Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC As per recommendation of Financial Evaluation Committee | |
| 2 | Rejected-Technical CC64 259 AXIS AZAD ROAD KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | Rejected-Technical As per recommendation of Technical Evaluation Committee |
Tender Value
₹18.9 L
EMD Value
₹28,400
Closing Date
9 Aug 2022, 5:00 pmClosed
REGISTRAR
CUSAT, COCHIN-22
Supply, Installation, Testing and Commissioning of Passenger Lift and allied Electrical Work in Electronics Department at Thrikkakara Campus
2022_CUSAT_498640_1
CUSAT/ET/UEU /4355/22-23
Open Tender
Electrical Works
Item Rate
120 days
Thrikkakara Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,300
Yes
₹28,400
Yes
5 Jan 2023
11 Jul 2022
11 Aug 2022
11 Jul 2022
9 Aug 2022
11 Jul 2022
Amount
PASSENGER LIFT
MSB AND LIFT PANEL
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board A section neoprene beeding suitable for 1.60/2.00 sheet.
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.7 : Supply and providing copper earth bus in the panel board
od63439/2022_2023 : Supply and Installation of 2A SP MCB for controlling the circuit of indication lamps and meters
od63440/2022_2023 : Supplying and fixing Red/ Green/Blue/ Black/ Yellow/ Orange colours LED indicator, AC/DC, 22.5 mm cut out dia (3Nos.).
od63715/2022_2023 : Supplying and Fixing 200 A, TPN, aluminium busbars (25 x 10 mm) in the existing panel board.
od63748/2022_2023 : Supplying and Fixing 63 A, TPN, aluminium busbars (25 x 6 mm) in the existing panel board.
od63716/2022_2023 : Supply and Fixing of 0-200A Ammeter
od63717/2022_2023 : Supply and Fixing of 3Nos. 200/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT.
2.1.3 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.1.4 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
2.1.5 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N
2.1.6 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
od63733/2022_2023 : Providing and fixing following capacity TP&N disconnector inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP&N
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od63734/2022_2023 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100/300mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>40 amps
od63735/2022_2023 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>25 amps
CABLING AND TERMINATION
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 25 sq mm with factory made clamp
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
od63736/2022_2023 : Supplying and providing 60 mm long x 20 mm wide x 1.20 mm thick Copper earthing clips for single compression glands in 25 sqmm to 95 sqmm U. G. cable
EARTHING
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.11 : Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15mm copper conductor (10 SWG)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15mm (10 SWG)
DOCUMENTATION
od63740/2022_2023 : Electrical Inspectorate fees (Amount will be paid against original reciepts)
od63741/2022_2023 : Expenses for preparation and submission of necessary documents, forms, scheme, drawings and certificates etc for getting approval and energization order from EI for Lift and electrical installation. First computer copy A3 sheet and additional copy A3 sheet
Bidder Name
Delstar a Grade Electrical contractors
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .