| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC KUMMAMKULAM HOUSE KADAVANTHRA KOCHI 682 020 | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC ACCEPTED BEING LOWEST TENDERER | |
| 2 | L2₹37.1 L+₹86,203.45 (2.38%)Rejected-Finance 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Rejected being not lowest | |
| 3 | L3₹38.1 L+₹1.9 L (5.15%)Rejected-AOC CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST | |
| 4 | L4₹38.9 L+₹2.6 L (7.23%)Rejected-Finance | L4 | Rejected-Finance Rejected being not lowest | |
| 5 | L5₹38.9 L+₹2.7 L (7.41%)Rejected-Finance KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L5 | Rejected-Finance Rejected being not lowest |
Tender Value
Refer Docs
EMD Value
₹99,240
Closing Date
29 Jun 2021, 6:00 pmClosed
SK Choudhary IDSE EE GE NW Kochi
GE NW Kochi Kataribagh Naval Base Post Pin 682004
PROVISION OF HARDSTANDING AND PATHWAYS IN THE FRONT OF GARDEN OF P 49 BUILDING FOR SETTING UP OF AIRCRAFT STRUCTURAL TRAINING ENVIRONMENT AT NIAT AND CERTAIN SANCTION WORKS OF AGE B R II AT NAVAL BASE KOCHI UNDER GE NW KOCHI
2021_MES_447263_1
8298
Open Tender
Civil Works
Works
180 days
GE NW Kochi Kataribagh Naval Base Post Pin 682004
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW Kochi
₹99,240
Yes
7 Aug 2021
2 Jun 2021
3 Jul 2021
3 Jun 2021
29 Jun 2021
16 Jun 2021
Amount
M&L Surface dressing n exc 15 cm deep for soft /loose soil compleate all as specified and directed by Engr-in-Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface compleate all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:4:8, Type D-2 using 40 mm graded stone aggregate compleate all as specified and directed by Engr-in-Charge.
M&L for Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm under floors or in foundations spreading and levelling in layers n exc. 25cm thick as required compleate all as specified and directed by Engr-in-Charge.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and pigment compleate all as specified and directed by Engr-in-Charge.
M & L for chequered colour cement concrete tiles 20x20cmx 25mm thick set jointed and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 15mm thick in cm 1:4 compleate all as specified and directed by Engr-in-Charge.
M&L for providing cement concrete Type B0, 1:2:4 (using 12.5mm graded aggregate) as in kerb including weathering, slightly rounded or chamfered angles and throating compleate all as specified and directed by Engr-in-Charge.
M&L for excavating in trenches n. exc 1.5m wide and n exc. 1.5m in depth for foundations etc. pier holes n exc 10sqm on plan and n exc. 1.5m in depth in soft /loose soil compleate all as specified and directed by Engr-in-Charge.
Excavation over area not exceeding 1.5m deep and getting out compleate all as specified and directed by Engr-in-Charge.
M&L Cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate in foundations, filling and mass concrete compleate all as specified and directed by Engr-in-Charge.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter compleate all as specified and directed by Engr-in-Charge.
M & L for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete compleate all as specified and directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point compleate all as specified and directed by Engr-in-Charge.
Returning filling in including spreading leveling watering and well ramming in layers not exc 15cm thick compleate all as specified and directed by Engr-in-Charge.
M&L for formwork to sides of pillars posts ,struts, piers, columns etc compleate all as specified and directed by Engr-in-Charge.
M & L for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) in columns, etc compleate all as specified and directed by Engr-in-Charge.
M&L for Pre-cast cement concrete block masonry with solid blocks in PCC 1:3:6, exc. 10 cm in width and setting in mortar in CM 1:6 compleate all as specified and directed by Engr-in-Charge.
M&L for Rendering 15mm thick in CM 1:6 including waterproofing compound,internally on brick or concrete surfaces of wall including finishing even and smooth without using extra cement compleate all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound compleate all as specified and directed by Engr-in-Charge.
M&L for preparation new plastered External surfaces for preparation of surface and applying two coats of weather proof (antifungal, Asian Ultima Protek) paint over a coat of suitable primer over 3mm thick wall care putty of three layer, complete all as specified and as directed by the Engineer-In-Charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
M&L Rolled sections (Tublar sections) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and ; fixed with angle cleats or other connecting plates compleate all as specified and directed by Engr-in-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E 250) Quality A or Fe-290 (Gde E-165) compleate all as specified and directed by Engr-in-Charge.
S&F TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders compleate all as specified and directed by Engr-in-Charge.
M&L for preparation of new Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive Epoxy paint over a coat of Epoxy primer, over a coat of red oxide on steel surfaces compleate all as specified and directed by Engr-in-Charge. (Make-Asian Apcolite or Equal from Berger, Nerolac)
M&L for fixing mini MP tiles in CM 1:4, 15mm thick compleate all as specified and directed by Engr-in-Charge.
M&L for 20mm thick granite (of any type) work with pattern (table rubbed and polished) in steps, jambs, pillars,vertical surfaces window cills, cooking platforms and the like in cement mortar 1:4 , 15mm thick including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compleate all as specified and directed by Engr-in-Charge.
M&L for mangalore pattern roof tiles, interlocking at side joints, laid dry compleate all as specified and directed by Engr-in-Charge.
Demolition of brick work/stone/boulder built in cement mortar including all quions,arches,pillars etc complete all as specified and directed
M&L for Pre-cast cement concrete block masonry type C1 (1:3:6) (using 20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6 compleate all as specified and directed by Engr-in-Charge.
M&L rendering 15mm thick on fair faces of brick/concrete surfaces in cm 1:6 finished even and smooth with out using extra cement compleate all as specified and directed by Engr-in-Charge.
M&L Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters walk ways, railings frame work of water tanks and similar work conforming to Fe-290 Gde E-165 compleate all as specified and directed by Engr-in-Charge.
Preperation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer compleate all as specified and directed by Engr-in-Charge.
M&L 75 mm thick cmeent concrete type D-2 1 :4 : 8 type using 40 mm graded crushed stone aggregate as in sub base of ceequrred tiles compleate all as specified and directed by Engr-in-Charge.
M & L for moorum /red Bajri filling in floors or pavings , laid in layers n exc 15 cm thick spread levelled and rammed including watering compleate all as specified and directed by Engr-in-Charge.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade compleate all as specified and directed by Engr-in-Charge.
M&L for rendering 10 mm thick on brick surfaces in 1:6 cement mortar compleate all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement based paint over a coat of alkali resistant primer compleate all as specified and directed by Engr-in-Charge.
S&F LED Flood light fitting Secures 150 Watt, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light, suitable for highlighting architectural facade and general purpose lighting, heat resistant, toughened glass with frame with IP 66 Protection compleate all as specified and directed by Engr-in-Charge.
S&F surface mounted, powder coated focus light 30 watt with die cast auminium housing and anodized aluminium reflector. Clear difused and fully adjustable with 40 degree beam angle compleate all as specified and directed by Engr-in-Charge.
S& F in replacement PVC insulated copper conductor 3 core 2.5 sqmm cable to be drawn inside the pole compleate all as specified and directed by Engr-in-Charge. ed. Make : Havells/Polycab/
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power UG cable with stranded aluminium conductor 1100 V grade of size 16 sqmm 4 core complete all as specified and directed
Excavation in trenches hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable compleate all as specified and directed by Engr-in-Charge.
Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection compleate all as specified and directed by Engr-in-Charge.
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Supply and lay in trenches/fixed on walls/poles GI tubing medium grade with all fittings of 40 mm bore compleate all as specified and directed by Engr-in-Charge.
Cutting existing road/hardstand of any type by using crow bar chisel etc not exceeding 45 cm wide and not exceeding 1.5 mtr depth for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. (GI pipe will be measured and paid separately)
Anaswara Constructions
ANIE JOHN CONTRACTORS
M.J. Leons and sons
Albert Rebello and Company
THOMSONS CONSTRUCTIONS
SUKU CONSTRUCTIONS
MS BUILDERS
K.V.GEORGE AND COMPANY
M/S Joshy and Sons
SHAIJAL T M
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .