Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.2 LAccepted-AOC | 1 | Accepted-AOC Low Cost and L1 | |
| 2 | 2₹7.5 L+₹32,060 (4.47%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹8.0 L+₹81,066 (11.3%)Rejected-Finance COIMBATORE ROAD KALMADAPOM PALAKKAD | PALAKKAD | 3 | Rejected-Finance L3 High Cost |
Tender Value
₹8.2 L
EMD Value
₹20,400
Closing Date
24 Aug 2020, 3:00 pmClosed
Secretary Engandiyur GP
Engandiyur Gramapanchayath,Pokkulangara P.O,PIN 680691
SUPPLY INSTALLATION AND COMMISSIONING OF 30 KVA D.G. SET FOR THE OFFICE OF ENGANDIYUR GRAMAPANCHAYATH
2020_DP_376326_1
EngSec03/2020
Open Tender
Equipments
Item Rate
30 days
Engandiyur Grama Panchayath
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,850
online
₹20,400
Yes
15 Sept 2020
12 Aug 2020
26 Aug 2020
12 Aug 2020
24 Aug 2020
12 Aug 2020
30 KV Genator
SUPPLY INSTALLATION AND COMMISSIONING OF 30 KVA D.G. SET FOR THE OFFICE OF ENGANDIYUR GRAMAPANCHAYATH Supply, conveyance and unloading of 30 KVA D.G. set with company made acoustic canopy conforming to CPCB. Norms as per technical details given below Engine Make of Engine- Type of Engine- X27 TAAG3 No. of Cylinders- suitable to develop the required BHP as per manufacture’s standards Method of cooling- Water cooling with radiator Aspiration – Turbo charged/ Natural Design - Suitable for Generator set application Out put-40 BHP at 1500 Rpm under NTP Standard Accessories with diesel Engine Flywheel to suit coupling Close Coupling Air Cleaner Fuel Pump Mechanical Governer Fuel filter Lubricating Oil Filter Residential type exhaust Silencer Engine Instrumental Panel Starting Switch key/Button Lubricating Oil Pressure gauge Water temperature gauge RPM indicator with hour meter Supply Control for Engine Battery Control (Trip) for low lubrica ting oil Pressure Battery control trip for high water temperature Providing necessary warning system and other safties as contemplated in relevant ISS Fuel Pipe Oil Resistant Hoses of 25 mm dia or Nearest MS Pipe as per manufactures requirement for fuel line Alternator Type – Self exited and self regulated Capacity 30 KVA 24 KW @ 0.8 P.F lag System Voltage – Three phase, 415 V AC, 50 Hz Speed – 1500 RPM Voltage regulation – 25% of rated voltage Insulation Class – F/H Alternator should confirm IS 4722 The DG set should mount on a suitable size base frame with antivibration mounting pad Fuel Tank 85 L Capacity fuel tank integrated with acoustic enclosure complete with fuel piping, Provision for filling the diesel, electric fuel gauge Battery Required no of suitable rated fully charged battery with leads and terminals as required as per manufactures requirements (65 Ah) Operation Manual, service manual, List of spares etc shall be submitted while the DGS set is supplied Standard Control panel integral with the acoustic enclosure comprising of the following 100A, 25 KA, 4 Pole MCCB having adjustable setting, having connection with statutory protective system like EFR and neutral CT etc- Digital type meter with accuracy class 0.5 to read parameters such as KWH, Viltage, Current, Frequency etc LED Type phase indication type Fuse Protection shall be Provided for the meters and indication Lamps Acoustic Size Length 2400 Width 950 Height (without silencer) 1400 Weight 1110 Kg Exhaust Piping 70 mm (2.5 inch) The cost of DG Set shall be inclusive of all taxes and duties conveyance charges and unloading at site With 40 Ltr disel,and please read the specification for installtion of work
SANKARANKUTTY.K
Horrizon
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .