DSIC and Operation and Maintenance of MGPS at Salt Lake Sub Division Hospital of West Bengal for 1 year
2021_WBMSC_340145_1
WBMSCL/NIT-212/2021, Dated-29/06/2021
Open Tender
MECHANICAL
Item Rate
15 days
Salt Lake Sub Division Hospital at North 24 Pgs.
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹20,000
Bord Roam WBMSCL
14 Dec 2021
13 Aug 2021
7 Sept 2021
13 Aug 2021
6 Sept 2021
18 Aug 2021
14 Aug 2021 - 16 Aug 2021
14 Aug 2021
Amount
OXYGEN SYSTEM
2 x 5 size main manifold complete with middle frame with chain for individual cylinder along with Tail Pipe and Non Return Valve for every cylinder and Isolation Valve, Safety Valve, etc. as required for the complete manifold system
2 cylinder Emergency manifolds complete with middle frame with chain for individual cylinder along with Non Return Valves and tail pipes for every cylinder and with ESAB IOX 14 high flow Oxygen Regulator having non-halogenated polymer at the higher pressure side. In case of reduction of pressure of the main manifold, there should be automatic changeover from main manifold to emergency manifold.
Fully automatic control panel for Oxygen with automatic changeover facilities from running bank to reserve bank of cylinders and vice- versa. Non Return Valve, Isolation Valve, Safety Relief Valve, etc. as required for the complete system
Surface/panel/pendant mounted front loading double lock Oxygen outlets with matching Adapters (BS type) as per standards
Oxygen Flowmeter & Humidifier Bottle with matching Adapter: Back Pressure Compensated Flow meter within a range of 0-15 LPM where 0-5 LPM should be with expanded scale. Humidifier bottle should be made of unbreakable polycarbonate materials and autoclavable at 121 degree Centigrade (to be supplied along with required low pressure tubing and face mask)
Distribution of Copper Pipe
12 mm OD x 0.7 mm thick copper pipe
15 mm OD x 0.9 mm thick copper pipe
22 mm OD x 0.9 mm thick copper pipe
28 mm OD x 0.9 mm thick copper pipe
Isolation Valve
Isolation Valve 15 mm
Isolation Valve 22 mm
Isolation Valve 28 mm
Area Valve Service Unit
3 service Valve Box configuration with size 15 O2, 15 MA4, 22 VAC
Medical Gas Digital Area Alarm System as per standards
1 service alarm configuration for O2
Turnkey - for both Civil & Electrical work wherever necessary
Operation & Comprehensive Maintenance charges
Operation & Comprehensive Maintenance charges for the 1st Year
Bozon Technologies Pvt. Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .