Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC Lowest bidder and found in order. Contract awarded. | |
| 2 | L2₹29.7 L+₹55,267 (1.90%)Rejected-Finance NO 17 PETER GNANA PRAKASAM NAGAR MARIYAMMAN KOVIL PO THANJAVUR 611501 | 611501 | L2 | Rejected-Finance Rate quoted higher than L1 | |
| 3 | L3₹32.2 L+₹3.1 L (10.7%)Rejected-Finance | L3 | Rejected-Finance Rate quoted higher than L1 | |
| 4 | L4₹32.9 L+₹3.8 L (13.0%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L4 | Rejected-Finance Rate quoted higher than L1 | |
| 5 | L5₹33.6 L+₹4.5 L (15.5%)Rejected-Finance | L5 | Rejected-Finance Rate quoted higher than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Mar 2020, 6:00 pmClosed
GARRISON ENGINEER AIR FORCE THANJAVUR
GARRISON ENGINEER (AIR FORCE), AIR FORCE STATION, PUDUKKOTTAI ROAD THANJAVUR
REPAIR, MAINTENANCE REPLACEMENT OF STREET LIGHT FITTING / FIXTURES WITH CONNECTED WORK IN DOMESTIC AND TECH AREA AT AFS THANJAVUR
2020_MES_327452_2
8762/E8
Open Tender
Electrical Maintenance Service
Item Rate
270 days
THANJAVUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIR FORCE THANJAVUR
₹70,000
Yes
3 Apr 2020
16 Mar 2020
30 Mar 2020
16 Mar 2020
28 Mar 2020
16 Mar 2020
Amount
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories including taking down old unserviceable cable.
All as per Item No 1 here-in-before but 16 sqmm 2 core.
All as per Item No 1 here-in-before but 16 sqmm 4 core.
All as per Item No 1 here-in-before but 25 sqmm 3.5 core.
All as per Item No 1 here-in-before but 35 sqmm 3.5 core.
Supply and fixing/laying in replacement 50 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric pole / wall for protection of cable complete all as specified and as directed.
Supply and fixing/laying in replacement 40 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric pole / wall for protection of cable complete all as specified and as directed. Note for sl No 6 & 7 : The rate quoted by the contractor shall include the rate for providing MS Clamps 40x4mm with Nuts, bolts & washers for fixing of GI pipes on poles as reqd and as directed.
Material and labour in replacement of alluminium cable thimbles of size 50 Sqmm UG Cable including complete connection and crimping. Make : Jaipuriya / Rastriya / Dowells.
All as per Item No.8 above but 35 Sqmm.
All as per Item No.8 above but 25 Sqmm.
All as per Item No.8 above but 16 Sqmm.
All as per Item No.8 above but 10 Sqmm.
Supply and fix in replacement electronic driver (Printed circuit board) suitable for 150 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC supply complete all as directed. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor sholud be visit the site before quoting the rates so as to avoid the ambiguity during execution stage.
All as per item No 13 here in before but for 120 watt.
All as per item No 13 here in before but for 90 watt.
All as per item No 13 here in before but for 80 watt.
All as per item No 13 here in before but for 45 watt.
All as per item No 13 here in before but for 35/40 watt.
All as per item No 13 here in before but for 25 watt.
All as per item No 13 here in before but for 20 watt.
Supply and fix in replacement surge protection devices surge voltage 5 KV suitable upto 45 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC supply complete all as directed. Make : Havells /CG / Bajaj. Note : The make of surge protection device should be match with the make of LED light fitting installed at site and the contractor sholud be visit the site before quoting the rates so as to avoid the ambiguity during execution stage.
All as per item No 21 here in before but for upto 150 watt LED light fitting.
Supply and fixing in replacement LED Street light 120 Watt NEO N Endura City liner NEO/NEO N made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed. Make : Havells Cat Part No. ENDURACITYLINERNEOOSL120WLED757SASYBOTG or Equivalent in CG & Philips.
Supply and fixing in replacement LED Street light 45 Watt ENDURA PEARL NEO new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and directed. Make : Havells Cat Part No.ENDURAPEARLNEOSL45WLED757SASYTOPC or Equivalent in CG & Philips.
Supply and fix in replacement junction box of size 200mm x 150mm x 100mm made out of FRP of Make Sintex / Finolex with double stud hinged door locking including fixing hardware on Steel tubular pole or PCC pole in and including MCB 6 amps - 1 Nos with dinrail for mounting of MCB including suitable connector for looping duly sealed with rubber plugs complete all as specified and directed.
S&F MCB, Triple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
Supply and fix in replacement GI pipe bracket made out of medium grade 40 mm bore GI tubing duly bend to the required shape length of the bracket shall be not less than 1.5 m including MS flat iron clamps, nuts, bolts and washers for fixing of bracket on pole complete all as specified and directed.
Material and labour for painting to existing surfaces of street light steel tubular poles with 2 coats of aluminium paint over the existing surface including brackets clamps junction boxes etc including writing of pole number all as specified and as directed.
Supply and errection steel tubular swaged pole type 410 SP-31 (9 Mtr long) complete with CI base plate, taper plug, bolts, nuts, and screws etc duly painted with metal oxide anti corrosive paint before errection and painting with two coats aluminium paint after errection complete all as confirming to IS 2713 (part-1 to 111) including taking out old unserviceable pole complete all as specified and directed. Note : 1. Unit rate quoted shall be deemed to be inclusive of necessary earth work excavation and demolition of foundation and coping concrete. 2. PCC in foundation and coping shall be measured and paid separately. 3. The rate quoted by the contractor shall include the rate for applying / fixing of radium paint / strip on pole duly in different colour of size 10 cm x 5 Nos (Red, Yellow, Blue, Green & Black) between the interval of 15 cm & numbering of poles in white colour in black back ground.
Material and labour for cement concrete in foundations, filling PCC type D2 1:4:8 (with 40 mm graded aggregate) and making good surface all as specified and directed.
Material and Labour coping of pole with PCC type C1 1:3:6 (with 20 mm graded aggregate) and making good surface all as specified and directed.
Cutting of bushes vegetation removing and making the area clean at places around street light poles complete all as specified and as directed.
Dismantling and taking out the unserviceable street light fitting HPSV upto 400 watts from steel tubular pole / PCC pole / High mast etc and replacing the following defective accessories with new and making the street light in serviceable condition and refixing back in position connecting and testing complete all as specified and as directed. Note : Accessories such as lamp, choke and igniter will be measured and paid for separately under relevant items.
Supply and fix in replacement ballast for HID lamps open construction suitable for 70 watt SON/MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement ballast for HID lamps open construction suitable for 150 watt SON/MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement ballast for HID lamps open construction suitable for 250 watt SON/MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement ballast for HID lamps open construction sutable for 400 watt SON/MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement metal halide single ended clear tubular lamp for 70 watt MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement metal halide single ended clear tubular lamp for 150 watt MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement metal halide single ended clear tubular lamp for 250 watt MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement metal halide single ended clear tubular lamp for 400 watt MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement high pressure sodium vapour tubular lamp for 70 watt MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement high pressure sodium vapour tubular lamp for 150 watt MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
Supply and fix in replacement D type short distance ignitors with stud for 70 - 400 watt SON/MH lamps 240 volts 50 HZ AC Supply complete all as directed. Make :- Havells / CG / Philips.
M&L for sub main wiring on steel tubular pole / PCC pole including fixing with suitable size nylon straps with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 1.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit including flexible PVC pipe at starting and finishing point after and including taking down / dismantling old sub main wiring including old conduit etc of any description complete all as specified and as directed. NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire and one run of PVC rigid non metallic conduit shall be measured as one length. Make:- Plaza / Havells / Polycab / FINOLEX.
Dismantling and taking out the old metallic rusted serviceable junction box painting with two coats of synthetic enamel paint over existing steel surface after making surface and refixing the same on pole including fixing fasteners and refreshing the cable ends after removing of loop cable from trench including earth work etc complete all as directed.
Supply and fixing cable glands 10 sqmm complete all as directed.
Supply and fixing cable glands 16 sqmm complete all as directed.
Supply and fixing cable glands 25 sqmm complete all as directed.
Supply and fixing cable glands 35 sqmm complete all as directed by Engr In Charge.
Boring of hole horizontally 80 mm dia for under road/hard standing area / foot path for laying/crossing of cables including making good road/hard standing area/foot path and road shoulder etc all as specified and as directed.
Laying only for existing cable cover laid in trenches with equal to length of cable across the cable for cable protection all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 meter wide and not exc. 1.5 meter in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed.
Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
Supply and laying in replacement for 10 sqmm one twin core flat or circular 1100 volt grade heavy duty cable insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed. Make:- Havells / POLYCAB / PLAZA.
Supply and fixing in replacement on existing pole LED landscape lights 35 watt new generation post top energy saving environmental friendly long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaries with high power LEDs as light source suitable for mounting on 76mm dia pole. Make : Havells model RUBY (CLEAR) - IP65 cat part No - RUBYPT35WLED757PSYMTOPC or equivalent in CG/Philips.
Supply and fixing in replacement on existing pole LED landscape lights 35 watt new generation post top energy saving environmental friendly long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaries with high power LEDs as light source suitable for mounting on 76mm dia pole. Make :Havells model CORAL (OPAL) - IP65 cat part No - CORALPT35WLED757PSYMTOPC or equivalent in CG/Philips.
Supply and fix in replacement street light panel outdoor type digital 24 hour timer consisting of 65 amps tripple pole contactor and MCB TPN 63 amps including Auto/Manual facility complete all as directed. Make : Havells SAP code IHXTS09120 or equivalent in CG/L&T.
Supply and fix in replacement Pneumatic timer block suitable for controlling power contactor for street light operation complete all as specified and as directed.
Supply and fix in replacement 3 pole power contractor 415 volts 50 HZ AC supply 95 amps for street light operation complete all as specified and as directed.
M/S. SRI RAMANUJA CONSTRUCTIONS
S Mohan
kcs builders
N Rathinam
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .