| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC 38 41 28 104 AREA INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹39.8 L+₹1.4 L (3.74%)Rejected-AOC D NO 44 38 12 23 4 AVS PARADISE SRINIVASA NAGAR AKKAYYAPALEM POST VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹41.0 L+₹2.7 L (7.04%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹41.5 L+₹3.2 L (8.25%)Rejected-AOC DOOR NO 36 72 5 BOOSAVARI STREET REDDY KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹42.4 L+₹4.1 L (10.6%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | ESWAR ENTERPRISES L3 | CHAMUNDESWARI ENTERPRISES L4 | SREE CONSTRUCTIONS L7 | M/S Jayalakshmi Constructions L1 | Sri Venkateswara Constructions L5 | S A R CONSTRUCTIONS L6 | CHAITANYA CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: E/M WORKS | ||||||||||
| 1.00 | Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including suitable size PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point controlled by one switch including taking down the existing old wiring of any description and type complete all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour. | 250 | Point | 880 ₹2,20,000 | 900 ₹2,25,000 | 940 ₹2,35,000 | 820 ₹2,05,000 | 930 ₹2,32,500 | 900 ₹2,25,000 | 710 ₹1,77,500 Lowest |
| 2.00 | Description all as per item No. 1 above but for 5 / 6 Amps switch socket out let, same board complete all as specified | 80 | Point | 710 ₹56,800 | 320 ₹25,600 | 360 ₹28,800 | 280 ₹22,400 Lowest | 365 ₹29,200 | 990 ₹79,200 | 720 ₹57,600 |
| 3.00 | Description all as per item No. 1 above but for 05Amp switch socket out let, independent with 1.5sqmm copper cable of PVC insulated, unsheathed, multi stranded and 1.5 Sqmm for earth continuity conductor, complete all as specified | 60 | Point | 940 ₹56,400 | 960 ₹57,600 | 1,010 ₹60,600 | 850 ₹51,000 | 1,000 ₹60,000 | 920 ₹55,200 | 820 ₹49,200 Lowest |
| 4.00 | Description all as per item No. 1 above but for 15/16Amp switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified | 80 | Point | 990 ₹79,200 | 1,000 ₹80,000 | 1,040 ₹83,200 | 950 ₹76,000 | 1,050 ₹84,000 | 1,000 ₹80,000 | 830 ₹66,400 Lowest |
| 5.00 | Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 25mm surface stove enamel steel conduit on walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete all as specified and as directed. | 10 | Point | 1,050 ₹10,500 | 1,000 ₹10,000 | 1,000 ₹10,000 | 980 ₹9,800 | 1,100 ₹11,000 | 1,040 ₹10,400 | 559 ₹5,590 Lowest |
| 6.00 | Description all as per item No. 6 above but for 15/16Amp flame proof switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified | 5 | Point | 58 ₹290 Lowest | 1,700 ₹8,500 | 1,100 ₹5,500 | 1,600 ₹8,000 | 1,200 ₹6,000 | 1,110 ₹5,550 | 710 ₹3,550 |
| 7.00 | S & F in repairs Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge. | 310 | Each | 64 ₹19,840 | 60 ₹18,600 | 80 ₹24,800 | 55 ₹17,050 | 70 ₹21,700 | 651 ₹2,01,810 | 50 ₹15,500 Lowest |
| 8.00 | S & F in repairs Modular switch 2 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge. | 10 | Each | 71 ₹710 | 90 ₹900 | 95 ₹950 | 70 ₹700 Lowest | 75 ₹750 | 701 ₹7,010 | 90 ₹900 |
| 9.00 | S & F in repairs Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge. | 80 | Each | 69 ₹5,520 | 80 ₹6,400 | 65 ₹5,200 Lowest | 78 ₹6,240 | 80 ₹6,400 | 751 ₹60,080 | 65 ₹5,200 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Sept 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINT OF INTERNAL WIRING FITTINGS AND FIXTURES SUB MAIN WIRING FITTINGS AND OTHER ACCESSORIES AT NAD TECH AREA NAD LIVING ACCN CQAE CNAI DAD DSC n ABE PARK UNDER AGE EM OF GE ND VISAKHAPATNAM
2025_MES_727507_1
8527/GEND/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(ND)Visakhapatnam
₹80,000
Yes
7 Jan 2026
30 Aug 2025
22 Sept 2025
30 Aug 2025
20 Sept 2025
13 Sept 2025
Amount
SCHEDULE 'A' PART-I: E/M WORKS
Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including suitable size PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point controlled by one switch including taking down the existing old wiring of any description and type complete all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 1 above but for 5 / 6 Amps switch socket out let, same board complete all as specified
Description all as per item No. 1 above but for 05Amp switch socket out let, independent with 1.5sqmm copper cable of PVC insulated, unsheathed, multi stranded and 1.5 Sqmm for earth continuity conductor, complete all as specified
Description all as per item No. 1 above but for 15/16Amp switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified
Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 25mm surface stove enamel steel conduit on walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete all as specified and as directed.
Description all as per item No. 6 above but for 15/16Amp flame proof switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified
S & F in repairs Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in repairs Modular switch 2 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in repairs Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in repairs Modular Bell push 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in repairs of modular Fan step regulator, 120W - 1/2 module complete all as specified.
S & F in repairs of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
S & F in repairs of Socket 15A/16A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified.
S & F in repairs ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F in repairs Switch flame proof switch socket and plug combined in LM6 cable termination box in LM6 ,16A 250 volt,2P+earth complete all as specified and directed.
S & F in repairs Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fix P/T switch flush type,5 Amps 240 volts single pole one way.
S/F switch socket combination flush/ box type 2 in 1, 5 amps complete all as specified.
S/F switch socket combination flush/box type 2 in 1, 15/16 amps complete all as specified.
S&F fan regulator electronic type, rotary step, 240 Volt complete all as specified.
S&F in repair Bell push flush type, 5 Amps complete all as specified and directed
S&F in repair calling bell Ding dong, AC 230 volts single pole
S & F 4 feet long LED tube light fittings, retro bar professional WH 5700K to 6200K and 18-20 Watt of cool white / warm comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED tube light rods retro bar professional WH 5700K to 6200K and minimum 18 Watt of cool white with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F 2 feet long LED tube light fittings, retro bar professional WH 5700K to 6200K 9 Watt of cool white / warm comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F 4 feet long LED tube light fittings, retro bar professional WH 5700K to 6200K and 40 Watt of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F square recessed mounted LED light (1'x1') of minimum 1500 Lumens (15 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Square recessed mounted LED light (2'x2') of minimum 3600 Lumens (36 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F recessed mounted LED light (1'x4') of minimum 36 Watt warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Square recessed mounted LED light of round type for Ceiling cutout: Ø 160 mm, height 16 mm, 900 -1200 Lumens (9 - 12 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Square recessed mounted LED light of round type for Ceiling cutout: Ø 210 mm, height 16 mm, minimum 1800 Lumens (18 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F flame proof LED tube light fittings of not less than 40Watt output 5700K, with pressure die cast aluminium housing IP-66 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm all as specified and directed.
S & F LED bulb 15 watts with holder pin/thread type complete all as specified and as directed by the Engineer-in-Charge.
S & F LED bulb 9 watts with holder pin/thread type complete all as specified and as directed by the Engineer-in-Charge.
S & F flood light, 120 W new generation LED with high luminous efficacy, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size incluidng taking down old unsv fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F Highbay light 120 Watt new generation LED with high luminous efficacy, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size incluidng taking down old unsv fittings complete all as specified and as directed by the Engineer-in-Charge. Note : The quoted rate deemed to be work at any height.
S & F Highbay light 150 W new generation LED with high luminous efficacy, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size incluidng taking down old unsv fittings complete all as specified and as directed by the Engineer-in-Charge. Note : The quoted rate deemed to be work at any height.
S & F flame proof LED fittings 60W with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
(Note for sl item Nos 35 36 37 & 38 that the work to be carried out at a ht of 15-20 mtrs and rates quoted to be incl of hiring of heavy duty manupulator suitable for the mentioned ht and ensuring safety of the workers working at that ht. The workers should be covered with suitable insurancy policy by the tenderer and this will deptt will not be liable for any accident while repairing/ replacing the hightbay/ flood lights and rates quoted are deemed to inclu of all the rates to work of specific hts)
S & F Building Security light LED type of minimum 35 W Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing post top lantern LED type 36 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
Supply, installation, testing & commissioning of Single Phase Digital Electronic Meter Hotpressed with and complete all as specified and directed Make: Sintex/Hensel
S & F of SMC Meter box of size 250X250X155mm with viewing glass,concealed hinge and earth bolt plugged complete all as specified and directed
Taking down ceiling fan of any size from its position and doing complete overhauling of fan including 02 no canopy ,and refixing the same after repairs complete all as directed by Engr-in-Charge. .
Supply only Ball bearing for ceiling Fan No 6200 complete all as specified and as directed.
Supply only Gun metal bush suitable for upto1400 mm sweep ceiling Fan, complete all as specified and as directed.
Supply only Hanging clamp and Nut bolt with split pin for ceiling Fan complete all as specified and as directed.
Supply only Fan capacitor of capacity 2.5 mfd epoxy filled type complete all as specified and as directed.
Supply only Fan down rod upto 600 mm complete all as specified and as directed.
Supply only electric insulation tape for insulation at cable joint complete all as specified and as directed.
M & L for painting of Ceiling Fan complete upto 1400 mm sweep with one coat of white paint/existing fan using spray machine painting including cleaning, washing of surfaces complete all as directed.
Supply and fixing Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as directed by Engineer in charge
Taking down Exhaust fan of any size from its position and doing complete overhauling of fan including replacement of fan clamp and split pin, rubber bush, fan capacitor of 4.0mfd and other spare partspainting with synthetic enamel paint over a paint of primer refixing the same after repairs complete all as directed by Engr-in-Charge. .
Rewinding of Exhaust fan motor of sweep upto 380mm & any make ( including flame proof exhaust fan) with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings of suitable size, etc. complete all as specified and directed by Engineer- in -Charge.
Rewinding of Exhaust fan motor of sweep 450mm & 600mm & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings of suitable size, etc. complete all as specified and directed by Engineer- in -Charge.
Taking down existing Air circulator / Pedestal fan of any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler complete all as specified and directed by the Engineer-in-Charge.
Rewinding of pedestal / Air circulator fan motor of sweep upto 600mm & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings, capacitor of suitable capacity etc. complete all as specified and directed by Engineer- in -Charge.
Supply & fix in repairs air ventilator ( PVC Body exhaust fan) 200mm sweep complete all as specified and as directed.
Supply & fix in repairs air ventilator (PVC Body exhaust fan) 250mm sweep complete all as specified and as directed.
S & F in repairs MCCB 4 Pole, 100 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 125 Amps, 50 Hz, 16KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 160 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 250 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as directed
Supply and fixing of Factory made sheet metal MCCB Enclosure suitable for 4 pole MCCB 36KA complete all as specified. (MCCB will be measured and paid seperately.
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 8 Way, with suitable rated bus bar and suitable for having outgoing MCB’s , complete all as specified. (MCCBs and MCBs will be measured and paid seperately.
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 4 Way, with suitable rated bus bar and suitable for having outgoing MCB’s , complete all as specified. (MCCBs and MCBs will be measured and paid seperately.
Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified.
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 12 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified.
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 8 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified.
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified.
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 2 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified.
Supply and fixing in repairs of MCB 16 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing in repairs of MCB 16 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing in repairs of MCB 40 to 63 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing in repairs of MCB 40 to 100 Amp, 415 Volt, TP/TPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing of RCBO DP 30mA, 6 to 32A , 230 Volt, complete all as specified and directed.
Supply and fixing of RCBO DP 30mA, 40A to 63A, 230 Volt, complete all as specified and directed.
Supply and fixing flame WP 6Way MCB DB in Cast aluminum alloy LM-6 construction IP 66 degree of protection, epoxy gray paint with internal and external earthing SS hardware inclusive of MCB's consists of TPN incomming 100A and 8 Nos outgoing 32A TP 3 Nos , 25 A DP 3 Nos & 16 A SP 2 Nos approved by CIMFR complete all as specified and directed by Engr in Charge
M&L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 05 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L circuit wiring with two run of 2.5 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of PVC concealed/surface conduict of suitable size, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
Supply, laying & testing PVC insulated, PVC sheathed cable ,unarmoured, electric control cables with stranded copper conductor of size 10 sqmm 4 core, 1100 Volts grade. Complete all as specified
Supply, laying & testing PVC insulated, PVC sheathed cable ,unarmoured, electric control cables with stranded copper conductor of size 16 sqmm 4core, 1100 Volts grade. Complete all as specified
Supply, laying & testing PVC insulated, PVC sheathed cable ,unarmoured, electric control cables with stranded copper conductor of size 25 sqmm 4core, 1100 Volts grade. Complete all as specified
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 10sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 16sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 25sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
Supply, lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 50sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenchesold site bricks common burnt clay sub class 'B' complete all as specified & directed
Material and labour for 50 mm dia GI steel tubes 'light grade' for cable protection including sealing both ends complete all as specified and as directed by Engineer in charge
Material and labour for cutting existing road/PCC/drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC1:3:6 type CI using 20mm graded aggregates complete all as specified and as directed.
Supply & fix in repair aluminium strip 25 mm x 3 mm Complete with saddles and fixing screws for Fitting the strip.
supply and fix in repair test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws,with frequient opening/closing arrangement etc complete all as specified and directed.
S & F in repairs Wall mounted AC plug and socket distribution box (Industrial socket) including plug connector 32 Amps, 2 pole and earth, IP 40 protection of metal body single phase 240 Volts, 50 Hz with provision for one 32 Amps MCB 2P including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs Wall mounted AC plug and socket distribution box (Industrial socket) including plug connector of 63 Amps, 3 pole, neutral and earth, IP 44 protection of metal body three phase 415 Volts, 50 Hz with provision for one 63 Amps MCB TPN including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs moduler sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC all as specified and directed.
S & F Supply & fix Air Circulator wall mounted fans decorative type 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed by Engg-in-Charge.
S&F of metallic exhaust fan of sweep 300mm Heavy duty along with metallic louver complete including cutting of wall, making of proper hole sufficient to fix exhaust fan and smoothing of the surface before fixing of exhaust all as specified and directed by Engg-in Charge.
S & F in repairs GI powder coated louvers suitable for exhaust fans 300mm sweep including replacing copper conductor wire complete all as directed. Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height
S & F in repairs GI powder coated louvers suitable for exhaust fans 450mm to 600mm sweep including replacing copper conductor wire complete all as directed. Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height
S & F in repairs cable tray of size 100mm width, 50mm depth fixed with and including necessary end joints,T,bends and other accessories, MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable traycomplete all as directed by the Engineer-in-Charge.
M & L for Painting of complete LT Panels of any size and make with existing colour with 2 coats of synthetic enamel spray painting after cleaning of surface by scrubbing all dust particles/ grease/ oil etc and complete all as specified and as directed.
M & L for marking earth resistance check date and value with black bituminus paint as background and " Earthing checked on ___". Earthing resistance value ____ohm" with white synthetic paint of size 450mm x 150 mm complete all as specified and directed by Engr in charge.
M & L for Chemical / mineral earthing by drilling of hole upto 250mm dia to a depth not less than 3.5m and fixed sealed maintenance free chemical filled earthing pure copper electrode 3 m long having the dia of 17.2 mm including supply and installation of earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25kg buried directly and vertically in the hole with top edge not less than 1.25m below normal ground level connected with copper earth strip 20x3 mm by means of bolts, nuts, check nuts and washers of copper connected to earthing test point all as specified or indicated including testing on completion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, refilling the earthing hole including earthing lead upto 7.5m complete all as specified in SSR Part-I and all as per manufacturers instructions.]
M&L Earthing complete with copper plate electrode 600x600x3mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with copper earth strip of 20X3 mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & ,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth strip of 25X4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 20mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
M&L for 20X3 mm copper strip for earthing connection to building, complete all as specified.
M&L for 25x4mm galvanised iron strip for earthing connection to building, complete all as specified.
Supply and fix aluminium strip any hight roof/down conductor of size 25x 3.15 mm for lightening protection complete all as specified and directed.
Supply and replacement of LED driver suitable for LED Light fittings of upto 36-75 watt LED light of any type complete all as specified
Supply and replacement of LED driver suitable for LED Light fittings of upto 75-100 watt LED light of any type complete all as specified
Supply and replacement of LED driver suitable for LED Light fittings of upto 100-150 watt LED light of any type complete all as specified
M&L for 4mm galvanised iron earth wire for earthing connection to building, complete all as specified.
Supply only metal clad plug top 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.
S & F uPVC panel trunking system 75mm width, 75mm depth elongated flexible botom mounting fixed with and including necessary end joints,T,bends and other accessories, MS clamps, nuts, bolts fixed to walls / ceiling complete all as directed by the Engineer-in-Charge.
The rate quoted by the tenderer for item Ser No.01 to 120 above shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- (i) Through the time period for completion of contract will be as specified in CA/work order, yet due to exigency of electrical related items emergency/priority works must be completed (within 24 Hours) on getting information through SMS/E-mail regarding the nature of repair to be carried out he shall immediately respond the same and make all out efforts to carry out the same on priority within 24 hours. In case of any delay in responding/ attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs 100/- per day per each work upto 05 (Five) days and Rs 200/- per day there after till completion of the work. Incase of delay without valid reasons as decided by GE.
(ii) Further, the above penalty is applicable even for the multiple works at multiple locations of work at the same period. It is responsiblity of contractor to make suitable arrangement for attending the repairs simultaneously at all the places. (iii) The decision of the GE as to weather of particular repair has been attended or not on a particular day will be final and binding. The above penality shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e. (Compensation for delay in completion of work). NOTE:- Tenderers/ Bidders are advised to visit the site and quote the rate accordingly.
CHAITANYA CONSTRUCTIONS (BID ID -3430405)
ESWAR ENTERPRISES (BID ID -3429547)
CHAMUNDESWARI ENTERPRISES (BID ID -3430736)
Sri Venkateswara Constructions (BID ID -3430995)
S A R CONSTRUCTIONS (BID ID -3430418)
SREE CONSTRUCTIONS (BID ID -3430752)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .