Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | ₹22.7 L Quoted ₹24.0 L | L1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L2₹24.5 LRejected-Finance | ₹24.5 L | L2 | Rejected-Finance Over all rates are higher than L-1. |
| 3 | L3₹25.4 LRejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | ₹25.4 L | L3 | Rejected-Finance Over all rates are higher than L-1. |
| 4 | L4₹27.9 LRejected-Finance | ₹27.9 L | L4 | Rejected-Finance Over all rates are higher than L-1. |
| 5 | L5₹29.8 LRejected-Finance | ₹29.8 L | L5 | Rejected-Finance Over all rates are higher than L-1. |
| Sl No | Description | Qty | Unit | Ishtiaq and Sons L5 | S S ELECTRICALS L3 | D K THUKRAL AND SONS L1 | PRATEEK ENTERPRISES L4 | ROYAL ELECTRICAL ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, commissioning and testing of outdoor type LT feedar pillar box, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 900 mm x 600 mm x 400 mm, CPRI approved with front and back openable door (with locking arrangement), duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), incoming connection to be made with copper lugs and copper strips, with provision of 04 No's cable entry and exit at mid portion of the feedar pillar box (with cable gland), and one numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 40 x 40 x 6 mm with 600mm legs with PCC incl taking down old unserviceable feedar pillar box complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- | 2 | Each | 1,60,000 ₹3.2 L | 39,000 ₹78,000 | 45,000 ₹90,000 | 30,000 ₹60,000 | 50,000 ₹1 L |
| 2.00(a) MCCB with thermal-magnetic release of capacity 250 Amp, FP, 50 Hz, 36 KA with spreader terminals-01 No(I/C) (b) Digital Amp Meter with selector switch -1 No (c) Digital Volt Meter with selector switch -1 No (d) LED type indication lamp RYB-1 set.(set of 03) (e) MCB SP 6 Amps, 10KA for Contrillong - 03 No's (f) CT's 400/5A - 03 No's | ||||||||
| 3.00 | Supply, install, commissioning and testing of outdoor type LT feedar pillar box, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 900 mm x 600 mm x 400 mm, CPRI approved with front and back openable door (with locking arrangement), duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), incoming connection to be made with copper lugs and copper strips, with provision of 04 No's cable entry and exit at mid portion of the feedar pillar box (with cable gland), and one numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 40 x 40 x 6 mm with 600mm legs with PCC incl taking down old unserviceable feedar pillar box complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- | 2 | Each | 80,000 ₹1.6 L | 32,000 ₹64,000 | 41,000 ₹82,000 | 30,000 ₹60,000 | 46,000 ₹92,000 |
| 4.00(a) MCCB with thermal-magnetic release of capacity 160 Amp, FP, 50 Hz, 36 KA with spreader terminals-01 No(I/C) (b) Digital Amp Meter with selector switch -1 No (c) Digital Volt Meter with selector switch -1 No (d) LED type indication lamp RYB-1 set.(set of 03) (e) MCB SP 6 Amps, 10KA for Contrillong - 03 No's (f) CT's 400/5A - 03 No's | ||||||||
| 5.00 | Supply, install, commissioning and testing of outdoor type LT feedar pillar box without MCCB, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 600 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement), duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), incoming connection to be made with copper lugs and copper strips, with provision of 04 No's cable entry and exit at mid portion of the feedar pillar box (with cable gland), and one numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 40 x 40 x 6 mm with 600mm legs with PCC incl taking down old unserviceable feedar pillar box complete all as specified and directed by the Engr-in-Charge. | 3 | Each | 16,000 ₹48,000 | 19,000 ₹57,000 | 15,500 ₹46,500 | 14,000 ₹42,000 | 14,000 ₹42,000 |
| 6.00 | Dismantling carefully serviceable isolating LT Panel board of sizes 1500mm x 900 mm x 600 mm to 2500 mm x 2000mm x 900 mm, duly unscrewing/ opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts incomming and outgoing terninals including cleaning the all switchgear/ accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface complete testing the Panel board till satisfaction of Engr-in-Charge, complete all as specified and directed.
Note : (i) Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate.
(ii) Quantity of Stainless steel hignes as per site requirement shall be deemed to be included in the quoted rate.
(iii) Cost of Aluminium/Copper bus bar, indicator lamp, selector switch, Ammeter & Voltmeter measured and paid seperately. | 30 | Each Job | 2,000 ₹60,000 | 2,900 ₹87,000 | 750 ₹22,500 | 1,800 ₹54,000 | 1,000 ₹30,000 |
| 7.00 | Dismantling carefully serviceable isolating LT Panel board complete of sizes 500mm x 500 mm x 500 mm to 1400 mm x 1000 mm x 600 mm duly unscrewing/ opening front and back cover carefully and cleaning complete bus bar chamber, tightening all the nuts, bolts incomming and outgoing terninals, cleaning the all switchgear/ accessories and replacement of cable glands and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl and applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface, complete testing the Panel board till satisfacation of Engr-in-Charge, complete all as specified and directed.
Note : (i) Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate.
(ii) Quantity of Stainless steel hignes as per site requirement shall be deemed to be included in the quoted rate.
(iii) Cost of Aluminium/Copper bus bar, indicator lamp, selector switch, Ammeter & Voltmeter measured and paid seperately. | 25 | Each Job | 3,000 ₹75,000 | 1,499 ₹37,475 | 500 ₹12,500 | 1,500 ₹37,500 | 1,000 ₹25,000 |
| 8.00 | M&L in repairs for Aluminium bus bar of Size 50 x 6mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed. | 50 | RM | 200 ₹10,000 | 300 ₹15,000 | 50 ₹2,500 | 400 ₹20,000 | 50 ₹2,500 |
| 9.00 | M&L in repairs for Copper bus bar of Size 25 x 4mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed. | 25 | RM | 400 ₹10,000 | 400 ₹10,000 | 100 ₹2,500 | 950 ₹23,750 | 320 ₹8,000 |
| 10.00 | M&L in repairs of LED indicator lamp (R,Y,B,G) including taking down old Unserviceable indicator lamps complete all as specified and directed. | 42 | Each | 50 ₹2,100 | 100 ₹4,200 | 40 ₹1,680 | 75 ₹3,150 | 15 ₹630 |
Updated dates
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Dec 2025, 6:00 pmClosed
GE (WEST) BAREILLY
GE WEST BAREILLY
REPAIR/MAINT OF LT SWITCH GEAR AND CONTROL PANELS AND CONNECTING WORKS OF WEST AREA UNDER GE (W) BAREILLY.
2025_MES_742062_1
8294/C/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (WEST) BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) BAREILLY
₹60,000
Yes
30 Jan 2026
28 Nov 2025
27 Dec 2025
28 Nov 2025
25 Dec 2025
13 Dec 2025
Amount
Supply, install, commissioning and testing of outdoor type LT feedar pillar box, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 900 mm x 600 mm x 400 mm, CPRI approved with front and back openable door (with locking arrangement), duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), incoming connection to be made with copper lugs and copper strips, with provision of 04 No's cable entry and exit at mid portion of the feedar pillar box (with cable gland), and one numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 40 x 40 x 6 mm with 600mm legs with PCC incl taking down old unserviceable feedar pillar box complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-
Supply, install, commissioning and testing of outdoor type LT feedar pillar box, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 900 mm x 600 mm x 400 mm, CPRI approved with front and back openable door (with locking arrangement), duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), incoming connection to be made with copper lugs and copper strips, with provision of 04 No's cable entry and exit at mid portion of the feedar pillar box (with cable gland), and one numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 40 x 40 x 6 mm with 600mm legs with PCC incl taking down old unserviceable feedar pillar box complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-
Supply, install, commissioning and testing of outdoor type LT feedar pillar box without MCCB, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 600 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement), duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), incoming connection to be made with copper lugs and copper strips, with provision of 04 No's cable entry and exit at mid portion of the feedar pillar box (with cable gland), and one numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 40 x 40 x 6 mm with 600mm legs with PCC incl taking down old unserviceable feedar pillar box complete all as specified and directed by the Engr-in-Charge.
M&L in repairs for Aluminium bus bar of Size 50 x 6mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed.
M&L in repairs for Copper bus bar of Size 25 x 4mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed.
M&L in repairs of LED indicator lamp (R,Y,B,G) including taking down old Unserviceable indicator lamps complete all as specified and directed.
M&L in repairs LED Digital Voltmeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable voltmeter complete all as specified and directed.
M&L in repairs LED Digital Ammeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable Ammeter complete all as specified and directed.
S&F in repair loop-in-loop out box of size 30x20x20cm made out from 3.15 mm thick MS sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 4 Nos aluminium bus bar of size 25mm x 2mm - 04 Nos fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts & washers etc complete all as specified and directed
Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1800 mm x 1500 mm x 500 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Copper bus bar of 1000 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 75 x 75 x 6 mm with 600mm legs with PCC incl taking down old unserviceable LT Panel with switchgears complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-
Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500 mm x 1200 mm x 500 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Copper bus bar of 1000 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 75 x 75 x 6 mm with 600mm legs with PCC incl taking down old unserviceable LT Panel with switchgears complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-
M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 25mm x 4mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair MCCB, 415 Volts, 4 pole, 630 Amps, 50 Hz, 50 KA alongwith spreader terminal with adjustable thermal & magnetic setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge. Make : L&T/Legrand /Indoasian/C&S/Havells Note :- Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
All as per Item Ser No 20 here-in-before but of MCCB 500 Amps 4 pole 50 Hz 415 V, 50 KA
All as per Item Ser No 20 here-in-before but of MCCB 400 Amps 4 pole 50 Hz 415 V, 36 KA
All as per Item Ser No 20 here-in-before but of MCCB 250 Amps 4 pole 50 Hz 415 V, 36 KA
All as per Item Ser No 20 here-in-before but of MCCB 200 Amps 4 pole 50 Hz 415 V, 36 KA
All as per Item Ser No 20 here-in-before but of MCCB 160 Amps 4 pole 50 Hz 415 V, 36 KA
All as per Item Ser No 20 here-in-before but of MCCB 125 Amps 4 pole 50 Hz 415 V, 16 KA
All as per Item Ser No 20 here-in-before but of MCCB 100 Amps 4 pole 50 Hz 415 V, 16 KA
S&F in repair Isolator, 4 pole, 100 Amps, 415 Volts complete all as specified and directed.
S&F in repair Isolator, 4 pole, 63 Amps, 415 Volts complete all as specified and directed.
M& L for repair and over hauling to LT ACB up to 2000 Amp cap by removing out the panels after taking proper electric shut down & disconnectingthe breaker, checking if throughly for the defect & triping system of the ACB and ractifying them, lubricating of moving contact /overhauling af ACB, replacement of wornout minor spare part, like spring washer, lever, nuts & bolts etc reaasembling, re-istalling, testing and commissioning of ACB complete all as specified and direcred by Engr-in- Charge.
M&L in repairs moving arcing contacts and adjust the contact pressure of LT ACB of any make any capacity complete all as specified and direcred by Engr-in- Charge.
M&L in repairs fixed Arcing contact nand adjust the contact pressure of LT ACB of any make any capacity complete all as specified and direcred by Engr-in- Charge.
M&L in repairs main shaft assembly with crank & cam spacer of 1250/1000/800 Amps 3 Pole of LT ACB of existing make & model and testiing for proper operation complete all as specified and directed.
M&L in repairs spring charging gear motor for LT ACB breaker of size 2000/1000/ 800 Amps of existing make & Model and testing for proper operation complete all as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
Relaying of Old brick recovered from item No 30 or during excavation for protection of cable all as specified & directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing of excavated soft/loose soil not exc 50 m & depositing where as directed at a level n.exc 1.5 m above from starting point completed all as specified and directed.
Taking out old defective cable from trenches/ floor/road/wall/pipe/pole /service connections of any size, testing with LT magger, seggregating the serviceable part of cables and store for relaying complete all as specified & directed. Note : Excavation and earth work will be paid and measured separately in relevant item.
Supply and laying of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 240 Sq mm 3.5 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item No 42 here-in-before but 185 Sq mm 3.5 core
All as per Ser item No 42 here-in-before but 150 Sq mm 3.5 core
All as per Ser item No 42 here-in-before but 120 Sq mm 3.5 core
All as per Ser item No 42 here-in-before but 70 Sq mm 3.5 core
All as per Ser item No 42 here-in-before but 25 Sq mm 4 core
Relaying only serviceable LT UG Cable obtained from Srl item No 37 of any size and description including necessary cable lugs. Note :- All relevent items like excavation, earth work etc shall be paid and measured seperately.
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified and directed.
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 100/80 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed. Note :- GI pipe shall be measure and paid separately under respective item.
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.
S&F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
50 mm dia
80 mm dia
100 mm dia
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT/HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note:- (a) Tools & plants including safety measures equipments like belt, ladder & ropes etc shall be arranged by the contractor at own cost.(b) Contractor supervisor will take proper shut down before starting the work and clear it before resuming power supply, however full assistance will be provided by MES Staff.
S&F in repairs electric shock treatment chart of size approx 3ft x 2ft & 6 mm thick plywood with teak wood frame and covered with glass complete all as specified and directed.
S&F in repairs notice board of size approx 4 ft x 3 ft duly fixed with 6 Nos clips for display of instructions with aluminum frame including covered with plastic laminated sheet complete all as specified and directed.
S&F in replacement 1100 volts grade PVC insulated aluminium conductor screened served with inner sheathed in service connection flat twin core cable of size 10 sqmm complete all as specified and directed.
All as per Ser item No 60 here-in-before but 06 sqmm complete all as specified and directed
Supply and fixing in repairs cable twin core PVC insulated and unsheathed multistranded aluminium conductor of size 2.50 Sqmm complete all as specified and directed.
S&F in repair off load change over switch three phase, Four pole with enclosure capacity 400 Amps with side handle operated complete all as specified and directed by Engineer-in-charge.
All as per Ser item No 63 here-in-before but capacity 200 Amps complete all as specified and directed
All as per Ser item No 63 here-in-before but capacity 100 Amps complete all as specified and directed
All as per Ser item No 63 here-in-before but capacity 63 Amps complete all as specified and directed
S&F in repair ON load change over switch three phase, Four pole with enclosure capacity 400 Amps with Front handle operated complete all as specified and directed by Engineer-in-charge.
S & F in repairs ACB 4 pole as per exsting make and specification installed at MH sub station of cap 2000 Amp.complete all as specified and directed.
S & F in repairs ACB 4 pole/ ACB (bus coupler) as per exsting make and specification installed at MH sub station of cap 1000 Amp. 50 KA complete all as specified and directed.
S & F in repairs ACB 4 pole as per exsting make and specification installed at various substation of cap 800 Amp.50 KA complete all as specified and directed.
S&F in replacement Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
10 Sqmm to 16 sqmm 4 core
25 Sqmm to 50 sqmm 3.5/4 core
70 sqmm to 150 sqmm, 3.5 core
185 sqmm to 240 sqmm, 3.5 core
Notes:- (a) Complaints pertaining to LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 1000/- per day per complaint shall be imposed from the contractor. (b) A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (c) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (d) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
ROYAL ELECTRICAL ENTERPRISES (BID ID -3498271)
S S ELECTRICALS (BID ID -3499419)
PRATEEK ENTERPRISES (BID ID -3497324)
Ishtiaq and Sons (BID ID -3501255)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
COMPLETETENDER8294.pdf
Tender Documents • 1.39 MB
BOQ_830954.xls
BOQ • 0.82 MB
Download all tender documents and submit your bid