AC Works
OD344947/2024-2025:Dismantling the existing AHU of 17 TR AC unit from its existing position after removing the electrical connections, Copper pipe connections etc. without any damages, conveying the same to ground level from AHU Room using suitable tools and plant etc. as required at site.
OD344949/2024-2025:loading, transporting the dismantled AHU unit of 17TR AC unit to the nearest AC service center, complete overhauling, repairing/replacing the defective accessories, consumables etc. if required, leak/pressure testing, and transporting to the new location without any damage including un loading
OD344948/2024-2025:Installation testing and commissioning of 17 TR AHU in new location using necessary hanging support in the RC slab ceiling, connecting copper pipes, duct assembly and giving electrical inter connections from out door unit etc complete required at site.
OD345600/2024-2025:Dismantling the existing out door unit of 17 TR AC unit (8.5 TR x 2 Nos) from its existing position after removing the electrical connections, Copper pipe connections etc. without any damages, conveying the same to ground level from Terrace floor using suitable tools and plant etc. as required at site.
OD345620/2024-2025:loading, transporting the dismantled Out door unit of 17TR AC unit (2 Nos 8.5 TR) to the nearest AC service center, complete overhauling, repairing/replacing the defective accessories, consumables etc. if required, leak/pressure testing, and transporting to the new location without any damage including un loading
OD355638/2024-2025:Installation testing and commissioning of out door unit of 17 TR AC unit in new location using necessary angle iron support/ direct on RC roof slab/ sun shade slab, connecting copper pipes, giving electrical inter connections from AHU etc complete required at site.
OD356239/2024-2025:Dismantling the existing outdoor and indoor units of 3 TR packaged AC unit from its existing position after removing the electrical connections, Copper pipe connections etc. without any damages, conveying the same to new location and installation testing and commissioning after attending minor repairs/replacement of spares , overhauling, gas filling cleaning etc as required
OD355788/2024-2025:Reconditioning/repairing the existing AHU indoor cabinet after removing the damaged portion, cutting and joining and painting including replacing the support etc. as required at site
OD344718/2024-2025:Supply fabrication and installation of 40 mm thick AHU out door cabinet for maintaining required temperature made with preprinted galvanized GI sheets of required thickness and density locking type construction film coated surface PUF insulated , supporting with powder coated GI angle and channels, off white color and suitable door opening for inspection and service etc as required at site
OD344717/2024-2025:Supply ,installation , balancing and commissioning of fabricated at site aluminum rectangular/round ducting complete with all fittings such as tees, bends, special shoots, inspection door, transformation pieces etc as per approved drawing and specification of 0.80mm sheet thickness complete as required
OD344725/2024-2025:Supply and providing following size hard/ soft drawn copper pipe for the extending the pipe between outdoor and indoor unit including providing rubberized form sleeve 10mm thick, brazing, leak testing etc. size 11/8 inch 22 gauge soft drawn copper pipe insulated using 10 mm thick rubber nitrite insulation
OD344723/2024-2025:Supply and providing following size hard/soft drawn copper pipe for the extending the pipe between outdoor and indoor unit including providing rubberized form sleeve 10mm thick, brazing, leak testing etc. size 5/8 inch 22 gauge soft drawn copper pipe insulated using 10 mm thick rubber nitrite insulation
OD344726/2024-2025:Supply and filling of R-410 gas
OD344724/2024-2025:Supply ,installation ,testing and commissioning of micro processor control panel for 8.5 / 11 / 17 TR AHU
OD344720/2024-2025:Supply and installation of class 'O' type nitrile rubber 10mm thick open cell elastomeric insulation for thermal insulation of duct make A flex/ K flex/ equivalent
OD344729/2024-2025:SITC of air supply diffusers of powder coated aluminum with alu. volume control dampers as per specification
OD344719/2024-2025:Supply an installation of Five micron filters for pre-filtration of air down to 5 micron at an efficiency of 98.5% suitable for AHU
OD344721/2024-2025:Supply and installation of 0.3 micron filters for pre filtration of air down to 0.5 micron at an efficiency of 99.7% suitable for AHU
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
90.6.4.52:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 2 Run
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD355965/2024-2025:Supply and providing suitable size canvas coupling for connecting the AHU unit with existing/ proposed Duct
OD542088/2024-2025:Dismantling the existing 33 TR room type Air Handling Unit of Air Conditioning units complete and clear out all materials from the site.
OD542101/2024-2025:Dismantling the existing 33 TR damage chiller unit Unit of Air Conditioning units complete and clear out all materials from the site.
OD542109/2024-2025:Dismantling the existing 11 TR condenser unit of Air Conditioning units complete and clear out all materials from the site
OD542144/2024-2025:Dismantling the existing damaged condenser unit and Air handling unit of Air Conditioning units complete and clear out all materials from the site
SHAJI P (BID ID -2197528)
Bidder Name
Bharath Aircon
SHAJI P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1211354.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .