| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.0 LAccepted-AOC | 1 | Accepted-AOC accepted by competent authority | |
| 2 | 2₹6.0 L+₹1,875 (0.31%)Rejected-AOC | 2 | Rejected-AOC Only L1 is acceptable |
Tender Value
₹5.8 L
EMD Value
₹11,611
Closing Date
14 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E), BSNL, ED Kota
E-10B Exchange campus, Road no-2, IPIA, Kota
Rate contract for call basis repairing of EI and Fans, shifting, ITC of AC and miscellaneous work in SSA Kota .
2020_BSNL_63375_1
20/20-21/BSNL/ED /KOTA
Open Tender
Miscellaneous Works
Item Rate
180 days
kota
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash), O/o GMTD BSNL, KOTA
₹11,611
23 Dec 2020
1 Dec 2020
16 Dec 2020
1 Dec 2020
14 Dec 2020
2 Dec 2020
90 days
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
3 x 1.5 sq. mm
4 x 1.5 sq. mm
5 x 1.5 sq. mm
2x2.5 Sq.mm.
4x2.5 Sq.mm.
2x4 Sq.mm.
4x4 Sq.mm.
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required.
S/F of 4 module polycarbonate modular surface boxes with suitable size phenolic laminated sheet cover in front i/c one no 6A Celiling rose i/c fixing the same on wall /ceiling etc as reqd.
S/F of following size Ceiling fan suitable for operation on 230 Volts ,single phase 50 Hz AC supply complete etc as reqd (without regulator)Make -( Bajaj/Polar /USHA /crompton /havells /orient )
S/F of D type fan hook made of 08 mm (NS)dia MS rod i/c fixing the same on ceiling with 2 pcs.of heavy duty Fasteners (M10x75mm) etc as required.
Supplying and fixing extra down rod of 20 cm length G.I. pipe,15mm dia, heavy gauge including painting etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
S/F of two module Stepped type electronic fan regulator in existing board I/c dismantling of existing faulty regular (if required ) and connection, testing etc. as reqd ( Make -Anchor /havells )
Making square opening in brick/stone wall for exhaust fan up to 450mm sweep i/c cutting of wall for making suitable size hole ,packing the extra space ,plaster finishing i/c cleaning the space after execution of Work etc as reqd
SITC of 450mm sweep heavy duty exhaust fan with metallic louvers shutter 1400 RPM suitable for work on 230 V Single phase AC Supply ,i/c fixing the same wall surface /grill with suitable clamp i/c connection etc as reqd (Make -Almonard/crompton/Bajaj/USHA).
S/F of 450 mm sweep heavy duty mark II oscillating type Padestal fan with 3 speed control regulator having powder coated guard and aluminium die cast blade ,1440 RPM speed suitable for working on 230 V 50 Hz single phase AC supply & i/c connection etc. complete as required (Almonard /Crompton/Bajaja or SS )
SITC of 1x18/20 Watt LED Box type luminare with CRCA Housing having efficency 100 lumes /watt complete with T-8 LED tube rod in polycarbonate housing , suitable for work on 230 volt 50Hz AC supply i/c connection testing etc complete as required.(Make -Philips /crompton/Havells /Bajaj/Wipro/Surya ).
S/F of 6 W Surface mounting LED panel square flush model suitable for work on 230 V etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ).
S/F of 12 W Surface mounting LED panel square flush model suitable for work on 230 V etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ).
SITC of 45 Watt Energy Efficient LED type Road Light luminare with pressure die cast aluminum with mid power LED's as light sources & Heat Resistant toughended glass with frame cover and integral electronic driver complete with IP 66 protection ,min.system efficacy 100 lm/Watt., THD<10%, PF>0.95 suitable for work on 140-270 V AC Supply i/c ixing on existing GI bracket / Pole with suitable modificaion of braket (if reqd) and connection with 3 Core 1.5 sqmm PVC insulated PVC Sheathed copper conductor cable from fitting to MCB in MS box through GI Bracket / Pole etc. as reqd. The fixture shall have a corelated color temperature of at least 5000K and a CRI of > 70. The Light system shall be designed for system life 50000 hour i/c removing of existing faulty light etc as reqd . (Make -Philips /crompton/Havells /Bajaj/Wipro )
SITC of 25 Watt Energy Efficient LED type Road Light luminare with pressure die cast aluminum with mid power LED's as light sources & Heat Resistant toughended glass with frame cover and integral electronic driver complete with IP 65 protection ,min.system efficacy 100 lm/Watt., THD<10%, PF>0.95 suitable for work on 140-270 V AC Supply i/c ixing on existing GI bracket / Pole suitable modificaion of braket (if required) and connection with 3 Core 1.5 sqmm PVC insulated PVC Sheathed copper conductor cable from fitting to MCB in MS box through GI Bracket / Pole etc. as reqd. The fixture shall have a corelated color temperature of at least 5000K and a CRI of > 70. The Light system shall be designed for system life 50000 hour i/c removing of existing faulty light etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ).
SITC of 60 Watt Energy Efficient LED type flood Light luminare with pressure die cast aluminum with mid power LED's as light sources & Heat Resistant toughended glass with frame cover and integral electronic driver complete with IP 66 protection ,min.system efficacy 100 lm/Watt., THD<10%, PF>0.95 suitable for work on 140-270 V AC Supply i/c fixing on existing MS /GI bracket / Pole with suitable modificaion of braket (if reqd) and connection with 3 Core 1.5 sqmm PVC insulated PVC Sheathed copper conductor cable from fitting to MCB in MS box on existing GI Bracket / Pole etc. as reqd. The fixture shall have a corelated color temperature of at least 5000K and a CRI of > 70. The Light system shall be designed for system life 50000 hour i/c removing of existing faulty MH flood light fixture etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro ). .
S/F of ABS make moulded weather proof ,shocked proof ,fire retartand ,Compound light control gear box of size 200mmx150mm x100mm suitable for pole mountung and cable entry from bottom side with side hinges door i/c S/F of 6 Amp "C " Curve SP MCB on Din channel and two no 16A neutral Link i/c dismantling of existing faulty/unserviceable M S Box I/c connection testing etc as reqd (Make SINTEX or SS )
Supplying of following size of pvc insulated pvc sheathed 1.1 kv grade Aluminium conductor armoured cable confirming to relevant IS-Specification etc complete as reqd. (Make -Polycab/havells/finolex)-
2 x 6 Sqmm.
2 x 16 Sqmm.
4 x 16 Sqmm.
3-1/2 x 50 Sqmm.
3-1/2 x 95 Sqmm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering
Up to 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade of following size on surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland & aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as reqd.
2 X 6 sq. mm (19mm)
2 X 16 sq. mm (22mm)
4 X 16 sq. mm (28mm)
3½ X 50 sq. mm (35mm)
3 1/2 x 120 Sq.mm.(45mm)
3 1/2 x185 Sq.mm.(57mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required
S/F of 20 mm wide PVC cassing capping on wall /roof wit suitalbe screw etc as reqd.
Refilling of exisitng CO2 type 4.5 Kg Capacity Fire Extinguishers of following capacity with CO2 up to desired specified pressure i/c transportation of empty the cylinder to & fro , cleaning, refilling the gas and testing etc. complete as reqd. ( Note - Work shall be carried out only by specialized agency and necessary test certificate for each refilled cylinder is to be submitted).
Refilling of exisitng Dry Chemical Powder type up to 10 Kg Capacity Fire Extinguishers with help of Chemical Powder and refilling of Cartridge i/c transportation, empty the cylinder, cleaning, refilling the cartridge and testing etc. complete as reqd. ( Note - Work shall be carried out only by specialized agency and necessary test certificate for each refilled cylinder is to be submitted )
S/F of One meter hose pipe with horm for 4.5 kg Co2 type fire extingusher i/c fixing and testing etc as reqd.
Replacement & Fixing of 12 Volt and following Ah Sealed maintenance free battery duly charged i/c removing the existing battery, connect the terminal with new one I/c testing etc. sa complete as reqd.
S/F of single phase SMC plastic moulded weather proof ,shocked proof ,maitenance free fire retardant meter box of size 250mmx200mm x100mm with viewing window suitable for wall mountung and cable entry from bottom side with side hinges door I/c fixing on wall with suitable fastner i/c connection testing etc as reqd (Make SINTEX or SS).
Supplying and fixing of following size of flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd
3x2.5 sq mm
3x1.5 sq mm
S/F of 63 amps four pole OFF load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c fixing the same on wall /pole with suitable clamp/fastner i/c drilling hole , making connection, earthing the body etc. i/c dismenting of existing faulty unit (if requiredat site)as reqd.
S/F 63 Amps TPN Switch fuse unit with HRC fuses in steel enclosure with side handle operation capable of working 415/500 V i/c i/c fixing the same on wall /pole with suitable clamp/fastner i/c drilling hole , making connection, earthing the body etc. i/c dismenting of existing faulty unit (if requiredat site)as reqd.
S/F of 100 amps four pole on load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
S/F 100 Amps Heavy duty double break TPN Switch fuse unit with HRC fuses in steel enclosure with side handle operation capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.
S/F of 200 amps four pole off load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c fixing the same on wall /pole with suitable clamp/fastner i/c drilling hole , making connection, earthing the body etc. i/c fixing of two no loose wire box made out of 16 SGW MS sheet (one at TOP and one at Bottom side) of suitable size match the size of change over switch (hight apppox 300mm ) i/c painting etc as reqd.
S/F 200 Amps TPN Switch fuse unit with HRC fuses in steel enclosure with side handle operation capable of working 415/500 V i/c i/c fixing the same on wall /pole with suitable clamp/fastner i/c drilling hole , making connection, earthing the body etc. i/c i/c fixing of two no loose wire box made out of 16 SGW MS sheet (one at TOP and one at Bottom side) of suitable size match the size of change over switch (hight apppox 300mm ) i/c painting etc as reqd.
S/F 250 A Rating 4 Pole MCCB with thermal magnetic release having breaking capacity 50 KA , Ics=75% of Icu having adjustable thernal over load (.08 to 1x I n) and adjustable short circuit 5-10 In with UVR ,auxillary contact i/c fixing the same in existing panel i/c removing of faulty MCCB i/c modification in existing bubar system (if required) and wiring for phase indication complete as reqd.
S/F of following electrical items in existing Electrical Installation I/c dismantling of existing faulty items (if required ) and connection, testing etc. as reqd.( Note- All spare of lighting systen should be of Make -Bajaj/crompton/philips /havells )
LED Type Indication lamp(R,Y,B)
Ceiling rose
Bakalite Holder
4'- 36 / 40 Watt Fluoresent Tube Rod
Electronic choke suitable 36 / 40 Watt tube fitting
Starter for fluorsent Tube Light
Side Holder for all type Tube Light fitting
2.5 to 4 MFD MPP capacitor for fan
5 Amp. Piano Type switch.
3 Pin ,5 Amp. Socket outlet.
15/16 Amp. Switch.
15/16 Amp , 3/6 pin Socket outlet.
S/F of Analog dial type 3 module time switch suitale for work on 230V Single phase AC Supply with 16 A Capacity and with one change over facility with base /din mounted facility i/c connection etc as required (M/S L&T or SS)
Rewinding of following fan motor with suitable gauge copper winding wire I/c dismantling, servicing, replacement of bearing/bush and reinstallation, testing etc. as reqd.
Ceiling fan up to 1400 mm size
Exhaust fan / Wall mounting fan up to 450 mm size
Air circulator/ pedestal Fan Up to 450 mm size
Servicing of ceiling fan of up to 1400 mm. sweep with greasing ,oiling including replacement of defective ball bearing I/c dismantling & re-installation etc. comp. as reqd.
Servicing ,Oiling & Greasing of Heavy duty air circulating/ wall mounting fan including replacement of defective ball bearing i/c dismantling and re-installation etc. comp. as reqd.
Dismentling of existng all type eiling fan/ Wall Fan/Exhaust fan from true ceiling / Wall i/c disconnection of wire andshifting the same up to store as per direction of -In-charge etc as reqd.
Dismantling of the existing split /window type AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd (Note- Existing refrigerent from working Split AC to be stored in compressor before dismentling for further use at new location).
Transportation of Split /Window AC units with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board as dismentalled from TE Jhalawar to various TE /BTS sites in SSA up to 50 KM i/c. loading,unloading etc. as reqd.
Installation, Testing & Commissioning of the 1.5 TR inverter type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall, laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 5 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.
Pdg and Fixing additional 1/4"&5/8" size or size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured )
Provision of Top up of R-22/R-32 /410 gas in existing Window A.C /Split A.C units, i/c flushing, testing etc. as required.
S/F of 50 mm dia 2 mm thick PVC pipe on wall / surface for protection of refrigerant pipe of split AC units etc.i/c elbo /bend /socket etc as complete as reqd.
Closing of existing window in AC plant room to prevent AC leakage by brick masnoary i/c plastering , finishing etc complete as reqd as reqd.
General Servicing of 1.5 /2.0 TR WAC/SAC units at site of different make I/c removing from existing position if reqd., dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of caustic soda soap solution, lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to TDR to AC unit etc as reqd.
Charging of Refrigerant gas R-22 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e.. One complete air conditioning circuit only.
1.5 TR WAC/ Split AC
S/F of 75 mm dia PVC green suction pipe with PVC sprial ribbed on wall / surface for protection of refrigerant pipe of split AC units i/c fixing with suitable MS shaddle etc.as te reqd.
Shifting of Existing all type light fitting /Fire detector from wall /ceiling /false ceiling / AC duct Boxing dismentling from one location with all acesssories i/c ITC on ceiling/wall/flase ceiling i/c connection i/c cleaning of the light fitting as per direction of Engineering -In-charge etc as reqd.
Dismantling the existing MDF partical board return air Boxing of all size & shape from AC plant to corridor -BB room -Transmission room complete by unscrewing , opening the MDF partical board , angle iron supports, then lowering down the same from first floor to ground floor i/c shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.etc as reqd.
Dismantling the existing old GI ducts /plenum of all size & shape of from package plant to all rooms along with damper ,S/A , R/A Grill complete by unscrewing, opening the flanges, supports,hangers, lowering down the same from first floor to ground floor i/c shifting the same to the place inside the exchange premises as directed by Eng.-in-charge.
Pdg. Making opening in stone /brick wall for fresh air i/c cutting of wall for making suitable size opening, packing the extra space ,plaster finishing i/c cleaning the space after execution of Work etc as reqd.
Fixing of existing spare MDF partical board for closeing of existing opening in false ceiling /WAC opening /other opening i/c cutting and fixing with suitable screw as per site requirement etc as reqd.
Dismentling of existing aluminum partation ,doors, fixed glass panes i/c remoing of vertical members fixed in floor with rawal plug and shifting and stacking of sericable material in the same building same floor within 50 meter lead as directed by Engineering-in-charge.
S/F of following MS items to be used for for frame work /Exhaust fan grill I/c Cutting , welding painting etc. as required.
35mm X 35mm X 5mm Angle iron
25mm X 25mm X 3mm Angle iron
1"x1" square MS wire mesh of 18 SWG wire
20 SWG MS Sheet
20x3 mm MS flat
super engineering service
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .