Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.8 CrAccepted-Finance | ₹92.8 Cr | L1 | Accepted-Finance The work is awarded to the L1 bidder |
| 2 | L2₹96.4 CrRejected-Finance | ₹96.4 Cr | L2 | Rejected-Finance The work is awarded to the L1 bidder. |
| 3 | L3₹110.5 CrRejected-Finance PLAT NO 943 54TH STREET T V S COLONY ANNANAGAR WEST EXTENSION CHENNAI PIN 600 101 | CHENNAI | CHENNAI | TAMIL NADU | 600101 | ₹110.5 Cr | L3 | Rejected-Finance The work is awarded to the L1 bidder. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | Koya and Company Construction Limited L2 | Eco Protection Engineers Private Limited L3 | Everest Infra Ventures India Pvt Limited L1 |
|---|---|---|---|---|---|---|
| 1.00App.A-Components of Treatment plant-40MLD | ||||||
| 1.00 | OD236171/2023-2024:Design, Construction & Commissioning of Aerator for a 40MLD Water
Treatment Plant as per the site condition and as per the direction of Dept officers etc
complete | 1 | no | 20,91,999 ₹20.9 L | 25,00,000 ₹25 L | 18,60,170 ₹18.6 L |
| 1.00 | OD236347/2023-2024:Design, Construction & Commissioning of Raw water channel for 40MLD
Water Treatment Plant as per the site condition and as per the direction of Dept
officers etc complete | 1 | no | 19,82,367 ₹19.8 L | 23,00,000 ₹23 L | 17,62,687 ₹17.6 L |
| 1.00 | OD236371/2023-2024:Design, Construction & Commissioning of Flash mixer,for a 40MLD Water Treatment Plant as per
the site condition and as per the direction of Dept officers etc complete | 1 | no | 4,38,478 ₹4.4 L | 5,00,000 ₹5 L | 3,89,887 ₹3.9 L |
| 1.00 | OD236396/2023-2024:Design, Construction & Commissioning of chemical house for a 40MLD Water Treatment Plant as per
the site condition and as per the direction of Dept officers etc complete | 1 | no | 1,82,84,607 ₹1.8 Cr | 2,11,00,000 ₹2.1 Cr | 1,62,58,358 ₹1.6 Cr |
| 1.00 | OD236412/2023-2024:Design, Construction & Commissioning of Alum and Lime solution tank for a 40MLD Water Treatment Plant as per
the site condition and as per the direction of Dept officers etc complete | 1 | no | 4,58,195 ₹4.6 L | 5,25,000 ₹5.3 L | 4,07,419 ₹4.1 L |
| 1.01 | OD236424/2023-2024:Design, Construction & Commissioning of chlorine storage room for a 40MLD Water Treatment Plant as per
the site condition and as per the direction of Dept officers etc complete | 1 | no | 31,25,470 ₹31.3 L | 36,00,000 ₹36 L | 27,79,114 ₹27.8 L |
| 1.01 | OD236442/2023-2024:Design, Construction & Commissioning of flocculation basin with Vertical paddles for a 40MLD Water Treatment Plant as per
the site condition and as per the direction of Dept officers etc complete8 | 1 | no | 2,83,71,188 ₹2.8 Cr | 3,27,00,000 ₹3.3 Cr | 2,52,27,171 ₹2.5 Cr |
| 1.01 | OD236592/2023-2024:Design, Construction & Commissioning of Clarifloculator (Parallel plate clarifier) for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete8 | 1 | no | 1,43,23,977 ₹1.4 Cr | 1,65,00,000 ₹1.6 Cr | 1,27,36,634 ₹1.3 Cr |
| 1.01 | OD236604/2023-2024:Design, Construction and Commissioning of Filter bed for a 40MLD Water Treatment Plant as per
the site condition and as per the direction of Dept officers etc complete. | 1 | no | 61,97,623 ₹62.0 L | 71,50,000 ₹71.5 L | 55,10,820 ₹55.1 L |
Tender Value
₹88.4 Cr
EMD Value
₹5 L
Closing Date
9 Aug 2024, 2:00 pmClosed
The Superintending Engineer, KWA, PH Circle, Thiru
Office of the Superintending Engineer, KWA, PH Circle, Thiruvalla, Pathanamthitta
JJM-CWSS to Koipuram and adjoining pts.-Design and construction of 12 m dia intake well cum pump house at poovathoor kadavu,40 MLD WTP,800 mm DI K9 RWPM,CWPM,Supply and erection of RW pumpsets, Transformers, GLSR/OHSR including road restoration etc.
2024_KWA_682599_1
14/2024 -25/KWA/PHC/TVLA
Open Tender
Civil Works - Water Works
547 days
Koipuram
As per NIT conditions, submitted Tender Documents and Q1 to Q8
7 documents required · 7 mandatory
₹19,518
₹5 L
Office of the Superintending Engineer, KWA, PH Cir
26 Sept 2025
26 Jul 2024
12 Aug 2024
26 Jul 2024
9 Aug 2024
26 Jul 2024
26 Jul 2024 - 9 Aug 2024
27 Jul 2024
Amount
App.A-Components of Treatment plant-40MLD
OD236171/2023-2024:Design, Construction & Commissioning of Aerator for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD236347/2023-2024:Design, Construction & Commissioning of Raw water channel for 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD236371/2023-2024:Design, Construction & Commissioning of Flash mixer,for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD236396/2023-2024:Design, Construction & Commissioning of chemical house for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD236412/2023-2024:Design, Construction & Commissioning of Alum and Lime solution tank for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD236424/2023-2024:Design, Construction & Commissioning of chlorine storage room for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD236442/2023-2024:Design, Construction & Commissioning of flocculation basin with Vertical paddles for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete8
OD236592/2023-2024:Design, Construction & Commissioning of Clarifloculator (Parallel plate clarifier) for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete8
OD236604/2023-2024:Design, Construction and Commissioning of Filter bed for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete.
OD236689/2023-2024:Design, Construction and Commissioning of water channel to filter bed-Clear water channel for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete.
OD236691/2023-2024:Design, Construction and Commissioning of Wash Water Tank for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept. officers etc complete.
OD236693/2023-2024:Design, Construction and Commissioning of Filter House and Clear Water Pump House for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept. officers etc complete.
OD236695/2023-2024:Design, Construction and Commissioning of Clear Water Sump , Holding and Settling Tank for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept. officers etc complete.
App.-A(1)-Associate components of Treatment Plant
OD236698/2023-2024:Supply and providing water supply and sanitary arrangements, sludge pits and disposal arrangements as per design
OD236699/2023-2024:A well-equipped laboratory for physical, chemical, and Bacteriological tests as per WHO/CPHEEO manual shall be provided in the filter house/chemical house office building .the arrangements of testing equipment as mentioned below, : DigitalTurbiditymeter, DigitalpHmeter, Conductivitymeter, Photoelectricchloroscope, Bacteriologicaltest kit, Jar test apparatus(minimumof4jars), Electronicbalance(toweighupto1mg), Autoclave, Incubator, Refrigerator, Distilledwaterplant, Chlorine test kit, Gasmask, PHkit, Hot plate, Mufflefurnace, Electricoven, Centrifuge, Magneticstirrer, GasCylinder, FumeCupboard, Electronic weighing balance,minimum number of glass wares of standard manufacturers and other requirements for testing shall be supplied and completed as per the direction of departmental officials: Testtube (12), Conical flask(standard size) (6), Standard flask (6), Pipette (3),100mlStandardbottle(10), Glassrod (6),Spatula (2), Porcelain dish (2).etc. complete as per direction of departmental officials.
OD236864/2023-2024:Design, Construction and Commissioning of Mechanical Items for a 40MLD Water treatment Plant including providing and fixing 304 stainless steel lamella plates and support structures as per the site condition and as per the direction of Departmental officers etc complete. This shall include supply installation, testing, Trial run, commissioning of all mechanical item for which no separate provision has been made in the tender schedule( Not specifically mentioned in the estimate)
OD236891/2023-2024:supply, installation, testing, and commissioning of electrical items like wiring materials, ,wiring with sufficient number of Light , Fan, plug pints of light and Power, Yard lighting works as directed by departmental officers, Providing and fixing all fixtures including Ceiling Fan, Exhaust Fan, Pedestal Fan, wall mounted Fan and LED Lights of good quality wherever necessary and all other electrical works & mechanical works, CCTV works for all the areas in the WTP & outside,All safety works and items as per the standards of Electrical Inspectorate, Air conditioner of required capacity for SCADA, yard lighting, lightning arrester as per IS specification, all safety equipment etc complete as per latest IE rules as per directions of departmental officers.items approved by Kerala Electrical Inspectorate, , lightning arresters, and drawings for the electrical inspectorate.(All the work must be in accordance with Electrical Inspectorate standards.) , and all other electrical works for the satisfactory completion of the electrical works.All paper and allied works with Electrical inspectorate for approval and to be got approved by Electrical Inspectorate All the other cable works related to Electrical works, Supply and works of required Earthing, All paper and allied works with the Electrical inspectorate for approval and to be got approved by Electrical Inspectorate and all related mechanical works
OD236899/2023-2024:PLC - SCADA Automation design, Engineering, procurement, installation, training and trail run-.SCADA system for the entire unit(WTP , )with actuators for various valves,cables, supply & fixing of actuator type valves for WTP, supply of sensors, computer,Air conditioner unit,water level indicators computers, PH meter, turbidity meter,all type meter for WTP and intake , digital flow meters , monitoring of all the parameters during operation of the plant, supply of electrical & PLC control panels and SCADA,supply of cables,PLC SCADA programming & development charges,cabling charges etc including all works of automation of the WET and other connected componets
OD236926/2023-2024:CCTV ( Cameras) with all equipment, DVR (30 days backup) etc. complete as per directions. - CCTV -Covering the whole of new WTP including FH, Chemical House, Pump houses, Chlorine room, pipe gallery, recycling unit, office block, SCADA room, and substation, in and out of WTP compound covering whole area with 1.NVR - CP Plus 64 Channel 8 Sata NVR 320 Mbps Upto 4K Support Model LCP-UNR- 4K564R8(all connected items for the satisfactory completion of work).<br><br>2. Bullet Camera - CP Plus Full HD IP Camera-5MP 1080p 6 mm 80 Meter (For Front Gate View/In and Out)Model:CP UNC TA21L8.- 2Nos<br>3. Bullet Camera - CP Plus Full HD IP Camera-5MP 1080p body 3.6mm 30 Meter Model: CP UNC TA21PL3-28Nos.<br>4. Dome Camera - CP Plus Full HD IP Camera Dome-5MP 1080p for Office Building and Computer Room Model:CP UNC DA21PL3- 5Nos.<br>5. 6 TB HDD - 6 TB WD Purple Surveillance HDD(Approx 30 Days Backup for Motion Detection H265 Data Storage for 16 Cameras per NVR?4Nos<br>6- 43 Inch Full HD Android TV VU/TCL -1Nos<br>7-Supply and installation of 24 port L2 Manager Switch having 24 Numbers 10/100/1000 Compo port?1Nos<br>8-Supply and installation of 42 Urack with accessories-1Nos <br>9-Cp Plus 8+2 Part Poe 10/100/1000 2 Gigabyte UP link Port-5Nos<br>10-Bullet Camera 5MP Outdoor Housing with Stand-10Nos <br>11-CP Plus 4 Part POE Switch:4+2 Part Gigabyte Up link Transmission 10/100/1000 Mbps-2Nos <br>12-CP Plus 8+2 Port Poe 2 SEP port Switch 10/100/1000)Water pumping Area)-2Nos .etc all connected items for the completion of work as per the direction of departmental officers on the basis of details of data analysis
OD237048/2023-2024:Supplying, installing, testing, trial run and commissioning 6 KVA or more capacity inverter with 8 hours back for yard light, office accessories etc as per directions of deptl: Officers.
OD237126/2023-2024:Design, Construction and Commissioning of indoor transformer room near WTP site for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete
OD246027/2023-2024:Supply and laying 900mm DI K9 clear water pumping main from clear water pump house to balancing OHSR at WT plant site including cost of materials and labour charges etc,complete as per the direction of departmental officers in charge.
OD246026/2023-2024:Supply of DI K9 Pipe , 900mm Dia. and providing and laying D.I specials of class K - 12 suitable for jointing as per the direction of departmental officers etc,complete.
App-A(2)-Construction of Recycling tank
OD237157/2023-2024:Design, Construction and Commissioning of Recycling tank for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete.
OD237166/2023-2024:Interconnection works to Aerator with Recycling tank and scour to recycling tank for a 40MLD Water Treatment Plant as per the site condition and as per the direction of Dept officers etc complete.
App-A(3)-Providing and fixing concrete tiles and landscaping on yard & Construction of concrete road and Drainage
16.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
OD271974/2023-2024:Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler Detail of Cost for 100 sqm Neel giri/maxican grass turf = 100 sqm Add 15% wastage = 15 Sqm Total = 115 Sqm
OD271976/2023-2024:Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of serviceable material?s as per direction of officer in charge( including cast of plant & water )<br>Cost of plantation per trees plants.as per the direction of departmental officers
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
16.1:Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
App-A(4)-Construction of Compound wall
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.40:Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:
OD246207/2023-2024:Providing MS gates for compound wall using 40mm GI pipe for frame work and inside of this framemaking grills using 10mm square rod, 100mm C/C on both sides and the vertical rod extented from thetop frame upto required length as per drawing and painting epoxy paint two coats for approved colourafter painting zinc rich priming coat after rubbing with emery paper and cleaning the surface andarranging the locking system including cost of materials and labour and hire charges for fabricating etc.complete as per the direction of deptl. Officers
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
OD270028/2023-2024:Design charges for Structural and Architectural (CD with Color Print 5 Copy)
App-A(5)-Site clearing and levelling work
OD236077/2023-2024:Ground leveling and site clearing,excess earth cutting ,Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings,Landscaping, gardening, construction of drains etc.as per the direction of departmental officers
App-A(6)-Operation and Maintenance
OD272029/2023-2024:Operator
OD272032/2023-2024:Shift Assistant
OD273396/2023-2024:Security guard.
OD273394/2023-2024:Engaging Electrician
OD273395/2023-2024:Engaging Process Chemist to ensure water quality by testing raw & treated water and thereby fixing dosage of chemicals etc
OD273397/2023-2024:Mechanic
OD273398/2023-2024:Gardener
OD272044/2023-2024:Sweeper Part Time
OD272047/2023-2024:Supply and delivery of Hydrated lime as per specification
OD272048/2023-2024:Supply and delivery of Class IV Alum -With relevant IS specifications
OD272051/2023-2024:Chlorine tonner filling from TCL(transporting, filing cost , loading unloading etc.)-Refilling charges of empty Chlorine cylinders including transportation of empty Chlorine cylinders from WTP to TCL Kochi including all loading and unloading charges, transportation charges,etc. complete including cost of Chlorine gas as per the direction of the department officers
App-A(7) Office Furniture
OD237320/2023-2024:Supply of steel Almarah of min. size 135cm x 90cm x 50cm 20 gauge or nearest size,Chair and Steel table inside the lab with shutters, lock and key arrangements shall be made up of mild steel, powder coated of reputed companies like Godrej, Allwyn, etc as per direction of departmental officials.
App-A(8)-Raw Water Pumpset
App-A(9) Clear Water Pumpsets
App.-A(10)-CWPM From CWPH to OHSR at WTP-Working Charges
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.1.9:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock Requiring Blasting.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.14.14:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 900mm diameter Ductile Iron Class K-9 Pipes.
100.35.14:Testing 900mm DI/CI pipeline with potable water to the required test pressure. 900 mm dia Observed Data derived from item no.1033 of PHED DATA
100.37.18.1:In situ fabrication of M.S. pipes of size 900mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.18.2:Fabricating M.S. flanges of diameter 900mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.70.14:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:900 mm dia pipes
100.37.18.3:Cutting 900mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.18.4:Welding 900mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.18.5:Grinding cut and weld edges of 900mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.68.2:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Above 600 mm dia
18.69.2:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Above 600 mm dia
4.2.2:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3 (1 cement : 11/2 coarse sand :3 graded stone aggregate 20 mm nominal size)
100.19.4:Providing flanged joints to double flanged CI/DI pipes and specials, including testing of joints: 900mm Diameter Pipe.
100.22.4:Labour for cutting C.I. pipe with steel saw: 900mm diameter C.I. pipe.
App.-A(11)-CWPM From CWPH to OHSR at WTP-Cost of Materials
100.98.128:Supply of DI K9 Pipe Conforming to IS 8329/2000, 900mm Dia.
Appendix: B --Construction of 12m dia intake well
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
OD255407/2023-2024:Putting up bund across a river, thodu etc. to a height of 6.25m from the bed and average width of 2.2 to 3.00 M (Average 2.6 metre) using coconut post half splitted coconut horizontals 50cm C/C through out both side and tying with coir yarn and G.I. wire rope as struts at 1.50M intervals to either side and laying coconut cadjanmadal screening including providing cocanut horizontal pieces at both sides (screen 1/3rd split) and filling puddle clay filled bag filling and dismantling the ring bund, after completion of the work, including removing of coconut piles, cadjans madals screen, sand filled bags, puddle clay using necessary equipments such as country boat, Jet pumps etc. including labour charges asper the direction of (Observed data for 16.50)
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
OD255413/2023-2024:Sinking well of 12 m dia inside and depth up to 3.00 m below spring level in all classes of soil to lines and levels and plumb by scooping out earth from inside and below the steining using necessary appliances including hire and labour for the same including dumping the spoil beyond the initial lead of 50 m etc. complete.
OD255412/2023-2024:Sinking well of 12 m dia inside and depth from 3.00 m below spring level and up to 6 m in all classes of soil to lines and levels and plumb by scooping out earth from inside and below the steining using necessary appliances including hire and labour for the same including dumping the spoil beyond the initial lead of 50 m etc. complete.
OD255411/2023-2024:Sinking well of 12 m dia inside and depth from 6.00 m below spring level and up to 9 m in all classes of soil to lines and levels and plumb by scooping out earth from inside and below the steining using necessary appliances including hire and labour for the same including dumping the spoil beyond the initial lead of 50 m etc. complete.
OD255410/2023-2024:Sinking well of 12 m dia inside and depth from 9.00 m below spring level and up to 10.5 m in all classes of soil to lines and levels and plumb by scooping out earth from inside and below the steining using necessary appliances including hire and labour for the same including dumping the spoil beyond the initial lead of 50 m etc. complete.
OD255409/2023-2024:Sinking well of 12 m dia inside and depth from 10.5 m below spring level and up to 13.5 m in all classes of soil to lines and levels and plumb by scooping out earth from inside and below the steining using necessary appliances including hire and labour for the same including dumping the spoil beyond the initial lead of 50 m etc. complete.
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.15:Extra for laying concrete in or under water and or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. Note for item No. 4.15 : - The quantity will be calculated by multiplying the depth measured from the sub-soil water level upto centre of gravity of concrete under sub-soil water level with quantity of concrete in cum executed under the sub-soil water. The depth of centre of gravity shall be reconed correct to 0.10 m 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored.
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.31:Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.23:Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
13.23.1:Extra for plastering on circular work not exceeding 6 m in radius.In one coat
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
OD255408/2023-2024:Supplying and fitting 600 mm X 600 mm C I manhole cover fitting during casting of floor slab
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
OD273439/2023-2024:Charges for preparation of Good For Construction (GFC) drawings (both structural & architectural) through an accredited Structural Engineer/Govt. Accredited Agency after conducting Soil Investigation at 12m dia well cum pump house and connected works,Construction of Foot Bridge . The charges include the vetting charges for M/s WASCON, submission of 3 set of minimum A3 size Drawings for vetting by WASCON, soft copy of drawing in AUTOCAD and including any other design consultation charges complete as per direction of Departmental Engineer - In - Charge of the work.
Appendix-B(1)- Construction of Foot Bridge for 12m diameter Intake Well
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
OD256651/2023-2024:Bailing out from trenches by engaging man mazdoor using buckets including hire charges
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.52.2:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Appendix-B (2)-Construction of Raw Water pump House
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
OD256485/2023-2024:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.<br>With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre
13.52.2:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.63.1:Painting with aluminium paint of approved brand and manufacture to give an even shade.Two or more coats on new work
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.71:Lettering with black Japan pint of approved brand and manufacture
OD256486/2023-2024:Fire extinguisher system
OD256487/2023-2024:Providing in Pump house LED Tube
OD256488/2023-2024:Providing LED Bulb holder
OD256489/2023-2024:Providing in pump hose, Normal plug point
OD256490/2023-2024:Providing in pump house heavy duty plug point
OD256491/2023-2024:Providing wall fan Pump house inside
OD256492/2023-2024:pressed steel door double door with bottom
OD256493/2023-2024:ventilator 600*450
OD256494/2023-2024:Pressed steel window (1500*1350)
Appendix-B(3)-Construction of 12m diameter intake well -Electrification
OD256717/2023-2024:Providing Panel board,ELCB,MCCB,Earthing,Lights,Fans,Spot Lights etc
Appendix-B(4)-Construction of 1000KVA transformer room
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
OD256443/2023-2024:Bailing out from trenches by engaging man mazdoor using buckets including hire charges
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
10.25.1:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
OD256446/2023-2024:Providing and fixing precoated Plastic Roofing sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge). <br>These sheets are the least preferred option for roofing applications in most places in the country. As they are less durable than other types of roofing sheets, they are mainly used as covering temporary structures. The better the quality of the plastic, the higher will be the price of the roofing sheet. This elevates the overall cost of installation of plastic sheets.
App:B(5)-Construction of inspection chamber(Gallery)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
100.3.9.2:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.00m including neat banking.
100.3.9.3:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.50m including neat banking.
100.3.9.4:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 4.50m to 6.0m including neat banking.
100.6.1:Providing steel sheet shoring to the sides of the trenches to depths of above 4.00 m but not exceeding 6.00m using 6 mm M.S. sheet 0.50 M wide stiffen on edges with 50 mm x 50mm x 6 mm M.S. angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.5 M above ground level suitably braced by horizontal walling pieces at 75 x 150 mm x 8 mm angles on either side at intervals not exceeding 1.50M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed, dismantling, cleaning and restacking for reuse including all labour, hire charges and conveyance for equipments, tools and plants and sundries etc. complete.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.15:Extra for laying concrete in or under water and or liquid mud including cost of pumping or bailing out water and removing slush etc. complete. Note for item No. 4.15 : - The quantity will be calculated by multiplying the depth measured from the sub-soil water level upto centre of gravity of concrete under sub-soil water level with quantity of concrete in cum executed under the sub-soil water. The depth of centre of gravity shall be reconed correct to 0.10 m 0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored.
OD257185/2023-2024:Dry rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) including cost of through stone and bond stone.
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.31:Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.16.2:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsAbove 20 cm wide
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
OD257184/2023-2024:Supplying and fitting 600 mm X 600 mm C I manhole cover fitting during casting of floor slab
Appendix-B(6)-Intake arrangements
20.2.2:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).400 mm dia piles
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.31:Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
100.98.129:Supply of DI K9 Pipe Conforming to IS 8329/2000, 1000mm Dia.
100.14.15:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 1000mm diameter Ductile Iron Class K-9 Pipes.
OD257203/2023-2024:Supplying ,conveying and fixing 1000mm CI, D/F Sluice valve with cap and nominal pressure designated with high tensile brass stem conforming to IS:14846/2000 in intake pipes.
OD257204/2023-2024:Providing stainless steel screens on ends of both intake pipes with stainless steel chanel and stainless steel 12mm dia bars both ways welded 10 cm c/c as per the direction of Engineer in charge.
20.6.3.2:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Group of two or more piles upto 50 tonne capacityRoutine test
Appendix-B(7)-Construction of Retaining and Compound Wall Intake Well Site. and Construction of Toilet at Intake well site
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.37.1:White washing with lime to give an even shade:New work (three or more coats)
13.39.1:Colour washing such as green, blue or buff to give an even shade:New work ( two or more coats) with a base coat of white washing with lime
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
9.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
OD256891/2023-2024:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.<br>With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre
13.63.1:Painting with aluminium paint of approved brand and manufacture to give an even shade.Two or more coats on new work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
4.6.1:Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)
OD256969/2023-2024:Providing and fixing 63 mm dia PVC pipes for weep holes
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD270057/2023-2024:Design charges for Structural and Architectural (CD with Color Print 5 Copy)
Appendix-B(8)-Providing lightening protection system to Intake well
OD257002/2023-2024:Providing lightening protection system to Intake well structure as per ISI standards.
App:C - Laying 800mm DIK9 Raw Water Pumping main from Intake well to WTP
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.59:Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge.
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.2:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.1.6:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Ordinary Rock.
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.2.8:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
100.1.14:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
100.14.13:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 800mm diameter Ductile Iron Class K-9 Pipes.
18.70.13:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:800 mm dia pipes
100.32.7:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 200mm Double Acting Air Valve.
100.31.2.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class II.
100.22.3:Labour for cutting C.I. pipe with steel saw: 800mm diameter C.I. pipe.
100.35.13:Testing 800mm DI/CI pipeline with potable water to the required test pressure. 800 mm dia Observed Data derived from item no.1032 of PHED DATA
100.37.24.1:In situ fabrication of M.S. pipes of size 800mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
OD256256/2023-2024:Laying 800mm MS pipe and specials after conveying stacked pipe from nearby site, alignment clearing ready for jointing in the open/trenches as per direction
100.37.24.2:Fabricating M.S. flanges of diameter 800mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.37.24.3:Cutting 800mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.37.24.4:Welding 800mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.37.24.5:Grinding cut and weld edges of 800mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.19.3:Providing flanged joints to double flanged CI/DI pipes and specials, including testing of joints: 800mm Diameter Pipe.
100.31.2.15:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 800mm diameter, Class II.
100.31.2.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class II.
18.68.2:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Above 600 mm dia
18.69.2:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Above 600 mm dia
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
OD256264/2023-2024:Clearing site after completion of work for removing excess earth for trenches with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m away from work site on contractors on risk.
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
100.59.2:Refilling the trenches with a wet mix of close graded granular materials (Stone aggregate - 25mm nominal size - 17.5%, Stone aggregate - 10mm nominal size - 17.5%, Crushed Stone - 2.36mm to 12.5mm - 25%, Stone chippings / screenings - 4.75mm nominal size - 20%, Stone chippings / screenings - 150 micron nominal size - 20%), mixing properly after adding sufficient quantity of water, refilling in layers not exceeding 150mm, compacting properly at Optimum Moisture Content with Surface Plate Vibrator and disposing the excavated material etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites.
OD302516/2023-2024:GIS mapping, Drawings soft copy and hard copy submitted on each bill, and finally submitted the full data.GIS mapping coordinates of regular intervals regarding sizes and locations of pipes, valves, and other all attributes in order to proper asset management and future servicing of the system and in order to upload in Google map.Drawings soft copy and hard copy(4Nos) with final bill .As per the Circular issued by the CE)SR) The GIS map soft copy and hard copy to be submitted to Jalabhavan (GIS wing) through the concerned EE in order to upload to the web site
App:C(1) - Cost Of Materials for RWPM 800mm DIK9
100.98.127:Supply of DI K9 Pipe Conforming to IS 8329/2000, 800mm Dia.
100.98.453:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 200mm.
100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.
100.98.467:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 500mm.
App :C(2) - LSGD Road Restoration .
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.2a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.11.1.A.2a:Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 By Manual Means :- Type A (II) Bitumen (S-65)
App:C(3) - Road Restoration for LSGD roads-Reconcrete
16.78.3:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
App:C(4)- Construction of Valve Chamber
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.
App:D - Common CWPMs from WTP to Various tanks
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.59:Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
100.4.1:Excavating in hard rock for trenches by blasting for laying pipes and stacking useful materials for measurements and disposing unserviceable materials within the initial lead of 50m and lift up to 1.50m (depth from 0.0m to 1.50m) and providing protection by earth filled cement bags during blasting to avoid damages to nearby structures (200 Nos. of earth filled cement bags for 10m3 of blasting)
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
100.14.6:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 350mm diameter Ductile Iron Class K-9 Pipes.
18.70.6:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:350 mm dia pipes
100.35.6:Testing 350mm DI/CI pipeline with potable water to the required test pressure. 350 mm dia Observed Data derived from item no.1024 of PHED DATA
100.37.10.1:In situ fabrication of M.S. pipes of size 350mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.10.2:Fabricating M.S. flanges of diameter 350mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe
100.37.10.3:Cutting 350mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.4:Welding 350mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.5:Grinding cut and weld edges of 350mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.14.5:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 300mm diameter Ductile Iron Class K-9 Pipes.
18.70.5:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:300 mm dia pipe
100.35.5:Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA
100.37.9.1:In situ fabrication of M.S. pipes of size 300mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.9.2:Fabricating M.S. flanges of diameter 300mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.30.7:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe
100.37.9.3:Cutting 300mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.4:Welding 300mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.9.5:Grinding cut and weld edges of 300mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.14.4:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 250mm diameter Ductile Iron Class K-9 Pipes.
18.70.4:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes
100.35.4:Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA
100.37.8.1:In situ fabrication of M.S. pipes of size 250mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.8.2:Fabricating M.S. flanges of diameter 250mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.30.6:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe
100.37.8.3:Cutting 250mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.8.4:Welding 250mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.8.5:Grinding cut and weld edges of 250mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.83.8:Labour for cutting C.I. pipe with steel saw.350 mm diameter C.I pipe
18.83.7:Labour for cutting C.I. pipe with steel saw.300 mm diameter C.I. pipe
18.83.6:Labour for cutting C.I. pipe with steel saw.250 mm diameter C.I. pipe
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
100.31.2.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class II.
100.31.2.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class II.
100.31.2.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class II.
100.31.2.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class II.
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.
100.32.4:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 80mm Double Acting Air Valve.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
OD302514/2023-2024:GIS mapping, Drawings soft copy and hard copy submitted on each bill, and finally submitted the full data.GIS mapping coordinates of regular intervals regarding sizes and locations of pipes, valves, and other all attributes in order to proper asset management and future servicing of the system and in order to upload in Google map.Drawings soft copy and hard copy(4Nos) with final bill .As per the Circular issued by the CE)SR) The GIS map soft copy and hard copy to be submitted to Jalabhavan (GIS wing) through the concerned EE in order to upload to the web site
App:D (1) - Cost of Materials
100.98.120:Supply of DI K9 Pipe Conforming to IS 8329/2000, 350mm Dia.
100.98.119:Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia.
100.98.118:Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia.
100.98.450:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm.
100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
100.98.462:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm.
100.98.463:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.
100.98.433:Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 250mm.
100.98.434:Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 300mm.
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
App:D (2) - Road Restoration-Chipping Carpet- Panchayath
4.1.A.2:Granular Sub-base with Well Graded Material (Table 400.1)(A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.1a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.11.1.A.5:Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 By Manual Means Type A (V) Natural Rubber Modified Bitumen
5.12.A.2.5:Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means Case - II : Type B (V) Natural Rubber Modified Bitumen
APPENDIX- D(3)- Valve Chamber
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
OD257357/2023-2024:Conveying and fixing 560mm CI MH cover (ISI) heavy duty with frame in position as per the direction of departmental officers.
Appendix-E-Supply, erection and commissioning of 1000 KVA, 11KV/3.3KV (1no) Indoor type Transformer and Connected works for Intake Well site & WTP site
OD256447/2023-2024::11KV Equipments<br>Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms,2sets of 400A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards
10.25.1:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
OD256448/2023-2024:11KV Metering Unit<br>Supply,erection, testing and commissioning of out door type metering <br>unit consisting of the following accessories:<br>Current Transformer<br>CT Ratio 50/5A-3Nos.<br>Burden 15VA<br>Accuracy Class 0.2S<br>Potential Transformer<br>PT ratio 11KV/110V-1No.<br>Burden - 100VA.<br>Accuracy Class 0.2<br>The rate shall include the cost of testing the equipment at KSEB and<br>all other incidental expences. The CT ratio should be fixed only after<br>obtaining the power allocation from KSEB.
OD256449/2023-2024:TOD Meter<br>Supply,erection, testing and commissioning of TOD meter with <br>maximum demand in KVA suitable for the above out door metering set <br>housed in a weather proof out door Kiosk.The rate shall include the <br>cost of testing the equipment at KSEB and all other incidental <br>expences.
OD256450/2023-2024:11KV VCB Panel(Indoor)<br>Supply, erection, testing and commissioning of 11KV, 630A, 350MVA,<br>totally enclosed, single bus bar, floor mounting in metal clad, indoor<br>extensible type flush mounted horizontal isolation and drawout type vacuum<br>circuit breaker four panel system (1 no. VCB as incomer and 2 nos.VCBs<br>& 1 no SFU as outgoings) suitable for installation in 3 phase , 3wire, 50Hz.<br>AC,11kv, effectively earthed supply system,comprising of motorised and<br>spring assisted, independent, trip free closing mechanism and all metering<br>equipments, protective relays etc. complete as approved by Kerala Electrical <br>Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm<br>copper control cables shall be used for all external & internal<br>interconnections. The cost of control cables both internal and external shall<br>be included in the cost of HT panel.
OD256451/2023-2024:3.3KV VCB Panel(Indoor).<br>Supply, erection, testing and commissioning of 3.3KV, 400A, 75MVA,<br>totally enclosed, single bus bar, floor mounting in metal clad, indoor<br>extensible type flush mounted horizontal isolation and drawout type 9<br>panel system comprising of 2nos Vacuum Circuit breakers as incomer,1<br>no as bus coupler and 3 nos. for motors , 2Nos. Vacuum Circuit Breakers<br>( for APFC panel) as outgoings and 1 no as spare. The incomer<br>switchgears, & outgoing switchgears should be of drawout type trip<br>free VCBs suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv,<br>effectively earthed supply system,comprising of motorised and spring<br>assisted, independent, trip free closing mechanisum and all metering<br>equipments, protective relays, etc. complete as approved by Kerala<br>Electrical Inspectorate and relevant standards. Armoured multi core<br>2.5 Sqmm copper control cables shall be used for all external & internal<br>interconnections. The cost of control cables both internal and external<br>shall be included in the cost of 3.3KV panel.
OD256452/2023-2024::3.3KV Off Load Isolators for VT Pumps.<br>Supply, erection, testing and commissioning of 3.3KV, 400A, 75MVA, <br>totally enclosed, single bus bar, floor mounting in metal clad, indoor <br>extensible type flush mounted Off Load Isolator panel suitable for <br>installation in 3 phase , 3wire, 50Hz. AC,3.3kv, effectively earthed <br>supply system,comprising of spring assisted, independent, trip <br>freeclosing mechanism etc. complete as approved by Kerala Electrical <br>Inspectorate and relevant standards. Armoured 2.5 Sqmm copper <br>control cable shall be used for all interconnections. The cost of control <br>cables both internal and external shall be included in the cost of HT <br>panel.<br>
OD256453/2023-2024:11KV/3.3KV, 1000 KVA Transformer<br>Supply,erection, testing and commissioning of 1000 KVA , 11KV/3.3KV.<br>3phase, 50Hz. ONAN cooled , indoor type copper wound distribution<br>transformers, with HV and LV side cable end box arrangements, on load<br>tap changer with 17 tap positions having +5% to -15% variations in1.25%<br>steps with RTCC panel including first filling of oil etc. complete with all<br>fittings as per IS 2026 and Kerala Electrical Inspectorate standards.<br>Armoured multi core 2.5 Sqmm copper control cables shall be used for all<br>external & internal interconnections . The cost of control cables both<br>internal and external shall be included in the cost of Transformer. (Supply for INTRANS)
OD256454/2023-2024:APFC Panel<br>Supply, Installation, Testing and commissioning of 3.3KV, 150 KVAr <br>automatic/manual Power Factor Correction Panel shall be fabricated out <br>of 2mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor <br>Mounting, Front hinged doors for indoor use, removable bottom/top <br>gland plates for incoming cables, dust and vrmin proof (IP: 42 &protection) with TP Aluminium Busbars, complete with busbar <br>connection, internal wiring, name plates, painting etc. as per KEI & standards
OD256455/2023-2024:Neutral Grounding Resistor.<br>Design,engineering, supply erection,testing and commissioning of indoor<br>type 3.3KV stainless steel make neutral grounding resistor in sheet steel<br>enclosure with IP 23 degree protection with siutable neutral CT for REF<br>protection. The cubicle shall be fabricated out of 3mm sheet steel and<br>painted with anti –rust primer coating followed by two coats of paint of<br>approved shade, as per standards. The resistance shall be of Kerala&Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm<br>copper control cable shall be used for all external interconnections. The cost<br>of control cables both internal and external shall be included in the cost of<br>NGR.
OD256457/2023-2024:Power Distribution board (PDB)<br>Supply,erection, testing and commissioning of 8 way MCB distribution <br>board comprising to the following. <br>63A 4 pole MCB 1 No. as incomer with 63A 100mA ELCB and <br>20A TP MCB-2Nos. & 20A SP MCB- 6 Nos each. as outgoings, <br>With tinned copper busbars/cables, interconnection, housed in a suitable <br>metal enclosure as per KEI standards fixed in open system. (Harvels)
OD256458/2023-2024:Lighting Distribution board (LDB)<br>Supply,erection, testing and commissioning of MCB distribution board <br>comprising to the following. <br>40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 <br>AMPS SP MCB as outgoings, <br>With tinned copper busbars/cables, interconnection, housed in a suitable <br>metal enclosure as per KEI standards fixed in open system.
OD256459/2023-2024:Cabling<br>Supply, laying, testing and commissioning of the following size PVC/XLPE <br>insulated, sheathed armoured Aluminium conductor cable (1100 <br>volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips <br>partly laid in cable tray/partly laid in trench
OD256460/2023-2024:Supply of all materials and providing end termination of the following size <br>PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( <br>1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, <br>Transformers, Panel boards etc. complete as per standards.
OD256461/2023-2024:Earthing& lt;br> Plate earthing by using GI/CI plate of 1200*1200*12 mm size as per IE Standards
OD256462/2023-2024:Supply, laying and termination of the following sizes of copper<br>strip/wires for earthing of substation, transformers, HTpanel boards,LT<br>panel boards, equipments and interconnection of earth pits etc
OD256463/2023-2024::MS Items.<br>Supply and fixing of 6mm thick chequered plate with required M.S. <br>angle/plate supports over the masonry cable trench at substation and <br>electrical control room. Angle and plate should be painted one coat of <br>primer and two coats of enamel paint as required
OD256464/2023-2024:Supply and fixing of M.S. angle cable tray for clamping the various sizes<br>of cables in trenches, through walls, & trusses etc. as per KEI & IT standards.
OD256465/2023-2024:Battery& Battery Charger<br>Supplying, fixing, testing and commissioning of Lead acid cell battery 24V, <br>200AH capacity at 10hrs rate of discharge assembled with plante positive <br>and pasted negative plates with inter cell, inter raw, interior connectiors etc. <br>stand and cell insulators, sealed floats, nuts, bolt, washersetc with <br>electrolyte of specific gravity 1.190 and accessories such as voltmeter, <br>Thermometer, Hydrometer, spaners etc with teak wood stand with 3 coats <br>of antiacid paint to accomodate battery.
OD256466/2023-2024:Supplying, fixing, testing and commissioning of automatic twin battery<br>charger with distribution board with all instruments and protective<br>devices etc. complete as per standards
OD256468/2023-2024:Safety Items<br>Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards
OD256469/2023-2024:Amount for preparation of drawing and fees towards Electrical Inspectorate, obtaining necessary approval from Electrical Inspectorate<br>etc and for misc items
Koya and Company Construction Limited
Eco Protection Engineers Private Limited
Bidder Name
Koya and Company Construction Limited
Eco Protection Engineers Private Limited
Everest Infra Ventures India Pvt Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid