Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | ₹8.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.9 L+₹1.0 L (11.8%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹9.9 L+₹1.0 L (11.8%) | L2 | Rejected-Finance L2 |
| 3 | L3₹10.3 L+₹1.5 L (16.9%)Rejected-Finance | ₹10.3 L+₹1.5 L (16.9%) | L3 | Rejected-Finance L3 |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
9 Apr 2024, 6:00 pmClosed
AGE I AF Kumbhirgram
AGE I AF Kumbhirgram Military Engineer Services PO Kumbhirgram Assam Pin 788109 Tele 03841282376
REPAIR/ MAINT OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FAN/ STAND FAN INCLUDING POINT WIRING AND ALLIED WORKS AT AFS KUMBHIRGRAM
2024_MES_647302_1
8570/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION KUMBHIRGRAM
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE I AF Kumbhirgram
₹19,600
Yes
8 Jun 2024
20 Mar 2024
11 Apr 2024
20 Mar 2024
9 Apr 2024
27 Mar 2024
Amount
Taking down carefully copper/aluminium point wiring including sunken MS boxes (light, fans, socket or power) complete, (fittings such as switches, ceiling roses,call bell, pendants, regulators, socket etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc complete all as specified & directed .
Material and labour for point wiring for one light / Fan / Ex Fan point controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in an MS rectangular Box with bakelite sheet cover / PVC rectangular switch board of suitable size for mounting switches, sockets, fan regulators etc or MS modular boxes / PVC modular box suitable for mounting modular switches, sockets etc including testing on completion complete all as specified and directed.
All as per Item No 2 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed.
Material and labour Sub main wiring using two runs of FRLS grade PVC insulated, unsheathed ,stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.
Supply and fix Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as directed by Engineer-in-Charge.
Fixing in repair Switch piano, flush type single pole, one way, 5 Amps (Serviceable switch obtained from item No-1 shall be reused).
Supply and fix modular switch 1 way 6 Amps 1 Module complete all as specified and directed
Supply and fix in repair LED tube light fittings 1 x 09/10 Watt two feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed
Supply and fix in repair LED tube light fittings 1 x 18/20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed
Supply and fix of decorative light stand with 9 watt led bulb complete all as specified and as directed
Supply and fix Ceiling rose 2 or 3 terminal PVC / poly carbonate isolated body complete all as specified and as directed
Fixing only serviceable Ceiling rose 2 or 3 terminal PVC / poly carbonate isolated body complete all as specified and as directed
Supply and fixing in repair switch socket combination 5 Pin 6 Amp with PVC Box complete all as specified and directed.
Supply and fixing of Step type electronic Fan regulator socket type on the existing phonolic laminated sheet etc as required as existing type and size
Supply and fixing of Modular Fan regulator,120 watts complete all as specified and directed.
Supply and fixing white modular cover plate with frame 8 Module complete all as specified and directed.
Supply & fix modular socket 2 in 1,5 pin 6 Amps, 2 modules complete all as specified and directed
Supply and fix in repair PVC casing and caping of size 32 x12 mm complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V, fixed on walls including blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed
Supply and fix sheet metal enclosure MCB DB 8 way SPN double door suitable for 240 V, fixed on walls including blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed
Supply and fix miniature circuit breaker (MCBs) SPN , 240 Volt, 32-40 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed
Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB SPN obtained from unserviceable DBs shall be reused) complete all as specified and directed
Supply and fix MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed
Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB SP obtained from unserviceable DBs shall be reused) complete all as specified and directed
Disconnecting electrical wire of ceiling fan / wall mounted fan of any type/size and make, taking down from its position, opening, cleaning and greasing after removing the blade to make noise free smooth operation including replacement of wornout capacitor, capacitor holder wire connector with pvc twin twisted wire assembling and placing its position using new clamp set (clamp, rubber bush and nut and bolt make sre for firm grip) including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, clamp set, PVC twin twisted wire to be replaced shall be measured and paid separately as supply only item. 2. if fan need repair then submit to defective fan to MES store and take a repaird fan and placed the fan on same position.
Disconnecting electrical connection of wall mounted fan of any type/size and make, taking down from its position, for oilling and greasing the fan motor, oscillation motor, shaft and bush for speed and oscillation control after removing the blade grill ring, blade front and rear grill, blade, check nut to make noise free smooth operation including replacement of wornout capacitor, wire connector, capacitor holder with pvc two core wire, plug top assembling and placing at its own position (make sure for farm grip) including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, clamp set, PVC two wire, plug top to be replaced shall be measured and paid separately as supply only item. 2. if fan need repair then submit the defective fan to MES store and take a repaird fan and placed the fan on same position.
Disconnecting electrical connection of padestal fan or stand fan of any type/size and make, opening it for oilling and greasing the fan motor, oscillation motor, shaft and bush for speed and oscillation control after removing the blade grill ring, blade front and rear grill, blade, check nut to make noise free smooth operation including replacement of wornout capacitor, capacitor holder wire connector with pvc two core wire, plug top etc assembling including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, clamp set, PVC two wire, plug top to be replaced shall be measured and paid separately as supply only item. 2. if fan need repair then submit the defective fan to MES store and take a repaird fan and placed the fan on same position.
Disconnecting electrical connection of Exhaust fan of any type/size and make, taking down from its position, for oiling and greasing the exhaust fan motor,shaft and bush after removing the blade to make noise free smooth operation including replacement of wornout capacitor, capacitor holder wire connector with pvc twin wire assembling and placing at its own position (make sure for farm grip) including testing complete all as directed by Engineer-in-Charge. (NOTE : 1. Spare parts like capacitor, PVC two wire, to be replaced shall be measured and paid separately as supply only item. 2. if fan need repair then submit the defective fan to MES store and take a repaird fan and placed the fan on same position
Material and labour for rewinding of ceiling fan of any sweep after dismenting complete motor assembly, bearings, bushings, shaft, roter, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire to ceiling rose shall be measured and paid separately as supply only.
Material and labour for rewinding of wall mounted fan / Stand fan of any sweep after dismenting complete motor assembly, bearings, bushings, roter shaft, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire, plug top shall be measured and paid separately as supply only.
Material and labour for rewinding of Exhaust Fan of 250 mm to 380 mm sweep after dismenting complete motor assembly, bearings, bushings, roter shaft, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire to ceiling rose shall be measured and paid separately as supply only.
Material and labour for rewinding of Exhaust Fan of 450 mm sweep after dismenting complete motor assembly, bearings, bushings, roter shaft, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size / turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings, bushings, shafts, roter assemble with capacitor, connecting wire, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, shafts, roter capacitor, connecting wire to ceiling rose shall be measured and paid separately as supply only.
Supply only ball bearing for ceiling fan
Supply only roter for ceiling fan as per existing pattern
Supply only Bush and shaft as per existing pattern
Supply only Bush ,Shaft and roter for wall fan, stand fan, Exhaust fan as per existing pattern
Supply only wall mountes fan pvc blade as per existing pattern
Supply only capacitor AC for 230 volts 50 Hz of capacity 1.7 / 2.5 Mfd
Supply only of PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm all as specified and directed.
Supply and fix of 2 core copper conductor of sizes 1.5 sq.mm with taking down of old unserviceable incoming cables of Wall fan and stand fan.
Supply and Fix plug top 3 pin for wall fan and stand fan complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 4 mm dia galvanised iron as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply and fix in repair Switch piano flush button single pole, one way 5 Amp,complete all as specified and directed
Supply and fix in repair Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps (ISI Marked) complete all as specified and directed
Supply and fixing in repair of Modular Fan regulator,120 watts 2 modules complete all as specified and directed
Supply and fix in repair louvers and shutter in circular shape for Exhaust fan of any sweep size and taking down unserviceable complete all as specified and directed
Ms N D Enterpise
M/s Rawat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .