Loading…
Loading…
Tender Value
₹3.7 Cr
EMD Value
₹7.4 L
Closing Date
31 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
15 conditions · 4 needing a document upload
(As per advance correction slip No.1 of GCC April 2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC-April-2022 along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Annexure V :- As per Clause 6.1 Part-1 of GCC- The tenderer shall submit a copy of certificate (Enclosed as Annexure-V) stating that all their statements/documents submitted alongwith bid are true and factual. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid.
The minimum Eligibility Criteria: for costing more than 50 lakhs :- Applicable. 10. Eligibility Criteria: 10.1 Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b (1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution
Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. 10.1Definition of similar works : The criteria for similar nature of work for said tender is given below as CEE/JBP's L. No. WCR/L/10/Similar Nature/3689, dtd. 11.04.2012. similar nature of work criterion for Electrical General Service (GS) for Electrification work in Electrical department of WCR shall include works executed with Central Government, Semi Government/PSUs of Central Government and/or State Governments have been defined as under :- (A)The level of skills required in following work of electrification is almost same. (a) Electrification of service buildings. (b) Electrification of staff quarters, offices. (c) Electrification of offices. (d) Electrification of road & colony lighting. (e) Electrification of circulating area lighting. (f) Erection & commissioning of LT, HT upto 33 kV overhead mains. (g) Sub-station installations & commissioning. (h) Electrification of washing pits, Sheds & Workshops etc. (i) Any above work or combination of (a) to (h) above.
33 conditions · 3 needing a document upload
Labour Cooperative Societies shall submit only 50% of bid security for which the tenderers are required to upload Registration certificate issued by appropriate authority without which their offer will not be considered. Such firms should also declare that -" We are a Labour Cooperative Society and our Registration No. is .................... with .......................and hence required to deposit only 50% of Bid Security
Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security on submission of Registration Certificate issued by appropriate authority. For such firms it is required to upload a copy of Registration Certificate issued by appropriate authority without which their offer will not be considered. Such firms should also declare that - I/We am/are a Startup firm registered by ........................ Department of Industrial Policy and Promotion (DIPP) and my registration number is ................ valid upto ...................... (Copy enclosed) and hence exempted from submission of Bid Security.
THE OFFERS WITHOUT EARNEST MONEY EXCEPT IN CASE OF EXEMPTION CLAIMED AS PER COMMERCIAL COMPLIANCE OF NIT WILL BE SUMMARILY REJECTED.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Performance Guarantee: - Additional 5% PG to besubmitted if tender awarded more than 5% below(Ref : para-4 of Rly. Bd. L.No.2022|CE-UCTIGCC2022[POLICY/Pt.I (E-3320424), Dated13.03.2026.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no.2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017 and amendments/ revisions thereof.
Upgradation and Provision of Power Supply System at Stations, Colonies, Substation and Other Locations in Kota Division.
EL-50-325-2026-27
EL-50-325-2026-27
Open
Works - General
9 Months
Kota, Rajasthan
₹0
₹7.4 L
31 Jul 2026
9 Jul 2026
17 Jul 2026
87 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,71,67,691.88 | ||
| — | 1.00 | — | — | ||
| (A) Supply, installation, testing & commissioning of complete uni pack CSS 1 of with 01 no. 11 KV 500 KVA Dry type Transformer, HT Switchgear with 03 VCB arrangement, GI enclosure and LT distribution board Incoming - ACB 800 Amp. - 02 Nos. and Outgoing - MCCB 400 AMP. 4 Pole - 6 Nos. with tie-feeder as per specification. (B) Supply, installation, testing & commissioning of complete uni pack CSS 2 of with 01 no. 11 KV 500 KVA Dry type Transformer, HT received from CSS- 1, GI enclosure and LT distribution board Incoming - ACB 800 Amp. - 02 Nos. and Outgoing - MCCB 400 AMP. 4 Pole - 6 Nos. with tie-feeder and 150 KVAR APFC Panel as per specification. | — | — | — | 49,42,894.73 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of 75 KvAr Automatic Power Factor Correction Panel (APFC Panel) as per specification attached. | — | — | — | 1,83,688.82 | |
| — | 10.00 | — | — | ||
| Supply and installation of unit maintenance free earth material as per RDSO Specs. No. RDSO/SPN/197/2008 or latest as per technical spec. | — | — | — | 1,40,356.8 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & commissioning of 315 KVA, 11/0.433 KV CRT DRY Type Copper Wound Package Sub Station as per detailed specification. | — | — | — | 31,64,436.8 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of 250 KVA, 11/0.433 KV CRT DRY Type Copper Wound Package Sub Station as per detailed specification. | — | — | — | 62,78,940 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of 200 KVA, 11/0.433 KV CRT DRY Type Copper Wound Package Sub Station as per detailed specification. | — | — | — | 41,62,179 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & commissioning of 100 KVA, 11/0.433 KV CRT DRY Type Copper Wound Package Sub Station as per detailed specification. | — | — | — | 23,86,822 | |
| — | 3.00 | — | — | ||
| Supply, Erection, Wiring, Twsting & Commissioning of HT Vaccum Circuit Breaker 11 kV, 400 to 800 Amps. With standard fitting as per IS 13118/1991 or latest along with power pack as per details. | — | — | — | 16,50,637.74 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of 11 KV Outdoor type extensible 03- way Ring Main Unit (RMU) Floor Mounted, Consisting of 02 no. Incoming 630 Amp. Fixed Manual Load Break Switch and 01 no. Outgoing Fixed Manual Vaccum Circuit Breaker as per attached Detailed Specification Annexure. | — | — | — | 11,19,690 | |
| — | 1.00 | — | — | ||
| Supply, Installation, fabrication, testing & commissioning of LT Distribution panel Enclosure 16 Gauge fabricated with MS angle Size 2175X2700X1000 mm (HXWXD) approx. with door and locking arrangement duly painted red oxide and power coated enamel paint consisting of following items - INCOMING CIRCUIT-02 No. ACB 4 pole 800 Amp. 50 KA Release: Microprocessor based, Type: C-Power S1, with Microswitch for common indication of O/L & S/C (3 each), Ampere meter with selector switches -02 no., voltmeter with selector switch -02 no., indication lamp RYB 06 nos (2 each)., CT 800/5A 15VA- 06 nos., Copper busbar Main 800 Amp. rating- 01 set, Vertical Dropper Busbar - 800 Amp. 01 Set & Earth 250 Amp. - 01 Set, MCB 6A SP C 10KA - 06 nos. OUTGOING CIRCUIT - 08 no. MCCB 4 pole 400 Amp. 50 KA TM Release, 415V 50 HZ. All MCCB in Outgoing circuit will be provided with Extended Rotary Handle and Spreader Terminals - 4 Pole (Set of 8) etc. as per attached detailed specification. | — | — | — | 10,04,292.38 | |
| — | 100.00 | — | — | ||
| Supply of Stranded compacted circular aluminium conductor A2XFY conductor screened with extruded , semi conducting compound XLPE insulated screened with extruded semi conducting compound in combination with copper tape (0.3 kA to 1 sec) core laid up inner sheath (ST-2) PVC galvanized steel strip armoured and overall PVC sheathed black cable HT cable size 3 core x 95 sqmm suitable for 11 kV(E) 6.6 kV (UE) confirming to IS 7098 (Part-II) 1985 /with latest amendments. | — | — | — | 78,942 | |
| — | 500.00 | — | — | ||
| Supply of Stranded compacted circular aluminium conductor A2XFY conductor screened with extruded , semi conducting compound XLPE insulated screened with extruded semi conducting compound in combination with copper tape (0.3 kA to 1 sec) core laid up inner sheath (ST-2) PVC galvanized steel strip armoured and overall PVC sheathed black cable HT cable size 3 core x 70 sqmm suitable for 11 kV(E) 6.6 kV (UE) confirming to IS 7098 (Part-II) 1985 /with latest amendments. | — | — | — | 3,50,000 | |
| — | 600.00 | — | — | ||
| Laying, testing and commissioning of Stranded compacted circular aluminium conductor A2XFY conductor screened with extruded , semi conducting compound XLPE insulated screened with extruded semi conducting compound in combination with copper tape (0.3 kA to 1 sec) core laid up inner sheath (ST-2) PVC galvanized steel strip armoured and overall PVC sheathed black cable HT cable size 3 core sqmm suitable for 11 kV(E) 6.6 kV (UE) confirming to IS 7098(Part-II) 1985 /with latest amendments. | — | — | — | 20,868 | |
| — | 12200.00 | — | — | ||
| Laying of 4 core circular armoured ISI marked XLPE cable size 4 core aluminum conductor 1100 volt with connection etc. Note: Cable will be supplied by Railway. | — | — | — | 3,10,612 | |
| — | 95.00 | — | — | ||
| Supply and fixing of 11 kV cable end box outdoor type heat shrinkable type for 11kV XLPE 3 core 50-95 sq mm size and connection with crimped lugs on cable end box. | — | — | — | 3,51,329.95 | |
| — | 30.00 | — | — | ||
| Supply of material and providing of copper plate Earthing arrangement by digging the Pit. Copper Plate size 600 X 600 X 3 mm as per drg.No.DRM/KOTA/01927/ELR. | — | — | — | 3,26,742.9 | |
| — | 100.00 | — | — | ||
| Supply of material & providing GI. pipe earthing arrangement by digging the pit as per DRM/KTT's Drg. No. 01913EL/R1 or latest complete in all type of soils including rocky area. Earth value will be taken by the contractor in the presence of Railway representative and written on the earth pit by the contractor. | — | — | — | 2,82,666 | |
| — | 10.00 | — | — | ||
| Supply of material & fixing of service pipe 'B' class G.I. 25 mm. dia 3 meters long complete with G.I bend, painted MS clamps of 40x6 mm flat, stay wire, stay insulators and fixing of 2 nos. MS clamp on rigid support or reg bolts, washer & nuts as per Drg. No. Ktt/01624/EL or latest. One no. MS Clamp to be provided for binding of LT armoured cable. | — | — | — | 6,905.6 | |
| — | 900.00 | — | — | ||
| Digging of trench in pucca trench in yard /platform 50cm. deep and 35cm. wide including replaster on surface by cement oncrete after laying of cable. | — | — | — | 2,04,201 | |
| — | 8300.00 | — | — | ||
| Digging of trench in all type of soils/road cutting 100 cm. deep and 50cm. wide including supply and laying of "B" class bricks on both side & top of the cable and refilling the trench after laying of cable. | — | — | — | 11,81,422 | |
| — | 500.00 | — | — | ||
| Drilling of Horizontal bore below track/road by pushing method for laying of HDPE/DWC pipe of various size. | — | — | — | 23,23,455 | |
| — | 540.00 | — | — | ||
| Supply of material, providing, commissioning and laying of DWC/HDPE pipe of 160/138 mm dia cabling under road/track. As per explanatory notes. | — | — | — | 3,48,624 | |
| — | 160.00 | — | — | ||
| Supply, laying, fixing of heavy-duty ISI marked B class GI pipe of 3.65 mm wall thickness & 50 mm diameter to be laid along the wall or floor with proper galvanized clamp through the wall or underneath the floor in cement concrete. | — | — | — | 66,140.8 | |
| — | 30.00 | — | — | ||
| Supply of material, fabrication, fixing, connecting, testing and commissioning of heavy-duty ISI marked B class GI pipe of 80 mm diameter with suitable clamps on rail/pole/joists with nut/bolts and GI socket as per site requirement. | — | — | — | 18,199.5 | |
| — | 110.00 | — | — | ||
| Supply of material, providing and laying of RCC hume pipe 6" dia (150mm) as per IS: 456-1978 or latest in existing trench under Railway track including jointing and all required accessories etc. | — | — | — | 59,492.4 | |
| — | 9.00 | — | — | ||
| Supply, Installation, fabrication, testing & commissioning of LT Distribution panel suitable for outdoor use with canopy and double door type with stand as under, INCOMING CIRCUIT- 01 No. MCCB 4 pole 400 Amp. 50 KA MP based LSIG Adj. O/L Adj. S/C. Ampere meter with selector switch -01 no., voltmeter with selector switch -01 no., indication lamp RYB 03 nos., Change over 01 no., Energy meter - 01 no., CT 400/5- 03 nos., Copper busbar 400 Amp. rating- 01 set, MCB 6A SP C 10KA - 04 nos. OUTPUT CIRCUIT - 04 no. MCCB 3pole 200 Amp. 36 KA TMD, 02 no. MCCB 3pole 100 Amp. 36 KA TMD. All MCCB in incoming and outgoing circuit will be provided with HRC Fuse etc. as per attached detailed specification. | — | — | — | 24,43,493.43 | |
| — | 2.00 | — | — | ||
| Supply of Aluminium Tiltable (Inclined) Tower Ladder with bucket and locking arrangement | — | — | — | 1,70,029.44 | |
| — | 2.00 | — | — | ||
| Supply of Energy efficient 5 star rated submersible pump motor set 150mm dia, Head 214-110 mtr., Motor rating 7.5 H.P., Discharge 50-150LPM ,3 phase 415-volt AC Confirming to IS NO.- 8034/1989 & motor conf. to IS NO.-9283/1995 or latest. | — | — | — | 68,483.4 | |
| — | 2.00 | — | — | ||
| Supply of Energy saver VOS pump motor set Water Lubricated ISI mark 7.5H.P.,2 stage, head-30 mtr., discharge10 LPS delievey size outlet 63 mm confirm to IS no. - 14220 and 1994 or latest. | — | — | — | 1,01,732 | |
| — | 500.00 | — | — | ||
| Supply of PVC insulated flat three core flexible copper industrial cable for submersible pump motor set 1.1 K.V. grade nominal area of conductor 6.0 sqmm as per latest relevant IS: 694 or latest. | — | — | — | 95,990 | |
| — | 40.00 | — | — | ||
| Supply and erection of octagonal galvanized steel pole 5 mtr long with foundation bolts, Double arm type etc. with junction box and cover complete. (a)Pole ID-BOP 5030 (b)Height-5 meter ©Top-70mm (d)Bottom-130mm (e)Thickness-3mm (f)Base plate-200x200x12 mm (g)Foundation bolts-PCD-200 : bolt size 4x16mmx600mm long (IS:1367,Part-III) (h)Double arm brackets (i) Foundation size (WxLxH) 500x500x1000 mm. Note: -1. Octagonal steel poles with foundation bolts should be confirming to std. 35 grade. Base Plate IS 226/IS 2062. Grade of PCC should be M-20 2. All material will be supplied by contractor. | — | — | — | 7,81,876 | |
| — | 100.00 | — | — | ||
| Supply and installation of LED Street light fitting 30 watts suitable for 230 V AC. | — | — | — | 95,331 | |
| — | 10.00 | — | — | ||
| Supply & fixing of 'B' class GI pipe fitting made for 40mm dia for fixing of CFL fittings with all required accessories i.e. MS clamps, nut bolt washers etc. | — | — | — | 5,397.3 | |
| — | 50.00 | — | — | ||
| Supply and erection of concrete for foundation and plinth in other than hard soil & rock as per explanatory notes. | — | — | — | 2,92,227.5 | |
| — | 240.00 | — | — | ||
| Supply and erection of fencing panel & gates at sub-station. | — | — | — | 7,66,598.4 | |
| — | 3.00 | — | — | ||
| Supply and erection of fencing up right. | — | — | — | 2,07,055.41 | |
| — | 50.00 | — | — | ||
| Supply and spreading of gravels/ballast. | — | — | — | 72,799.5 | |
| — | 120.00 | — | — | ||
| Filling with supply of soil to make even surface. | — | — | — | 28,513.2 | |
| — | 1.00 | — | — | ||
| Dismantling, Erection, testing & commissioning (including transportation) of Transformer / LT Panel including civil work complete in all aspect as per attached detailed. All material regarding civil work & other will be provided by contractor. Note: Transformer will be installed on the Structure provided by railway. | — | — | — | 39,804.26 | |
| — | 4.00 | — | — | ||
| Fabrication of suitable size covered shed by supply of material for protection of LT Panel from rain. | — | — | — | 3,64,118.88 | |
| — | 41.00 | — | — | ||
| Supply & fixing of MCB distribution board double door Wall mounted having MCCB 100 Amp TPN on incoming & 12 Nos MCB SP 06-32 Amp braking capacity 10 KA,on outgoing connected through busbar & equally distributed on 3- phase complete with connection. | — | — | — | 3,59,042.74 | |
| — | 5.00 | — | — | ||
| Supply & fixing of 4 poles ON Load Changeover Switch in Steel Sheet Enclosure, Rating-400 Amps., 415V, 50Hz, confirming to IS/IEC 60947-3 Door Interlock and Padlock facility as per detailed specification attached. | — | — | — | 1,42,000 | |
| — | 4.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Online UPS 2 KVA with battery and rack. | — | — | — | 1,69,660 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Clarification for Annexure V
ATTACHMENT
GCC_April-2022_Final.pdf
ATTACHMENT
Annexure of LC
ATTACHMENT
MakeinIndiapolicylatestamendment.pdf Make in India policy latest amendme
ATTACHMENT
Technical Specifications of LED
ATTACHMENT
GCCAdvanceCorrectionSlipNo11.pdf
ATTACHMENT
TenderSch.EL50-3252026-27_1.pdf
ATTACHMENT
Annexure-E.pdf
ATTACHMENT
DempoymentofEngineers.pdf
ATTACHMENT
CorrectionslipofGCC.pdf
ATTACHMENT
500KVACSS12Specifictions.pdf
ATTACHMENT
AnnexureLC-Inclusionofletterofcredit.pdf
ATTACHMENT
Clarification-Annexure-VofGCCwithTenders..pdf
ATTACHMENT
SpecificationofLEDLuminare-2026-1.pdf
ATTACHMENT
MakeinIndiapolicylatestamendment.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .