Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24 LAccepted-AOC 147 A BASEMENT SANT NAGAR EAST OF KAILASH NEW DELHI 110 065 | SOUTH | DELHI | 110065 | ₹24 L | L1 | Accepted-AOC L1 |
| 2 | L2₹35 L+₹11 L (45.8%)Rejected-Finance | ₹35 L+₹11 L (45.8%) | L2 | Rejected-Finance L2 |
| 3 | L3₹37.5 L+₹13.5 L (56.3%)Rejected-Finance | ₹37.5 L+₹13.5 L (56.3%) | L3 | Rejected-Finance L3 |
| 4 | L4₹47.9 L+₹23.9 L (99.6%)Rejected-Finance UNIT NO 205 PENINSULA CENTRE CO OPERATIVE PREMISES SOCIETY LTD DR S S RAO ROAD PAREL MUMBAI 400 012 | MUMBAI | MAHARASHTRA | 400012 | ₹47.9 L+₹23.9 L (99.6%) | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Dec 2024, 3:00 pmClosed
P K Gupta Chief Construction Engineer
CCE R AND D WEST PUNE
Preliminary Consultancy Services for Preparation of DPR for Upgradation of Power Dustribution System, Air Conditioning Plants, Revamping of Fire Fighting System, and Creation of Drainage System and Augmentation of Perimeter Road at Acem Nashik
2024_DRDO_837207_1
CCEW/C2/20052/UPGRA/NSK/2024
Limited
Consultancy
Item Rate
90 days
ACEM NASIK
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
CCE R AND D WEST
₹50,000
Yes
24 Jan 2025
29 Nov 2024
14 Dec 2024
30 Nov 2024
13 Dec 2024
7 Dec 2024
2 Dec 2024 - 6 Dec 2024
Amount
CONSULTANCY SERVICES (all as per Tender enquiry & Scope of Work; including GST as applicable and refer Appendix 'A' scope of consultancy services and as per para
Details planning, engineering and design with line plans and schematic drawings, layout including preparation of DPR, master plan, bill of quantities, estimation, Approximate Estimate Part I & II based on DSR/Market with analysis and supporting documentation etc., complete for following works :- a) Survey and assessment of feasibility for construction of perimeter road adjacent to the existing boundary wall at some of the low lying /steeper/undulated locations. b) Preparation of complete drainage plan in ACEM technical area. Feasibility of provisioning and connecting storm water drain and disposal of storm water away from buildings and from defence land / connecting to the culverts and suggest corrective measures for restricting /Diverting water flow towards the buildings specially having under ground pits (Total area – 600 Acres Approximately) c) survey/Assess existing HVAC system thoroughly and suggest the necessary rectification, replacement, upgradation etc and suggest if any corrective/rectification measure for smooth functioning of system at ACEM Nasik (including BOQ with estimate). Augmentation and upgradation of central Air conditioning of of AHU’s Water & Air cooled chillers, VRF units etc complete (Total Tonnage Approx -1600 TR) d) Review existing hardware, LT panel, Electric mains and sub-mains power layout and controls; and suggest comprehensive distribution plan including specification and layout for Main Panels and sub-Distribution panels etc. considering existing and proposed buildings and services. Detailed investigation and Examination of existing Electrical power supply Network and collect the information regarding further requirement and suggest if any corrective/rectification measure including power back up system, for smooth functioning of system at ACEM Nasik (including BOQ with estimate). Augmentation and upgradation of 33 KV/11 KV line including ring main connected through PLC controlled MRS & Substation (11 KV/415V), Distribution of loads and corrective measures and report on health conditioning of Transformer 02 Nos – 2000KVA), 1000KVA DG Set, VCB’s all other connected substation equipments and panels etc., complete. e) Detailed investigation and Examination of existing Fire Fighting /Hydrant and Fire Alarm system thoroughly and suggest the necessary rectification replacement, upgradation etc and suggest if any corrective/rectification measure for smooth functioning of system including for further requirement for assets at ACEM Nasik (including BOQ with estimate). Augmentation and upgradation of Fire fighting System including ring main system, deluge system inside Technical buildings and functionality test and corrective measures and report on health conditioning of deluge, pumps and Fire fighting pump house etc complete (Total Existing length 25 km Approximately). f) Detailed investigation and Examination of existing External Water Supply system thoroughly and suggest the necessary rectification replacement, upgradation etc and suggest if any corrective/rectification measure for smooth functioning of system including for further requirement for assets at ACEM Nasik (including BOQ with estimate). Augmentation and upgradation of water supply system with in ACEM campus including functionality test and corrective measures and report on health conditioning of water treatment plant and pumps etc complete (Total Existing length 20 km Approximately). g) Identification of Ground water level at 05 (five) location through GSDA (Ground water survey and Development agency), Govt of Maharashtra OR any other approved agency)
Carrying out topographical survey of the area with total station, giving traverse of surveyed area, spot levels at 10.0m x 10.0m center to center interval, land, marking of existing major structures, alignment of existing roads, other structures/ details and major trees with girth more than 30cm at 1.00M above ground level, showing contours at 1.00m interval etc all complete including culverts and with invest level existing drain and submission of Topographical (10m X 10.0m grid) survey with 1.0 meter contour interval. Master plan indicating the buildings with finished floor level cross drainages, culverts, road site drain with invest levels, road top level, at all junction and in front of buildings, marking of all above ground level features etc complete.
Architects Chamber (BID ID -3136829)
Harrysons Consultants Private Limited (BID ID -3135553)
DID CONSULTANTS (BID ID -3136518)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .