Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.2 L+₹1.1 L (17.7%)Rejected-AOC A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.9 L+₹1.7 L (28.0%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
2 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 871 EWS
GE 871 EWS C/o 56 APO
COMPREHENSIVE MAINTENANCE OF MISC EM SERVICES TO ELECTRIC NETWORK SYSTEM AT HARSIL SUKHI AND TEKLA UNDER GE 871 EWS AT JOSHIMATH
2022_MES_561254_1
8705/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Harsil Sukhi Tekla
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹14,000
Yes
6 Feb 2023
4 Nov 2022
9 Dec 2022
4 Nov 2022
2 Dec 2022
18 Nov 2022
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exc 1.5m but not exceeding 3.0 mtr in depth for foundation. (Laying of under ground cables) in hard/dense soil and getting out all as directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Disconnecting and taking out old existing unserviceable LT under ground cable of any description and in any position from trenches/ under floor,roads,paths or from walls / from poles/ from ducts etc.complete all as specified and directed of 10 sqmm 2 core to 35 sqmm 3.5 core cross sectional area.
Supply, laying, jointing & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 50 sqmm 3.5 core all as per IS , specified & directed. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule).
All as per Item No 8 here-in-before but of size 95 Sqmm 3.5 core.
All as per Item No 8 here-in-before but of size 16 Sqmm 4 core.
All as per Item No 8 here-in-before but of size 16 Sqmm 2 core.
All as per Item No 8 here-in-before but of size 10 Sqmm 2 core.
Supply and fix in replacement of light grade Galvanised mild steel pipe 40 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection . (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ).
Supply and fix in replacement of 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 10 sqmm 2 core flat stranded conductor including taking down old unserviceable cable all as specified and directed.
All as per Item No 14 here-in-before but of size 16 sqmm 2 core.
Dismantling and taking down old unserviceable Steel tubular poles of any type/size complete all as specified and directed.
Supply, erecting and fixing of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type/size complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M & L Foundation for steel tubular poles of concrete 15 cm Depth in bottom of Pit for bed concrete (1:4:8) Type D-2 using 40 mm graded stone aggregate for foundation of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
M & L Foundation for steel tubular poles of PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
Coping for, steel tubular poles (1:2:4) Type B-1 using 20 mm graded stone aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
Dismantling of SVL / MVL/ MH fittings 70 /150 /250 /400 watts from existing poles / buildings of any height/type complete all as specified and directed.
Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and impact resistance of IK07 with 10KV built-in surge protection device including:- Note :-Rates quoted by contractor are deemed to be inclusive of PVC heavy duty conduit mounted with clamp with pole along with 3 core 1.5 sqmm PVC insulated PVC sheathed copper multistranded conductor ISI marked from MCB box to street light complete all as specified.
Supply and fix LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and impact resistance of IK07 with 10KV built-in surge protection device including:- Note :-Rates quoted by contractor are deemed to be inclusive of pvc heavy duty conduit mounted with clamp with pole along with 3 core 1.5 sqmm PVC insulated PVC sheathed copper multistranded conductor ISI marked from MCB box to street light complete all as specified.
Dismantling of insulator any type /size/ grade from over head electric line and setting aside removing from site complete all as specified and as directed by the Engineer in Charge.
Supply and fix Pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt grade.
Supply and fix Insulator shackle type porcelain vitreous, white brown or green 100mm height and 65mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 1100 volt grade complete.
M&L in replacement for earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg)duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion.. (Note : 1. In case the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to Govt.)
M & L in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth wire and protection pipe beyond 7.5 mtr shall be measured and paid separately. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.)
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed. Note :- (a). The trees branches etc shall be left as it is and shall not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they shall be responsible to lift the wood. (b). Prooning of all tree branches up to 6 inches girth in one tree shall be measured as one Job. (c). Contractor shall employ sufficient labour to complete the job with in time as directed. (d). Contractor shall be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor shall take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance shall be provided by MES staff. (f). The contractor shall provide proper tools and safety devices to his staff for prooning of trees.
M & L for Re-stretching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. ( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) . Note:- Five lines together shall be measured as one span from pole to pole.
M & L for Painting to poles (9/11 mtr long) including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
Supply and fixing in replacement MCCBs in existing LT panel box / feeder pillar boxes (KIOSK) of capacity 400 Amps 4 pole breaking capacity 36 KA with thermal as well as magnetic balance adjustable type complete all as specified and directed.
All as per Item No 32 but of capacity 250 Amps and braking capacity 36 KA.
All as per Item No 32 but of capacity 200 Amps and braking capacity 36 KA.
All as per Item No 32 but of capacity 160 Amps and braking capacity 36 KA.
Repairing of existing unserviceable PCC coping of LT/HT pole by dismantling existing coping completely and material and labour for PCC 1:2:4 type B1, 20mm graded stone aggregate of size 600X600X300mm including form work and plastering and two coat of white wash complete all as specified and directed.
Supply and fix in replacement of pole box size 450 x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium bus bar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed.
Supply and fix in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 50 Sqmm including necessary connection complete all as specified and directed.
All as per item No 38 above but aluminium lugs of size 70 to 120 Sq mm.
Supply and fix in replacement of aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply and fix in replacement of wooden block heavy weight of size 30x30x30 cm with hole of 20 cm for fixing of air termination rod of any size incl dismantling and taking down old existing unserviceable wooden block complete all as specified and directed.
Supply and fix in replacement of single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
Supply and fix in replacement of Test point terminal block made of gun metal or phosphorous bronze 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified and directed.
M&L for tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
Supply and fix in replacement cable separator heavy duty made of plastic with PVC clamps heavy duty three phase separator complete all as specified and directed.
(a) Aluminium bus bar capacity 300 Amps for Phase-R-Y-B-3 Nos & 250 Amps for neutral -1 No
(b) MCCB FP 16 KA 100 Amps- 1 Nos(Incoming)
(c) MCCB FP 16 KA 63 Amp - 01 Nos (Outgoing)
(d) MCB DP 10 KA 40 Amps - 02 Nos (outgoing)
(g) complete control panel wiring with stranded copper conductor of suitable size along with one set indicator lamp for R,Y & B for each incoming and outgoing feeder.
Amit Engineering
AKANSHA.ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .