Municipal Commissioner
Nagar Nigam Dehradun
Tender For 12 mitter and 16 mitter High Mast at Nagar Nigam Dehradun Area
2021_NND_36221_1
195/ST/NNDDUN/2021
Open Tender
Miscellaneous Works
Item Wise
7 days
Nagar Nigam Dehradun
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Senior Finance Officer Nagar Nigam Dehradun
₹80,000
18 Oct 2021
7 Sept 2021
29 Sept 2021
7 Sept 2021
29 Sept 2021
7 Sept 2021
Estimate of 12 Mtr Longh High Mast with 6 Nos 180W LED Flood Light
Supply of Hot dip Galvanized 12.5 mt High mast Shaft in One SECTION SUITABLE FOR 47M/Sec Wind Speed, with raising lowering system comprising, Head frame, luminaries carriage suitable to Install 6 Nos. Luminaries in symmetrical arrangement, double drum winch 5mm diameter SS wire Rope trailing Cable connector, Integral power tool motor, manual handle, Junction Box Lightening Final, Wiring material, Power Cables Between panel and Mast MCB in base compartment are not included.(3 Wire rope system).
Supply of Foundation Bolts manufactured from special steel along with nuts, Washers anchor plate and common template
Supply of Flood Light 180 W, Flood light having PDC Housing 180W+5W, Input Voltage AC 140 to 270 V AC with Auto resetting Safety Cut-off Power Factor>0.95, Driver Efficiency>85% IEC Compliance Confirming to IEC-61347-1 & IEC 61347-2- 13 IEC 61547,610-3-2, Driver should also have 5Kv Inbuilt and 10Kv External Surge Protection, Short/double phase protection, THD(1)< 10% Humidity 10% to 90% RH Working Temp- 10C to+50C, System Lumen 19800 System Efficacy 110Lm/Watt LM79 from NABL lab, LED Make-CREE/NICHIA/OSRAM/LUMILEDS CRS is mandatory Shoul have Vailed ISO.
Supply of Control panel suitable for above mast with timer.
Supply of Twin dome Aviation Obstruction light of Type SLE AL 108 with LED type
Erection Part
Construction of Shallow foundation with M20 grade concrete for the highmast Considering the safe soil bearing Capcity at site as 10 T/Sq Mtr at 2 mt depth with all Materials and labour.
Erection of the high Mast With the help of Suitable tools and plants wiring of luminaires with all wiring material like PVC Insulated PVC sheathed fiexible cable of Suitable copper conductor Cores of 1.5 sq mm Lugs MCB and connection wire approximate 50 mtr, 16 mm 4 core all labor.
Provision of GI Pipe earthing for high mast with 2.5 Sq M long 40mm dia GI pipe Indluding connection of high Mast earth terminal with 25x3 mm GI Flates with all material and labour(2nos per Mast Required)
Installation of the Mast Feeder pillar by grouting the stand in concrete.
Estimate of 16 Mtr Longh High Mast with 8 Nos 250W LED Flood Light.
Supply of Hot dip Galvanized mast of mean height of 16 m suitable for mounting 6 Light fittings symmetrically. Top OAF-150 mm, Bottom OAF-360 mm, Thickness-2/4 mm. Base plate-560x25 mm. Accessories supplied will include heardframe, lantem carriage with 8 Luminaire arms suitable for mounting 8 nos of 250 W LED luminaires symmetrically, SGDD winch with 6 mm wire ropes 2350 BL capacity (3 w rope system), lightning arrestor, Junction box, trailing able 5cx2.5 sq mm cable-1 nos, Carriage supports.
Foundation accessories consisting of 8 no. of M30x850 mm foundation bolts, nits, 1 no anchor plate and 50% template.
Supply of Flood Light having PDC Housing 250W+5W, Input Voltage AC 140 to 270 V AC with Auto resetting Safety Cut-off Power Factor>0.95, Driver Efficiency>85% IEC Compliance Confirming to IEC-61347-1 & IEC 61347-2- 13 IEC 61547,610-3-2, Driver should also have 5Kv Inbuilt and 10Kv External Surge Protection, Short/double phase protection, THD(1)< 10% Humidity 10% to 90% RH Working Temp- 10C to+50C, System Lumen 27500+5%, System Efficacy 110Lm/Watt LM79 from NABL lab, LED Make-CREE/NICHIA/OSRAM/LUMILEDS CRS is mandatory Shoul have Vailed ISO.
Supply of Control panel suitable for above mast with timer.
Supply of Twin dome Aviation Obstruction light of Type SLE AL 108 with LED type
Erection Part
Construction of Shallow foundation with M20 grade concrete for the highmast Considering the safe soil bearing Capcity at site as 10T/Sq Mtr at 2 mt depth with all Materials and labour
Errection of the high Mast With the help of Suitable tools and plants wiring of luminaires with all wiring material like PVC Insulated PVC sheathed fiexible cable of Suitable copper conductor Cores of 1.5 sq mm Lugs MCB and all labour. MCB and connection wire approximate 50 mtr, 16 mm 4 core all labor.
Provision of GI Pipe earthing for high mast with 2.5 Sq m long 40mm dia GI pipe Indluding connection of high Mast earth terminal with 25x3 mm GI Flates with all material and labour(2nos per Mast Required)
Installation of the Mast Feeder pillar by grouting the stand in concrete.
M/s Vijay Electric Works
Shubham Traders
ESSWIN ELECTRO CONTROLS PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .