| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ok |
| 2 | Accepted-Technical | Accepted-Technical ok |
| 3 | Accepted-Technical | Accepted-Technical ok |
Tender Value
₹3.4 L
EMD Value
₹6,839
Closing Date
3 Mar 2026, 9:00 amClosed
Prodhan Magurmari- I GP
Kalirhat Magurmari Dhupguri
CONSTRUCTION OF SOLAR DRINKING WATER NEAR H/O KESHAB ROY AT PART NO 15/114 UNDER MAGURMARI-I GP, DHUPGURI BLOCK
2026_ZPHD_1013498_2
003/MGP-I/25-26
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
30 days
Magurmari- I GP area
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
5694101000001 CNRB0005694
₹6,839
13 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
3 Mar 2026
24 Feb 2026
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (i) 50 mm dia. boring etc.
(ii) 100 mm dia. boring etc. top enlargement
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (ii) 50 mm dia.
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (ii) 50 mm
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (vi) 50 mm
Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Supply of P.V.C pipes of make including necessary sockets (f) 50 mm dia. (ii) Medium quality
(i) 100 mm dia. (i) Medium quality
Supply fitting ,fixing of Signboard
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.500 mm.
(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety In ground floor (a) 1:3:6 proportion
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. Other than SAIL/TATA/RINL
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (ii) CPVC Pipes Class-2,SDR-13.5 From Storage Tank to Stand Post 25 mm
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1500 litre capacity
(g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. (i) 15 mm
((b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Solar Module: Supply, transport, installation and commissioning of ISI marked solar module as per following specification. 1. Cell: Indigenous mono crystalline silicon SPV cells. 2. Solar Module: Monocrystalline cell with PERC technology/module with bifacial cell 3. Standards: ISI marked as per IS 14286 and having certification of IEC 6183(1), 61730(1&2), 61710 4. Modules must quality to IS 170210(Part 1) 5. Min efficiency 19.5% 6. Fill factor: More than 75% 7. Module wattage mismatch in the SPV array: within +3% 8. Wattage output warranty: Should be less than 90% at the end of 10 years and 80% at the end of 25 years. 9. Power output of individual PV modules used in the PV array, under STC minimum 300Wp. Necessary test certificate also to be supplied. For detail information please see cl. No 2.1 of technical specification. b) For 2HP Off-Grid Solar water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV Modules
Module Mounting Structure: Supply, transportation & Installation of GI manual tracking/Fixed structure made of MS Hollow Section, Pipes, Plates, angles etc as per IS4923, IS:1161/1239, IS:1079/2062, to hold min 300Wp SPV Module as per drawing and technical specification. The steel structure is to be protected with minimum 80 micron galvanization (hot dip) and provided with fixed arrangement of dual axis manual tracking arrangement for three times in a day and seasonal lilting to face the sun optimally.
Power conditioning unit with enclosure: Supply, transportation, Installation and commissioning of Solar Power Conditioning Unit consisting of following components and features 1. Variable frequency Drive with inbuilt MPPT, Voltage range suitable for operation pump-motor set of 1HP to 20 HP, detail mentioned in cl 6.1 2. Power input: DC source for 1HP, 2HP and 3HP 3. Power input: AC/DC source or hybrid for 5HP and above 4. Incomer: DC MCB 2 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 5. Incomer: AC MCB 4 Pole 16 amp upto 5HP, 25 amp for 7.5HP and 10HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2 6. Type II DC SPD of 40 KA 7. Type II AC SPD 40 KA for AC/DC or Hybrid input 8. Dual input (Solar/Grid) 25 amp changeover switch for 5H and 7.5HP, 40 amp for 10HP, 63 amp for 15 to 20 HP 9. Reverse protection diode 1600 VDC with heat sink 10. Data logger 11. Remote monitoring system 12. Should have built –in EMC filters 13. IP 65 glands for cable in and out 14. Min. IP 54 enclosure. For details features, protection, RMS, communication architecture, security Data storage, tolerance or various parameters, standards to be qualified, etc. please refer to cl. 6.1 of technical qualification.
Cable and Accessories: Supplying, fitting and fixing of UV rated Copper cable laid inside HDPE conduit and other accessories as per following with necessay connection with the Solar PV Module, MPPT etc I. 4.0 Sqmm Single core multi studs-5m (for 1HP/2HP/3HP) ii. Lugs, HDPE Pipe, Flexible pipe, saddle, cable tie etc a) For 1HP/2HP/3HP per structure
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of each electrode and filling & ramming and connection to individual structure to earth electrode including S&F 20mmx3mm galvanized (Hot Dip) MS flat on Wall/floor with GI saddles as required and connecting to equipments incl. drilling holes, with bolts, nuts, washers etc.
Lighting system a scheme (with lighting Pole) Dusk to dawn lighting arrangement at 4 mts height above ground level, with Hot dip Galvanised 80mmx50mm, medium duty pipe with 12V, 15Ah 2-in-1 Lithium ion/Ferro- Phosphate battery with in-built 7-11 Watt LED lamp, 50 Wp solar panel (min 19% eff.) to cover the scheme area. The lighting system should be warranted for 5years for the date of installation
Supplying , fitting and fixing of Sand Filter - Manual as per IS:14606 Sand Filter10m³/hr-M Single
Lighting protection (Pole mounted): Lighting protection with 3”x1.5” GI pipe of 6m+1m height with base flange in proper RCC foundation and S&F Lighting Conductor Air Terminal made of 20mm dia 1000mm long GI pipe (ISI Medium) having five discharge prongs of 4SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip0 wire and 85 mm dia 6mm thick GI base plate at bottom incl. necessary holes etc. Eating with 65mm dia GI pipe (Medium) 3.0mts long and 1/9/10 stranded GI (Hot Dip) wire (4 mts long) 20mm dia x125mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire crimping sockets/ thimbles and S&F 65mm dia GI Pipe (ISI-Medium) protection (3 mts. Long) to be filled with bitumen partly under the ground level and partly above the ground level to an average depth of 3.65 Mts. Including connection to earth electrodes with 25x6mm GI strips
Supply and Installation of 3 Phase AC electromotor Pump-motor set with speed of 3000 rpm (synchronous speed) suitable for Solar applications and shall have 60 months guarrentee for folloing conditions including loading, unloading, transportation etc a) 1 HP 3 phse AC Surface Mounted Monoblock Pump-Motor set as per IS 9079 with discharge of 5.0-6.0 Lps at 8 mts total head with required quantity of flexible deliver pipe (10m), clamps, cable and all other accessories to complete connection of suction and delivery side.
Testing and commissioning of scheme after completion of all work
Cleaning and washing of modules once in month with clear water to remove diposited dust and dirt on the dodule surface and deep the modules clean throughout the ear. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at the site for the said purpose
Comprehensive maintenance charges for 5 years (which cover onthly inspection, Yearly training to WUA, to atted breakdown within 3 days and to keep the scheme in operation without lapse of time) a) for 2 HP both for submersible & Surface pump
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
BOQ_2489380.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .