Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹1.1 LAccepted-AOC | l1 | Accepted-AOC L1 |
Tender Value
₹1.1 L
EMD Value
₹2,790
Closing Date
4 Mar 2026, 3:00 pmClosed
Assistant Executive Engineer
O/o Office of the Assistant Executive Engineer,Electrical Sub Division Pathanamthitta, (For and on behalf of Governor of Kerala)
DEPOSIT- Running maintenance contract for AC units at Goverment Guest house Pathanamthitta 2024-25-Electrical AC Work
2026_PWD_835066_2
PWD/BLDG/TR/13724/2024
Open Tender
Electrical Works
Percentage
365 days
Pathanamthitta
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹2,790
25 May 2026
25 Feb 2026
7 Mar 2026
25 Feb 2026
4 Mar 2026
25 Feb 2026
OD99606/2024-2025:Charges for Servicing Air Conditioner Units such as cleaning using chemical materials and water. Cleaning air filter, attending petty repairs to copper tubes leak testing, rectifying defects if any and making the unit in proper working condition.-for Split (High Wall) type Units/for Split (floor mounting) type Units/for Ductable Split / cassette type: ( Each A/c unit service 4 times per year)
OD99607/2024-2025:Charges for filling sufficient quantity of R22/410A/R32 refrigerant for air conditioner unit including leak testing, leak arresting, brazing etc. if required and make the unit in good working condition for the following. 1TR/1.5TR/2TR/3TR
OD99608/2024-2025:Supply and install PCB board suitable for 2TR/1.5TR/1TR non-inverter type AC in the place of defective one.
OD99609/2024-2025:Supply and renewal of defective inverter PCB suitable for 1.5 ton inverter split AC unit as required
OD99610/2024-2025:Dismantling of PCB board of voltage stabilizer and refitting after necessary repairs - for 1TR/1,5TR/2TR AC
OD99611/2024-2025:Supply and installation temperature sensor (Room / condenser / Coil ) suitable for 1TR/1.5TR/2TR/3TR in the place of defective one
OD99612/2024-2025:Supply and renewal 4µF or suitable capacitor for fan motor of 1TR/1.5TR/2TR in the place defective one
OD99613/2024-2025:Supply and renewing the following accessories suitable for AC unit. Running capacitor (45µF/440V or nearest)
OD99614/2024-2025:Supply and renewal of Cu flare nut suitable for 1TR/1.5TR/2TR/3TR in the place of defective one
OD99615/2024-2025:Supply and renewal outdoor fan motor suitable for 1TR/1.5TR/2TR in the place of defective one
OD99616/2024-2025:Supply and installation of metal fan leaf suitable for 1TR/1.5TR/2TR in place of defective one
OD99617/2024-2025:Supply and installation copper condenser coil in OD unit of 1TR/1.5TR/2TR AC in the place of defective one
OD99618/2024-2025:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.525 mm) and 5/8 inch (15.875 mm) 22 gauge
OD99619/2024-2025:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
OD99620/2024-2025:supply and providing the indoor unit remote of Single phase 1 TR/ 1.5 TR/2TR/3TR (Blue star/Voltas/ equivalent ) Wall mounting split A/C unit.
OD99621/2024-2025:Supply and providing rubberized foam sleeve 10mm thick over existing piping between indoor and outdoor unit of AC unit
OD99623/2024-2025:Supply and installation of automatic stabilizer suitable for 1.5 TR AC unit with working voltage range of 170 V - 270 V AC, current capacity of 12A, indicators, suitable for wall mounting etc. as required. (V-Guard VG 400 or equivalent)
OD99624/2024-2025:Supply and renewal of defective strainer and capillary tube for split AC unit including cutting, brazing etc. as necessary.
OD99625/2024-2025:Supply and renewal of single pole contactor 25A or nearest suitable for 1/1.5/2 Ton AC unit
OD99626/2024-2025:Supply and renewal of Rotary compressor for 1.5TR A/C
OD99627/2024-2025:Supply and renewal of Rotary compressor for 2.0TR A/C
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1416464.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd1_merged.pdf
Tender Documents • 1.66 MB
BOQ_1416464.xls
BOQ • 0.33 MB
CORRIGENDUM.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .