Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.9 LAccepted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per tender terms and conditions. | |
| 2 | L2₹64.2 L+₹8.3 L (14.9%)Accepted-Finance | L2 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per tender terms and conditions. | |
| 3 | L3₹67.3 L+₹11.4 L (20.5%)Accepted-Finance B 2 46 SECTOR 18 ROHINI DELHI 110089 | NORTH WEST | DELHI | 110089 | L3 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per tender terms and conditions. | |
| 4 | L4₹70.8 L+₹14.9 L (26.7%)Accepted-Finance | L4 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per tender terms and conditions. | |
| 5 | L5₹73.1 L+₹17.2 L (30.8%)Accepted-Finance | L5 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per tender terms and conditions. |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
19 Aug 2019, 4:00 pmClosed
MANAGER - ADMIN
KNOWLEDGE CITY SECTOR 81 MOHALI
AMC OF HVAC WORKS
2019_NABI_490191_1
NABI/7(191)/2019-Works
Open Tender
AMC/ Maintenance Contracts
Item Rate
365 days
NABI CAMPUS
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
NABI
₹1.8 L
Yes
21 Dec 2020
29 Jul 2019
20 Aug 2019
29 Jul 2019
19 Aug 2019
29 Jul 2019
Annual Operation & Maintenance cost of HVAC system of NABI as per the scope of work defined in Schedule-A of Volume-1 of tender document
Annual Operation & Maintenance cost of HVAC system of CIAB as per the scope of work defined in Schedule-A of Volume-1 of tender document
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 500mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 450mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 300mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 250mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 200mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 150mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 125mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 100mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 80mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 65mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 50mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 40mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 32mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 25mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 20mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) Pipes, cables etc, not exceeding 80 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre)
SPAN ENGINEERS
Aircon Technique Pvt Ltd
CHILL POINT ENGINEERS PVT LTD
PAN POLAR ENGINEERS PVT. LTD.
Agile Engineers
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .