Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.8 LAccepted-AOC D S ELECTRICALS D S MANDIRAM SREEVARAHAM VALLAKADAVU P O TRIVANDRUM | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
4 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of the Executive Engineer, Electrical Division TVM
GENERAL-Providing Lighting Arrangements in Room No 426 of Assembly Building at Kerala Niyamasabha-For making it as a studio for Sabha TV-General Electrical Work
2022_PWD_533061_5
EDT_ET_36_2022_23
Open Tender
Electrical Works
Item Rate
61 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
16 Mar 2024
25 Mar 2023
10 Apr 2023
25 Mar 2023
4 Apr 2023
25 Mar 2023
Amount
general electrical
OD111376/2022-2023:od58316/2020_2021 :Supply and installation of 100W LED Fresnel Light with COB light source having CRI 96+, TLCI Index 96+, R9 Value 91+ and minimum 50,000 burning hours life. The control to the luminaires shall be through DMX 512 5pin XLR and Manual Mode operation complete with normal yoke, focus defocus etc. The Luminaires shall be powder coated with heat resistant paint in black/grey finish, IP20 Protection, weight of the luminaire shall be min 9.5 kgs. The cost shall be inclusive of barndoor, Safety rope and 2 nos C-Clamp suitable for suspended fixing of the fixtures safely of Aultra ALED 100D F or Equivalent
OD111375/2022-2023:od58318/2020_2021 :Supply and installation of 100W LED panel light fitting with Beam Angle 110 deg having CRI 96+, TLCI Index 96+, R9 Value 91+ and minimum 50,000 burning hours life. Color temperature 5600 deg K Daylight with Input Voltage 100V-260V AC, The control to the luminaires shall be through DMX 512 5pin XLR and Manual Mode operation of The cost shall be inclusive of Diffuser, barndoor, Safety rope and 2 nos C-Clamp suitable for suspended fixing of the fixtures safely of Aultra ALED 100D P or Equivalent
OD111374/2022-2023:Supply and installation of DMX Splitter/ Amplifier unit with 1 DMX input and 8 isolated output suitable for connecting with XLR Cable to luminaires of Aultra DP81 DMX splitter 1 in 8 out or Equivalent
OD111373/2022-2023:Supply and installation of DMX Digital lighting console with 512 DMX Channels including multitoutch screen, 10 mtrs DMX cables with 5-pin XMR connectors of Aultra CX-12, DMX Digital console or Equivalent
OD111372/2022-2023:Supply and installation of 3mtr DMX Cables with 5-Pin XMR Connectors of Aultra or Equivalent
OD118794/2022-2023:Supply installation of 10 mtr DMX cable with 5 pin XMR connections of Aultra or Equivalaent
OD111371/2022-2023:Supply and installation of Studio Lighting Grid consisting of 48-50mm dia, thickness 2mm MS circular tube suitable to install lighting grid with a size of 3ft X 3 ft approximately to cover the entire studio keeping in mind the provision of back lighting. The Load bearing capacity of the lighting grid shall be approximately 200kg per square meter. The lighting grid shall be consist of Rood Grouting to install the fish plates/fasteners and suspenders from fish plates for holding the tubular Lighting grid along with Sockets on the grid IEC/5-15Amps, 16Amps CEE certified of Aultra or Equivalent
OD111370/2022-2023:Supply and installation of 36w (+/-3w) Decorative LED Recess/ suspended mounting 2x2 fitting with UGR <19 Suitable for vertical and horizontal volumetric lighting, customizable centre plate suitable to keep open or give creative zoning, naming etc., 3000 lumens light output, CRCA Body and Polycarbonate diffuser including suspension kit, 50,000 burning hours as per L70 of Philips RC740B LED30S/865 W60L60 PSU WH
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.7:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 1.5 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Bidder Name
D SURESH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_840131.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .