| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC AWARDED | |
| 2 | Rejected-Technical | - | Rejected-Technical TECHNICALLY NOT OK | |
| 3 | Rejected-Technical | - | Rejected-Technical TECHNICALLY NOT OK |
| Sl No | Description | Qty | Unit | M/S ANANT ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00[a] sub-assembly room repair section at excavation shed of base workshop, [b] sub-assembly room auto section at excavation shed of base workshop, [c] sub-assembly dozer section at excavation shed of base workshop, [d] LMV supervisor's room at E&M shed of base workshop, and [e] challan ghar being constructed at section-II (new patch) of Rajrappa opencast project. | ||||
| 2.00Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. | ||||
| 2.10 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 120 | meter | 208.71 ₹25,045.2 Lowest |
| 2.20 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 60 | meter | 249.35 ₹14,961 Lowest |
| 3.00Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | ||||
| 3.10 | 5/6 A switc | 35 | each | 45.03 ₹1,576.05 Lowest |
| 3.20 | 3 pin 5/6 A socket outlet | 8 | Each | 61.51 ₹492.08 Lowest |
| 3.30 | 15/16 A switch | 8 | Each | 108.75 ₹870 Lowest |
| 3.40 | 6 pin 15/16 A socket outlet | 8 | Each | 124.13 ₹993.04 Lowest |
| 4.00Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. | ||||
Tender Value
₹3.4 L
EMD Value
₹4,400
Closing Date
16 Jun 2025, 6:00 pmClosed
SO ENM
SO ENM OFFICE RAJRAPPA
wiring of a sub-assembly room repair section at excavation shed of base workshop , sub assembly room auto section at excavation shed of base workshop , sub assembly dozer section at excavation shed of base workshop d,LMV supervisor s room at EnM shed
2025_CCL_336580_1
GM(R)/ SO(ENM)/Rjp/25-26/Et/31 dt 03.06.25
Open Tender
Electrical and Maintenance Works
Item Wise
20 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,400
27 Aug 2025
3 Jun 2025
17 Jun 2025
4 Jun 2025
16 Jun 2025
4 Jun 2025
4 Jun 2025 - 7 Jun 2025
Amount
[a] sub-assembly room repair section at excavation shed of base workshop, [b] sub-assembly room auto section at excavation shed of base workshop, [c] sub-assembly dozer section at excavation shed of base workshop, [d] LMV supervisor's room at E&M shed of base workshop, and [e] challan ghar being constructed at section-II (new patch) of Rajrappa opencast project.
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switc
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
12 Module (200mmX150nnm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75 mm X 75 mm X 60 mm deep
Supplying and fixing 5A to 32 A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250volts including connections with all necessary material complete of approved as required confirming to IS:374/2019 with upto date amendments. 1200 mm sweep
Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp up to 6500K & having 50000 burning hrs life with minimum@L70, system lumen output should be minimum with efficacy>100lm/Watt. LEDdriver PF>0.95, THD<20%&surgeprotection4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder-coated frame with glare-free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required.
[b] sub-assembly room auto section at excavation shed of base workshop.
[b] sub-assembly room auto section at excavation shed of base workshop.
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
12 Module (200mmX150nnm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75 mm X 75 mm X 60 mm deep
Supplying and fixing 5A to 32 A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250volts including connections with all necessary material complete of approved as required confirming to IS:374/2019 with upto date amendments. 1200 mm sweep
Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp up to 6500K & having 50000 burning hrs life with minimum@L70, system lumen output should be minimum with efficacy>100lm/Watt. LEDdriver PF>0.95, THD<20%&surgeprotection4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder-coated frame with glare-free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required.
c] sub-assembly dozer section at excavation shed of base workshop
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
12 Module (200mmX150nnm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75 mm X 75 mm X 60 mm deep
Supplying and fixing 5A to 32 A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250volts including connections with all necessary material complete of approved as required confirming to IS:374/2019 with upto date amendments. 1200 mm sweep
Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp up to 6500K & having 50000 burning hrs life with minimum@L70, system lumen output should be minimum with efficacy>100lm/Watt. LEDdriver PF>0.95, THD<20%&surgeprotection4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder-coated frame with glare-free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required.
[d] LMV supervisor's room at E&M shed of base workshop
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
12 Module (200mmX150nnm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75 mm X 75 mm X 60 mm deep
Supplying and fixing 5A to 32 A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required. 400 mm sweep
Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp up to 6500K & having 50000 burning hrs life with minimum@L70, system lumen output should be minimum with efficacy>100lm/Watt. LEDdriver PF>0.95, THD<20%&surgeprotection4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder-coated frame with glare-free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/connection wire, testing etc. to complete the job. LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required.
[e] challan ghar being constructed at sec-II (new patch) of ROCP
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
12 Module (200mmX150nnm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75 mm X 75 mm X 60 mm deep
150 mm X 75 mm X 60 mm deep
Supplying and fixing 5A to 32 A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MOB DB complete with connections, testing andcommissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250volts including connections with all necessary material complete of approved as required confirming to IS:374/2019 with upto date amendments. 1200 mm sweep
Supply and fixing in position LED lamp of approved make
9 Watt, 250 V
12 Watt, 250 V
Supply and erection of approved make safe earthing electrode consisting pipe-inpipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size With 3 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
providing masonry enclosure with cover plate having locking arrangement and as required.
Providing and fixing 25mmX5mm G.I. strip on surface or in recess for connections etc. as required.
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .