Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹3.8 L+₹40,280 (11.7%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹4.4 L+₹95,405 (27.8%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance not being lowest |
Tender Value
₹8 L
EMD Value
₹16,440
Closing Date
6 Jul 2020, 6:00 pmClosed
GE SOUTH PATHNAKOT
GE SOUTH PATHANKOT
OUTSOURCING FOR ATTENDING DAY TO DAY COMPLAINTS OF REPAIR/MAINT OF SUMMER AND WINTER COOLING APPLIANCES AT 167 MH OF DHANGU COMPLEX UNDER GE (SOUTH) PATHANKOT
2020_MES_351531_1
GES/PKT/T-05/2020-21
Open Tender
Manpower Supply
Item Rate
334 days
167 MH
OUTSOURCING FOR ATTENDING DAY TO DAY COMPLAINTS OF REPAIR/MAINT OF SUMMER AND WINTER COOLING APPLIANCES AT 167 MH OF DHANGU COMPLEX UNDER GE (SOUTH) PATHANKOT
9 documents required · 9 mandatory
₹500
Yes
GE SOUTH PATHANKOT
₹16,440
Yes
21 Aug 2020
10 Jun 2020
7 Jul 2020
10 Jun 2020
6 Jul 2020
23 Jun 2020
10 Jun 2020 - 17 Jun 2020
Amount
Outsourcing for attending day to day complaints/breakdown of winter heating appliances such as electric water heaters storage type (geysers) of any capacity/type/model/make, summer cooling cooling appliances such as refrigerators, deep freezers, desert coolers, window/split ACs, water coolers of any capacity/type/model/make, complete by deploying one skilled Ref/ Mech and one semi skilled Ref/Mech in a shift of 08 Hours duty including on all days including Sunday/Gazetted Holidays complete for carrying out the following jobs as specified and directed .
a) Carrying periodical servicing to the equipments complete such as electric water heaters storage type (geysers) (winter heating appliances) and summer cooling appliances such as refrigerators, deep freezers, desert coolers, window/split ACs, water coolers of any capacity/type/model/make before one month of commencement of season (i.e Servicing of Winter heating Appliances to be completed by end of Dec and Servicing of Summer cooling Appliances to be completed by end of May)
b) Attending day to day complaints of winter heating appliances and summer cooling appliances carrying out repairs and replacement of spares.
c) Maintaining Repair/Maint register and job Cards etc complete all as directed.
d) Cost inclusive of minor spares such as nut, bolts, washers, lubricants, anchor bolts, flexible copper conductor wire for connections, plug tops, insulation tape, ferrules etc . Major spares will be measured and paid separately.
e) Quoted rate inclusive of strip opening of electric water heaters storage type (geysers) , refrigerators, deep freezers, desert coolers, window/split ACs, water coolers of any capacity/type/model/make for assessing the serviceablity of spares, replacement of spares which shall be measured and paid separately, re-assembling, testing and commissioning etc complete all as specified and directed.
f) Quoted rate inclusive of de-scaling of geysers of capacity 25/50 ltr after taking down the geyser from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of geysers complete during day to day complaints complete all as specified and directed.
g) Quoated rate inclusive of repairs to refrigerant lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehydrating, Vaccumissing, charging of Refrigerant gas and testing etc complete. Major spares will be measured and paid separately.
Note :- i) Total 02 Number of Refg/Mech both skilled and semi skilled are required to be depolyed in one shift of 8 hours duty per day on all days including Sunday/Gazetted Holidays. ii) The quoted rate deemed to be inclusive for provision of reliever duty and leave periods. (iii) Antecedents of the Personnel engaged by the contractor to carry out the work shall be verified from police authorities and accordingly security passes shall be issued. (iv) The contractor shall be solely responsible for all personnel deployed for carrying out the above jobs and all transport required for conveyance. The rate quoted deemed to be inclusive of EPF, insurance etc all as per latest norms of labour Commissioner. (v). The labourers shall be provided with protective devices and shall wear them while working. In case any accident/ injury/ fatal or partial disability happened, the contractor shall be solely responsible for settling all claims/ compensation. Department will have a right to recover any sum indicated/ claimed by Labour Commissioner/ Court directive. (vi) Contractor will render a certificate/ confirmation every month that minimum wages act is not violated and every employee engaged have been paid their wages only through individual bank account laborers in full and receipts there on obtained. The Contractor shall produce bank statements every month alongwith the Certificate. (vii)In case the contractor fails to set right break down (occurring during maintenance) or absence of operator within 02 hours, the Accepting Officer and the Engineer-in-Charge (GE and AGE E/M) shall impose penalty of Rs 500/- per hour per operator for inconvenience caused after said 02 hours period. If such penalties occurred more than twice in a month contract will be terminated, the balance portion of the year shall be got executed by other agency at the risk and cost of the contractor
Supply only the following spares of electric water heaters storage type (geysers) of any capacity/make/model for carrying out day to day repairs under sr item No.10 above:-
a) Internal SS tank of geyser 50 ltr capacity ISI marked complete with syphon –assembly, 2.0 KW element , rubber gasket , thermostat switch , all as specified and directed ., The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .)
b) Internal SS tank of geyser 25 ltr ISI marked capacity complete with syphon –assembly, 1.5/2.0 kw element , rubber gasket , thermostat switch , all as specified and directed. The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .)
c) Syphon assembly ISI marked made out of stainless of 50 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as specified and directed.
d) Syphon assembly ISI marked made out of stainless of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as specified and directed.ll as per Srl item above but 25 ltr capacity.
e) Thermostat switch ISI marked for geyser AC 230 volt adjustable range from 0-90 degree Celsius)
f) Cup type geyser element AC 230 volt, of rating 1500/2000 watt.
g) Triangular type geyser element AC 230 volt, of rating 1500/2000 watt.
h) LED indicator lamp square/round type suitable for geyser 25/50 ltr all as per sample for operation with AC 230 Volt 50 HZ supply.
j) Spring loaded air release valve ISI marked suitable for 25 and 50 ltrs capacity Geysers.
k) Safety valve / dead wt. valve ISI marked suitable for 25, and 50 Ltrs capacity geysers.
Supply only the following spares of refrigerators, deep freezers, desert coolers, window/split ACs, water coolers of any capacity/make/model for carrying out day to day repairs under sr item No10 above:-
a) Condenser fan blade of 1.5TR split/Window type AC’s of any make.
b) Condenser fan blade of 2.0TR split/Window type AC’s of any make.
c) Blower unit of any make split/Window AC of suitable type.
d) Temperature sensor probes suitable for any type, make of split/Window type AC’s.
e) Printed circuit Board for any make split/window type AC unit.
f) Sealed fan motor assly of the same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
g) Air fiilter set for split/window type AC’s of 1.5 / 2TR capacity.
h) Starting/running capacitors 80/100 MFD 230V / 50Hz of the same suitable capacity to split / window type AC’s.
j) Starting relay suitable for 1.5/2TR Window / Split type AC’s.
k) Thermostatic switch and S/F new thermostatic suitable for window type AC’s.
l) Drain pipe suitable for split type AC’s.
m) Remote control unit for split/window type AC of 1.5 / 2 TR of any make
n) Reciprocating or Rotary type compressor suitable for 1.5TR capacity Split AC unit
p) Reciprocating or Rotary type compressor suitable for 2.0TR capacity Split AC unit
q) Reciprocating or Rotary type compressor suitable for 1.5TR capacity window AC unit
r) Starting relay for any capacity water cooler.
s) over load relay suitable for any capacity water cooler.
t) Running capacitor capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
u) Starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs Capacity.
v) Running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs Capacity water cooler.
w) Thermostatic switch for water coolers of any capacity.
x) PVC float valve for water cooler of any capacity
y) Drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
z) Sealed fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity.
aa) Condenser fan blade suitable for 40/60/80 water coolers.
ab) Air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity.
ac) Refrigerant gas R-134A /R-410/R-407. Make: Mafron/ Freon/ Floron
ad) Sealed Compressor unit for Refrigerator of capacity 165 to 185 Ltrs
ae) Sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs
af) Sealed Compressor unit for Deep freezer of capacity 320 to 400 Ltrs
ag)Cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
ah) Fan motor suitable for deep freezer of any capacity including all accessories complete
aj) Blower motor suitable for desert cooler of capacity 3400 CFM to 5000 CFM single way shaft suitable for operation on 240 Volts 50 c/s complete all as specified.
ak) Water circulation pump suitable for desert cooler of capacity 3400 CFM to 5000 CFM suitable for operation on 240 Volts 50 c/s complete all as specified.
al) Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three).
an) Refrigerant gas R-22 Make: Mafron/ Freon/ Floron
ao) Compressor oil for carrying out repairs under relevant items above Make: SERVO/ Sheetal N-68 /Sandon/Equivalent
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
Schedule of credit = 15155.00
RD BUILDERS
satpal and brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .