Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 512 CHITTILAKATTU IRIPANAM TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
3 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NITHIN C S
SM (P and P)-CD
Inspection, Repair and Replacement of Prayon Filter Trays and Channels in PA Plant-FACT CD
2025_FACT_886007_1
04098/2025-2026/E32539
Limited
Miscellaneous Works
Item Rate
365 days
AMBALAMEDU
This tender is issued on limited tender basis from the registered bidders of FACT (CD)
4 documents required · 4 mandatory
₹0
₹5,000
Yes
4 Dec 2025
18 Nov 2025
4 Dec 2025
18 Nov 2025
3 Dec 2025
18 Nov 2025
Inspection, Repair and Replacement of Prayon Filter Trays and Channels in PA Plant
Fabrication of Hollow Shafts of Prayon Filter Trays : Collection of required materials and consumables from store.Hollow shafts shall be fabricated out of salvaged 200 NB/ Sch 160 200 NB Pipe/Sch 160 CS pipe and end flange out of 25 mm MS plate.Transport the fabricated shafts and flanges to workshop for machining and collect them back after machining and transport to work site as per instructions from engineer in charge.
Encasing of Prayon Filter Shaft (Filter Hose Side) : Make required arrangements for the work.Remove the existing MS encasing on the HV9 shaft by grinding. Fabricate new encasing out of 6mm MS plate by rolling to required profile. Encase the shaft area with new encasing in two halves. Full weld the encassing on all joint areas. Suit the bearing on the bearing area by proper grinding. Inspect the flange for any repair. Damaged flange areas shall be welded and ground as per instructions.
Repair Works in Spare Filter Trays. Shift and transport the spare filter tray to earmarked area.Clean throughly the spare filter tray. Position the filter tray properly and suitably. Leak test the tray by filling water. All arrangenments for leak testing including fabrication and providing end dummies shall be done by the contractor. Inspect for leaks. Also inspect the trays for any surface cracks.Collect the required materials for repair from store and transport to work site.Repair the leaked and cracked areas by proper grinding the crack/leak area and repair welding with suitable electorode. Suitable pad plate is to be provided as per instructions.The welding area shall be DP tested and inspected by engineer in charge. After the repair welding is successfully completed, leak test the tray again.Once the leak test is successfull drain the water and transport the tray to earmarked storage area as per instructions from engineer in charge, the tray has to be neatly and safetly stacked. The leak test for the trays have to be carried out as many number of times till the test reuslt No Leak obtained. All arangements for leak test will be under contractor's scope.
Replacement of Filter tray End Hollow Shaft (Cell Control Lever Side) : Clean throughly the filter tray. Shift and transport the filter tray to the earmarked area.Assemble the filter tray on the fixture and perfectly. Provide steady pins for firmness.Grind the cladding on the shaft.dismantle/cut the existing end shaft.Prepare the edges with proper grinding.Assemble new shaft,properly align the shaft with the filter tray. Full weld the shaft with the tray using suitable electrode. Properly grind the weld joint and carry out DP test. Any flaw detected will have to be reworked. Provide stiffeners for the weld joint area with the tray as required.After complete welding and grinding provide an encasing of HV9 material covering the weld joint area and on hollow shaft upto the bearing area, and full weld on the encasing using suitable electrode as per instructions from engineer in charge.Once the replacement work is complete, unmount the tray from the fixture and transport the tray to the stacking area as per the instructions from engineer in charge.Clear the site and transport the scrap to area earmarked/scrapyard.
Fabricate Filter Support Channel : Collect the required material from store and transport to work site. Take measurement from exsiting filter support channel,using MS ISMC and MS plate as per the instructions from enginner in charge. All joints shall be full welded. Pad plates shall be provided at required areas/joints and shall be full welded as per instructions from concerned engineer. All welding areas shall be properly ground to facilitate rubber lining. Once the fabrication is complete shift and transport the channels to rubberlining area for rubberlining. After completion of rubberlining transport the support channel to stacking area and safety stack the channles as per instructions.
Replacement of Prayon Filter Support Channel : Transport the spare support chanel to prayon filter site. Collect the required tools/tackles/consumables from store/work shop. After getting process clearence and postioning of filter trays, cut and dimantle the existing support channel. Grind and finish the welding areas on the filter frame. Erect the new support channel to the required position. Properl position the channel and correct the alignment of the channel with the frame.Properly/full weld the joint areas with the channel and filter frame. Take trail run and confirm the position of channel is correct with the position of the tray and there is no entangling of filter tray with the channel. Any rework arising out of this ie, repositioning and re welding of channels etc.shall be done as per instructions from concerned engineer. After successful trial run, clear the site and transport the scrap to area earmarked/scrapyard.
Replacement of Prayon Filter Tray : After getting process clearence dismantle the splash guards, cell control lever, filter hose etc. of the tray to be replaced. Dismantle the CI bearings of the tray. Shift and transport the tray to the repair bay. Repair the tray for the damage/cracks etc. Set new CI bearings on the filter shafts. Ensure the bearings suits the filter shafts (bearings have only design clearence with shaft) under the supervision of concerned engineer. Shift and transport the repaired/spare tray assembly to the site and erect the filter tray to position. Position the CI bearings on the frame and properly tighten the base bolts and cover bolts. Mount the control level assembly, filter hose and splash guards etc. Take trial run and ensure the tray doesnt entangle with other trays/filter support channel. Any rework arising out of this shall be done by the contractor. After successful trial run clear the site and transport the scrap to earmarked area/scrap yard as per instructions.
Fabrication of Filter shoes : Collect the required material from store and transport to work site. Take measurement from exsiting filter shoes fitted on support channels, using MS plate of 12mm & 8mm thick as per the instructions from Enginner in charge. All joints shall be full welded. All welding areas shall be properly ground to facilitate rubber lining. After fabrication completed, transporting the shoes near to support channel stacking area as per instructions.
Supply/unloading and Handing over of 650/1100V, Copper conductor PVC insulated, armoured PVC outer sheathed cable of size 5 cores x 2.5 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope
Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 400 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 185 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 50 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3 cores x 50 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3 cores x 35 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 5 cores x 2.5 sq.mm., copper conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required.
Supply of heat srinkable cable jointing kit for armoured cable of size 3.5 cores x 300 sq.mm.
Supply of heat srinkable cable jointing kit for armoured cable of size 3 cores x 185 sq.mm.
Supply of heat srinkable cable jointing kit for armoured cable of size 3.5 cores x 120 sq.mm.
Supply of cable tags, aluminium or SS for cables (cable No. pre-fix will be given at the time of erection)
Supply and Installtion of UG LT Cable Route Marker as per engineer in charge instructions for cable identification
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3.5 cores x 400 sq.mm. through the existing cable tray at Q10 substation 25 mts / excavated trench 85 Mts and cable tray at phosphorc acid dic wall (35 Mts) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3/3.5 x 50 sq.mm. through the existing and newly fabricated cable tray at various locations in Q10 berth installations of FACT, as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3 x 35 sq.mm. through the newly fabricated cable tray at phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 1 core x 70 sq.mm. (2 Run x 110 Meter) unarmoured, earthing cable through the existing cable tray at Q10 substation 25 mts / excavated trench 85 Mts and cable tray at phosphorc acid dic wall (35 Meters) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 1 core x 35 sq.mm. unarmoured, earthing cable through the newly fabricated cable tray at phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 5 cores x 2.5 sqmm armoured coper cable (4 run x 35 Meter) through the newly fabricated cable tray at phosphorc acid dic wall, as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Rerouting and Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3.5 x 185 sq.mm. through the excisting cable tray at phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays /racks /risers /walls /columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as, cable clamps, bolts, nuts, washers, cable tags, nylon ropes, etc.
Glanding and Termination of cable of size 3.5 core x 400 sq.mm. at PAT MCC Incomer and substation out going with suitable lugs and crimping.
Glanding and Termination of cable of size 3.5 core x 185 sq.mm. at PAT MCC Outgoing with suitable lugs and crimping.
Glanding and Termination of cables of size 3.5 core x 50 sq.mm. at various locations in Q10 berth installations of FACT with suitable lugs and crimping.
Glanding and Termination of cables of size 3 core x 50 sq.mm. at PAT to motor terminal (30 KW Motor, 2 Nos.) with suitable lugs and crimping.
Glanding and Termination of cables of size 3 core x 35 sq.mm. at PAT to motor terminal (15 KW Motor, 2 Nos.) with suitable lugs and crimping.
Termination of earthing cable of size 1 core x 70 sq.mm. at PAT MCC and substation with suitable lugs and crimping.
Termination of earthing cable of size 1 core x 35 sq.mm. at PAT MCC to motor terminals at acid P2O5 pump house with suitable lugs and crimping.
Glanding and Termination of cables of size 5 core x 2.5 sq.mm. at PAT MCC module to motor push button station with suitable lugs and crimping.
Jointing of armoured cable of size 3.5 cores x 300 sq.mm. using heat srinkable cable jointing kit
Jointing of armoured cable of size 3 cores x 185 sq.mm. using heat srinkable cable jointing kit
Jointing of armoured cable of size 3.5 cores x 120 sq.mm. using heat srinkable cable jointing kit
Excavation and back filling of cable trench for laying power/ earthing cables/ cable trench of not less than 300 mm width and 600 mm depth (0.6 meter depth from ground level)
Shifting of existing PAT MCC to temporary shed. The scope of work includes dismandling MCC and all incoming/outgoing cables and shifting to nearest temporary shed./reassembling/fixing the MCC and providing 1 number of incoming cable of size 3.5 cores x 400 sq.mm. and 5 numbers of out going power cables (2 no.s of 3 cores x 50 sq.mm., 2 no.s of 3 cores x 35 sq.mm., 1 no.s of 3.5 cores x 185 sq.mm.) and 4 numbers of control cables (5 cores x 2.5 sq.mm.) in newly fabricated cable tray/trench with suitable single compression gland.
VIKRAMAN NAIR S (BID ID -3326939)
BASHEER V P (BID ID -3327166)
finance_931282.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
Compliance.pdf
Tender Documents • 0.09 MB
BOQ_931282.xls
BOQ • 0.27 MB
SpecialConditions.pdf
Tender Documents • 0.18 MB
Tenderdocuments.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .