps & Supply and fix new single pole contactor 30 Amps, coil voltage 220-230 Volts AC suitable for split AC 1.5/2 Ton capacity all as specified and directed by Engr- in- Charge.
BHATNAGAR ASSOCIATES
RASI AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .