Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹26.0 L+₹4.0 L (18.3%)Rejected-AOC | L2 | Rejected-AOC second lowest |
Tender Value
₹20.3 L
EMD Value
₹50,000
Closing Date
10 May 2023, 12:30 pmClosed
Managing Director
KHRWS, General Hospital campus, Red cross Road, Tvpm -695035
Supply, Installation, Testing and Commissioning of 160KVA Diesel Generator set in the ACR LAB, KHRWS Paywards at Govt. Medical Colledge Hospital, Kottayam
2023_KHRWS_572181_1
04/2023-24/KHRWS
Open Tender
Electrical Works
Item Rate
90 days
Kottayam
Registration certificate of KHRWS
7 documents required · 7 mandatory
₹2,500
₹50,000
18 Sept 2023
26 Apr 2023
12 May 2023
26 Apr 2023
10 May 2023
26 Apr 2023
Amount
Generator connection
od326692/2022_2023 : Supply, conveyance, installation, testing and commissioning of 160 KVA DG Set with standard control panel integral with GI Acoustic enclosure and AMF control Panel with MCCB'S and contactors or ATS panel with suitably rated MCCB's for incomers , outgoing and battery charging systems etc on pre fabricated concrete bed as per CPCB norms and as per technical details attached in appendix 1<br>
od326695/2022_2023 : Supply and providing following sizes of B class MS pipe with flanged coupling in each full length of pipe, an additional exhaust piping , fixing the same firmly in the building/ structure using necessary supports such as angle iron MS clamps etc. Painting the pipe and accessories with synthetic enamel paint over a coat of Zinc chromate primer etc as required<br>150mm dia or nearest size B class MS pipe
od326696/2022_2023 : Supply and providing following sizes of B class MS pipe with flanged coupling in each full length of pipe, an additional exhaust piping , fixing the same firmly in the building/ structure using necessary supports such as angle iron MS clamps etc. Painting the pipe and accessories with synthetic enamel paint over a coat of Zinc chromate primer etc as required<br>125mm dia or nearest size B class MS pipe
od347344/2022_2023 : Supply of HSD for full load testing of DG set including conveying and loading
od327034/2022_2023 : Charges for preparing plan, electrical schematic diagram etc for getting approval from Electrical Inspectorate (Actual amount will be re-imbursed on production of documentary evidence
90.12.1.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm
90.12.1.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm
90.12.1.31 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 95 sq mm
90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
90.12.10.6 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation110/94 mm or nearest size
4.1.11 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 62.5 mm depth X 2.0 mm thickness
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
90.14.10.14 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.12 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7 : Supply and providing copper earth bus in the panel board
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.11.14 : MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
od327104/2022_2023 : Painting letters or figures of 2.50 cm, 4cm or 5 cm height with enamel paint as identification mark to SB, DB panel board etc as required
od327110/2022_2023 : Supplying and providing 2mm thick Elastometric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3KV dielectric strength
od323242/2022_2023 : Supply and fixing Red ,Green, blue, yellow, Orange colours LED indicator, AC/DC as required
od323243/2022_2023 : Supply, Installation ,Testing and commissioning of 200/5A, 5VA accuracy class 1, resin cast metering CT
od323244/2022_2023 : Supply and fixing Three phase Digital Ammeter (A - R, Y, B) of accuracy class 0.50
od323245/2022_2023 : Supply and fixing Three phase Digital Voltmeter ( V - RY, YB, BR, R, Y, B) of accuracy class 0.50
90.16.1.5 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)
90.16.1.1 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
od321925/2022_2023 : Supply and providing 25 X 6 mm brass bolt and nut with washers on the existing MS Box/earth bus etc as required including drilling necessary holes as required
od327309/2022_2023 : Supply and providing 25 X 3 mm brass bolt and nut with washers on the existing MS Box/earth bus etc.as required icluding drilling necessary holes as required
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
od321926/2022_2023 : Supply and installation of 4Kg ABC type fire extinguisher with hose and clamps on wall and giving proper training to staff for operating the same
14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
14.8 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
od321930/2022_2023 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift up to 1.5m including getting out the excavated soil and disposal of surplusexcavated soil as directed, within a lead of 50 meters
Supply and renewing the following items in the existing control panel and giving connection as required
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.12 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
od339818/2022_2023 : Red, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia -
od344409/2022_2023 : Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
od339819/2022_2023 : Supply & fixing400/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
od339820/2022_2023 : Supply & fixing Three phase volt meter (V - RY, YB, BR, R, Y, B) of accuracy class 0.50<br>
od339821/2022_2023 : Supply & fixing Three phase ammeter (A - R, Y, B) of accuracy class 0.50
od339847/2022_2023 : Fabrication,supply and instalation of dust and vermin proof , wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, etc. hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit<br>600 x 450 x 250mm
od339848/2022_2023 : Charges for attending petty repairs to the Panel by checking the connection of all the control switches tightening the connections of switches, bus bars, etc and ensure that all the switches are working in good conditions
od340301/2022_2023 : Supply and fixing 250A DIN type fuse base
od343102/2022_2023 : Supply and fixing 250A , 415V 2 way Neutral link
od343103/2022_2023 : Supply and fixing 200A HRC fuse link
od347169/2022_2023 : Supply and fixing 3phase 415V, 100A 4 Pole on load change over switch with sheet steel enclosure on the existing Panel or on wall using suitable angle iron clamps etc as required
Mahesh KR
Bidder Name
Power Care Electrical
Mahesh KR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_846592.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .