Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAdmitted-Finance | ₹2.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.9 Cr+₹13.7 L (4.90%)Admitted-Finance | ₹2.9 Cr+₹13.7 L (4.90%) | L2 | Admitted-Finance |
| 3 | L3₹3.3 Cr+₹47.9 L (17.1%)Admitted-Finance | ₹3.3 Cr+₹47.9 L (17.1%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical 14 474A 14 474B 14 474C 14 474D BROTHERS ARCADE AMBALAMEDU P O OPP SNDP MANDIR KUZHIKKADU ERNAKULAM KERALA 682303 | ERNAKULAM | KERALA | 682303 | - | - | Rejected-Technical The party failed to provide documents, in line with PQ criteria. |
| 5 | Rejected-Technical | - | - | Rejected-Technical The party failed to provide documents, in line with PQ criteria. |
| Sl No | Description | Qty | Unit | MBM ENGG WORKS L2 | PNP CONSTRUCTIONS L1 | SB CONSTRUCTION AND TRAVELS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish and cleared items to locations pointed out by Engineer in-charge, with in premises of FACT-WI. | 200 | M2 | 5 ₹1,000 Lowest | 10 ₹2,000 | 100 ₹20,000 |
| 2.00 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, with in premises of FACT-WI at locations pointed out by Engineer in-charge in all kinds of soil | 200 | M2 | 30 ₹6,000 Lowest | 50 ₹10,000 | 40 ₹8,000 |
| 3.00 | Demolishing plain cement concrete of any grade manually/ by mechanical means from all heights and depths including disposal of material within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 5 | M3 | 950 ₹4,750 Lowest | 2,000 ₹10,000 | 2,000 ₹10,000 |
| 4.00 | Demolishing reinforced cement concrete of any grade manually/ by mechanical means from all heights and depths including disposal of material including cutting of reinforcement steel as required within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 50 | M3 | 2,100 ₹1,05,000 Lowest | 4,000 ₹2,00,000 | 4,000 ₹2,00,000 |
| 5.00 | Demolishing brick work in cement mortar manually / by mechanical means from all heights and depths including stacking of serviceable material and disposal of unserviceable material within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 70 | M3 | 1,100 ₹77,000 | 1,000 ₹70,000 Lowest | 1,000 ₹70,000 Lowest |
| 6.00 | Demolishing stone rubble masonry in cement mortar manually/ by mechanical means from all heights and depths including stacking of serviceable material and disposal of unserviceable material within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 20 | M3 | 1,100 ₹22,000 | 500 ₹10,000 Lowest | 1,000 ₹20,000 |
| 7.00 | Dismantling doors, windows, ventilators (steel / wood / aluminium / PVC / FRP) frames and shutters including chowkhats, architrave, holdfasts etc. complete and stacking within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 30 | M2 | 1,600 ₹48,000 | 100 ₹3,000 Lowest | 1,000 ₹30,000 |
| 8.00 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. from all heights including dismembering and stacking within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 200 | KG | 15 ₹3,000 | 12 ₹2,400 | 10 ₹2,000 Lowest |
| 9.00 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 30 | M2 | 200 ₹6,000 | 100 ₹3,000 Lowest | 100 ₹3,000 Lowest |
| 10.00 | Dismantling existing electrical works in the building being demolished and reconnecting electrical connections and rerouting the same as required and stacking dismantled items within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge. | 1 | LS | 1,20,000 ₹1,20,000 | 20,000 ₹20,000 Lowest | 50,000 ₹50,000 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
25 Aug 2023, 11:00 amClosed
AGM(MAT)-C
CORPORATE MATERIALS PD ADMINISTRATION BUILDING FACT UDYOGAMANDAL KERALA
Construction of New PA Pump House cum Office Building at FACT Q10 Berth, Willingdon Island, Kochi
2023_FACT_764162_1
04046/2023-2024/E27905
Open Tender
Miscellaneous Works
Item Rate
450 days
Willingdon Island
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1 L
Yes
FACT Q10 BERTH
3 Nov 2023
28 Jul 2023
25 Aug 2023
28 Jul 2023
25 Aug 2023
28 Jul 2023
9 Aug 2023
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish and cleared items to locations pointed out by Engineer in-charge, with in premises of FACT-WI.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, with in premises of FACT-WI at locations pointed out by Engineer in-charge in all kinds of soil
Demolishing plain cement concrete of any grade manually/ by mechanical means from all heights and depths including disposal of material within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Demolishing reinforced cement concrete of any grade manually/ by mechanical means from all heights and depths including disposal of material including cutting of reinforcement steel as required within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Demolishing brick work in cement mortar manually / by mechanical means from all heights and depths including stacking of serviceable material and disposal of unserviceable material within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Demolishing stone rubble masonry in cement mortar manually/ by mechanical means from all heights and depths including stacking of serviceable material and disposal of unserviceable material within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Dismantling doors, windows, ventilators (steel / wood / aluminium / PVC / FRP) frames and shutters including chowkhats, architrave, holdfasts etc. complete and stacking within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. from all heights including dismembering and stacking within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Dismantling existing electrical works in the building being demolished and reconnecting electrical connections and rerouting the same as required and stacking dismantled items within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Dismantling plumbing and sanitary lines and fixtures including water tanks, capping lines as required or rerouting as necessary, and stacking dismantled items within premises of FACT-WI at locations pointed out as per direction of Engineer in - charge.
Disposal of moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved dumping grounds or to FACT CD for lead up to 30km for all lifts, complete as per directions of EiC. Note - Item to be applicable in urban areas having directions for restricted hours for movement / plying of load carrying motor vehicle of 3.5cum or more.
Supplying and stacking good earth brought from outside, at locations pointed out by the engineer in-charge. The rate includes all charges including royalties, loading – unloading, transportation, cost of earth, labour, other charges etc. complete.
Earth work in excavation in open areas (exceeding 1.5m in width as well as 10sqm on plan) by mechanical means (Hydraulic excavator) / manual means in all kinds of soil, for lifts up to 1.5m from existing ground level, including getting out the excavated soil and disposal within the premises of FACT-WI as directed by the Engineer in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches in all kinds of soil, including dressing of sides and ramming of bottoms, lifts up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil up to a lead of 50m, as directed by the Engineer in-charge within the premises of FACT-WI. The rates shall include bailing out water, and keeping the sides from collapsing using necessary timbering, planking, and shoring.
Filling available good earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, for lead up to 50m and lift up to 1.5m.
Supplying, diluting, and injecting the ground with Chlorpyriphos/Lindane E.C. 20% with 1% concentration at 1 litre per holes of 300mm depth dug 1m apart at both directions, covering the area under construction.
Casting 600mm diameter bored cast in-situ reinforced cement concrete piles in M35 grade concrete after boring by Direct mud circulation method as per IS 2911- Part 1/sec 2, having minimum cement content of 400 kg/cum of concrete, using Portland Pozzolana cement conforming to IS 1489, river sand / manufactured sand conforming to IS 383, 20mm or less size graded hard granite broken stones, admixtures to concrete as per IS 9103, water as per IS 456 and reinforced with High strength deformed bars of 500D / 550D grade conforming to IS 1786 for the entire length of piles. All the materials used in the casting of concrete shall be done with the approval of Engineer in-charge. The rate shall include the cost for all plants, tools, materials, labour and other services for boring the piles including mobilisation and de-mobilisation of piling rigs, boring to the required depth and stabilisation of hole with bentonite slurry or other required material to suit site conditions, making channels in the ground, making service roads and arrangements for transportation and disposal of muck (The muck will be treated as owned by the contractor and it will be the responsibility of the contractor to dispose the muck without causing environment damage with necessary permission from the concerned authority and consultant / client to be informed well in advance on the disposal methodology before starting the work), cleaning the bores with water, lowering the reinforcement cages, concreting, excavating and levelling the ground exposing piles to a depth of 150mm below cut-off level after curing and gaining sufficient strength. Rate of reinforcement and excavation for pile cap shall be paid extra - For piles up to length of 60m below cut-off level. (Payment shall be made for length of pile below cut off level only).
Charges for empty boring through various strata to the required diameter of pile specified in the Item above, clearing the area, collecting, conveying and disposal of muck of all types such as liquid, fluid, solid and spoil earth (The muck will be treated as owned by the contractor and it will be the responsibility of the contractor to dispose the muck without causing environment damage with necessary permission from the concerned authority and consultant / client to be informed well in advance on the disposal methodology before starting the work) including hire charges for tools and plants, rigs, cost of labour, etc. complete for all depth. (Payment will be made for abandoned pile due to reasons attributable to owner and for empty boring involved in between ground level at the time of casting the piles and cut-off level of piles.) 600 mm dia. piles.
Chipping and removing weak concrete at the top of RCC piles to the cut off level in line and levels carefully, manually / mechanically without damaging the remaining portion of pile and exposing the reinforcement, cleaning the reinforcement off any loose concrete particles, and removing the debris to places pointed out within the project premises as directed by the Engineer in-charge.
Carrying out routine vertical load testing of piles having a safe load up to 1200kN in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Testing agency shall submit the design of loading platform for the approval of Engineer in-charge. Test Load shall be 1.5 times the Safe capacity of pile. Dynamic method of testing is not permitted.
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results certified by a Geo-technical expert, all complete as per direction of Engineer in-charge.
Providing hard core layer of required thickness using 40mm nominal size graded hard granite broken stones after compacting the underlying soil, spreading and levelling the stones and then spreading a layer of 6mm downgraded crushed aggregates on top of the broken metal layer and it shall be watered in order to force the crushed fine aggregates into the void spaces of the broken stone and repeat the process till all the voids are filled with crushed fine aggregates right up to the edges of hard core layer, including cost of all materials and labour charges etc, complete.
Providing and laying plain cement concrete work in 1:4:8 mix (1 cement: 4 coarse river sand/manufactured sand: 8 40mm nominal size graded hard granite broken stones) including all charges for mixing concrete, laying, consolidating, curing, cost for bailing out of water, oil, liquid mud etc. from all sources in excavated pits, trenches, etc. complete at all levels as per standard specifications but excluding the cost of shuttering, and as directed by the Engineer in-charge for foundation / levelling course etc.
Providing and laying plain cement concrete work in 1:1.5:3 mix (1 cement: 1.5 coarse river sand/manufactured sand: 3 20mm nominal size graded hard granite broken stones) including all charges for mixing concrete, laying, consolidating, curing, cost for bailing out of water, oil, liquid mud etc. from all sources in excavated pits, trenches, etc. complete at all levels as per standard specifications but excluding the cost of shuttering, and as directed by the Engineer in-charge for foundation / levelling course / drains / yards / trenches etc.
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in-charge. (Note: - Cement content considered in this item is @ 350 kg/cum. Excess cement used as per design mix is payable separately) – for all works below plinth level.
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in-charge. (Note: - Cement content considered in this item is @ 350 kg/cum. Excess cement used as per design mix is payable separately) – for all works above plinth level.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for foundation footings, bases of columns and walls and for mass concrete with straight sides.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for Suspended floors, roofs, landings, balconies and access platform, weather shades, chajja etc. including side shuttering. Rate to include for shuttering at all heights.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for Lintels, beams, plinth beams, girders, bressumers and cantilevers. Rate to include for shuttering at all heights.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion /curing at all levels for Columns, Pillars, Piers, Abutments, Posts and Struts. Rate to include for shuttering at all heights.
Providing form work to cement concrete and RCC works with necessary plywood / steel sheet, steel joists, runners, struts, posts etc with adjustable spans and telescopic posts, wooden planks etc. including removal after completion / curing at all levels for Stairs, (excluding landings) except spiral-staircases. Rate to include for shuttering at all heights.
Supplying, fabricating, conveying, and fixing reinforcement to RCC works at all levels with high strength deformed bars of Fe500D / Fe550D grade Thermo Mechanically Treated (TMT) bars conforming to IS 1786 including all charges for uncoiling and straightening rods, cutting rods, bending cold, placing in position, and supplying & tying with black annealed tying wire of 16 gauge, etc. complete.
Providing and laying factory made precast and well cured cement solid blocks conforming to IS 2185 (Part 1) of 100/150/200 mm thickness, having a compressive strength of 5N/mm2 from approved manufacturer in foundation and plinth in cement mortar 1:6.
Providing and laying autoclaved aerated cement blocks masonry with 100 / 150mm/200mm / 230mm / 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar in ratio as specified by the manufacturer, all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
Providing and laying half brick masonry with common burnt modular clay bricks of class designation 5.0 conforming to IS 1077, having a standard size of 190x90x90mm with or without frog, quality conforming to IS 3495 for use in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 (1 cement: 4 coarse sand).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III): 6 graded stone aggregate 20 mm nominal size) over 75mm thick hardcore, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, The rate includes cost of hardcore.
Plastering with cement mortar 1:4, 15mm thick one coat floated hard and trowelled smooth over brick / RCC, for works of all heights up to 15m above ground level, including all scaffolding works as required.
Plastering with cement mortar 1:3, minimum 6mm thick one coat floated hard and trowelled smooth, for plastering over / under RCC beams, slabs, sunshades etc., for works of all heights up to 15m above ground level, including all scaffolding works as required.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litres / 10sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and thoroughly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer in-charge.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Applying one coat of exterior grade water thinnable cement primer of approved brand and manufacture on wall / RCC surface.
Providing and applying white cement-based putty of average 2mm thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls / roofs with smooth weatherproof quality acrylic exterior emulsion paint of required shade for new work with two or more coats applied @ 1.67 ltr/10 sqm over exterior primer already applied (ASIAN APEX ULTIMA / BERGER WEATHERCOAT LONGLIFE or equivalents of other approved brands)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, with two or more coats as per the manufacturers specifications to achieve even shade and colour (ASIAN APCOLITE SHYNE / BERGER EASYCLEAN / NEROLAC BEAUTY SHEEN or equivalents of other approved brands).
Providing and laying fully vitrified polished floor tiles of approved brand, colour and design and finish (matte / glossy) of size 1200x1200mm or 1200x800mm size having minimum thickness of 10mm, with water absorption less than 0.08% and conforming to IS: 15622 laid over a bed of 20-40mm thick dry cement mortar 1:4 (1 Cement :4 Coarse sand) with 3mm wide spacers and fixed with cement slurry and grouting the joints of flooring tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting / cleaning and finishing complete as per direction of Engineer in-charge.
Providing and laying rectified ceramic floor tiles of approved brand, colour and design and finish (matte / glossy) of size 600x600mm or 800x800mm size having minimum thickness of 8mm, with water absorption less than 0.08% and conforming to IS: 15622 laid over a bed of 20-40mm thick dry cement mortar 1:4 (1 Cement :4 Coarse sand) with 3mm wide spacers and fixed with cement slurry and grouting the joints of flooring tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting / cleaning and finishing complete as per direction of Engineer in-charge.
Providing and fixing ceramic glazed wall tiles of size 300x450 or higher size, conforming to IS:15622 with a minimum thickness of 6mm, of approved make, in all colours and shades as approved by Engineer in-charge, in walls, skirting, risers of steps and dados, fixed with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 in average 3 mm thickness laid with or without spacers, on roughened plastered surfaces and grouting the joints of tiles using epoxy grout of desired shade, including filling / grouting and finishing complete as per direction of Engineer in-charge.
Providing and laying full body vitrified antiskid stair tread tiles with self-embossed grooves / patterns and bull nose finish and having minimum 12mm thickness, with water absorption less than 0.08% and conforming to IS: 15622 laid over a bed of 20-40mm thick dry cement mortar 1:4 (1 Cement :4 Coarse sand) and fixed with cement slurry and grouting the joints of flooring tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting / cleaning and finishing complete as per direction of Engineer in-charge.
Providing and fixing 10mm thick fully vitrified stain resistant, mirror polished ceramic tiles for kitchen countertops, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including cutting holes for sinks or handrails, rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Finishing concrete surface to polished finish (matte finish) by grinding, application of stains, densifier (lithium salts), honing, polishing etc as per the guidelines of the manufacturer and directions of Engineer in-charge.
Providing and laying acid proof tiles after cleaning the cement finished surface well with water and allowing to dry, brushing and removing all dust, apply two coats of approved quality bitumen based primer conforming to IS. 1580 as per manufacture's specification, applying 12 mm thick asphalt membrane with hot melt asphalt free from filler conforming to IS. 1580, then laying acid resistant tiles of class II quality conforming to IS. 4860 over a bed of 6 mm thick potassium based silicate cement mortar conforming to IS. 4832 - part. I & 4441 and joints 5 mm thick, raking the joints to full depth from the top surface, removing the raked-out mortar and filling the entire depth of joints with Furan base resin cement mortar conforming to IS. 4832 - part. II including acid washing curing etc. complete as per relevant IS. 4443 specifications at all heights. with 230x112x38 mm or nearest size tile.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing polyester powder coated aluminium work in frame and shutters for doors, windows, ventilators, and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions with silicone sealants to prevent water ingress i.e., at top, bottom, and sides. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, made tight with EPDM rubber / neoprene gaskets and, C.P. brass / stainless steel screws, hinges for shutters and all other necessary fixtures, including aluminium handles and bolts all complete as per architectural drawings and the directions of Engineer in-charge. (Glazing / panelling to be paid for separately). Powder coating shall be of ivory white colour with a minimum thickness of 50 micron.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer in-charge with 4mm float glass.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer in-charge with 8mm float glass.
Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sides, flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer in-charge.
Providing and fixing false ceiling with 12.5 mm thick tapered edge moisture resistant gypsum plain board conforming to IS: 2095- (Part I) having BIS certification marks, at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Supplying, conveying, fabrication and erection of mild steel single section members such as channels, angles, tubes, pipes, beams, rods, plates, flats etc. with fixtures such as end stops, clamps, bolts and nuts etc. including charges for cutting, splicing, drilling holes as required, fixing to lines and levels and cleaning and painting as per technical specifications given in specific requirements of work.
Supplying and fixing in position mild steel foundation anchor bolts conforming to IS 5624 and 2062 with or without using templates made of marine ply, as per the drawings issued including supplying the matching washers and nuts conforming to IS 1363 and 1367, and tightening the nuts, as per the direction of engineer in-charge.
Supplying and fixing non-asbestos cement corrugated roofing sheets of minimum 6mm thickness reinforced by organic fibres and/or inorganic synthetic fibres (as per IS: 14871) for roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self-drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.
Supplying and fixing ‘clear’ Polycarbonate sheet of thickness not less than 2mm and width not less than 1000mm, having a transparency not less than 85%, and profile matching with the supplied 6mm thick corrugated high impact polypropylene sheet, and fixed with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self-drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters, and trusses), including cutting sheets to size and shape wherever required. The pitch and height shall be suitable for overlap with the roofing sheets being laid, so that the overlap shall be watertight and secure.
Supplying and fixing non-asbestos cement roof fixtures like hips, valleys and flashings of minimum 6mm thickness reinforced by organic fibres and/or inorganic synthetic fibres (as per IS: 14871) for roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self-drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting to size and shape wherever required.
Supplying and fixing in position half round rain-water gutters made from UPVC pipe conforming to IS 13592 Type A, including connecting them to down water pipes with suitable joint sealants. The sections shall include necessary end pieces and down take pieces.
Providing and fixing on walls / RCC column face un-plasticised Rigid PVC single socketed pipes of 110 mm diameter(nominal) rainwater pipes conforming to IS: 13592 Type A, using SS clamps and nails and attaching one end to rain-water gutters with proper sealants, including necessary bends for taking water from roof gutter to building drain in ground.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in RCC slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board of size 510x1040 mm bowl depth 250 mm as per IS:13983 fixed countersunk supported on counter slab, with all fixtures like waste coupling etc. including cutting and making good the walls and slabs wherever required.
Providing and fixing floor mounted, white vitreous china single piece water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc. including making connection with the P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing floor mounted, white vitreous china single piece water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc. including making connection with the P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing 15 mm nominal bore CP bib cock - short body (quarter turn) of approved make and quality with cover plates for fixing into plumbing line already laid in the wall.
Providing and fixing 15 mm nominal bore CP swivel cock swan neck (quarter turn) of approved make and quality having length with cover plates for fixing into plumbing line already laid in the wall.
Providing and fixing CP soap dish holder of approved make and quality having length not less than 150mm and breadth not less than 60mm with fitting arrangements like screws and wall plugs for fixing on the toilet wall.
Providing and fixing 600mm long CP towel rail of approved make and quality with brackets fixed to toilet walls with CP brass screws and rawl plugs with sufficient length and size to hold the brackets firmly to the wall.
Providing and fixing cloth hook of stainless steel of approved make, having length not less than 300mm having six hooks, fixed to wall with rawl plug and stainless-steel screws as per the direction of engineer in-charge.
Providing and fixing CP health faucet with hose and holder of approved make and having hose length not less than 1000mm with fitting arrangements like screws and wall plugs for fixing on the toilet wall.
Providing and fixing 15mm nominal bore CP angle cock of approved quality and make with fitting arrangements like wall cover plates screws and wall plugs for fixing on the wall.
Providing and fixing 15mm nominal bore PTMT angle cock of approved quality and make with fitting arrangements like wall cover plates screws and wall plugs for fixing on the wall.
Providing and fixing mirror of superior glass (of approved quality) and of rectangular shape and size 600x450 or nearest higher size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing to be hung on walls.
Providing and fixing PVC Floor multi-trap with 50mm waste outlet for draining wastewater from toilet, with CP cover, fixed in alignment with the floor tile and sides sealed for proper drainage of water, as per directions of Engineer in-charge.
Providing and fixing PVC Floor drains with 40mm/50mm waste outlet for draining wastewater from toilet, with CP cover, fixed in alignment with the floor tile and sides sealed for proper drainage of water, as per directions of Engineer in-charge.
Providing and fixing 15 mm nominal bore PTMT bib cock - short body (half turn) of approved make and quality having length not less than 115mm with PTMT cover plates for fixing into plumbing line already laid in the wall.
Providing and fixing CPVC ball valve of 25mm nominal bore to CPVC pipes in external exposed works.
Providing and fixing CPVC ball valve of 20mm nominal bore to CPVC pipes in external exposed works.
Providing and fixing PTMT float valve of approved quality, colour and make complete with fittings - Epoxy coated aluminium rod of length not less than 250mm threaded at both ends, with nuts and rubber washers and PVC ball.
Providing and fixing 25 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply including all CPVC plain & brass threaded fittings and fixing the pipe on walls with clamps at 1m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of Engineer in-charge.
Providing and fixing 20mm nominal outer diameter Chlorinated Polyvinyl Chloride (CPVC) pipes, in concealed work having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in-charge.
Providing and fixing soil, waste and vent pipes (Type B, pasting type conforming to IS 13592) of 110mm dia, for removal of waste including all fixtures like bends, elbows, etc. as required including cutting walls and excavating trenches and jointing pipes and fittings with PVC solvent cements and making good the same and testing of joints complete as per the directions of Engineer in-charge.
Providing and fixing soil, waste and vent pipes (Type B, pasting type, conforming to IS 13592) of 50mm dia, for removal of waste including all fixtures like bends, elbows, etc. as required including cutting walls and excavating trenches and jointing pipes and fittings with PVC solvent cements and making good the same and testing of joints complete as per the directions of Engineer in-charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank having 3-layer wall thickness, ISI marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet, and overflow pipes but without fittings and the base support for tank. (White colour).
Supply and installation of prefabricated ferrocement septic tank with soak pit from approved manufacturers including excavation, placing tank in position, plumbing works, backfilling, and levelling the ground, placing manhole covers and vent pipes etc. complete including all materials and labour, to meet a user capacity of 15 users. The scheme shall be with the approval of Engineer in-charge.
Construction of gully trap with SWR P-type pipe fittings (pasting type) housed in brick masonry chamber constructed with common burnt clay non-modular bricks of class 5.0 on 1:1.5:3, grade concrete slab, both sides plastered with CM 1:4 , and covered with watertight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per approved design, all works complete including supply of all materials and labour.
Conference table- Fabrication and installation of modular multi part conference table of with 10 nos 1500mmx600mm plan size table units and two numbers 900mmx900mm plan size table units made with 19 mm BWP grade plywood pasted with 1mm laminate (Merino, Green or equivalent approved brand) as per design. Edges shall be finished with edge band pasted with edge banding machine. Top of the table shall be provided with pop up module arrangements for fixing plug boxes and provisions for USB, HDMI, Projector, Mic/sound system etc. All laminates to be hot pressed on BWP grade ply including cost of all materials and labour. The individual modular units shall be joined (interlocked)to each other with 3mm thick galvanised and painted MS plates. The contractor shall submit the detailed design for approval and obtain the same before fabrication. The rate shall be for the total area of BWP ply used.
Supplying and fixing writing board of size 2400mm x 1200mm made of BWP grade plywood and pasted with glossy white laminate, edges finished with edge band pasted with edge banding machine, fixed to wall with SS screws at location pointed out by Engineer in-charge.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with required machinery in sub- base / base course on well-prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying 50-100mm thick (compacted) bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder - VG 30 @3.5% of total weight, laid over WMM to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying 25mm thick (compacted) semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate), laying to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
Supply and erection of 415V, 63A, 3 Ph & N, 8WAY Lighting Distribution Board with one number 63A, 4 pole RCBO (30mA) as incomer and 12 Nos 10A, 3 Nos 16A and 9Nos 20A Single Pole MCBs as outgoing feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. Cable adaptor box also shall be provided for incoming and outgoing cable/ wires (All MCBs shall be of C curve and 10 kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum). The scope shall also include the cost of termination of incoming wires including supply of lugs. The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for flush mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked. Make of DB shall be LEGRAND/ HAVELLS/ INDOASIAN/ STANDARD ELECTRICALS/ C&S.
Supply and erection of 415V, 63A, 3Ph&N, 6WAY Lighting Distribution Board with one number 63A, 4pole RCBO (30mA) as incomer and 9 Nos-10A, 2Nos-16A & 7Nos-20A Single Pole MCBs as outgoing feeders. The DB shall have separate buses for phases, neutral and earth. The DB shall be double door type and suitable for conduit entry for outgoing and cable entry for incoming. Cable adaptor box also shall be provided for incoming and outgoing cable/ wires (All MCBs shall be of C curve and 10kA short circuit capacity. DBs shall conform to IS 13032 and Bus bar rating shall be 100A minimum). The scope shall also include the cost of termination of incoming wires including supply of lugs. The earth bus shall be suitable for taking individual earth leads for each circuit. The DB shall be suitable for flush mounting on a wall unless otherwise indicated in the layout drawing. The enclosure shall have IP43 protection. The gaskets used if any, shall be of neoprene only. Spare slots provided for MCB mounting if any shall be properly blanked. Make of DB shall be LEGRAND/ HAVELLS/ INDOASIAN/ STANDARD ELECTRICALS/ C&S.
Supply and erection of concealed conduit wiring for light point/ exhaust fan with 1.5Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in 3x3 PVC Box with UPVC cover in wall, 1No 6A modular switch (LEGRAND 6755 01 or equivalent) modular plate in suitable type box concealed in wall and earthing with 1.5Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document. Also refer sl no. 2.0 of Annexure for further requirement.
Supply and wiring for group controlled light points (from one light point to another light point), similar to wiring for single point wiring but without control switch. Wiring from control switch to first light point is covered another item. Refer Annexure for further requirement.
Supply and wiring light points similar to wiring for single point wiring in such a way that light can be controlled from two points independently by using 2-way switch (Legrand 6755 02 or equivalent). Refer Electrical layout drawings attached with this document.
Supply and Wiring for ceiling fan point with 1.5 Sq.mm FRLSH PVC insulated stranded single core copper conductor cable through 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark clamped in wall, ceiling or column including supply and fixing of 3Plate ceiling rose in junction box concealed in ceiling, 1No 6A modular switch (LEGRAND 675501 or equivalent) modular plate with regulator (Legrand 675530 or equivalent) in suitable type box concealed in wall and earthing with 1.5 Sq.mm insulated copper conductor etc. including supply of all fixing materials and accessories and interconnections complete as required. Refer Electrical layout drawings attached with this document. Also refer sl no. 2.0 of Annexure for further requirement.
Supply and wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable, through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark concealed in wall, ceilingor column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. Refer sl no. 2.0 of Annexure. 2 runs 4sq.mm FRLSH PVC+ 4Sq.mm FRLSH PVC Copper conductor as earth wire.
Supply and wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLSH PVC insulated stranded single core copper conductor cable, through 20mm/32mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark concealed in wall, ceiling or column or floor including supply of all fixing materials and interconnections complete as required for circuit wiring from the distribution board to first switch board. Refer sl no. 2.0 of Annexure. 2 runs 2.5 sq.mm FRLSH PVC+ 2.5Sq.mm FRLSH PVC Copper conductor as earth wire.
Supply and fixing of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and 5/6 amps modular switch (LEGRAND 6755 01 or equivalent), with modular front plate and cover in suitable box concealed in wall with all fixing materials and interconnections as required.
Supply and fixing of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and 5/6 amps modular switch (LEGRAND 6755 01 or equivalent), with modular front plate and cover in GI box suitable for modular switches concealed in wall with all fixing materials and interconnections as required. 5A Plug socket outlet for the fan shall be provided at a height of 2.0m from the floor level. The control switch shall be provided at a height of 1.5m from the floor level. (For fixing Wall mount fans)
Supply and fixing of 3pin 15/16 amps modular socket (LEGRAND 6755 55 or equivalent) outlet and 15/16amps modular switch with indicator (LEGRAND 6755 13 or equivalent), with modular front plate and cover in box suitable for modular switches concealed in wall with all fixing materials and interconnections complete as required.
Supply and fixing 20A DP modular switch with indicator (LEGRAND 6730 13 or equivalent) and Modular socket (LEGRAND 6730 47 or equivalent), modular front plate and cover in GI box suitable for modular switches concealed in wall including all fixing materials and interconnection complete as required. The switch and socket shall be installed at a height of 1.2 metre and 2.4 metre respectively from floor level. For the A/C units suitable openings shall be made in co-ordination with Civil contractor for taking the tubing to outdoor units. 2.5inch dia PVC pipes shall be used for providing openings and these openings shall be properly sealed after erection of A/C set. At points where A/C sets are not envisaged now, 2.5-inch PVC pipes shall be closed using suitable end caps.
Supply and fixing of modular type, RJ 11 Telephone socket (LEGRAND 6755 41 or equivalent), with non-metallic front plate including suitable size box concealed in wall with all necessary accessories and interconnections complete as required.
Supply and fixing of three Nos of 3 pin 5/6 amps modular socket (LEGRAND 6755 50 or equivalent) outlet and three nos of 5/6 amps modular switch (LEGRAND 6755 01 or equivalent), with modular front plate and cover in suitable box concealed in wall with all fixing materials and interconnections as required. (Computer Points)
Supply and erection of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 4sq.mm. Refer sl no. 3.0 of Annexure for requirement.
Supply and erection of 650/1100V, copper conductor XLPE insulated, extruded PVC sheathed, armoured, PVC outer sheathed cable of size 3C x 2.5 sq.mm. Refer sl no. 3.0 of Annexure for requirement.
Supply and installation of 2 PAIR Telephone cables with concealed conduit system of wiring, with annealed high conductivity copper conductor 0.5mm dia, polyethylene insulated, cores twisted into pairs, bunched together, laid up, cores taped with absorbent tape, polyethylene sheathed, overall polyethylene jacketed unarmoured cable conforming to TTE/ITD specific ation. Erection scope shall include all accessories including erection of 20mm dia 1.5mm thick Electrical grade PVC conduit with ISI mark.
Supply, installation, testing, commissioning and handing over of shock proof, rust proof, dust proof, waterproof, corrosion proof junction boxes in Thermoplastic Polystyrene enclosure, having internally embedded gasket and suitable dust caps to seal the mounting slots with plane wall surface for different cables. cable glands / bushes of suitable sizes and all other required hard wares shall be included in scope of supply. The junction boxes supplied shall be Hensel make or equivalent as certified by FEDO Engineer in Charge. Mounting of junction boxes shall be on wall / pedestals etc. as required at a height of 1.5m from floor as per the drawing. The scope shall include supply of fixing hardware required for the same. All spare entries of the junction boxes shall be suitably blanked. Fixing bolts / nuts/ screws shall be stainless steel. The scope includes drilling suitable holes for cable entry. Junction boxes with Krone type connectors suitable for terminating 1 No. 10 Pair, 0.5mm dia unarmoured cable as incomer and 8Nos 2Pair 0.5 mm dia unarmoured cable as outgoing.
Supply and erection of 19W LED WEATHERPROOF type tube light fixed on industrial type batten suitable for surface mounting prewired upto terminal block with all accessories such as drivers lamp holders, lamp etc. with transparent PC cover and all related accessories like rods for suspension, wires etc. (PHILIPS TCW450 P 1XTLED 19W P3397 or equivalent type of CROMPTON GREAVES/ PHILIPS /GE LIGHTING LTD / WIPRO/ HAVELLS/ BAJAJ. Refer sl no. 4.0 of Annexure.
Supply and erection of 20W LED batten suitable for surface mounting prewired up to terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (PHILIPS BN021C LED20S PSU CW GR S2 or equivalent type of CROMPTON GREAVES/ PHILIPS /GE / WIPRO/ HAVELLS/ BAJAJ).
Supply and erection of 110W LED Floodlight made up of pressure die cast aluminium housing with toughened glass and high-power LEDs and secondary lenses with IP66 protection suitable for fixing in terrace area with all related accessories for fixing the luminaire (PHILIPS BVP192 LED110 CW HO NB FG GR PSU or equivalent type of CROMPTON GREAVES/ PHILIPS /GE / WIPRO/ HAVELLS/OSRAM).
Supply and erection of 10W LED batten suitable for surface mounting prewired up to terminal block with all accessories such as drivers lamp holders, lamp etc. with acrylic diffuser and with decorative end caps and all related accessories like rods for suspension, wires etc. (CROMPTON GREAVES LDLL10 or equivalent type of CROMPTON GREAVES/ PHILIPS /GE / WIPRO/ HAVELLS/ BAJAJ).
Supply and erection of 36W LED TYPE light fittings suitable for recess mounting all required accessories for fixing and connecting the fitting to the point. (conf. Room) (Philips RC380B LED36S -6500 G4 L60 W60 PSD OD WH OC or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj).
Supply and erection of LED Strip light with suitable strip driver with all required accessories for fixing and connecting the fitting to the point (Wipro D42865-1 or equivalent type of Crompton Greaves/ Philips /GE Lighting Ltd / WIPRO/ Havells /OSRAM/ Bajaj).
Supply and erection of Weatherproof, 45W LED type well glass lighting fixtures with double compression cable glands and all accessories. All external hardware shall be stainless steel. Supply scope shall also include supply of cable lugs required for termination of cables, switches along with metallic box and cover plate. Erection scope shall also include glanding of cable at the light fitting and at the switchboard. (FCG Type No: LW 51125 or equivalent type of BALIGA/FLAMEPROOF EQUIPMENT/FLEXPRO/SCG) (Pump room).
230 V, single phase and neutral, 16A, socket outlet in cast Aluminium IP 55 weatherproof enclosure with integral TPN switch plug socket arrangement (2P+E configuration), cable glands, cable entries, plug top, duplicate earthing terminals, safety interlock to prevent accidental removal of plug while the unit is ON, provision for looping to another unit etc. The incoming cable size shall be 3C x 4 sq.mm YFY/ YWY cable. All external hardware shall be stainless steel.
Supply and erection of 1200mm sweep ceiling fans, capacitor type complete with standard length down rod, canopies, shackle, rubber bush, blades etc. Fan shall be suitable for operation on 230V, 50Hz single phase AC supply conforming to IS-374 completely prewired up to terminal block. (HAVELLS model Velocity ES 50 or equivalent).
Supply and erection of Heavy duty, totally enclosed motor industrial type EXHAUST FAN suitable for operation on 230Volts, 50Hz single phase AC supply complete with standard length of 3 core flexible copper conductor cable, and of 230 mm sweep conforming to IS-2312 (with latest amendments). Supply scope shall also include supply of switches along with metallic box and cover plate. Erection scope shall also include glanding of cable at the fan and at the switchboard.
Supply and erection of non-metallic range EXHAUST FAN suitable for operation on 230Volts, 50Hz single phase AC supply complete with standard length of 3 core flexible copper conductor cable, and of 250 mm sweep. (Havells Ventil Air - DX White or equivalent).
Supply and erection of 1.0 TON split type inverter AC unit with copper condenser and voltage stabiliser of suitable capacity (with BEE label & BEE star rating not less than 5 star).
Supply and erection of 240V, single phase, 400 mm sweep, minimum 2000 RPM speed, copper-wound wall mount type fan with all accessories such as control switch, nuts, bolts, etc.
Supply and erection of 160W Mixer Amplifier with 5Mic input channels, 2 auxiliary inputs with Preamp output, Line output and a Line input, with 2-way power source (AC mains and 24V DC), Speaker terminal block, earthing terminal etc. along with all required accessories for proper functioning of the system. (Ahuja AMPLIFIER SSA160EM 160W high power, (PA Systems) or equivalent).
Supply and erection of Wireless microphone with one body pack transmitter, one handheld dynamic unidirectional transmitter and receiver along with all required accessories for proper functioning of the system. (AHUJA AWM 520VHL or equivalent).
Supply and erection of 32W high fidelity Wall mountable speakers, 100V multipurpose PA speaker system with power taps (AHUJA PS 500T or equivalent) Scope of erection shall aslo include laying of FR PVC insulated, twin core copper conductor (Flexible) Industrial Speaker cable 2×0.75 sq. mm through PVC conduits of 20mm dia.
Supply and erection of 65inch Ultra HD (4K 3840*2160) LED Smart Android TV with 2 years full warranty coverage. The TV shall have minimum specification of 2 USB ports, 2HDMI Ports, Ethernet Port with Wi fi and bluetooth connectivity, 2 speakers. TV shall have 2GB RAM and 16GB internal storage. (Redmi smart TV X65 or equivalent).
Supply and erection of High-Speed Short Collar HDMI 2.0 Cable compatible with Ethernet Projector, Monitor, Television, Personal Computer. Erection scope shall also include laying of HDMI cable through suitable dia PVC conduit.
Supply and erection of cable manager with flip open cover and multi format cables.The cover of Desktop socket could be opened and flip closed. Connectivity options shall include 2Nos Universal power, 1 No USB charger, RG 45 Network cable, VGA port, HDMI 2.0 Cable, 3.5mm Audio cable, TYPE-A USB cable. Supply scope shall also include cables required for connecting USB port, 3.5mm audio jack, VGA cable, LAN cable of required length for connecting the cable manager to the wall mount TV. All required types of connectors and termination of cables shall also be included in the scope of supply. Suitable dia PVC conduit shall be laid on floor for laying of cables.
Supply and erection of POP-UP type sockets mounted in POP-UP boxes (LEGRAND 054011 or equivalent) in conference table. Each set shall include 2 Nos of 6A socket (LEGRAND 573470 or equivalent) in suitable installation kits (LEGRAND 054006 or equivalent).
Supply, fabrication, erection, fixing, epoxy painting and handing over of structural steel items as per drawings enclosed for racks, risers and tray supports, pedestals, DB supports, supports for other equipment, etc. as required. The painting shall be with two coats of epoxy paint over 2 coats of suitable epoxy primer. For other requirements refer sl no. 5.0 of Annexure.
Supply, Erection, Testing, Commissioning and Handing over of maintenance free copper bonded earthing system approved by Kerala state Electrical Inspectorate, comprising of 3 m long, dia. not less than 17 mm, earth electrode of low carbon steel with 250-micron copper bonding on outer surface and having terminals to connect the conductor. The electrode shall be surrounded with suitable environment friendly carbon-based back fill compound. Refer sl no. 6.0 of Annexure.
Supply and erection of PVC covered Aluminium conductors of size 16 sq.mm for DB earthing.
Making wall openings in brick wall of thickness 300mm or below for the purpose of laying cables, and replastering. The charges furnished shall cover supply of all required materials except cement. For other requirements refer sl no. 1.0 of Annexure.
Supply and installation, laying and fixing of 100mm NB Class B GI pipe. The scope shall also include fabrication, bending, welding, etc. wherever applicable. For other requirements refer sl no. 1.0 of Annexure.
MBM ENGG WORKS
SB CONSTRUCTION AND TRAVELS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .