| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.5 L+₹3.9 L (11.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹39.9 L+₹4.3 L (12.1%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹43.2 L+₹7.6 L (21.2%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹43.8 L+₹8.2 L (23.2%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Feb 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR AND MAINTENANCE OF ELECTRIC SUPPLY, STREET LIGHT, SECURITY LIGHTS, DOME LIGHT, ALLIED WORKS AND COMPREHENSIVE REPAIR AND MAINTENANCE OF COOLING APPLIANCES AT SEC-09 GANDHINAGAR AND COMN FLT AHMEDABAD
2024_MES_639194_1
8106/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GANDHINAGAR
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹80,000
Yes
30 Mar 2024
25 Jan 2024
15 Feb 2024
25 Jan 2024
13 Feb 2024
8 Feb 2024
25 Jan 2024 - 7 Feb 2024
Amount
Repair and maintenance of transformer of different capacity as under:- Transformer 500/ 160 KVA carrying out insulation resistant test (HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), filtration test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals & joints, replacement of loose or burnt out gasket & proper sealing of valves etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and removing outdoor transformer after disconnecting HT/ LT cable terminals connections and lowering down from plinth/ platform structure of capacity 160 KVA - 500 KVA and refitting after servicing complete all as specified and as directed by Engineer-in-Charge.
M&L for transportation of transformer to nearest workshop for repair/ replacement of transformer winding and return back for installation in its original position/ location after repairing from workshop upto 500 KVA capacity (Rate is inclusive serviceable transformer rent, only transportation, T&P and manpower) complete all as specified and as directed by Engineer-in-Charge. Note:- Contractor will provide serviceable transformer in place of unserviceable transformer of same capacity till unserviceable transformer return form work shop.
M&L for cleaning bus bar with CRC solution - 2.26, 200ml spray bottle with the help of cotton waste etc complete all as specified and as directed by Engineer-in-Charge.
M&L for rewinding of HT /LT coils with super enameled copper wire/ strips DPC/ super enameled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing/ insulation material in each layer of winding, baking the core assembly with the help of oven duly varnshing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT/ LT bushing studs and closing the tank top cover by fixing nuts, bolts and washers (top cover gasket will be measured and paid for seperately) complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement silica gel breather assembly having iron cap at top & bottom and tighten with suitable size of nuts & bolts filled with silica gel for size of transformer 160 KVA to 500 KVA complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of defective tap changer with tapping arrangement 5% and 7.5% on normal tapping complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old painted surface of steel surface by brushing/ cleaning strain grease/ oily spots with thinner and two coats of spray painting with spray machine to transformer indoor/ outdoor fixed on pole or in Sub STN at different location capacity upto 500 KVA including writing SM No, MES No and capacity of transformer complete all as specified and as directed by Engineer-in-Charge.
Supply & filling transformer oil low viscosity type conforming to IS-335 (Latest revision) for topping up of transformer (having dielectric strength 60 KV with 2.5mm gap) complete all as specified and as directed by Engineer-in-Charge.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil extra exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm, 3 Core. The fault located equipment will be brought at site within 02 hours of Instruction received, failing of instruction panalty per hour of Rs 2000 will be charged complete all as specified and as directed by Engineer-in-Charge.
M&L for defect rectification in LT cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil extra exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 185 Sqmm, 3.5 Core. The fault located equipment will be brought at site within 02 hours of Instruction received, failing of instruction panalty per hour of Rs 1500 will be charged complete all as specified and as directed by Engineer-in-Charge.
Dehydration/ filtration of transformer oil of transformers, of various capacities installed in Sector-09, Gandhinagar & Comn Flt Ahmedabad under GE (AF) chiloda, by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV complete all as specified and as directed by Engineer-in-Charge. Note:- Quoted rates shall be deem to include for following:- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.
S&F in replacement worn out HT terminal with bush (set of 3) of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement worn out LT terminal with bush (set of 4) of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Red/ Yellow/ Blue LED indicating lamp (Set of three lamp), 240 Volts, AC complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Red luminous push button with LED indicating lamp and 1 NC Element complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Green luminous push button with LED indicating lamp and 1 NC Element complete all as specified and as directed by Engineer-in-Charge.
Repairs maintenance of APFC panel of capacity 100KVAR to 200KVAR including replacement of wiring with copper conductor cable with lugs etc calibration of relay, digital meter including testing complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of CT for APFC panel of rating upto 800/5 as existing at site complete all as specified and directed by Engr in Charge.
S&F in replacement of 50 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of 40 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 25 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 12.5 KVAR capacitor duty contactor, 240 Volts, AC coil complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 12.5 KVAR cylindrical capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 25 KVAR cylindrical capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement 12.5 KVAR splendid duty square capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 25 KVAR splendid duty square capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 50 KVAR splendid duty square capacitor, 440 Volts, 3 phase, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs digital voltmeter 0-500 volts of size 96mm x 96mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs digital ampere meter 0-500 volts of size 96mm x 96mm complete all as specified and as directed by Engineer-in-Charge.
Repairs/ servicing to 250 KVA DG set (Make- Kirloskar) including radiator servicing, intercooler servicing, general maintenance work such as belt, valve clearance, hose pipe set, bearing greasing connection of terminal, replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality, and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed by Engineer-in-Charge. Note:- spares required shall be measured and paid separately under respective items as 'Supply only'.
Element fuel filter.
Element lube oil filter.
Corrossion inhibitor.
Fan belt.
Main supply fuel pipe.
Set of O-Ring.
All as per Item No. 31.00 above, but for 82.5 KVA DG Set (for Old HQ SWAC Make- Kirloskar) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
All as per Item No. 31.00 above, but 160 KVA DG Set (for Comn Flt Ahmedabad Make- Kirloskar Green) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
Air filter inner.
Air filter outer.
All as per Item No. 31.00 above, but 20 KVA DG Set, 2 nos (for Comn Flt Ahmedabad Make- Mahindra Power) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
Air filter inner.
Air filter outer.
All as per Item No. 31.00 above, but 10 KVA DG Set (for Sewage lifting pumps Make- Mahindra Power) and replacement of following parts:-
Element fuel filter.
Element lube oil filter.
Air filter inner.
Air filter outer.
Main supply fuel pipe of 10 KVA DG set.
Supply only coolant for cummins DG sets complete all as specified and as directed by Engineer-in-Charge.
Supply only engine Oil 15W40 Valvoline for all DG Sets complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs battery 12 V, 130 AH, complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs battery 12 V, 150 AH/ 180 AH, complete all as specified and as directed by Engineer-in-Charge.
M & L for servicing of AMF Panels for DG Set including internal wiring connections, relay setting, setting of pick up time for auto start of DG Set, arranging the doors of panels by welding to the compartment, rearranging and tightening of lugs for cable connections, cleaning dust by vacumm cleaner, replacing the contactors for Main/DG Supply if found unserviceable testing the DG Set for auto/manual start by running the DG Set for 01 Hrs complete all as specified and as directed by Engineer-in-Charge. Note :- The additional cost for internal wiring, PCB service, lugs and programming of the ckt will be included in this items.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engineer-in-Charge.
M&L in repair for installation of sign boards and acrylic sheet background of size 120cm x 60cm including required supporting material i.e. MS clamps, strips nuts, bolts, washers alongwith lettering with sodium sheet material on acrylic sheet with supply & fixing LED T/L fitting of 25 watts - 02 Nos & wiring complete as required as per sample incl 2.50 mtr long GI pipe -02 Nos and taking down old sign board complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs controller- HMI211 including display, replacing contactors/ connectors and making all electrical connections good and renewed for DG set 250 KVA (Make-Kirloskar or equivalent as approved by GE) complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs controller- GC 1202 Auto Mains failure control Module including display, replacing contactors/ connectors and making all electrical connections good and renewed for DG set 82.5 KVA (Make-Kirloskar or equivalent as approved by GE) complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & commissioning in repairs controller - Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for DG set 20 KVA and 160 KVA (Make-Kirloskar Green or equivalent as approved by GE) complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs PLA relay 24 Volt DC for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs PLA relay 110-220 Volt AC for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in repair 3 Core flexible copper conductor cable of size 2.5 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs Battery charger 24 Volt, 10 Amp (Maxpower or equivelent) for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs SMPS Battery charger 12 Volt, 10 Amp (Maxpower or equivelent) for DG set including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Supply, install, testing & comissioning in repairs Automatic Voltage Regulator (AVR) for DG sets of capacity from 10 KVA upto 380 KVA of existing make including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 400 Amps, 35/ 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 250 Amps, 35/ 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 200 Amps, 35/ 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 160 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 125 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 100 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 125 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 100 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and S&F new MCCB triple pole with neutral, 63 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc. complete all as specified and as directed by Engineer-in-Charge.
Comprehensive Maintenance/ Servicing of existing VCB, 3 phase, 11 KV, 630/ 400 Amps by authorised dealer. The scope of work includes : (a) Opening the VCB detect fault and rectify the fault, Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay and replace if necessary complete all as specified and directed by Engr in charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/ resetting required. (b) Checking of heater mechanism, removing moisture from VCB by heating/petrol, IR value, 14 KV hypotest at site, replacement of locking arrangement & testing for smooth functioning at rated voltage. (c) Making all indicator bulbs and push buttons functional at no additional cost. (d) Making all electrical connections to voltmeter and ameter good and ensure the proper functioning of ameters and voltmeters with proper caliberation/ adjustment of voltage and current of outgoing VCB,s with main Incomer VCB. Note:- (1) The contractor should ensure the proper functioning of VCB's and should approach with authorised dealer for carrying of servicing of breaker periodically & when fault/ breakdown occurs. (2) Contractor shall produce all purchase voucher and test certificate before submitting the RAR. (3) The contractor will be responsible for serviceability of VCB for the entire contract period. (4) Unserviceable spare part will be paid and measured separately under respective items of schedule as 'Supply only'.
Supply only 1 Amp PT fuze (set of three fuzes) complete all as specified and as directed by Engineer-in-Charge.
Supply only tripping coil and close coil for healthy functioning of HT VCB complete all as specified and as directed by Engineer-in-Charge.
M&L for opening the HT 11 KV, Bus bar chamber of HT panel/ VCB, cleaning the HT bus bar, inspect the nuts, bolts, bus bar insulator and tighting/ replace with new one if required and heating up for removal of moisture, record its IR value with the help of 5 KV megger and applying thick coating of Z931 strippex B and Z955 Strippex (SL) of stanvac product for preventing from flush over and fire hazard, including replacement of 3/2 mm thick gasket, closing of all holes and charging the same complete all as specified and as directed by Engineer-in-Charge.
M&L for over hauling and secondary injection of over current and earth fault relay of HT VCB 11 KV panel on each multiple setting, readjustment and calibration the same including testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L for testing of primary injection by artificial load through CTs on each multiple setting of over current and earth fault relay, testing CTs polarities, relay calibration and cordination complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of Potential transformer for VCB's 11000/110 volt, 3 phase, as CG, ABB & C&S including making all electric connections good and making the meters functioning well complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of current transformer for VCB's capacity up to 400/200/5 Amps, 3 phase, as per exising including making all electric connections good and making the meters functioning well complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of master trip relay for 11 KV for healthy functioning of HT VCB complete all as specified and as directed by Engineer-in-Charge.
Visit only for VCB/OCB/Tranformer during fault from manufacturer rep /dealer of existing Make and cheking of VCB rectify the fault, replace the unserviceable material and restore the light complete all as specified and as directed by Engineer-in-Charge. Note: Contractor should responsible for arrange visit from manufacturer rep / authorised dealer when fault occur within two hours otherwise recovery of Rs. 2000/- per hrs to be recoverd.
Comphrensive repair and maintenance of Air Circuit Breaker capacity upto 2000 Amps by cleaning of interphase barriers, Draw out contacts on the circuit breaker and stationary contacts in the cubicle should be cleaned and inspected for overheating, alignment and broken and weak springs. Coat contact surfaces with contact lubricant to ease mating, ensure lubrication is done according to the manufacturer specification, protective relays and circuit breaker trip devices should be inspected and tested according to manufacturer specifications including testing complete all as specified and as directed by Engineer-in-Charge.
S & F in repair ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps including dismantling of old complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.5 mtrs wide and n. exc. 1.5 mtr in depth for laying of electric cables for fixing of poles and stay or for laying pipes (where provided for protection of cables) and getting out trimming the sides forming bottom surface to required level in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm in soft/ loose soil complete all as specified and as directed.
Removal of surplus soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for dry sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and as directed by Engineer-in-Charge. Note:- Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and laying in trenches in road cross/ floors tube galvanished iron light grade with all fittings for protection of cable of following dia/ bore of pipe:-
40mm bore.
50mm bore.
Supply and laying in replacement of HT UG cable, XLPE insulated screened PVC badded (ISI Marked), galvanized steel strip or wire, electric power cable (heavy duty) 11000 Volt grade with stranded aluminium conductor of size 95 Sqmm, 3 Core complete all as specified and as directed by Engineer-in-Charge. Note:- Excavation/ earth work, sand cushioning/ brick protection shall be measured and paid separately under respective items of this Schedule.
All as per Item No. 79.00 above, but of size 120 Sqmm.
All as per Item No. 79.00 above, but of size 240 Sqmm.
Supply and laying of LT UG cable, XLPE insulated screened PVC badded (ISI Marked), galvanized steel strip or wire, electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 Sqmm, 2 Core. Note:- Excavation/ earth work, sand cushioning/ brick protection shall be measured and paid separately under respective items of this Schedule.
All as per Item No. 82 above, but of size 16 Sqmm, 4 Core.
All as per Item No. 82 above, but of size 25 Sqmm, 3.5 Core.
All as per Item No. 82 above, but of size 35 Sqmm, 3.5 Core.
All as per Item No. 82 above, but of size 50 Sqmm, 3.5 Core.
All as per Item No. 82 above, but of size 70 Sqmm, 3.5 Core.
All as per Item No. 82 above, but of size 95 Sqmm, 3.5 Core.
All as per Item No. 82 above, but of size 120 Sqmm, 3.5 Core.
All as per Item No. 82 above, but of size 185 Sqmm, 3.5 Core.
Taking down old unserviceable cable from trenches/ walls/ pipes/ poles etc. complete of size 10 Sqmm to 16 Sqmm including removing old connection of cable complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 91 above, but cable size from 25 to 50 Sqmm.
All as per Item No. 91 above, but cable size from 70 to 95 Sqmm.
All as per Item No. 91 above, but cable size from 120 Sqmm to 185 Sqmm.
All as per Item No. 91 above, but cable size 240 Sqmm. Note for item Nos 79 to 94 above:- Excavation/ earth work shall be measured and paid separately under respective items.
Relaying of serviceable cable retrieved from item Nos. 82 to 90 after cutting into pieces serviceable portion complete all as specified and as directed by Engineer-in-Charge.
Cable of size of 10 to 16 Sqmm.
Cable of size of 25 to 50 Sqmm.
Cable of size of 70 to 185 Sqmm.
Supply & install, testing & commissioning in repairs LT feeder panel box compartmental type, lockable fabrication with dimension 800mm (H) x 500mm (W) x 500mm (D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mm x 40mm x 6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation/ grouting on & including PCC as per site requirement including indicator lamps voltmeter and amperemeter with one set of Aluminium Bus bar 200 Amp Cap and fixing the existing changeover switches into that Panel box and making all incoming outgoing electrical cable connections good by fitting new lugs complete all as specified and as directed by Engineer-in-Charge.
M&L for servicing of sliding door motors of Cap - 3 HP operated on 240 V, 50 Hz with replacing of box set - 04 Nos, mechanical seal - 01 No, cut off switch 01 No, bearing 02 Nos, Air filling in tank complete as per site requirement or as directed by Engineer-in-Charge.
M&L for servicing of sliding door gear boxes by replacing of oil seal - 02 Nos, mechanical seal - 01 No, refilling of lubrication oil 15W40, bearing 02 Nos, complete as per site requirement or as directed by Engr-in-Charge.
S&F in repairs cable jointing kit for 11000 Volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in repairs cable jointing kit for 11000 Volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit for 11000 Volts grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm, 3 Core to 95 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit for 11000 Volts grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm 3 Core to 185 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit for 11000 Volts grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 Sqmm 3 Core to 300 Sqmm 3 Core complete as specified and as directed by Engr-in-Charge.
S&F in replacement of cable jointing kit epoxy type for 1100 Volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 Sqmm 3.5 Core to 120 Sqmm 3.5 Core complete as specified and as directed by Engr-in-Charge.
S&F in repairs cable jointing kit epoxy type for 1100 Volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm 4 Core complete as specified and as directed by Engr-in-Charge.
S&F in repairs cable jointing kit epoxy type for 1100 Volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 16 Sqmm 4 Core complete as specified and as directed by Engr-in-Charge.
Comprehensive Maintenance / Servicing of existing OCB, 3 phase, 11 KV, 630 / 400 Amps by authorised dealer. The scope of work includes : (a) Opening the OCB detect fault and rectify the fault, Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in charge.The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/resetting required. (b) Checking of heater mechanism, removing moisture from OCB by use of heating/petrol, IR value,14 KV hypotest at site,replacement of locking arrangement & testing for smooth functioning at rated voltage. (c) Making all indicator bulbs and push buttons functional at no additional cost (d) Making all electrical connections to voltmeter and ameter good and ensure the proper functioning of ameters and voltmeters with proper caliberation/adjustment of voltage and current of outgoing OCB,s with main Incomer OCB Note: (1) The contractor should ensure the proper functioning of OCB's and should approach with authorised dealer for carrying of servicing of breaker periodically & when fault /breakdown occurs. (2) Contractor shall produce all purchase voucher and test certificate before submitting the RAR. (3) The contractor will be responsible for serviceability of OCB for the entire contract period
M&L for OCB testing charges of primary Inection testing and Hi-pot testing complete all as specified and as directed.
M&L in replacement of OCB incomer Bus connecting Epoxy bushing with shroud as existing capacity complete all as specified and as directed.
M&L in replacement of SITC OCB HT CT 40/ 5A as existing capacity including removing unserviceable CT complete all as specified and as directed.
M&L in replacement and servicing of OCB troly oil changing complete all as specified and as directed.
S&F in repair/ replacement of galvanized steel earth plate electrode of existing size buried directly in ground vertically to a depth not less than 2.25 mtr deep below Ground level with top edge of the plate not less than 1.5 mtr below normal GI earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt earth lead GI earth strips 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and other end of the earth strip connected to test point and protected by GI steel pipe light grade 40mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth work completed all as specified and as directed by Engineer-in-Charge.
M&L in repair for construction of earthing chamber/ pit of internal size 600mm x 600mm in repair and making coping for funel with PCC (1:2:4) type B1 (using 20mm gradded stone aggregates) all with MS angle 40mm x 40mm x 4mm frame work duly painted with all corrosive bituminous paint and including RCC slab 50 mm thick in cement concret (1:2:4) type B1, reinforced with XMP (weight not less than 3 Kg per sqm) having lifting arrangement including dismantling old earthing pit complete all as specified and as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet viterous enammeled white with letters figures and conventional skulls and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20 X 15 cm size complete all as specified and as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet viterous enammeled white with letters figures and conventional skulls and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 X 20 cm size complete all as specified and as directed.
M&L for removing the existing damaged test point terminal block and replacing the same with new test point terminal block made out of gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 hole, 8mm dia, 25mm long hexagonel head with nut and washers etc. complete all as speciified and as directed.
M&L in repair for fixing in position loose/ hanging copper/ aluminium earth strip of any size on wall/ building roof with porcline insulators/ supports of required size complete all as specified and as directed. Note:- Rate of porcline insulator deemed included in rate quoated.
Supply and fix in repair 2.5 Sqmm three core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade from junction box to street light fitting complete all as specified and directed by Engr in Charge.
Lowering of high mast light assembly from 12 to 16 mtr high mast and refixing the complete assembly on 12 to 16 mtr top after repairing and replacing of light any type/wattage incl complete dismantling, checking replacement of unserviceable parts and components as required and make the light fittings operational to give rated illumination incl cleaning the acrylic/glass cover and refixing the same after repair/replacement of spare components complete with necessary electrical connection with two single core 2.5 Sqmm PVC sheathed multistranded copper conductor of required length complete all as specified and as directed. Note :- 1. Spare parts/components shall be measured and paid separately under respective item of sch 'A' . Note:- 2. The greasing of pully, roller, bearing and gear including refixing rope clamp, adjustment of lock, lever etc deemed to be included in the item rate.
Supply and fix in replacement 200 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed.
Taking down carefully existing unserviceable LED Flood light any type and any watt from the pole and existing location to carry the necessary repair like electronic driver,LED, Sarch protection and rewiring the same complete and fixed to existing location including necessary electric connections complete all as specified and directed.
Supply and fixing in repair trailing cable 4 Sqmm, 5 core copper conductor EPR insulated PCP sheathed cable having current carrying capacity 30 Amp complete all as directed by Engr-in-Charge.
Supply and fixing in repair trailing cable connector and terminal box suitable for 16/12 Mtr high mast, make and model as per existing complete all as specified and as directed.
Supply and fix in repair high mast 3 phase, 415 volt integeral motor 2 HP, with one No isolator 4 pole, 63 Amp complete all as directed by Engr-in-Charge. Make : As per existing
Supply and fix in repair electronic driver and surge protection suitable for LED street light fitting of 25 to 120 watt and as per existing fitting complete all as specified and directed.
S&F in repair street light bracket made out of 40 mm bore GI tubing medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole complete all as specified and directed by Engr-in Charge.
Dismantling old unserviceable bending/broken PCC/steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation and earth work as required and removing the same from site and deposite to MES store yard complete all specified and directed.
Supply, erecting and installation of steel tubular swaged pole type 410 SP-31 (9 mtr long), seamless confirming to IS-2713-1980 complete with cast iron base plate, finial taper plug, bolts nuts and screws over all length 9 mtr, bottom portion size 4.5mm thick having 165.10mm outer dia 5mtr long, middle portion 4.5mm thick having 165.10mm outer dia 2mtr long and top portion 3.65mm thick having 114.30mm outer dia, 2 mtr long duly painted internally complete and externally painted with two coats of bituminous paint upto 2.1 mtr from bottom with a coat of red oxide primer including provision of 300mm wide black and yellow alternate strips over 1.5 mtr height above 1.8 mtr height and above the coping. Painting of the remaining external surface after strips to top of the pole with two coats of aluminium paint and numbering of pole by white paint on a black colour of 200mm height complete all as specified and directed by Engineer-in-Charge. Note:- Rates are deemed to be inclusive of necessary earth work for foundation of the poles including PCC 1:3:6 type C-2, coping, formwork.
Supply and fix in repair PVC MCB DB 2 way with MCB SPN 6 to 32 Amps, 230 volts, including taking down of old unserviceable DB complete all as specified and directed by Engr- in -Charge.
S&F in repair PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105 mm including 4 Nos of bus bar strip of aluminium of size 25x4 mm suitable for 440 volts of suitable amps rating including 1 No MCB SPN ,6 to 32 Amps, 230 volts, complete all as specified and directed.
Supply and fix in repair LED Bulb 15 watt complete all as specified and directed by Engr in charge.
Supply and fix in repair LED Bulb 20 watt complete all as specified and directed by Engr in charge.
Supply and fix in repair MCB’s single pole with neutral, 6 to 32 Amps, 230 volts complete all as specifed and directed by Engr-in- charge.
Supply and fix in repair 3 pole power contactor type ML AC 3 rating(100A) Aux Contactors 2NO+2NC Cat No SS90721 of Make- L&T or equivalent as approved by GE compatible with digital timer of suitable capacity complete all as specified and directed by Engr-in- charge.
Supply and fix in repair to timer switch Digital type 24 hours with 15 min and 30 min, 16/100 Amp contact rating 230 volts AC 50 Hzs suitable for street lights and all as specified and directed by Engr in charge. Make : Legrand Cat Part No.CX3 CT 230V 2NO 40 A or equivalent as approved by GE.
S&F in replacement of Milky dome of PVC/ glass body of existing size incl bracket complete all as specified and directed.
S&F in replacement of aviation light including aviation yellow painted die cast aluminum alloy, red colored polycarbonate dome and accessories complete all as specified and directed.
S&F in replacement of die cast aluminimum flood light with high power LEDs as light source of 30 watt, LED fittings pre-wired complete all as specified and directed.
S&F in replacement of die cast aluminimum flood light with high power LEDs as light source of 50 watt, LED fittings pre-wired complete all as specified and directed.
S&F in replacement of flood light luminaries, energy saving, long life, of capacity 100 watt, 6000K pressure dia cast aluminium IP66 LED fitting pre-wired complete all as specified and directed.
S&F in replacement of flood light luminaries, energy saving, long life of capacity 150 watt, 6000K die cast aluminium IP66, high power LED fittings pre-wired complete all as specified and directed.
S&F in replacement new generation, energy saving, environmetal friendly, long life aesthetically designed aluminium landscape Bollard luminaire for diffuser lighting with high power LED of capacity 10 watts round/ square shaped incl bracket with necessery PCC work complete all as specified and directed.
S&F in replacement LED bush and spike light luminaires of IP 65 of 9 watt complete all as specified and directed
S&F in replacement LED post top made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection of 40-45 watt LED complete all as specified and directed
S&F in replacement decorative indirect post top light of 70 watts LED type of IP 65 protection with diecast aluminium body with clear toughned glass diffuser complete all as specified and as directed by Engineer-in-charge .
S&F in replacement LED post top made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection of 25 watt LED complete all as specified and directed
S&F in replacement of outdoor aesthetically designed LED Street Light of capacity 90 watt, with pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07 complete all as specified and directed.
S&F in replacement of outdoor aesthetically designed LED Street Light of capacity 120 watt, with pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07 complete all as specified and directed.
Taking down of old existing MS Clamp and Supply and fix new MS clamps of size 40 x 5 mm in cros sectional area and upto 500 mm in length suitable for fixing the PVC Junction boxes to the street light poles and boundary walls as the case may be, including making necessary holes and nuts/bolts required for fixing the junction box to the poles either steel tubular or PCC Pole or at the boundary wall for post top lights complete all as specified and directed by Eng-In-Charge.
M&L in replacement 30 Watt LED pressure die cast aluminium IP-65 protection road way luminaire with high power LED fix on existing bracket complete all as specified and directed.
S&F in replacement power contactor of capacity 400 amps 4 pole suitable for taking proper balancing load and making sefty for any up down voltage complete all as specified and directed.
All as per item No 152 here in before but 125 Amps.
S&F in repair MCB TPN 32 Amps 415 Volts 10KA complete all as specified and directed.
M & L in replacement of PVC insulated copper wire with one run three core PVC insulated cable copper conductor 1.5 Sqmm drawn through and including 20mm dia PVC conduit from looping box to street light fitting terminal complete all as specified and directed. Note:- Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit
M & L for painting of steel tubular pole 9 mtr long complete and mild steel work such as cross arms, clamps, nuts, bolts, street light brackets etc with one coat of aluminum paint including preparation of old surfaces complete all as specified and directed.
All as per item No 43 above, but garden pole 2.5 meter long.
M & L for painting of PCC pole 9 mtr long complete and mild steel work such as cross arms, clamps, nuts, bolts, street light brackets etc with one coat of aluminum paint including preparation of old surfaces complete all as specified and directed.
M & L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high writing pole no with black paint having existing letter size with the help of stencil cut for letters & figures complete all as specified and directed.
S & F in repair On load change over switch with enclosure 125 A, 415V, complete all as specified and directed.
S & F in repair On load change over switch with enclosure 400 A, 415V, complete all as specified and directed.
M & L for in replacement of mounting bracket forming 'L' shape having an interior angle of 120 degree made out of GI pipe light grade 25 mm dia for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and directed.
M&L for taking down of Acs of split type capacity 1.5/ 2.0 TR from the existing site and taking out filter and servicing the complete in all respact and fixing the same in origanal location, and testing complete all as specified and as directed. Note:- Contractor has to provide blower and jet pump for cleaning and washing of AC, A separate PVC bag will also be provided for collection of waste, mechanic will be responsible to clean the site after servicing.
S&F in repair foam armoar of size 5/8" in repair for AC copper tubing complete all as specified and as directed.
S&F in repair foam armoar of size 1/4" for AC copper tubing complete all as specified and as directed.
M&L for dismentaling and shifting the existing split Acs of cap 1.5/ 2.0 ton to new location complete all as specified and as directed. Note:- Copper pipe will be measured and paid separately under relevant items.
S&F in repair starting capacitor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair starting capacitor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair running capacitor suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair starting relay suitable for existing split AC of cap 1.5/ 2.0 complete all as specified and as directed.
M&L in repair for sub main wiring complete with PVC insulated FR cable of single core 6 Sqmm 660/ 1100 Volts geade with multi stranded copper conductor drawn through existing steel/ PVC conduit concealed or surface/ ceiling and 6 Sqmm unsheathed multi stranded copper conductor as earth wire in green colour complete all as specified and as directed. Note:- Two runs of cable and one run of earth wire shall be measured as one unit length.
M&L in repairs for fabrication stand for (desert coller) by angle iron of size and fixing in to wall at window side for holding of desert cooler with paint on the stand as approved quality, including taking down of desert cooler from ist and 2nd floor of old location and fixing at new palce, complete all as specified and as directed by Engr-in-Charge.
S&F in repair of blower motor for 1.5 TR split AC complete all as specified and as directed by Engr-in-Charge.
S&F in repair cooling coil motor suitable for inverter type AC of cap 1.5/2 TR complete all as specified and as directed by Engr-in-Charge.
M&L for rewinding of blower motor for 2 TR split AC complete all as specified and as directed.
S&F in repair SPN enclouser with a two pin and earth plug and sockets complete with one single pole MCB 20/ 32 Amps cap complete all as specified and as directed.
S&F in repair compressor suitable for existing split type AC 1.5 TR complete all as specified and as directed.
S&F in repair compressor suitable for existing split type AC 2.0 TR complete all as specified and as directed.
S&F in repair condenser suitable for existing split type AC 1.5 TR complete all as specified and as directed.
S&F in repair condenser suitable for existing split type AC 2.0 TR complete all as specified and as directed.
S&F in repair condenser fan blade suitable for split AC 1.5 TR complete all as specified and as directed.
S&F in repair condenser fan blade suitable for split AC 2 TR complete all as specified and as directed.
S&F in repair fan blade (evaporator) suitable for split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair fan blade (evaporator) suitable for split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB suitable for split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB inverter type of indoor/outdoor AC suitable for split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB suitable for split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB inverter type of indoor/outdoor AC suitable for split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair PVC air filter suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair PVC air filter suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair remote controller suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair remote controller suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair swing motor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair swing motor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair condenser motor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair condenser motor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair contactor relay suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair contactor relay suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair copper tube of 16 Sqmm bore complete all as specified and as directed.
S&F in repair copper tube of 12.7 Sqmm bore complete all as specified and as directed.
S&F in repair copper tube of 9.5 Sqmm bore complete all as specified and as directed.
S&F in repair copper tube of 6.3 Sqmm bore complete all as specified and as directed.
S&F in repair drain pipe PVC, 3 mtr in length, suitable for split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair bracket suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair brass valve1/4" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair brass valve1/2" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair brass valve 5/8" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
Supply and filling gas freon (R22/R32) or suitable for existing system complete all as specified and as directed. Note:- (i) Gas bottle to be arranged by contractor. (ii) Labour charges deemed to be included in quoted rate.
S&F in repair acrylic vegetable tray suitable for existing refrigerator of cap 165 to 310 ltr complete all as specified and as directed.
S&F in repair relay with over load protector suitable for existing refrigerator of cap 100 to 310 ltr complete all as specified and as directed.
M&L for repair to body/ base of water cooler 40/ 80 ltr cap ,by replacing the rusted portion with PGI sheet to match with existing body with and incl preparation of surface to smooth finish and duly painted complete with two coats of synthetic enamel paint complete all as specified and as directed.
All as per Item No. 211 above but cap 120 ltr water cooler.
All as per Item No. 211 above but cap 165 to 320 ltr refrigerator.
All as per Item No. 211 above but desert cooler.
M&L for praperation of exterior portion of water cooler 40/ 80 ltr cap to a smooth finish and applying two coats of synthetic enamel paint complete all as specified and as directed.
All as per Item No. 215 above but 120 ltr cap.
Supply and filling refrigerant gas freon R-134A/ R-32/ R-410/ R-407A or as recommended by manifactror Supply and filling Note:- (i) Gas bottle to be arranged by contractor. (ii) Labour charges deemed to be included in quoted rate.
M&L for taking out desert cooler of any size and capacity from existing site for repair and dismentaling of all components from evoparative cooler(desert cooler) metal body very care fully i.e. exhaust fan,motor, Tulu pump, PVC spare parts i.e. distributor, PVC pipe, tee, bend, elbow, holding clamp and any number of nut, bolt, washer, grass paid etc, including praparation of exterior & interior portion on cooler to a smooth finish and applying one coats of bituminious paint and reaasembling the same in existisng position in cooler for smooth running complete all as specified and as directed. Note:- If any warm out items/ parts noyiced during the assembling the same shall be measured and separately under the relavent items.
S&F in repair starting relay suitable for existing refrigerators/ water cooler complete all as specified and as directed.
S&F in repair starting relay suitable for existing deep freezer of cap 120 to 500 ltr cap complete all as specified and as directed.
S&F in repair over load protection suitable for existing refrigerator/ water cooler/ deep freezer of any cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing water cooler 80 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing water cooler 120 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing deep freezer 120 to 500 ltr cap complete all as specified and as directed.
S&F in repair brass chromium plate push cock of 15mm dia complete all as specified and as directed.
S&F in repair cabin bulb 5 Watt for refrigerator complete all as specified and as directed.
S&F in repair cabin bulb holder for refrigerator with cabin brackets complete all as specified and as directed.
S&F in repair thermostat switch for water cooler/ Ref/ deep freezer 40 to 500 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for refrigerator 100 ltr to 195 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for refrigerator 200 to 280 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for refrigerator 292 to 335 ltr cap complete all as specified and as directed.
S&F in repair timer suitable for refrigerator of cap 100 ltr to 195 ltr cap complete all as specified and as directed.
S&F in repair timer/ bio meter/ heater suitable for refrigerator of cap 200 to 335 ltr cap complete all as specified and as directed.
S&F in repair condenser suitable for existing water cooler of cap 40/ 80 ltr complete all as specified and as directed.
S&F in repair condenser suitable for existing water cooler of cap 120 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing water cooler of cap 40/ 80 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing water cooler of cap 120 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing deep freezer of cap 170/ 500 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing refrigerator of cap 100 to 195 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing refrigerator of cap 200 to 280 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing refrigerator of cap 300/ 335 ltr complete all as specified and as directed.
S&F in repair fan blade for desert cooler complete all as specified and as directed.
S&F in repair PVC connection set of three suitable for existing desert cooler complete all as specified and as directed.
S&F in repair cable three core flexible twisted copper conductor of 1.5 Sqmm complete all as specified and as directed.
S&F in repair cable three core flexible twisted copper conductor of 2.5 Sqmm complete all as specified and as directed.
S&F in repair front grill suitable for existing desert cooler complete all as specified and as directed.
S&F in repair grass paid set of three superior quality complete all as specified and as directed.
S&F in repair fan motor 1.0 Ph, 50 Hz, 230 V, AC max amp 1.5 suitable for existing desert cooler complete all as specified and as directed.
S&F in repair water submersible pump 240 V, AC, 50 Hz, 10 Watt, 5 LPM, 2 mtr head complete all as specified and as directed.
S&F in repair ON-OFF switch 5 Amps 240 V for water pump complete all as specified and as directed.
S&F in repair GI shutter as existing at site complete all as specified and as directed.
S&F in repair mounting bracket for fan motor with nut and bolts etc of desert cooler complete all as specified and as directed.
S&F in repair capacitor 4 Mfd + 5% 440 V, MPP 'SH' complete all as specified and as directed.
M&L for taking out water cooler of any size and capacity from existing site for repair and dismentaling of all components from cooler ,very care fully i.e. fan,motor, relay, capacitor and condensor etc, and repair of the same incl servicing and testing, re-fixing complete all as specified and as directed.
S&F in repair PVC conduit suitable for 3.0 core/ 1.5 Sqmm/ 2.5 Sqmm wire incl all fittings for fixing at site complete all as specified and as directed.
S&F 3 pin 15 A top complete all as specified and as directed.
S&F 3 pin 5 A top complete all as specified and as directed.
S&F only casing capping patti suitable for 3.0 core/ 1.5 Sqmm/ 2.5 Sqmm wire complete all as specified and as directed.
S&F in repair AC top plug suitable for existing AC of capacity 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair refrigerator/ deep freezer/ water cooler gasket of suitable size as present at site complete all as specified and as directed.
S&F in repair float valve of desert cooler complete all as specified and as directed.
S&F in repair stop cock of desert cooler complete all as specified and as directed.
S&F in repair PVC inlet pipe superior quality of desert cooler complete all as specified and as directed.
S&F in repair metallic frame for grass holding of superior quality of desert cooler complete all as specified and as directed.
S&F in repair PVC elbow and T of superior quality of desert cooler complete all as specified and as directed.
S&F in repair gas filter and NRV suitable for existing refrigerator and water cooler of cap 40-280 ltr complete all as specified and as directed.
S&F in repair drain pipe for water cooler complete all as specified and as directed.
S&F in repair non-adhesive tape roll for copper tubing of AC complete all as specified and as directed.
M&L for repair of AC water leakage, removing of drain tray cleaning of tray clear all blockage, and refixing the same and make proper insulation and tesing complete all as specified and as directed.
S&F in repair capacitor 2.5 Mfd + 5% 440 V MPP 'SH' complete all as specified and as directed.
S&F in repair capacitor 6 Mfd + 5% 440 V MPP 'SH' complete all as specified and as directed.
S&F in repair line reactor suitable for existing split AC of cap 1.5/ 2. TR complete all as specified and as directed.
S&F in repair contact sensor (indoor/ outdoor/ gas pipe/ temprature) suitable for existing split AC inverter type or non inverter tpe of cap 1.5/ 2.0 TR complete all as specified and as directed.
M&L for taking down outdoor unit of split AC of cap 1.5/2 TR from site, opening the same and segrigate serviceable parts if exist for reuse, and repair to replacement of parts i.e. capillary, valve, outdoor sheet, legs, top cover with stand as existing make as per site and fixing the same, testing complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down of indoor unit of split AC of cap 1.5/2 TR from the wall, opening the same and segrigate serviceable parts if exist for reuse and repair to replacement of parts ie cooling coil, motor, outer body with hanging plate with complete nut and bolt same as existing site and testing complete all as specified and as directed by Engineer-in-Charge.
M&L for dry servicing of Acs of split type or window type capacity 1.5 /2 tr from the existing site and taking out filter and dry servicing the complete in all respact and fixing the same in origanal location and testing complete all as specified and as directed by Engineer-in-Charge. (Note:- Contractor has to provide Blower, Mechanic will be responsible to clean the site after servicing)
(Note:- Mechanic will collect complaint from Eng-in-charge/JE E/M from any mode, complaints of cooling appliances (AC, Ref, Water Cooler, Deep Freezer) and AC Plant should be attended and rectified within 24 hr otherwise a penalty of rupees 2000.00 Rs per day per complaint will be recoverd from the contracter.
TECH SERVE SOLUTIONS
ARTI CONSTRUCTION
Electricals India
ALBA AC AND REF SERVICES
GIRNAR CONSTRUCTION
Ramdev and Sons
DMA PROJECTS
Shree Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .