Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC L1 being lowest | |
| 2 | L2₹18.9 L+₹15,090 (0.80%)Rejected-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L2 | Rejected-AOC being not lowest | |
| 3 | L3₹20.7 L+₹2.0 L (10.4%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-AOC being not lowest | |
| 4 | L4₹23.7 L+₹5.0 L (26.4%)Rejected-AOC | L4 | Rejected-AOC being not lowest |
Tender Value
₹24.8 L
EMD Value
₹49,600
Closing Date
9 Feb 2021, 6:00 pmClosed
CWE Hills Dehradun
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003
REPAIR AND REPLACEMENT OF GI CI PIPE LINES VALVE AND OTHER ALLIED WORKS IN OTM ACCN AT MIL STN RAIWALA AND NARENDRA NAGAR UNDER AGE I RAIWALA
2021_MES_413193_1
86302/RWL/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Raiwala
₹49,600
Yes
4 Mar 2021
16 Jan 2021
11 Feb 2021
16 Jan 2021
9 Feb 2021
27 Jan 2021
18 Jan 2021 - 25 Jan 2021
Amount
Excavation in trenches in hard /dense soil n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation laying of pipe etc n.exc 10 sqmm on plan and n.exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-charge
Returning filling in including spreading levelling watering and well ramming in layers not.exc 25cm each layers complete all as specified and as directed by Engineer-in-charge
Removal of excavated material & surplus spoil to a distance n.exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-charge
Taking up cast iron water mains of 100mm bore including all fittings with spigot and socket end and lead joints including burning out joints and recovering lead complete all as specified and as directed by Engineer-in-charge
All as per above item No 4 above but 150mm bore complete all as specified and as directed by Engineer-in-charge
All as per above item No 4 above but 200mm bore complete all as specified and as directed by Engineer-in-charge
All as per above item No 4 above but 300mm bore complete all as specified and as directed by Engineer-in-charge
Cutting to cast iron pipes of 80mm bore before laying in position for insertion of new tees, branches, bend and new connection etc complete all as specified and as directed by Engineer-in-charge
All as per above item No 8 above but 100mm borecomplete all as specified and as directed by Engineer-in-charge
All as per above item No 8 above but 150mm bore complete all as specified and as directed by Engineer-in-charge
All as per above item No 8 above but 200mm bore complete all as specified and as directed by Engineer-in-charge
All as per above item No 8 above but 300mm bore complete all as specified and as directed by Engineer-in-charge
Supply and fix ductile iron spun pipes of 100 mm bore with flange end centrifugally cast class K-7, conforming toIS:8329 ISI marked in any length laid in trenches complete with gaskets/ nut bolts all as specified and as directed by Engineer-in-charge
All as per above item No 13 above but 150mm bore complete all as specified and as directed by Engineer-in-charge
All as per above item No 13 here-in-before but 200mm bore Class K-9 complete all as specified and as directed by Engineer-in-charge
S&F in repairs ductile iron fittings flang and socketed / all socketed / all flanged type such as bend upto 300mm bore (any type radious and angle) tapers any type (straight, bend, increasing, descreasing or double socket etc), Tee piece single branch, 'Y' junction, double branch cross (all sockets or socket and spigot) collors, caps and plugs complete all as specified and as directed by Engineer-in-charge. Note :- excavation earth work and run lead joints, tighten joints, rubber gasket shall be measured and paid seperately.
S&F in repairs unserviceable cast iron fittings flang and socketed / all socketed / all flanged type such as bend upto 300 mm bore (any type radious and angle) tapers any type (straight, bend, increasing, descreasing or double socket etc), Tee piece single branch, 'Y' junction, double branch cross (all sockets or socket and spigot) collors, caps and plugs complete all as specified and as directed by Engineer-in-charge. Note :- excavation earth work and run lead joints, rubber gasket shall be measured and paid seperately.
S&F testing and connecting cast iron sluice valve heavy duty double flanged, 300 mm dia PN 1.6 confirming to IS 14846: 2000 ISI marked with Stainless steel spindle and two nos of MS flange of 16mm thick, 8 holes with nuts and bolts packing materials complete including cutting the existing watermain for fixing cast steel sluice valve and jointing welding complete required at site of water supply installations complete all as specified and directed. Make:- Kirloskar/L&T/Bir/ Zoloto
All as per above item No 18 above but 200mm bore complete all as specified and as directed by Engg-in-Charge.
All as per above item No 18 above but 150mm bore complete all as specified and as directed by Engg-in-Charge.
All as per above item No 18 above but 100mm bore complete all as specified and as directed by Engg-in-Charge.
All as per above item No 18 above but 80mm bore complete all as specified and as directed by Engg-in-Charge.
S&F jointing to cast iron pipe of size 300mm bore spigot and socket by run lead joints including spun yarn and caulking of lead joints complete all as specified and as directed by Engineer-in-charge
All as per above item No 23 above but 200mm bore complete all as specified and as directed by Engg-in-Charge.
All as per above item No 23 above but 150mm bore complete all as specified and as directed by Engg-in-Charge.
All as per above item No 23 above but 100mm bore complete all as specified and as directed by Engg-in-Charge.
All as per above item No 23 above but 80mm bore complete all as specified and as directed by Engg-in-Charge.
Taking up or down existing GI pipe 80mm dia from trenches / walls / roof / floor etc including connection and cleaning for refixing or removal and making good to distrubed area (surface of walls / floor etc) complete all as specified and as directed by Engineer-in-charge.
All as per above item No 28 above but size 50mm bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 28 here-in-before but size 40mm bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 28 here-in-before but size 25mm bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 28 here-in-before but size 20mm bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 28 here-in-before but size 15mm bore complete all as specified and as directed by Engineer-in-charge.
S&F GI tubing medium grade 80mm dia with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge. Make- Swastik / Jindal / TATA
All as per above item No 34 above but size 50mm dia bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 34 above but size 40mm dia bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 34 above but size 25 mm dia bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 34 above but size 20 mm dia bore complete all as specified and as directed by Engineer-in-charge.
All as per above item No 34 above but size 15 mm dia bore complete all as specified and as directed by Engineer-in-charge.
Cutting and screwing to existing MS / GI steel tubing for alteration or addition to pipe line of 40 to 50mm bore with new fittings and fixtures complete all as specified and directed by Engineer-in-charge.
All as per above item No 40 here-in-before but size 80mm dia bore complete all as specified and directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve (ISI Marked) with iron wheel head screwed both ends for iron pipe 50 mm dia complete all as specified and as directed by Engineer-in-charge.
All as per above item No 42 above but size 40 mm dia bore complete all as specified and directed by Engineer-in-charge.
All as per above item No 44 above but size 25 mm dia bore complete all as specified and directed by Engineer-in-charge.
All as per above item No 42 above but size 20 mm dia bore complete all as specified and directed by Engineer-in-charge.
All as per above item No 42 above but size 15 mm dia bore complete all as specified and directed by Engineer-in-charge.
S&F in replacement cast iron non return valve flanged end conforming to IS 5312 of size 300 mm dia (ISI Marked) complete with rubber flange, MS nuts & bolts complete all as specified and as directed by Engineer-in-charge.
All as per above item No 47 above but 200mm dia complete all as specified and as directed by Engineer-in-charge.
All as per above item No 47 here-in-before but 150mm dia complete all as specified and as directed by Engineer-in-charge.
S&F in replacement cast iron air release valve flanged end conforming to IS 5312 of size 200 mm dia complete with rubber flange, MS nuts & bolts complete all as specified and as directed by Engineer-in-charge. Make- RMCO/ Kirlosker/ZOLOTO
M/s RP AGRAWAL
VIJAY ENTERPRISES
janta tradrers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .