Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 29 NANDANVAN ROAD GARUDEO NAGAR NAGPUR NAGPUR MAHARASHTRA 440009 | 440009 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NO 2 429 VOLTECH ECO TOWER ASIA POWER ELECTRICAL PRIVATE LIMITED MOUNT POONAMALLE ROAD AYYAPPANTHANGAL CHENNAI KANCHIPURAM TAMIL NADU 600056 | THIRUVALLUR | TAMIL NADU | 600056 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
26 Dec 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM P and P
DEPUTY GENERAL MANAGER PROJECTS AND PLANNING PD ADMINISTRATION
Overhauling of Transformers in petrochemical Plants 2024 2025
2024_FACT_837848_1
5062/2024-2025/E30540
Open Tender
Miscellaneous Works
Item Rate
365 days
Udyogamandal
ATTACHED IN TERMS AND CONDITIONS
6 documents required · 6 mandatory
₹0
₹12,000
Yes
27 Dec 2024
4 Dec 2024
27 Dec 2024
4 Dec 2024
26 Dec 2024
4 Dec 2024
Overhauling of Transformers in petrochemical Plants 2024-2025
Overhauling of 11/0.433 KV, 1.6 MVA Power Transformer having oil capacity less than or equal to 2500 litres and complete body painting. Scope of work: A) Preliminary inspection of the Transformer. B) Draining of oil from the Transformer. C) Disconnection and disassembling of bushings, conservator, pipe lines, cooling fins, tap-changer, Inspection windows, Explosion vent unit, main tank lid etc. And reassembling after replacement of all gaskets (Lifting of main tank lid with chain pulley or crane if required) D) Dismantling of conservator tank, Inspection, cleaning, varnishing the interior (if needed) and reassembling after replacement of all gaskets. E) Servicing of MOLG / Level gauge (shall be replaced if found necessary) F) Servicing oil and winding temperature indicator. (shall be replaced if found necessary). G) Replacement of explosion vent diaphragm and wire guard together with gaskets. H) Flushing the interior of the body and windings with new oil to clean inside. I) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows Buchholz relay, breather & pipe lines and main lid. J) Inspection of drain valves, radiator valves, HV, LV & Neutral bushings. (shall be replaced if found necessary) K) Dismantling, testing and servicing of Buchholz relay (shall be replaced if found necessary) L) Inspection and tightening the inner connections. M) Rinsing of radiators with oil and inspection. N) Reassembling of the transformer to its original shape. O) Refilling of transformer old oil with new oil (shall be replaced if found necessary), processing and testing as per cl.5 of special conditions. P) Vacuum oil filling of the transformer. Q) Processing oil to the required level as per cl.5 of special conditions. R) Testing of oil as per cl.5 of special conditions. S) Transformer body cleaning and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint, including supply of all required materials. T) Pre-commissioning checks such as oil leaks, air release, insulation values, ratio and magnetic balance tests, temperature alarm and trip settings required for energisation of transformer and rectification if required. Note: Disconnection and connection of Incoming and outgoing cables as per direction of Engineer in-charge is in scope of vendor.
Overhauling of TELK make 11/3.45 KV, 6.3 MVA Power Transformer of oil capacity-3215 litres and complete body painting. Scope of work: A) Preliminary inspection of the Transformer. B) Draining of oil from the Transformer. C) Disconnection and disassembling of bushings, conservator, pipe lines, cooling fins, tap-changer, Inspection windows, Explosion vent unit, main tank lid etc. And reassembling after replacement of all gaskets (Lifting of main tank lid with chain pulley or crane if required) D) Dismantling of conservator tank, Inspection, cleaning, varnishing the interior (if needed) and reassembling after replacement of all gaskets. E) Servicing of MOLG / Level gauge (shall be replaced if found necessary) F) Servicing oil and winding temperature indicator. (shall be replaced if found necessary). G) Replacement of explosion vent diaphragm and wire guard together with gaskets. H) Flushing the interior of the body and windings with new oil to clean inside. I) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows Buchholz relay, breather & pipe lines and main lid. J) Inspection of drain valves, radiator valves, HV, LV & Neutral bushings. (shall be replaced if found necessary) K) Dismantling, testing and servicing of Buchholz relay (shall be replaced if found necessary) L) Inspection and tightening the inner connections. M) Rinsing of radiators with oil and inspection. N) Reassembling of the transformer to its original shape. O) Refilling of transformer old oil with new oil (shall be replaced if found necessary), processing and testing as per cl.5 of special conditions. P) Vacuum oil filling of the transformer. Q) Processing oil to the required level as per cl.5 of special conditions. R) Testing of oil as per cl.5 of special conditions. S) Transformer body cleaning and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint, including supply of all required materials. T) Pre-commissioning checks such as oil leaks, air release, insulation values, ratio and magnetic balance tests, temperature alarm and trip settings required for energisation of transformer and rectification if required. Note: Disconnection and connection of Incoming and outgoing cables as per direction of Engineer in-charge is in scope of vendor.
Supply of gaskets and oil seals for The power transformer, 11/0.433 KV, 1.6 MVA Transformer, Oil capacity less than or equal to 2500 litres. Specifications of Rubberised Cork Gasket: The supplied gasket shall confirm to IS 4253 Part II : 2018 and following specifications: Type: C- very good oil resistant Grade: R C-70 A Tensile Strength: 1550 KPa (minimum) Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 IRHD Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)
Supply of gaskets and oil seals for the transformer, TELK make 11/3.45 KV, 6.3 MVA Transformer Oil capacity-3215 litres. Specifications of Rubberised Cork Gasket: The supplied gasket shall confirm to IS 4253 Part II : 2018 and following specifications: Type: C- very good oil resistant Grade: R C-70 A Tensile Strength: 1550 KPa (minimum) Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 IRHD Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)
Supply and fixing of new Silica gel air breather assembly with Indicating Type Silica gel and air dash pot for 6300 kVA Transformer, Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on LT side of Transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer, Oil capacity-2280 litres. Rated current 3150A, Rated Voltage - 3.6KV, confirming to IS 3347 & IS 2099 with latest amendments. Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on LT side of Transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer, Oil capacity-1220 litres. Rated current 3150A, Rated Voltage - 3.6KV, confirming to IS 3347 & IS 2099 with latest amendments. Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on LT side of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer, Oil capacity-3215 litres. Rated current 2000A, Rated Voltage - 3.6KV, confirming to IS 3347 & IS 2099 with latest amendments. Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on HT side of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer Oil capacity-3215 litres. Rated current 630A, Rated Voltage - 12/17.5KV, confirming to IS 3347 & IS 2099 with latest amendments. Note: This is an optional item and the supply is insisted only on actual requirement.
Supply of Oil temperature indicator of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer, Oil capacity-3215 litres Note: This is an optional item and the supply is insisted only on actual requirement.
Supply of Winding temperature indicator of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer, Oil capacity-3215 litres Note: This is an optional item and the supply is insisted only on actual requirement.
Supply of Buchholz relay having technical parameters as per IS -3637 having fallowing specifications. Relay Size: 50NB GOR-2. Flange Size: Round flange having diameter 150mm. Flange mounting Details: 4 holes having Diameter 18mm on 115PCD. Flange to flange distance: 215mm. Gas volume for alarm contact 177-225. Suitable for Transformers having rating between 1MVA to 10MVA. Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes of neutral of power Transformer having details as below: 11/0.433 kV, 1.6 MVA Transformer, Oil capacity-less than 1220 litres. Rated current 2000A, Rated Voltage - 3.6KV, confirming to IS 3347 & IS 2099 with latest amendments. Note: This is an optional item and the supply is insisted only on actual requirement.
Supply of magnetic oil level gauge for transformers mentioned in SOW S. No 1 and 2 as per site requirement and direction of engineer in-charge. Note: This is an optional item and the supply is insisted only on actual requirement.
Asia Power Electrical Pvt Ltd (BID ID -3141621)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .