| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted | |
| 2 | L2₹10.4 L+₹41,351 (4.14%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹10.6 L+₹62,889 (6.30%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹10.9 L+₹90,906 (9.10%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹12.6 L+₹2.6 L (26.1%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
10 Jul 2021, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR AND REPLACEMENT OF ELETRICAL WIRING WITH FITTING AND FIXTURES AND SUB MAIN WIRING WITH DBS AND SERVICE CONNECTION WITH EARTHING IN OFFRS MD ACCN MES ACCN CENTRAL INSTITUTE AND MES IB AT MIL STN DHRANGADHRA
2021_MES_453031_1
GE(A)/GNR/TOKEN/50 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹34,000
Yes
10 Aug 2021
19 Jun 2021
12 Jul 2021
19 Jun 2021
10 Jul 2021
27 Jun 2021
19 Jun 2021 - 26 Jun 2021
Amount
Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire connecting with earth dolly and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One light point controlled by two, 2- way switches.
(c) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(d) One multi pin 5 Amps, socket outlet on Independent board.
(e) One bell/ buzzer point controlled by one push buttons independent
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire connecting with earth dolly and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire connecting with earth dolly and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
M&L for wiring with and including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through existing medium grade, rigid non metallic, PVC concealed conduit not less than 20mm bore and including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating in new modular sunken concealed terminal boxes complete all as specified and directed for the following:-Note: S&F modular metal box and white cover plate with frame will be measured and paid separately under respective item.
(a) One light/fan point controlled by one switch
(b) One light point controlled by two, 2- way switches.
(c) One 3 pin, 5 Amps, socket outlet on the same board, controlled by another switch.
(d) One multi pin socket outlet, 5 Amps, on Independent board.
(e) One bell/buzzer point controlled by one push buttons independent.
M&L for wiring with and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number drawing through existing medium grade, rigid non metallic, PVC concealed conduit not less than 25mm bore and including with multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire terminating with earth dolly in new modular sunken concealed terminal boxes for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed. Note: S&F modular metal box and white cover plate with frame will be measured and paid separately under respective item.
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 1.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade,ISI - 694 marked in and including heavy duty,PVC casing caping including all accessories etc.,heavy duty ISI marked ,with PVC ISI marked switch board, including continuous PVC insulated copper earth wire 1.5 Sqmm connected to common earth dolly, complete for the following:- Note:- Making good of disturbed surfaces will be done by contractor without any claims.
(a) One light/fan point controlled by one switch
(b) One light point controlled by two, 2- way switches.
(c) One 3 pin, 5 Amps, socket outlet on the same board, controlled by another switch.
(d) One multi pin socket outlet, 5 Amps, on Independent board.
(e) One bell/buzzer point controlled by one push buttons independent.
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 2.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade,ISI - 694 marked in and including heavy duty,PVC casing caping including all accessories etc.,heavy duty ISI marked ,with PVC ISI marked switch board for one 3 pin, 15 Amps socket outlet point on independent board complete including continuous PVC insulated copper earth wire 2.5 Sqmm connected to common earth dolly , complete for the following:- Note:- Making good of disturbed surfaces will be done by contractor without any claims.
M&L for wiring with and including multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, PVC casing caping incl all accessories with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number as continuity earth wire terminating in new modular sunken concealed terminal boxes complete all as specified and directed for the following:-Note: S&F modular metal box and white cover plate with fame will be measured and paid separately under respective item.
(a) One light/fan point controlled by one switch
(b) One light point controlled by two, 2- way switches.
(c) One 3 pin, 5 Amps, socket outlet on the same board, controlled by another switch.
(d) One multi pin socket outlet, 5 Amps, on Independent board.
(e) One bell/buzzer point controlled by one push buttons independent.
M&L for wiring with and including multi stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number PVC casing caping incl all accessories with multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire terminating in new modular sunken concealed terminal boxes for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed. Note: S&F modular metal box and white cover plate with frame will be measured and paid separately under respective item.
S&F, lamp holder, PVC/Polycarbonate, with back plate suitable for batten fittings complete all as specified and directed
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F, switch flush type 5 Amps, single pole, two ways complete all as specified and directed
S&F , modular switch 1 way 10A, 1 module complete all as specified and directed. As per Cat No. 21011 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F , modular switch 2 way 10A, 1 module complete all as specified and directed.As per Cat No. 21022 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, modular switch 1 way 20A, 1 module complete all as specified and directed. As per Cat No. 21066 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F , modular socket 10A, 2/3 pin combined, 2 module complete all as specified and directed. As per Cat No. 30373 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, modular socket 20A, 2/3 pin combined, 2 module complete all as specified and directed. As per Cat No. 30828 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, bell push, flush type 5 Amps complete all as specified and directed.
S&F, modular bell push 10A, 1 module complete all as specified and directed. As per Cat No. 21044 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, bell, A.C. 230 Volts, single pole, Ding doll, complete all as specified and directed.
S&F, modular fan step type regulator suitable for 1200/1400mm sweep ceiling fan of 2 module complete all as specified and directed. As per Cat No. 22546 of Anchor(Roma) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F , modular white cover plate with frame for 1/2 modules complete all as specified and directed
S&F, modular white cover plate with frame for 3 modules complete all as specified and directed
S&F, modular white cover plate with frame for 4 modules complete all as specified and directed
S&F, modular white cover plate with frame for 6 modules complete all as specified and directed
S&F, modular white cover plate with frame for 8 modules complete all as specified and directed
S&F, modular white cover plate with frame for 12 modules complete all as specified and directed
S&F, modular metal flush box concealed type with 1/2 module for housing modular switches complete all as specified and directed
S&F, modular metal flush box concealed type with 3 module for housing modular switches complete all as specified and directed
S&F, modular metal flush box concealed type with 4 module for housing modular switches complete all as specified and directed
S&F, modular metal flush box concealed type with 6 module for housing modular switches complete all as specified and directed
S&F, modular metal flush box concealed type with 8 module for housing modular switches complete all as specified and directed
S&F, modular metal flush box concealed type with 12 module for housing modular switches complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed
S&F, ceiling fan step type regulator,AC 230 Volts complete all as specified and directed. As per Cat No. 14501 of Anchor(Penta) or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, in repairs, sheet metal enclosures, single pole & neutral with a two pin & earth plug and socket complete with one single pole, MCB of 20 Amps, 10 KA, 240 volts complete all as specified and directed
S&F, in repairs, sheet metal distribution board, SPN, 12 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, in repairs, sheet metal distribution board, SPN, 8 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, in repairs, sheet metal distribution board, SPN, 4 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, in repairs, sheet metal distribution board, single door, factory made and tested complete, suitable for mounting MCBs, isolator of capacity 2 way 240 Volt complete all as specified and directed
S&F, in repairs, sheet metal distribution board, 3 phase with neutral ( TPN ) of 4 way 415 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, in repair, miniature circuit breakers, Three pole type curve‘C’ 10KA, 63 Amps, 415Volts. complete all as specified and directed.
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, in repairs, miniature circuit breakers, type curve ‘B’ , 10 KA, SP, 6 to 32 Amps complete all as specified and directed.
S&F, in repairs, miniature circuit breakers, Single pole and neutral, type curve ‘C’ 10KA, 32 Amps 230 Volts. complete all as specified and directed.
S&F, in repair, miniature circuit breakers, Single pole and neutral, type curve ‘C’ 10KA, 40 Amps 230 Volts. complete all as specified and directed.
S&F, in repair, miniature circuit breakers, Three pole and neutral, type curve‘C’ 10KA, 40 Amps, 415Volts. complete all as specified and directed.
S&F, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 32mm size including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4.0 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length
S&F, in repairs, sub-main wiring with 4 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 32mm size including drawing 2 run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 44.0 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 4 runs of main conductor, two run of earth conductor and one run of PVC casing and caping shall be measured as one unit length.
S&F, in repairs, LED light fitting, batten type, housed in extruded from powder coated aluminium, 18 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed. Make: As per Cat No. BAJAJ LED BATTEN 18W (Item Code 830101) of Bajaj or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, in repairs, LED light fitting, batten type, housed in extruded from powder coated aluminium, 9 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed. Make: As per Cat No. BAJAJ LED BATTEN 9W (Item Code 830102) of Bajaj or equivalent make approved by GE from the make specified in Appx 'C'.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
Labour for attending of defects for checking of existing electrical items such as light fittings, DBs, switch boards, panel boards, for continuous electric supply ,no light including carrying out minor repairs etc as required to make the item functional and replacing fuse, small pieces of wire etc all as specified. Note: 1. Four complaints will be measured as one unit. 2. New material required to be fixed against old worn out, shall be measured and paid separately.
M & L repair for Sub main wiring complete with four single core 6 sqmm and one core of 6.0 sq.mm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims. Note :- 4 runs of 6 Sqmm conductor and one run of 6 Sqmm earth wire shall be measured as one unit length.)
S & F in replacement of decorative wall light fixture made up of polycarbonate suitable for 9W LED Lamp B22 base on Havells cat part no LHFOFWE1TZ1W012 or equvalent to wipro,cropton,bajaj complete all as specified and directed.
M & L in replacement of Sub main wiring complete with two single core 6 sqmm ,1100volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 6 sqmm in and including PVC casing caping complete all as directed by Engineer-in-Charge Note:- Making good of disturbed surfaces will be done by contractor without any claims. (Note :- 2 runs of 6 Sqmm conductor and one run of 6 Sqmm earth wire shall be measured as one unit length.)
S&F in replacement of building security light luminaries 25 watt with wall mounting bracket of suitable size and clamps, nut bolts etc.having pressure die cast housing with epoxy power coated dark graphite grey colour finish,prismatic polycarbonate cover with individual LED lenses-IP65 prewired Conforming to Crompton Cat Part No. LSTO-25-CDL or of equivalent make of wipro/Havells/Philips wipro LR02-291-xxx-57-xx
S & F, in repair, Distribution Board Power line VTPN, 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including 3 pole MCCB 63 Amps rating, 10KA breaking capacity for incoming supply and provision of MCB SP/TP for out going supply complete all as specified and directed. As per Cat No DSDLVDRBAOFO04 of Standard or equivalent
S & F Ellipse Neo Round head LED light fittng 6W IP65 Water proof heavy aluminium body wall/ceiling mounted complete with all accessories and including connection up with twin core flexible copper conductor cable with suitable size complete as all specified and directed. Make of Havells/Wipro/bajaj or equivalent makes.
Earth continuity conductor or mainearthing lead fixed to wall on battenor recess or chases or buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. asrequired 4 mm dia galvanised iron orsteel wire
S & F LED 24 watt recess mounting 2 x 2 luminaire of 24 watt, white powder coated CRCA housing with highpower LEDs. Aluminium front frame with flat white high transmission acrylic cover prewired and all accessories Make: Wipro , cat pt CRCO110R024HP57TLG2 or equivalent in Havells/philiphs
S & F in replacement of round cessed mounted 6 watt LED slim down light with die -cast aluminum housing finshed in premium white powder coating with robust electronics for erratic power conditions of white/neutral white color temperature etc, prewired and all accessories Cat part No. LHEBMCP7IW1W006 of Havells/Wipro/Crompton/Philips complete all as directed by Engr-in-Charge.
S & F in replacement of decorative box type LED light fitting, 1 x 20 Watt, 230 V,C surfacce mounting white powder coated CRCA sheet steel housing with crescent light opening in a perforated metallic frame complete with 20 W LED tube complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed by Engr-in-charge. Make- Crompton Cat Part No. DMLN1LT8-16 AND LTT8-20 or equivalent in Wipro,/philiphs/Havells
ALBA AC AND REF SERVICES
Abhishek Enterprises
Electricals India
Electromech Engineers
M/S VENUS BUILDER
CENTAUR ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .