| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC DOOR NO 58 18 29 NARASIMHA NAGAR BUTCHIRAJU PALEM NEAR RAMAKRISHNA PUBLIC SCHOOL GOPALAPATNAM RURAL VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.5 L+₹2.0 L (6.03%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹35.6 L+₹2.1 L (6.29%)Rejected-AOC 24 85 7 SANATH NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹35.9 L+₹2.4 L (7.10%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹36.9 L+₹3.4 L (10.2%)Rejected-AOC 37 10 149 1 AYYAPPA NAGAR MURALINAGAR EAST VISAKHAPATNAM 530 007 INDIA | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
20 Feb 2023, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVN OF FALSE CEILING WALL PANELING LIGHT FITTING AND AIR CONDITIONING AT P 15 321 HANGAR PROVISION OF PATHWAY AT IAAMS AND PROVISION OF CHEMICAL EARTHING FACILITY AT INS DEGA VISAKHAPATNAM
2022_MES_556786_2
8216GEND
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ND VIZAG
₹92,000
9 May 2023
6 Feb 2023
25 Feb 2023
6 Feb 2023
20 Feb 2023
13 Feb 2023
Amount
M& L for False ceiling with PVC tiles made out of 5mm thick PVC sheet with design as approved by GE , suitably placed in false ceiling grid of anodised aluminium snap grid of size 605 x 605 mm frame work with hangers 6 mm dia GI (upto 1200mm length) adjustable level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed .
S&F for solid PVC wall lining consisting of 5mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusiuve of fixing on to wall to make PVC frames complete all as specified and directed
Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit totally concealed in walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including 2.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point/exhaust fan point controlled by one switch complete all as specified and as directed. Note:-(i) All the disturbed surfaces of wall / ceiling shall be made good to match the existing wall / ceiling finishes and the rate also include all the cutting, chasing and cementing work for concealed wiring complete as directed by the Engineer-in-Charge.
All as per item No 5 above but for one socket outlet, three pin, 5/6 Amp, independent complete all as specified and directed.
All as per item No 5 above but for 15/16 Amp switch socket out let, independent with 4.0 sqmm copper conductor cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed.
Supply and fixing Modular switch 1 way 6A, 1 module single pole complete all as specified and directed .
Supply and fixing Modular switch 1 way 16A, 1 module single pole complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65 x 30 mm with 3 terminals complete all as specified and directed
Supply and fixing of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified and directed.
Supply and fixing of Socket 6A&16A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified and directed.
Supply and fixing of modular Fan step regulator, 120W - 2 module complete all as specified and directed.
S & F LED tube light fittings,batten type professional WH 5700K to 6200K and minimum 18W of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed .
S & F Square recessed mounted LED light (2'x2') of minimum 35/36 W warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed .
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sqmm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified and directed.
Supply and fixing of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 12 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sqmm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified and directed.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and directed
Supply and fixing of MCB 63Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, , complete all as specified and directed.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified and directed
M&L for sub main wiring with two run of 6.0 Sqmm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0 Sqmm drawn through and including PVC concealed conduit of 25 mm dia, including taking down old wiring complete all as specified and directed. Note: (i) Copper conductor 2 runs and one run of copper earth wire along with PVC concealed conduit shall be measured as one length (ii) Cutting of chases/walls and making good the disturbed surfaces as per original shall be deemed to be included in the rate.
M&L for sub main wiring with two runs of 4.0 Sqmm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sqmm as earth wire drawn through and including PVC concealed/surface conduit of 25 mm dia, including taking down old sub main wiring of any type, complete all as specified. Note: (i) Copper conductor 2 runs and one run of copper earth wire along with PVC concealed conduit shall be measured as one length (ii) Cutting of chases/walls and making good the disturbed surfaces as per original shall be deemed to be included in the rate.
Taking down ceiling fan from its position and doing complete overhauling of fan including replacement of fan clamp and split pin, rubber bush, 02 no canopy, fan capacitor of 2.5mfd, 02 no bearings of suiable size, shaft and winding with suitable copper wire and other spares including painting with synthetic enamel paint over a paint of primer refixing the same after repairs complete all as specified and directed .
Taking down Exhaust/wall mounted fan of any size from its position and doing complete overhauling of fan including replacement of fan clamp and split pin, rubber bush, fan capacitor of 4.0mfd, 02 no bearings of suiable size, shaft and other spare parts including painting with synthetic enamel paint over a paint of primer and refixing the same after repairs complete all as specified and directed . .
S & F modular power unit of capacity 20 Amps complete for ACs with a two pin and earth plug and socket complete with one MCB, single pole, 20 Amps, 240 volts, 'C' curve, 10 KA complete all as specified and directed.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh,15mm dia light grade GI pipe for protection of GI earth wire complete all as directed.
Supply, installation , testing and commissioning of BEE 5 star rated hi-wall split units indoor/outdoor with cordless remote control unit and with in built filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil, EER 3.2 of capacity 1.5 TR all as specified and directed by the Enginer-in-Charge. Note : 1.The Quoted rate shall deemed to be inclusive of supply and fixing of bracket for fixing of indoor and outdoor unit in wall at any height as directed . 2. The copper tube of suitable size up to 5mtr (for each ACs) shall deemed to be inclusive in quoted rates and copper tubes if required in quantity more than 5 metre per AC shall be measured and paid separately under respecitive item of this schedule.
Supply, install, testing and commissioning of BEE 5 star rated hi-wall split units indoor/outdoor with cordless remote control unit and with in built filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil, EER 3.2 of capacity 1.0 TR all as specified and directed Note : 1.The Quoted rate shall deemed to be inclusive of supply and fixing of bracket for fixing of indoor and outdoor unit in wall at any height as directed . 2. The copper tube of suitable size up to 5mtr (for each ACs) shall deemed to be inclusive in quoted rates and copper tubes if required in quantity more than 5 metre per AC shall be measured and paid separately under respecitive item of this schedule.
Supply and fixing Voltage stabilizer of capacity 4 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed .
Supply, laying and testing of cable , XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4.0 core laid in trenches or under floors etc complete all as specified and directed
Excavation in trenches, not exceeding 1.5m in width and not exceeding 1.5 m in depth, for foundation or for laying of pipes not exceeding 10 sqmtr on plan and getting out in any type of soil soil,complete all as specifed and directed.
Returning, filling-in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm using excavated soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Removing excavated materials to a distance exceeding 250 metre but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning of cables using natural river sand, 23 cm thick layer punned down to 18 cm thickness including spreading and punning down complete all as specified and directed Note : punned thickness only shall be measured for payment purpose.
Supply and laying in trenches un- reinforced pre cast concrete cable cover class LV,type I, flat size 250x150x40 mm complete all as specified and directed
M & L cutting of existing road/ floor/ plinth for laying of pipe line of dia 150mm to 200mm pf any type complete all as specified and directed
Material and labour for 50 mm dia steel water tubes 'light grade' galvanised for cable protection including sealing both ends complete all as specified and as directed .
Supply and fixing of MCCB 16 KA 63 Amps, 4 pole complete all as specified and directed
Supply only moorum for filling in Embankment ,floors or paving , laid in layers not exceeding 15 cm thick, spread levelled and rammed including watering complete all as specified and directed Note:- Labour for laying of mooram shall be measured and paid under Item No 47
M&L hardcore of broken stone or boulders of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed
M&L for cement concrete type D2 1:4:8 using 40 mm graded crushed stone aggregate in foundation filling and mass concreting complete all as specified and directed
M&L for 150mm thick plain cement concrete type B2 1:2:4 using 40mm graded crushed stone aggregate as in hardstanding including necessary formwork complete all as specified and directed
M&L for brick work with flyash bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even & smooth without using extra cement complete all as specified and directed
M & L preparing plastered or unplastered new surfaces by using vaccume based hand held or long handle sander machine and applying Three coat of white wash on walls/ceiling and cornices complete all as specified and directed
M & L for Plain Cement Concrete Type C1, 1:3:6 (using 20 mm graded crushed stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, bonds and the like including weathering including necessary form work, complete all as specified and directed
Labour only for Forming embankment including raising (or lowering) earth,spreading in layers n exe 30cm thick watering, ramming/rolling and finishing to required size, shape, etc not exceeding 1.5m high from base complete all as specified and directed Note:- (i) Soil for forming the embankment shall be used from soil obtained from excavation vide Item no 30, Morram from Item No 39 and balance quantity of soil from the soil already availaible at site and the quoted rates shall be for labour only of forming embankment. (ii) Removal of soil availble at site to the embankment location if required shall be measured and paid under item no 32 and 33 as applicable at site. (iii) Tenderers are advised to visit the site and quote their rates accordingly , nothing extra shall be admissible on this account at any later stage.
M & L for Chemical Earthing with UL listed Copper bonded rod of 254 microns coating thickness and 3.048 mtr length . Cross section of the earth electrode shall be 490 sq.mm. Earth rod clamp of required size should be made up of copper bonded material. Earth enhancement compund of 50kg producing low resistance below 0.018 Ω mtr of an earth termination system. Material of the earthing enhancing compound shall be chemically inert to subsoil. It shall not pollute the environment.The compound shall be tested and certified as per IEC 62561-7 .Earth Chamber Should have an outer dimension of 300 mmX 300 mm X 200 mm made of polypropylene material . Flush Mounted, removable and lockable cover of the earth pit should be able to withstand 50kN. Installation of earth electrode can be done by means of core cutting and auguring (bore well) complete all as specified or indicated including testing on completion and as directed. [Note:(i) The unit rate shall be deemed to include for excavation & earth work in any type of soil, RCC Concrete floor core cutting of around 3ft depth and borewell for 3mtrs and cementing the same to floor level.
Supply and fixing copper strip of size 20X 3 mm with saddles with required porcelian insulator , fixing screws etc. for roof conductors and down conductors complete all as specified and directed.
Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
Supply and installation of Cable Drum with 20 meters of single core 6 sq.mm copper Flexible cable fixed with crocodile clip. Cable drum should be made up of high-grade thermoplastic material with 310 mm diameter & operating knob for drum rotation . It should be shock proof & thermal excursion. Fixed in portable stand for easy handling. Cable drum should be wound with said flexible cable. complete all as specified and as directed.
Material and labour for cutting existing road /PCC /drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC 1:3:6 type CI using 20mm graded crushed stone aggregates complete all as specified and directed.
M/s SIRI CONSTRUCTIONS
V R K CONSTRUCTIONS
SREE VIGNESWARA CONSTRUCTIONS
PRADEEP ENTERPRISES
CIVILEC ENGINEERING WORKS
MVV Prasad
V SURYA PRASAD REDDY
RAJASHEKHAR ENTERPRISES
SRI SAI KRISHNA ENGINEERING WORKS
N V S S K N SIVA PRASAD
HUSSAIN ENGINEERING WORKS
SERVO-TECH ENTERPRISES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .