Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC Since L1 accepted |
Tender Value
₹31.4 L
EMD Value
₹50,000
Closing Date
31 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, HE Electrical Division, Tvpm
Executive Engineer, Harbour Engineering Electrical Division, Kamleswaram. Thiruvananthapuram
Electrification of Harbour Engineering Department Superintending Engineers office at Kamaleswaram
2020_HED_393753_1
24/HEED/2020-21/S
Open Tender
Electrical Works
Item Rate
120 days
Kamaleswaram
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,332
Yes
online
₹50,000
Yes
18 Jan 2021
21 Oct 2020
3 Nov 2020
21 Oct 2020
31 Oct 2020
21 Oct 2020
60 days
Amount
Wiring for light point / fan point/ exhaust fan/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required(Group C)
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required.1 or 2 Module plastic box
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required. 3 Module plastic box
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required. 6 Module plastic box
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mm X 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200 mm X 75mm)
Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc as required.6 module base and coverplate
Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc as required.3 module base and coverplate
Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc as required. 2 module base and coverplate
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amp switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.RJ 11 Telephone jack
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. CAT 6 RJ 45 computer jack
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.RJ 45 frame
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 sq.mm in the existing RCC/ HUME/ METAL pipe as required.
Supply of 4 core 25 sq mm PVC insulated and PVC sheathed armoured aluminium cable
Supply of 4 core 16sq mm PVC insulated and PVC sheathed armoured aluminium cable
Supply of 4 core 6sq mm PVC insulated and PVC sheathed armoured aluminium cable
Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed submersible copper cable
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
Supply and fixing Cable Junction Boxes IP 65 for outdoor applications (Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm ,80 X 80X 52 mm Cape model Abox i025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C x 25 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C x 16 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. upto 4C x 10 sq.mm
Supplying and making end termination nickel plated single compression brass cable gland upto 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable sizes 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make CA43a , 360x270x205mm IP66,IK 10 Glass fibre reinforced polyester enclosure with base plate including supply and fixing 63A , 25kA FP MCCB, with rotary handle, 3 Nos phase indication lamp and 3 Nos 2A SP MCB including wiring using 2.5 sq.mm wire for control wiring .
Supply and installation of Glass Fibre Reinforced Polyester enclosure with Hinged door and 3 point locking IP66 , IK 10 , 600x500x230 mm,BRES -65 -3L CAPE make with baseplate for fixing for fixing CT, KSEB electronic energy meter, cut outs and neutral link. Supply and providing 3 Nos of 63A HRC fuse units with 40A HRC fuse link and 1No 63A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 16.0 sq.mm copper wire.
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle MAIN panel board of size 900 x 2050 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over two coats of epoxy primer, having front openable bolted type vertical bus bar chamber & cable alley covers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following. Incomer:- 63 A, AC 23-A, 4 pole on-load Change Over Switch in open Execution, Incoming:- 63A, 25kA FP MCCB setted to 50A(Ics=100%Icu) and rotory drive kit including BUC handle and shunt release with auxiliary contact- 1No, Outgoings:- 40 A TP MCCB 25 KA setted to 32A extra current limiting (Ics=100%Icu) - 2 Nos with rotary handle and 32 A two way disconnectable type neutral link suitably connected, 25 A TP MCCB 25 KA setted to 20A(Ics=100%Icu) - 3 Nos with rotary handle and 32 A two way disconnectable type neutral link suitably connected., All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand), Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming is to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. Protection :- ELR with CBCT DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 260KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV withstand for 120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25kA/50 kA . Back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <100 nano sec . Make : Raycap / Erico / Weidmuller, Metering and Indication:- Panel surface mounting 96 Sq.mm,LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF & F with RS485 communication port of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2No,RS 485 to ethernet converter-1 No, SMP power supply- 1 No , 60/5 A Tape wound CT 3 Nos , and 2A SP MCB C Curve (Cat B)-6Nos and a 63A two way disconnectable type neutral link, 22.5mm dia LED type indication lamps for three phases(R,Y &B) - 2 set inside the cubicle. The panel board should have hinged shutters for MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key arrangement and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design.Panel internal earthing should be provided using 25x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required
Providing and laying earth connection earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from on earth electrode including connection with copper thimble excavation and re-filling as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing 4way (4+12) Double door surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, IP 43 , IK 09, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision for MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required .
Fabricating, supplying, erecting and commissioning of wall mounting, fully compartmentalised, dust and vermin proof cubicle emergency panel board of size Incomer: 63 A, 4 Pole, 415 Volts AC : AC23A duty ON LOAD COS with handle-1 No900x2050x250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality ,epoxy paint over two coats of epoxy primer of approved quality, having front openable bolted type vertical bus bar chamber & cable alley covers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top. The panel should have 75x40x6.0mm MS channel provided at the bottom as support and comprising the following(Panel drawing attached with the schedule) Incoming:- 63A, 25kA FP MCCB setted to 32 A and rotory drive kit including BUC handle - 1No, Outgoing:-25A, 25kA TP MCCB setted to 20A with 16A two way neutral link and rotory drive kit including BUC handle -5Nos, All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand), Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators as required. Metering and Indication:- Panel surface mounting 96 Sq.mm,LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF & F with RS485 communication port of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2No,RS 485 to ethernet converter-1 No, SMP power supply- 1 No 3Nos 30/5 A tape wound CTs.,22.5mm dia LED type indication lamps for three phases(R,Y &B) - 2 set and control Group B 2A SP MCB (C Curve)-6 numbers inside the cubicle. The panel board should have hinged shutters for MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key arrangement and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3mm copper strip with two earthing points brought out at bottom side. (Panel drawing attached with the schedule)
Supplying and fixing 4 way , Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts,IP 43 on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 12 Way , Double door, single pole and neutral, sheet steel, MCB distribution board IP 43, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply, conveyance and fixing 32 to 40 A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing four pole, 415 volts, 40A isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, two pole, (single phase and neutral), 240 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole6A MCB
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole10A MCB
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.16A Triple pole MCB
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supply of Fully diffused recessed mounted 2' x 2' luminaire RC380B G2 LED 30S-6500 G4 L60 W60 PSU OD PHILIPS or equivalent having metalic CRCA powder coated housing,colour temperature 6500 K,colour rendering index 80,lumious flux ,electronic in built driver, pf greater than 0.9,THD less than 10%,IEC compliant for safety,performance and EMI.
Supplying Philips or equivalent Master LED tube 600mm 10W 840 T8 l with mounting frame and fixtures etc complete.
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 865 T8 API Philips or equivalent
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
Supplying LED luminaire Philips SM 270 C LED 30S - 6500 PSU WH or equivalent
Supply and fixing 7/9 W LED lamp OSRAM / Philips or equivalent
Supplying modular family street light luminaire Keselec Schreder City or equivalent 40W CW LED,an IP66 LEdSafe® optical compartment,a separate IP66 control gear compartment and extruded aluminium painted housing, a toughened glass protector,permanently sealed with a robotically dispensed silicone sealant,closed at one end by an end cover and the other end by a frame and door assembly (to access control gear) both made of injection moulded polycarbonate,a removable control gear plate,safety plug and socket system,high pressure die cast aluminium painted mounting spigot suitable for horizontal mounting (Ø32-42mm) with tilt flexibility of ± 10 degrees, with lensoFlex2® technology,PMMA lenses with wide photometry for increased pole spacing,System efficacy= >90 lumen/watt, Driver efficiency >= 85%, K 07 impact resistance , driver operating voltage 140 V to 277 V, lifetime residual flux @ Tq 35º @50,0000 hours =70%,Ta = 55º,surge protection of 10Kv ( in differential and common mode),Power factor ≥0.90,colour rendering index≥70 and neutral white light (4,100ºK- 5600ºK).
Supplying Keselec Schreder make Street light luminaire 20W LED, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 90 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K).
Supply and fixing brass batten / angle holder including connection etc as required
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Supply of single phase , 230V ,90W,1400 rpm, 300 mm sweep heavy duty exhaust fan ( Almonard or equivalent) in metal frame Category B ,
Supplying PVC shutters suitable for 305 mm sweep heavy duty exhaust fan
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing metal box of 150 mm X 150 mm X 60 mm deep size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Supplying and fixing extra conduit down rod of 1m length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).40 mm dia with clamps made from 20 x 3 mm MS flat
Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing 50 mm dia nominal bore B class G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Supplying and drawing UTP four pair CAT 6 LAN cable in the existing surface /recess steel/ PVC conduit. One run of cable
Supplying and drawing 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply, installation testing and commissioning wall mounting type dust and vermin proof enclosure 6 U rack system with standard accessories patch panel,cable manager , power strip, cooling fan, cable tray (Model 6U) suitable for installing 24port ethernet switch and patch panel.
Supply, installing, commissioning of manageable switch having Minimum 24 X 10/100/1000 Base-T Ethernet ports, 2 10/100/1000 Base - T Ethernet ports and 2 10000 Base-X SFP Ports (COMBO)• Switching Capacity should be minimum 8.8 Gbps and Minimum 6.55 MPPs Throughput• Switch should support minimum 1000 VLAN's and VLAN ID's,Port-based VLAN and MAC-based VLAN,802.1Q VLAN tagging,Software upgrades,SNM PV2 and SNM Pv3, and MAC limiting. • Switch should be Manageable through CLI, web Interface and SSH.
Supply of Cat 6,1 metre patch cord
Supply of Cat 6,2 metre patch cord
Supply, installing HENSEL telephone junction box K9250 size 200x160x98 mm having 50 pair KRONE type telephone wire connector suitable for 0.50 mm dia copper wire of approved quality mounted on a suitable G.I. frame. All the telephone wires are to be identified and terminated on the block as per the colour code using the special crimping tool as per the instruction of the departmental officer.
Supply of SYNTEL NEOS FULLY DIGITAL ISDN PRI R EPABX WITH TDM/PCM (100% Non-blocking) TECHNOLOGY & IP Platform Configured to support: 4-Trunk lines,24-SLT Extensions Expandable model. Key features:PC/Printer connectivity, Internal Voice prompt 134Nos(Hindi or English), Auto Attendant 8 port,uto fax detection(4 Faxes),ASMDR – 10,000 calls,Call Budgeting/Call Billing,CLI – DTMF,CLI – Restriction,CTI (Computer Telephony Integration),LCR (Least Cost Routing),Name storing,Power on Maintenance,Program/ Master Back up,Time Zone Programming,SMPS With inbuilt battery charger,Customized Music on Hold.
Supply of Lightning Protector for 4 Trunk Lines
Supply of Neo power protection for AC power
Supply Push Button Telephone Preferred make ; Beetel C-11
Supply Push Button Telephone. Preferred makeBeetel C-51 CLI Phone
Supply, installation, testing and commissioning of 3 KVA/2.4kW Online UPS Systems (Numeric Onfiniti , 1PH-1PH,FMI ) Floor Mountable Double conversion Pure Online UPS System( 72VDC or above) with built in Isolation Transformer ,Connecting in Standalone Configuration, Input Voltage 160V-280 VAC and output voltage :230V +/-1% , battery using 12 V C10 rated , 6 nos , 100AH Quanta/Exide make Tubular battery, recommended for 120 minutes backup (Minimum VAH 7200) and suitable Battery Rack for housing the batteries. The UPS should have ISO ,BIS,CE .PeP certification & RoHS marking. Warranty: 3 year onsite for UPS & 4 year for Battery
Supply of 1.5 Tonne,230V,ac,50Hz single phase 5 star rated (2020) full copper highwall split Inverter Air conditioner with cordless remote . Prefered make- Voltas
Supply, Testing and commissioning of Wall hanging type Voltage stabilizer of Single phase 230V, ac, 50Hz ,4000 VA suitable for 170 to 260V input voltage range preferred make of V-GUARD/ MICROTEK for 1.5 T AC
Installation Testing and commissioning of 1 to 1.5 Tonne departmentallly supplied split type air conditioning unit in suitable location
Supplying suitable clamp for outdoor unit
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply and fixing fully automatic water level and pump controller with dual float switch,dry run sensor and starter timer ,voltage 115-270V, Direct Load 1HP, IP40 approved make as per the direction of Deptl officer
Supply of ceiling fans of 1400 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply of LED Industrial Bay luminaire with a system wattage of 100W, electrical Class I, made of AL1070 pure Aluminium, cold forged body sealed with a polycarbonate protector for an optimal luminous flux with IP65 optical and IP67 control gear compartment with direct access to control. The luminaire shall have a system efficacy of 130lm/w, CCT of 5700K and colour rendering index (CRI) ≥70. The Driver (efficiency ≥90%) has internal surge protection of 4/6 kV. Power Factor ≥0.95, a residual flux of ≥70% (L70) @ 50,000 hours. CAT REF: KOMPACT-100W-CW-LED. The Luminaire shall be able to be installed by a hook.
Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp on the truss/ridge of RCC roof upto 8m from ground level
Fabricating supplying and fixing special clamping arrangement for fixing LED bay light and cable junction box to the purlin using 500 mm long 50x6mm ms flat, 12mm dia ms roundbar with U shape open hook fixed vertically to hang the luminaire welded to the 50x6 mm MS flat for fixing the cable junction box . The entire arrangment is to be fixed to the 2 Nos purlin using 2 Nos 250mm long 32 x 6 mm ms flat one end in bended shape to insert with purlin and other end twisted 90 degree to join with the 50x6 mm flat using 6 x 25 mm SS bolt and nut 2 Nos on each. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quality epoxy paint of approved colour as per drawing.
Supply and fixing 80 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
Fabricating, supplying, erecting and commissioning of wall mounting, fully compartmentalised, dust and vermin proof cubicle generator distribution panel board of size 900x1200x250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best qualityepoxy paint over two coats of epoxy primer of approved quality, having , front openable bolted type vertical bus bar chamber & cable alley covers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. (Panel drawing attached with the schedule) Incoming:-63A, 25kA FP MCCB setted to 56 A and rotory drive kit including BUC handle - 1No, Outgoing:-40A TPMCCB setted to 40A extra current limiting , with 32A two way neutral link and rotory drive kit including BUC handle -2Nos, Outgoing:-32A TPMCCB setted to 32A,with 32A two way neutral link and rotory drive kit including BUC handle -1Nos, All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators as required. Metering and Indication:- Panel surface mounting 96 Sq.mm,LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF, Frequency and Energy with RS485 communication port of make SCHNEIDER or equivalent suitable for 415V,50Hz- 1Nos, and 3 Nos 50/5 A class 1 Tape wound CTs,and 3 Nos 2A MCBs and 1 Nos neutral link inside the cubicle. The panel board should have hinged shutters for MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key arrangement and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3mm copper strip with two earthing points brought out at bottom side. (Panel drawing attached with the schedule)
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
Supplying, fabricating , erecting and commissioning DG set Hooter alarm control and indication panel of size 600x300x150mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over a coat of Epoxy Primer, having hinged door covers, 16A motor terminal block 3 Nos, 3 Nos 240V 2pole contactor with 3 Nos NO and 1NC Auxiliary contacts (L&T make MNX 9-2P or equivalent ) ,1 No 230V , 2pole contactor with 1 NO and 1NC Auxiliary contacts , D1 ETM1 MINILEC Multifunction timer (2 x 1 CO contact ) 415V AC,240V AC for repeated operation of Hooter 1No, FP 10A MCB Isolator 1 No, DP 6A MCB Isolator 3 Nos , 4A C curve MCB 3Nos,20Nos 1.5 sq.mm Elmex connector, 4 Nos 230V LED Phase indication lamp ,Phase failure relay with fixed under and overvoltage setting auto reset with 2NO contact minilec S2 VMR2 or equivalent complete wiring using 1.5.SQ.mm PVC insulated copper wire with cablesocket cable tieing etc complete.
Supplying, and commissioning DG set Hooter/ alarm unit usingThermoplastic polycarbonate Cable Junction Boxes IP 65 for outdoor applications 254 X 180 X 111 mm CAPE model No TKPC2818 -11m with Terminals comprising 10Nos 1.5 sq,mm Elmex connector, 6 Nos 230V LED Phase indication lamp , 230V Piezo electric / electronic hooter alarm complete wiring using 1.5.5Q.mm PVC insulated copper wire with cablesocket cable tieing etc complete.
Supplying 12 Core 1.5sqmm 1100 V XLPE insulated armoured copper control cable
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 15652/2006
Supply and providing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/wall bracket fillled with fine sand, painting the frame work/floor stand including making good the damages, colour washing etc.as required.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
Supply and providing single line diagram duly framed,laminated and placed in a conspicuous location for clear vision
Suply and fixing SP Motor Protection Ciircuit Breaker rotary type Suitable for 1H.P pump
Supplying 5 Core 1.5sqmm 1100 V XLPE insulated armoured copper control cable
Supplying RS 485 ,2 Core 0.5sqmm shielded copper flexible cable
Supplying and fixing 6 Way , Double door, single pole and neutral, sheet steel, MCB distribution board IP 43, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_560064.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .