GE(NORTH) AMBALA CANTT
SPECIAL REPAIR TO 06 X OR MD ACCN BLOCK NO P-64/1-6, CONSTRUCTION OF BATHROOM TOILET NEAR BLDG NO HT-09, PROVN OF FALSE CEILING, FLOOR TILING IN BLDG. NO. HT-9 OFFICE COMPLEX AND CERTAIN MINOR WORKS IN THE AOR OF AGE B/R-I
2021_MES_462686_1
GE(N)Amb-42/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE(NORTH) AMBALA CANTT
As Per Tender Document
8 documents required · 8 mandatory
₹500
Yes
GE(NORTH) AMBALA CANTT
₹98,000
Yes
28 Dec 2021
2 Nov 2021
6 Dec 2021
2 Nov 2021
4 Dec 2021
20 Nov 2021
2 Nov 2021 - 20 Nov 2021
Amount
Schedule 'B' Part-I (B/R itmes) M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:4 including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
M&L rough cast plaster 15 mm thick in cement motar 1 :3 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 15 mm thick on the other side of lathing in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of acrylic distemper using painting roller over and including 2 mm thick wall care putty white cement based in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on fair faces of brick work or concrete ceiling or chajjas surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks using old servicable bricks including cleaning of old bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks old size in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks old size in one brick thick honey-comb wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Demolition of concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles premium/1st quality in vertical surfaces/skirtings/dados of size 300x600 x7mm/ 450x 350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L non skid coloured ceramic joint free tiles premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L non skid coloured ceramic joint free tiles premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L non skid coloured ceramic joint free tiles premium/1st quality 7 to 8 mm thick, (Square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 10 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M &L 10mm thick vitrified coloured paver tiles (Endura Tiles) of size 300 x 300mm in floors etc set and jointed in neat cment slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1 :4 ,complete all as specified and as directed by the Engineer-in-Charge.
M & L 16 to 18 mm thick green baroda marble work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in surface channels and drain complete all as specified and as directed by the Engineer-in-Charge.
M & L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, mould, mitred/ stopped end etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 gm per sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150gm per sqm (Az 150) coating as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
M&L rolled mild steel framed work as in chowkhats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-W(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair mild steel, plain, black sheet 1.00 mm thick in hearths, covering to door shutters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels, etc. cut to size holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel frames etc.with plain 40 mm lap joints with welded/riveted seams including bending, turning up, mitred angles, etc. as required complete all as specified and as directed by the Engineer-in-Charge
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing factory made uPVC white colour Sliding window area n.exc 2.00sqm each , three track made of extruded profiles with wall thickness of 2.3mm (+/-0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh Sash (42mm x 57mm), Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2+/ -0.2mm thick galvanized steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. hardware: [Touch Lock of zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.)
S&F as in repair mild steel door shutter two leaves with frame of 20 gauge MS sheet (all around) and leaves of 21 gauge MS Sheet ( all as per Godraj Pettern) with three way locking arrangement with brass lock with CP handle with duplicate key including two coats of spray painting over a coat or red oxide primer complete fixed in existing cupboard with necessary nuts, bolts including embedded in PCC 1:2:4 (area of opening shall be measured) complete all as specified and as directed by the Engineer-in-Charge.
S&F Galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 4.80mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing mild steel butt hinges 100 mm long medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing stainless steel butt hinges 100 mm long medium weight and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply only mild steel butt hinges 50 mm long medium weight cold rolled and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair angular type 15mm bore cast copper alloy chromium plated stop cock, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F angular type 15mm bore cast copper alloy chromium plated stop cock , screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves screwed down, high pressure with crutch or butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves screwed down, high pressure with crutch or butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair 15mm bore cast copper alloy chromium plated stop valves screwed down, high pressure with crutch or butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair 20mm bore cast copper alloy chromium plated stop valves screwed down, high pressure with crutch or butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair 15mm bore cast copper alloy fancy type chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy fancy type chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body screwed down, screwed for iron pipe and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body screwed down, screwed for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125 mm size with or without swivel joint with arm of standard size as per site as in repair complete all as specified and as direced by the Engineer-in-charge.
S&F brass chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
S & F as in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest including PVC 'S' or 'P' trap of pressure rating 6kg per sqm cm complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest including PVC 'S' or 'P' trap of pressure rating 6kg per sqm cm complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair vitreous china wash hand basin white, flat back of size 550mmx400mm with pedestal fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
S & F 500 Litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge. Note:- Tank shall be in white colour.
S & F 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) tripple layer body, 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge. Note : Water storage tank shall be White in colour.
S & F 110 mm bore PVC (SWR) branch piece double (double 'Y') equal or unequal, jointed with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge.
M & L 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 100mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
Taking down eaves gutters, rainwater pipes and sewage/plumbing pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified & directed by the Engr-in-Charge.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in trenches or floors etc as in reapir complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in trenches or floors etc as in reapir complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws as in repair complete all as specified and as directed by the Engineer-in-Charge
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge
S & F as in repair shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and as directed by the Engineer-in-Charge
S & F as in repair brass CP towel ring round between flanges including fixing with brass screws complete fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromiun plated brackets guard and railing 60 cm long as in reapir complete all as specified and as direced by the Engineer-in-charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromiun plated brackets guard and railing 60 cm long complete all as specified and as direced by the Engineer-in-charge.
S & F as in repair stainless steel curtain rod 25mm dia aving wall thickness 1.6mm fixed with and including decorative brackets ,stop roller and glass at the end etc complete all as specified and as directed by the Engineer-in-Charge.
S&F kitchen plate rack of stainless steel sheet 1mm thickness size 900mm x 900mm x250mm and having weight not less than 8.00 Kg each as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair sinks with drainage board made out of stainless steel 1mm thick sheet for kitchen with plugs, waste pipe, brass chromium plated coupling and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge
M&L glazed ceramic white tiles 1st quality of size 150x75x6-7mm thick, set and jointed in neat cement slurry including rendering 10mm thick in cement mortar 1:4 on wall of the buildings as directed by Engineer-in-Charge, writing bldg No./ qtr No.with black marking paint complete all as specified and as directed by the Engineer-in-Charge.
Dismantling Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by the Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the Engineer-in-Charge.
M & L for providing cement concrete 1:2:4 type B1 using 20mm graded aggregate as in roof kerbs or mud stops, padding over roof slab including form work where ever required, rounded or chamfered on edges complete all as specified and as directed by the Engineer-in-Charge.
M & L plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L 40 mm thick brick tiles laid on screed bed and joints grouted flush in CM (1:3) mixed with 5% crude oil by weight of cement including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Description same all as per item No 114 here-in-above but using old servicable brick tiles obtained from item No. 110 here-in -above including cleaning old brick tiles complete all as specified and as directed by the Engineer-in-Charge.
M&L providing water proofing treatment comprising of the following :- (a) Preparing the roof surface with wire brush and cleaning with water and alloy to dry. (b) 20 mm thick cement plaster in cement mortar 1:4 mixed with water proofing compound @ 2% by weight of cement or as per manufacturer instruction ( the corners will be made round in concave shape) and finished even and fair without using extra cement. (c) Applying one coat of bitumen primer conforming to IS-3384-1965 @ 0.5 ltr per sqm on prepared surface. (d) Applying one coat of hot blown bitumen grade 85/25 confirming to IS-702 @1.20kg/sqm (e) Providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt using butane gas torch and ceiling all joints. (f) Applying one coat of hot blown bitumen grade 85/25 confirming to IS-702 @1.20kg/sqm. Note: The membrane shall be extended and inserted into the groove of size 50mm wide and 75mm deep, cut in to the parapet wall sealed with cement plaster (1:3) mixed with WPC @ 2% by weight of cement or as per manufacturer instruction and cost of same is deemed to be included in the quoted rate.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided including cutting of reinforcement complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges, work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in chajjas complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 6 to 8 mm dia cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, spaces, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L providing PCC precast 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, precast cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating etc and setting in cement mortar 1:4 complete with joints to match, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed by the Engineer-in-Charge.
M&L 16 to 18 mm thick prelaminated particle board exterier grade (grade-1) confirming IS 14587, fixed with nails for kitchen cupboard and cabinet ,shelves for cupboard including 3mm thick 2nd class hardwood leeping patti on cut edge of boards complete all as specified and as directed by the Engineer-in-Charge.
S & F continuous (paino) hinges , width of flaps 30mm (when open) mild steel bright finish or electro galvanished complete all as specified and as directed by the Engr-in-charge.
S&F 100 mm long fancy type stainless steel handle complete all as specified and as directed by the Engineer-in-Charge.
S&F magnet catcher fixed in cabnet shutter (one portion) and wooden frame (other portion) with screw complete all as specified and as directed by the Engineer-in-Charge.
M&L broken bricks hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells, complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete with joints to match complete all as specified and as directed by the Engineer-in-Charge.
M&L Machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness grade M-40 with grey cement and pigments over and including a layer of sand cushioning, 30 mm thick complete all as specified and as directed by the Engineer-in-Charge.
Dismantiling timber framed work scantling 40 Sqm cm and over in section and in any position complete all as specified & directed by the Engr-in-Charge.
S&F box type using ERW hollow 'P' section ventilators glazed/gauged including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing vitreous china urinal partition slabs terminating about 40cm above floor line ,white of size 310 x 700mm including fixing to wall with 60mm long brass screws complete all as specified and as directed by the Engineer-in-Charge.
M&L concrete bed to drain pipes of bore 110mm including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports complete all as specified and as directed by the Engineer-in-Charge . Note:-(i) Thickness of bed belew barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
M & L cutting into existing manholes for connecting new drain, making good to pipe 110 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
M & L stack clamp out of 50mm x5mm flat iron stays including bolt and nuts and securing ends of stays to walls or roof for 75mm bore pipe complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating over area not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in columns, pillars, posts and struts complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
Formwork to sides of pillars, posts,struts, piers, columns and stanchions flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits and sides of roof beams,lintels over 1.5 metre span for rough finished surfaces of concrete flats complete all as specified and as directed by the Engineer-in-Charge
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed by the Engineer-in-Charge.
Surface dressing not exceeding 15 cm deep in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and applying neat cement slurry @3 Kg/Sqm complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic light shade tiles 1st quality (square/rectengular), 10mm thick, area of each tile not exc 0.36 sqm as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic light shade tiles 1st quality (square/rectengular), 10mm thick, area of each tile not exc 0.36 sqm as in skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic light shade tiles 1st quality (square/rectengular), 10mm thick, area of each tile exc 0.42 sqm and not exc 1.00 sqm as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic light shade tiles 1st quality (square/rectengular), 10mm thick, area of each tile exc 0.42 sqm and not exc 1.00 sqm as in skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by Engineer-in-charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill made from 10 mm mild steel square bar as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick pin headed type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single ( single 'T' ) equal or unequal with access door complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) junction single ( single 'T' ) equal or unequal with access door complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) for doors,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. Note : (a). Glazing shall be measured and paid separately; (b). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (c). The rates quoted shall be inclusive of neoprene beading, glazing clips, jointing clips, screws, etc as required and the same shall not be measured for arriving the weight; (d). The rates shall be inclusive of locking arrangement including complete packing with silicon gel alround contacting surface of aluminium framework and including matching the existing surface area complete all as specified and directed.
S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
S & F GI Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint complete for all heights as per specifications including 4mm thick HPSC pre-prime non asbestros fiber cement building board (E-classic or equivalent) decorateive finish fixed to frame work with holding down clips in false ceiling complete all as specified and as directed by the Engineer-in-Charge.
Complete removing of existing treatment on wall by scrappers or any other means and washing , rubbing down and stooping and applying two coats of Acrylic (oil bound) distemper using painting roller over and including 2mm thick wall care putty in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing old decorated plastered wall surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
S & F 5mm PVC hollow sheet (the thicknees of inner wall 0.7 to 1.00mm) wall panelling inclusive of solvent cement and fixing at site with U clip or PVC frame as per specifications and drawing complete all as specified and as directed by the Engineer-in-Charge.
M&L 12 mm thick prelaminated partical board interior grade prelaminated both side with decorative choice lamination fixed with screw to timber frame work/aluminium frame work as in repair complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered wall surfaces and applying three coats of white lime wash on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'B' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, ceiling rose etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 181 here-in-above but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 181 here-in-above but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per srl item No 181 here-in-before but for one socket outlet 15 Amp with 2.5 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.5 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description same all as per srl item No 181 here-in-before but for one socket outlet 15 Amp with 4 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined , 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 3/3 pin combined (6 pin) , 16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fix lamp holder,PVC/ polycarbonate type, with back plate for angular batten fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED Bulb, pin type 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push 6 Amp, 1 way, 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply & fix calling bell ding dong AC 230 volt complete all as specified and as directed by the Engr-in-charge.
Supply & fix as in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C'series complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 12 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and fix in reapir over and low voltage release 230 volts, single phase in one module, suitable for (1 Ph+n) AC, adjustable for 170volts to 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fixing LED tube light fitting, 4 feet box type 1x18/20 watt with opal diffuser, aluminium housing body suitable for LED tube, AC 220-240 volts, 50 Hz and including 1x18/20 watt LED tube rod, driver, connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge.
Material & labour as in repair for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coated with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade as in repair complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L for sand cushoning under the cable for protecting the cable being damaged from external load complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts as in repair complete all as specified and as directed by Engineer-in-Charge
Supply and fix sheet metal MCB DB TPN 4 way with 200 Amps rated bus bar trripal pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and fix TV modular socket 2/3 pin,1 way 2 module of complete all as specified and as directed by Engineer-in-Charge.
M & L rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction /terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades scrapping old paint, cleaning , washing with washing powder and applying two coats of painting on ceiling fans with synthetic enamel paint by spraying incl filling cavaties with filler, writing MES No. on ceiling fan and reassembling the same and hanging the ceiling fan in same position, making all electrical connection using 3 core copper flixible cable and testing complete all as specified and as directed by the Engineer-in-Charge.
S&F step type electronic Fan regulator modular 120 watt, 2 module complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing testing and commission isolator DP, 240 volts, 32/40 Amp, AC 50 Hz, connected with suitable lugs complete all as specified and as directed by the Engr-in-charge
Supply and fixing testing and commission isolator TPN, 415 volts, 4 pole, 63 Amp, AC 50 Hz, connected with suitable lugs complete all as specified and as directed by the Engr-in-charge
S&F mirror light 9/12watt LED wall mounting fixture, one feet , aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Taking down unserviceable MCB DB alongwith MCCBs/MCBs and MCB DB plug & Socket Boards alongwith MCBs of any description and making good the disturbed surfaces of walls and paint tuch up to match with existing finishes as per site requirement complete all as specified and as directed by Engineer-in-Charge..
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard, copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Supply & fix double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C'series complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable 10 sqmm PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 20 Amps, 240 volt,10 KA, 'C' curve complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps, 2 Pole, 2 module, 300 mA (HI immunity) sensitivity 230 volts 50 Hz, as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral (VTPN) with TPN MCCB 100 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S&F LED 22 watt integrated batten with inbuilt lithium ion battery with minimum 4 hour back up including removing of unservicable light fitting complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED flat panel 2' x 2' size fully difused surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable to light fitting as in repair complete all as specified and as directed by the Engr-in-charge.
Supply and fixing LED surface mounted bulk head luminaries 1x8-10 watt with min 800 lumen, industrial model, IP 65, aluminum housing, surge protection including driver & LED lamp etc complete with all accessories connecting with three core copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
shiv const co
Durga Enterprises
Sham Sunder Bansal
M/s Vridhi Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .