| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L-1 | |
| 2 | L2₹3.0 L+₹2,300 (0.77%)Rejected-Finance 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | L2 | Rejected-Finance Being Other than Lower One | |
| 3 | L3₹3.0 L+₹3,300 (1.10%)Rejected-Finance 14 VEDRAJ COMPLEX GAUTAM BUDH MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L3 | Rejected-Finance Being Other than Lower One | |
| 4 | L4₹3.0 L+₹6,300 (2.11%)Rejected-Finance | L4 | Rejected-Finance Being Other than Lower One |
Tender Value
₹3.0 L
Closing Date
3 Jan 2022, 6:00 pmClosed
GE EAST KUCKNOW
GE EAST KUCKNOW
Job Work for Improvement of internal Electrification at Offs Mess, HQ 41 Inf Bde (Bldg No 6A and 6B ) under GE(E) Lucknow
2021_MES_497471_1
3001/11/E3
Limited
Miscellaneous Services
Works
30 days
GE EAST KUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
11 Aug 2023
25 Dec 2021
4 Jan 2022
25 Dec 2021
3 Jan 2022
27 Dec 2021
Amount
Job Work for Improvement of internal Electrification at Offs Mess, HQ 41 Inf Bde (Bldg No 6A & 6B ) under GE(E) Lucknow. (a) Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed - 177 Each (b) M&L for one light/fan/exhaust fan/holder point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked not less than 19.5 mm / 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators as per specified SSR and as directed by Engineer- in- Charge. . NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls - 59 Each (c) S&F socket outlet 5 Amp 5 Pin 240 volt flush type all as specified - 59 Each (d) Wall mounted fancy light fitting brass made (double light) bracket with 130mm x 95mm decorative oval shape base, two brass arms 305mm length brass nickel plated. Make:- Mepro Cat No- MBBD 900 -16 Each (e) M&L for wiring with two single core 10 sqmm multi-stranded copper conductor PVC FRLS insulated and unsheathed cable ISI marked drawn through in and including PVC conduit medium grade concealed in wall for sub main connection including 10.0 Sqmm PVC insulated unsheathed stranded copper conductor as earth wire all as specified. Make- Seiko /Havells /Paragon /finolex/HPL/Plaza - 150 RM (f) Supply and fixing in repairs LED Building security light 36W IP 65 including one number MS clamps made of 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting, connecting with three core copper flexible wire 23/0.0076 complete. Make-Philips/CG/Bajaj - 16 Each (g) Supply & fixIing exhaust fans AC single phase 230/ 240 V of size 300 mm sweep pvc body with louver with complete making a hole including civil work neccassary connection with the required wire complete all as specified and directed - 03 Each (h) Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed Make :-Legrand, Cat No. 5077 50 & 5079 38 or equivalent in Hager, Cat No : VYV04PM & VYV00E or Schneider, Cat No : A9HVD04M & A9HVDXXWB and comprising of the following: (i) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make :-Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No : HDA126Z or Schneider, Cat No : LV516312. (ii) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos. Make :-Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No. NCN106N to NCN132N or Schneider, Cat No. A9N1P06C to A9N1P32C - 01 Each (j) Supply and fixing as in repair MCB DB TPN (double door) 4 Ways, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge - 02 Each (k) Supply & Fixing in replacement isolator four pole 415 volts, 125 Amps, curve 'C' of breaking capacity 10KA complete all as specified - 02 Each (l) Supply and fixing in repairs LED tube light along with fixture including one number of 20 watt 4' LED tube complete all as directed by Engr-in-Charge - 24 Each (m) Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge - 04 Each (n) Supply and fix Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed - 04 Each (o) Supply and Fixing in replacement MCB, single pole, 240 Volts, curve 'C' of capacity (6-32 Amps) as ordered breaking capacity 10 KA - 60 Each (p) Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts, curve 'C' of breaking capacity 10KA complete all as directed - 05 Each (q) M&L for wiring with two single core 6 sqmm multi-stranded copper conductor PVC FRLS insulated and unsheathed cable ISI marked drawn through in and including PVC conduit medium grade concealed in wall for sub main connection including 6.0 Sqmm PVC insulated unsheathed stranded copper conductor as earth wire all as specified. Make- Seiko /Havells /Paragon /finolex/HPL/Plaza - 150 RM (r) M&L for renewal of earthing complete with galvanised steel earth plate electrod 60cmx60cmx6mm thick burried directly in ground ( earth ) pit not less than 2.25mtr below normal ground ( level ) connected to and including using galvanised iron strip 25×4mm as earthing lead by means of bolts nuts check nuts and washers of galvanaised iron or steel including PCC pit in 1:2;4 type B-1 RCC cover with suitable handle and angle iron 40x40x5mm frame, excavation and earth work in any type of soil, medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade protetion pipe 15mm bore upto main board complete as shown on electrical plate No 5 of MES Sch 1991 ( part-I) and testing and completion - 01 Each
HS ASSOCIATES
M/s Arora Trading Co
B N SRIVATAVA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .