| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | ₹26.7 L Quoted ₹27.5 L | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹29.3 L+₹1.8 L (6.54%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹29.3 L+₹1.8 L (6.54%) | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹29.7 L+₹2.2 L (7.94%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹29.7 L+₹2.2 L (7.94%) | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹29.9 L+₹2.4 L (8.58%)Rejected-Finance FLAT NO 304 AKASHDEEP APARTMENT SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJASTHAN | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | ₹29.9 L+₹2.4 L (8.58%) | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 5 | L5₹30.9 L+₹3.4 L (12.4%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹30.9 L+₹3.4 L (12.4%) | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
24 Sept 2024, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA, GUJARAT-390022
REPAIR REPLACEMENT OF INTERNAL ELECT DB SUBMAIN WIRING AND REPAIR MAINTENANCE OF CEILING FAN EXHAUST FAN GEYSERS AT DARJIPURA AT AFS VADODARA
2024_MES_661573_2
8898/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
GE (AF) BARODA
AS PER NOTICE OF TENDER
6 documents required · 6 mandatory
₹500
Yes
GE (AF) BARODA
₹58,000
Yes
21 Oct 2024
3 Sept 2024
26 Sept 2024
3 Sept 2024
24 Sept 2024
10 Sept 2024
3 Sept 2024 - 10 Sept 2024
Amount
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs complete all as specified and directed
M&L for point wiring with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade (conforming IS 694) in and incl not less than 2mm thick PVC casing/caping ISI marked, with all accessories including one run of 1.5 Sqmm multistrand PVC insulated FRLSH stranded copper conductor cable (green colour) for earth continuity conductor to common earth dolly including all other required accessories as specified in Preamble 1 (a) to (q) of section 19 of SSR Part-II under heading "Point wiring'". fixed on walls/ceiling including PVC box surface/ flush type SS sunken boxes with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc complete covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed & making good to disturbed surface of wall to match with the existing finish etc for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One bell point controlled by one way switch
One light point controlled by two way switches
All as per item No 2 here in before but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed FRLSH 2.5 Sqmm on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed.
All as per item No 2 here in before but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed FRLSH 4 Sqmm on independent board including one run of 4 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed.
Material and labour for point wiring for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in existing concealed PVC conduit (medium grade) of 20mm dia/as exist on site all as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel box including modular cover plate for mounting modular switch socket etch incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed.
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One bell point controlled by one way switch
One light point controlled by two way switches
All as per item No. 5 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board.
All as per item No.5 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
M & L for sub main wiring using with FRLSH cable two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed including taking down existing sub main wiring complete all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of 6 sqmm earth wire and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
M & L for sub main wiring using with FRLSH cable two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed including taking down existing sub main wiring complete all as specified directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth wire and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
Note:(for item 02 to 9): (i) The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at Darjipura Main receiving station to carry out maintenance within stipulated time without fail (ii) The quoted rates shall deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (iii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperately under respective item of Sch’A’. (iv) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade)
S&F modular switch one way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&F modular switch one way 16 Amps 1 module 240 Volts. Complete all as specified and directed
S&F modular switch two way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&F modular bell push way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&f modular socket outlet 6A 3 pin 2 module 240 Volts. Complete all as specified and directed
S&f modular socket outlet 6/16A 5 pin 2 module 240 Volts. Complete all as specified and directed
S&f modular fan regulator 120 W 2 MODULE 240 Volts complete all as specified and directed
S&F in repair switch piano flush type single pole one way 5 Amp 240 Volts. Complete all as specified and directed
S&F in repair 5 Amps Socket only 3 Pin flush type Complete all as specified and directed
S&F in repair 15 Amps Switch only 3 Pin flush type Complete all as specified and directed
S&F in repair 15 Amps Socket only 3 Pin flush type Complete all as specified and directed
S&F in repair switch socket combination 2 in 1, 3 pin, 5 Amps flush type universal type 240 Volt. complete all as specified and directed
S&F in repair switch socket combination 2 in 1, 3 pin, 5 and 16 Amps flush type universal type 240 Volt. complete all as specified and directed
S&F in repair switch piano flush type single pole two way 5 Amp 240 Volts. complete all as specified and directed
S&F in repair switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt. complete all as specified and directed
S&F in repair Stepped/socket type electronic fan regulator heavy duty type A/C 240 V.complete all as specified and directed
S&F in repair Bell push flush type single pole 5 Amp 240 Volts. complete all as specified and directed
S&Fin repair modular switch one way 6 Amps 1 module 240 Volts complete all as specified and directed
S&F in repair modular switch one way 16 Amps 1 module 240 Volts. Complete all as specified and directed
S&F in repair modular switch two way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&F in repair modular bell push way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&F in repair modular socket outlet 6A 3 pin 2 module 240 Volts. Complete all as specified and directed
S&F in repair modular socket outlet 6/16A 5 pin 2 module 240 Volts. Complete all as specified and directed
S&F in repair modular fan regulator 120 W 2 MODULE 240 Volts complete all as specified and directed
S&F in repair Bell ding dong type, one way, 240 volts, AC, ISI marked.complete all as specified and directed
S&F in repair ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. complete all as specified and directed
S&F in repair straight / Angle lamp holder PVC body complete all as specified and directed
S/F in repair Load line 4 way load line segrigated Vertical type(VTPN DB) DB double door, duly powder coated 415 volt with provision for 125 Amps MCCB as incomer and 200 Ams rated bar FP as incomer and SP/TP as outgoing complete all as specified and directed Note: MCCB shall be measured and paid separately under respective item of BOQ.
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 12 way DB 240 volts, 100 Amp rated bus bar. complete all as specified and directed
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 08 way DB 240 voilts, 100 Amp rated bus bar. complete all as specified and directed
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 04 way DB 240 voilts, 100 Amp rated bus bar.complete all as specified and directed
S/F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps. complete all as specified and directed
S/F in repair MCB's SP 40 Amp to 63 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings complete all as specified and directed
S/F in repair MCB SP & N up to 63 Amp 240 Volts C Curve complete all as specified and directed
S/F in repair MCB four pole up to 63 Amp 415 Volts C Curve complete all as specified and directed
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
Description all as per item No 45.00 here-in-before but for size 175x100x50 mm deep
Description all as per item No 45.00 here-in-before but for size 200x150x50 mm deep
Description all as per item No 45.00 here-in-before but for size 250x200x50 mm deep
Description all as per item No 45.00 here-in-before but for size 350x200x50 mm deep
Supply and fix single phase electronic meters temper proof LCD display with polycarbonate cover 230 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
Supply and fix three phase electronic meters temper proof LCD display with polycarbonate cover 415 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified and directed
Supply and fixing recess mounted down lighter 6 Watts complete all as specified and directed yellow/white AS Per Sample complete all as specified and directed
Supply only LED bulb Lamp 09 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.
Supply only LED bulb Lamp 12 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.
Dismantling the Geyser of any capacity and of any description and material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , ‘U’ assembly etc. with brush, cleaning rod, and using / circulating concerned de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of engineer-in-Charge complete all as specified and directed.
Taking down and refixing storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge. Note :- Supply only for parts such as Heating element, Thermostate against unserviceable parts shall be measured and paid for separately under relavent items given below.
All as per item No. 60 here in before but for Geyser of capacity 50 Ltrs complete all as specified and directed.
Supply only heating elements, 1.5/2 KW any type any size ISI mark 230 volts complete all as specified and directed.
Supply only replacement of thermostat immersion point type 15 Amps, 230250 volts/AC ISI marked complete all as specified and directed.
Supply & fix in replacement ,stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement all as specified and directed.
Supply & fix for replacement of indicator lamp assembly for geyser complete all as specified and directed.
Supply and fix in repair syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.
Supply and fix in repair geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.
Supply and fixing 15 Amp plug top complete all as specified and directed.
Supply and fixing earth industrial plug top for socket for industrial socket metal glad suitable for 20 Amps metal glad MCB Dbcomplete all as specified and directed.
Supply and fixing earth industrial socket metal glad suitable for 20 Amps 240 volts metal glad MCB DB complete all as specified and directed
Supply only FR electrical insulation tape nominal size 0.125mm thickness x1.8 cm width x15 mtr length as IS CODE 1728 As per sample complete all as specified and directed
Supply and fix 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances. Role of 90 RM complete all as specified and directed.
Supply and fixng Hylum sheet Size 7” x 9”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete of the following sizes fixed in repairs complete all as specified and directed.
Supply and fixng Hylum sheet Size 9” x 6”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete of the following sizes fixed in repairs complete all as specified and directed.
Supply and fixng Hylum sheet Size 6” x 6”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete of the following sizes fixed in repairs complete all as specified and directed.
Supply and fixng Hylum sheet Size 9” x 11”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete of the following sizes fixed in repairs complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply and fix exhaust fan, steel body AC single Phase. 230 V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed
M&L for painting enamel white paint by spraying on ceiling fans/exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavities with fine finishing surface by filler one coat after removing/cleaning all dust/dert etc including taking down/ refixing complete all as specified and directed Note:- marking/ numbering with MES No/ Qtr no included in item rates, no extra payment shall be made for marking /numbering.
M&L for attending complaint such as No light/loose connection/mcb tripping/ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/dismantling/loose connection etc complete all as specified and directed
Supply and fixing capacitor of 2.5 MFD of ISI marked complete all as specified and directed.
M & L for rewinding of ceiling fans 1200/1400mm sweep, taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of Exhaust fan 300 mm sweep,taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of Exhaust fan 450 mm sweep,taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of Cabin fan 400 mm sweep, taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of air circulator 600 mm sweep,taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warwanty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
S & F MS clamps (Standard size as per site) with rubber real with MS nut, bolts, check nut & split pin complete all as specified and directed
S & F anti suicide fan rod as per sample complete all as spcified and directed .
M&L for changing of fan bearing 6201/6202 of ceiling fan of any capacity any size all as specified and directed. Make SKF/NBC Note: Replacement of bearing to be carried out at power house at AFS Darjipura only exceptional case where lathe work is required then only fan to be taken at workshop.
M&L for changing of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size all as specified and directed Make SKF/NBC Note: Replacement of bearing to be carried out at power house at AFS Darjipura only exceptional case where lathe work is required then only fan to be taken at workshop.
Overhauling/serviceaing of ceiling fans 1200/1400mm, Exhaust fan,wall mount fan any size/ any capacity dismantling and removal of such plant with, duly washed /cleaned overhauling, greasing,remove the derts sludge from the surface/inner vessel servicing the plant and refixing at site complete all as specified and directed . Note: Each plant should be mesured and paid separately .
Supply and fix 23/.0076 sq mm 2 core flexible copper cable for maintenance (Role of 90 RM) complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed
Supply and fix electric wall fan high speed 3 speed control complete with all accessories required to fix on wall etc complete all as specified and directed.
Supply and fixing LED bed side light fitting (bed side reading light) 3 watt as per sample complete all as specified and directed.
Supply and fixing AAA battery for remote hand set complete all as directed.
Supply & fix Exhaust fan louvers 300mm/450mm complete all as specified and directed.
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good,cutting exceeding 20cm girth complete all as specified and directed.
S&F Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
ARTI CONSTRUCTION (BID ID -3110167)
Badri Electricals (BID ID -3109835)
THE SHIVAM ENTERPRISES (BID ID -3098160)
Chanda Construction Co. (BID ID -3098028)
shivalay corporation (BID ID -3109746)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .