Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹32.6 L+₹4.3 L (14.9%)Accepted-AOC | L2 | Accepted-AOC L1 | |
| 2 | L1₹28.5 LRejected-Finance CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Rejected-Finance INCORRECT DOCUMENTS |
Tender Value
₹36.5 L
EMD Value
₹50,000
Closing Date
10 Nov 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer North
Executive Engineer North Thiruvananthapuram Corporation 695033
Pro. No. 1319/24 Electrification of she Loadge (Nivasam) in Kazhakuttam Ward
2023_LSGD_615424_2
EE(N)/PLANFUND TENDER/2023-24(18)
Open Tender
Electrical Works
Item Rate
90 days
Kazhakuttam Ward
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Yes
₹50,000
Yes
6 Jan 2024
2 Nov 2023
13 Nov 2023
2 Nov 2023
10 Nov 2023
2 Nov 2023
Amount
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.55.1Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).
1.32Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 ampsmodular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD425783/2022-2023Supply and providing the following types and power rated lamps in the existing fittings as required B22 LED bulb 10 W
OD425872/2022-2023 Supply of Wall Lamp suitable for B22 lamp
90.3.14Conveyance, installation, testing and commissioning of foot light fittings / skirt lightof all types directly on wall including cutting necessary holes, giving connectionswith the extended orginal wiring, making good the damgaes, colour washing etc asrequired.
OD425873/2022-2023 Supply and fixing following Modular Switch / Socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required RJ 45 Socket Outlet
1.23.6Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.Telephone socket outlet
1.23.7 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.TV antenna socket outlet
1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm).
90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A pin Shuttered socket
90.10.3.32 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply
90.4.6Conveyance, installation, testing and commissioning of wall mounting fans of alltypes using mounting brackets supplied along with the fan.
90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required.
90.4.10Conveyance, installation , testing and commissioning of exhaust fans of size up to450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., asrequired including giving connections with the supplied wire along with the exhaustfan.
OD425785/2022-2023Supply of 250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C including all accessories as required(PWD approved make)
OD425786/2022-2023Supply of 300/305mm sweep 1400 RPM heavy duty exhaust fan working on 230 V A/C in metal frameincluding all accessories as required (PWD approved make)
90.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell onexisting M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wireconforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
90.3.12Conveyance and fixing charges of recess mounting down light fittings of all typescomplete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
90.3.13Conveyance, installation, testing and commissioning of ornamental wall light fittings of all types directly on wall including giving connections with required length of16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc asrequired.
90.3.15Conveyance, installation, testing and commissioning of post-top lantern/ outdoor type FTL/ CFL fittings of all types directly on the existing pipe/ pole and givingconnections with the existing wiring etc as required
90.3.18.2Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clampsas noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc asrequired.32 mm dia with HG company fabricated clamps
90.3.20.3Supply & installation of light fittings on TW round block<br>Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD425807/2022- 2023 Supply and fixing of Sintex make junction box of size 140mmx140mmx95mm with connector suitable for terminating pole lighting.
OD425997/2022-2023 Supply of 6W mirror lamp including necessary accessories
OD425808/2022-2023 Supplyof 3W round LED surface mounted light fitting including all accessories.
OD425809/2022-2023 Supply of 12WLED Ornamental type double side up & down Lamp suitable for 230 V AC. (PWD approved make with ISI)
OD425810/2022-2023 Supply of 450mm sweep wall mounting metal type fan with minimum noise (PWD approved make)
OD425811/2022-2023 Supply of 30 watts 600x600 mm Square recessed type LED light 100 lumen/watt including all accessories as required.(Philips/Havells/ PWD approved make with ISI)
90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED streetlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/ Lumilled/ Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79& 80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.5Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should beseperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer)
OD202993/2023-2024 SITC of 1 metre height 8/10 watts Landscape/Bollard light with uniformly lit diffuser at the upper portion and making necessary connection as required.
2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/ Isolator16 way, Double door
90.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP42/43)
90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP42/43)
90.11.1.15Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN verticalDB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.19Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.20Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43)
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.40 amps
2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. asrequired.63 amps
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.17Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts "C" curve TP MCB complete with connections,testing and commissioning etc. as required.
1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
90.9.1.1Supply and fixing 50 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678on surface / recess including cutting the wall and making good the damages in caseof recessed installation as required.50x50mm Cable Management System with baseand lid
90.9.1.7Supply and fixing 50 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.1.9Supply and fixing 50 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678on surface / recess including cutting the wall and making good the damages in caseof recessed installation as required.Joint cover
1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable
1.53.2 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required2 run of Cable
1.53.3 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required3 run of Cable
1.18.2Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealedcopper conductor,unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required.2 Pair
1.19Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copperconductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
90.6.4.3Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single corecopper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the followingsizes.1.00 sq.mm 3 Run
90.12.5.12Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm
90.12.5.38Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm
90.12.7.12Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3 core 4 sq mm with factory made clamp
90.12.7.38Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
90.12.7.14Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
90.12.7.28Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory madeclamp
90.12.7.29Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory madeclamp
90.12.7.30Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.31Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
90.12.7.32Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 120 sq mm
90.12.7.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 185 sq mm
90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.42Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.5.34Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm
90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in theexisting trench 50/38 mm or nearest size
9.1.7Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 X 10 sq. mm (22mm)
9.1.21Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.22Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 50 sq. mm (35mm)
9.1.25 Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.23Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 70 sq. mm (38mm)
9.1.24Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 95 sq. mm (45mm)
9.1.27Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 1/2X 185 sq. mm (57mm)
9.2.24Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185sq. mm
9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm)
9.1.34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 25 sq. mm (28mm)
2.1.2Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.63 Amp TP & N
2.1.4Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.125 Amp TP & N
2.1.5Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.160 Amp TP&N
2.1.6Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.200 Amp TP&N
2.1.7Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.320 Amp TP&N
90.14.10.10Supply, conveyance and fixing the following types & current rated control gears& switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply inthe existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload settingof 50 - 100% having adjustable OL & SC
90.14.10.11Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply inthe existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload settingof 50 - 100% having adjustable OL & SC
90.14.10.12Supply, conveyance and fixing the following types & current rated control gears& switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply inthe existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload settingof 50 - 100% having adjustable OL & SC
90.14.10.13Supply, conveyance and fixing the following types & current rated control gears& switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply inthe existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload settingof 50 - 100% having adjustable OL & SC
90.14.10.14Supply, conveyance and fixing the following types & current rated control gears& switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply inthe existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload settingof 50 - 100% having adjustable OL & SC
OD202995/2023-2024 Supply and fixing AuXC - 2000 Controller with wire harness & Illuminated Push button assembly with wire harness
OD202871/2023-2024 Supply and fixing 160 A 4 pole ATS on existing panel board, connections etc.
OD425875/2022-2023 Supply, installation,testing and commissioning of 16 port unmanaged Network Switch 10/100/1000Mbps ,complete as required.
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.
5.10Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refillingetc. as required.
90.16.1.2Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.1.6Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)
90.16.2.3Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench ofsuitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
90.16.5.2Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.6Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.6. mm ( 4 SWG)
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyas per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1 Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc..
90.14.3.1Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.4 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD202873/2023-2024 Design, supply and fixing Aluminium Bus Bar with appropriate accessories conforming IS guidelines.
90.14.11.1 MCCB AccessoriesSupply and fixing one number earth fault Relay up to 100A with CBCT.
90.14.11.2 MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to 200A with CBCT.
90.14.11.13 MCCB AccessoriesSupply and fixing rotary handle,External type (including BUChandle with door interlock ) in the existing MCCB of rating up to 250 A
OD202853/2023-2024 Supply and providing Red/Green/Yellow colours LED indicator
OD202854/2023-2024 Supply and providing Multifunction meter to read: V, A, F, 3 phase accuracy class 1
OD425825/2022-2023 Supply & fixing of 250, HRC Fuse Base with HRC Fuse link
OD425826/2022-2023 Supply and fixing 100A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.
OD202845/2023-2024 Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.
OD202846/2023-2024 Supply and fixing 100A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
OD202847/2023-2024Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
OD202851/2023-2024Supply and providing 100/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT including giving necessary connections as required
OD202866/2023-2024 Supply of Fire Extinguisher-ABC 5 Kg Type
OD202867/2023-2024 Supply and laying 3.00 mm thick, 33 kV, Synthetic elastromeric fire retardantinsulating mat
OD425996/2022-2023Supply, conveyance, installation, testing and commissioning of LED Board with1.5W,12V, LED Lamp for Background Lighting with adequate AC to DC Converterand Acrylic sheet with Printed Image for Display (Dimensions, image/ Letters size& design, place of fixing etc. will be as per the directions of the concerned CivilEngineer/ Officials) with 3 years warranty
14.1Excavation for foundation in soft soil including dressing of sides and ramming ofbottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
SYNERGY POWER TECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_928337.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .